Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Open accessAbstract
A retinal prosthesis was permanently implanted in the eye of a completely blind test subject. This report details the results from the first 10 weeks of testing with the implant subject. The implanted device included an extraocular case to hold electronics, an intraocular electrode array (platinum disks, 4 x 4 arrangement) designed to interface with the retina, and a cable to connect the electronics case to the electrode array. The subject was able to see perceptions of light (spots) on all 16 electrodes of the array. In addition, the subject was able to use a camera to detect the presence or absence of ambient light, to detect motion, and to recognize simple shapes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Due to axonal activation, phosphenes often appear with an elongated shape distorting the image perceived by the patient [46].”
From Advances in visual prostheses: engineering and biological challenges (2022) · cites this paper as [46]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prevalence of age-related maculopathy
Klein, R., Klein, B. E. K., & Linton, K. L. P. (1992) · Ophthalmology · doi:10.1016/s0161-6420(92)31871-8 · Cited by 1,845
The Five-year Incidence and Progression of Age-related Maculopathy
Klein, R., Klein, R., Jensen, S. C., & Meuer, S. M. (1997) · Ophthalmology · doi:10.1016/s0161-6420(97)30368-6 · Cited by 1,154
Will Retinal Implants Restore Vision?
Zrenner, E. (2002) · Science · doi:10.1126/science.1067996 · Cited by 736
Preservation of the Inner Retina in Retinitis Pigmentosa
Santos, A. (1997) · Archives of Ophthalmology · doi:10.1001/archopht.1997.01100150513011 · Cited by 651
Visual Perception Elicited by Electrical Stimulation of Retina in Blind Humans
Humayun, M. S. (1996) · Archives of Ophthalmology · doi:10.1001/archopht.1996.01100130038006 · Cited by 602
Self-citationPattern electrical stimulation of the human retina
Humayun, M. S., de Juan, E., Weiland, J. D., Dagnelie, G., Katona, S., Greenberg, R. J., & Suzuki, S. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00052-8 · Cited by 598
Self-citationMorphometric analysis of the extramacular retina from postmortem eyes with retinitis pigmentosa.
Humayun, M. S., Prince, M. R., de Juan, E., Barrón, Y., Moskowitz, M., Klock, I. B., & Milam, A. H. (1999) · PubMed · Cited by 366
Self-citationNeural prostheses : fundamental studies
Agnew, W. F., & McCreery, D. B. (1990) · Medical Entomology and Zoology · Cited by 316
Learning Retina Implants with Epiretinal Contacts
Eckmiller, R. (2009) · Ophthalmic Research · doi:10.1159/000268026 · Cited by 257
Subretinal electrical stimulation of the rabbit retina
Chow, A. Y., & Chow, V. Y. (1997) · Neuroscience Letters · doi:10.1016/s0304-3940(97)00185-7 · Cited by 242
Cited by
Sorted by citations
Items 501–600 of 855
Mokwa, W. (2008) · Elsevier eBooks · doi:10.1016/b978-044452190-3.00027-6 · Cited by 8
Psychophysics of Prosthetic Vision: II. Stochastic Sampling, the Phosphene Image, and Noise
Hallum, L. E., Chen, S. C., Cloherty, S. L., & Lovell, N. H. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.259957 · Cited by 8
The Future of Implantable Neuroprosthetic Devices: Ethical Considerations
Chhatbar, P. Y. (2009) · Journal of Long-Term Effects of Medical Implants · doi:10.1615/jlongtermeffmedimplants.v19.i2.40 · Cited by 8
Mapping Retinal Degeneration and Loss-of-Function in Rd-FTL Mice
Greferath, U., Goh, H. C., Chua, P. Y., Ästrand, E., O'Brien, E. E., Fletcher, E. L., & Murphy, M. (2009) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.09-3916 · Cited by 8
Complications of Ocular Surgery
CHANDLER, P. A., Fry, W. E., Sj, M., SACHS, B., & Thorpe, H. E. (2010) · Elsevier eBooks · doi:10.1016/b978-0-7020-3320-9.50021-0 · Cited by 8
Advances in Electrode Design and Physiological Considerations for Retinal Implants
Gong, C. A. (2025) · Micromachines · doi:10.3390/mi16050598 · Cited by 9
Negative differential conductance materials for flexible electronics
Nogaret, A. (2013) · Journal of Applied Polymer Science · doi:10.1002/app.40169 · Cited by 7
An ultra low power digital receiver architecture for biomedical applications
Goodarzy, F., Koushaeian, L., Ghafari, B., & Skafidas, E. S. (2011) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2011.6107755 · Cited by 7
Visual Prostheses: Neuroengineering Handbook
Guo, T., Shivdasani, M. N., Tsai, D., Ayton, L. N., Rathbun, D. L., & Lovell, N. H. (2021) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_31-2 · Cited by 7
Flexible Circuit Technologies for Biomedical Applications
Damien, C., Li, W., James, D., MARK, S. D., & Tai, Y. (2013) · InTech eBooks · doi:10.5772/55308 · Cited by 7
A Novel In Vitro Sensing Configuration for Retinal Physiology Analysis of a Sub-Retinal Prosthesis
Koo, K.-I., Lee, S., Yee, J. H., Ryu, S. B., Kim, K. H., Goo, Y. S., & Cho, D. (2012) · Sensors · doi:10.3390/s120303131 · Cited by 7
Liang, T., Zhao, L., Sui, X., Zhou, C., Ren, Q., & Qi, Y. (2010) · Ophthalmic Research · doi:10.1159/000317034 · Cited by 7
What limits spatial perception with retinal implants?
Hamish Meffin, A. (2013) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2013.6738318 · Cited by 7
Sui, X., Huang, Y., Feng, F., Huang, C., Chan, L. L. H., & Wang, G. (2015) · The International Journal of Artificial Organs · doi:10.5301/ijao.5000412 · Cited by 7
Optimization of a Dual-Band Wireless Power and Data Telemetry System Using Genetic Algorithm
Wang, G., Li, X., Wang, M., Yuan, H., & Xu, W. D. (2016) · IEEE Design and Test · doi:10.1109/mdat.2016.2582828 · Cited by 7
Introduction to Visual Prostheses
Fernández, E., & Normann, R. A. (2016) · Europe PMC (PubMed Central) · Cited by 7
Development of an image biosensor based on an optogenetically engineered cell for visual prostheses
Li, G., Wang, F., Yang, W., Yang, J. R., Wang, Y., Wang, W., & Liu, L. (2019) · Nanoscale · doi:10.1039/c9nr01688k · Cited by 7
A preparation for studying electrical stimulation of the retinain vivoin rat
Baig-Silva, M. S., Hathcock, C. D., & Hetling, J. R. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/005 · Cited by 7
Live-Cell-Driven Insertion of a Nanoneedle
Hoshino, T., Konno, T., Ishihara, K., & Morishima, K. (2009) · Japanese Journal of Applied Physics · doi:10.1143/jjap.48.107002 · Cited by 7
Delbeke, J., & Veraart, C. (2006) · Wiley eBooks · doi:10.1002/0471732877.emd325 · Cited by 7
Çelik, M. E., & Karagoz, I. (2015) · Acta Physica Polonica A · doi:10.12693/aphyspola.128.b-297 · Cited by 6
Kominami, T., Ueno, S., Ota, J., Inooka, T., Masahiro, O., Mori, K., & Nishiguchi, K. M. (2025) · Japanese Journal of Ophthalmology · doi:10.1007/s10384-025-01163-w · Cited by 6
Kiral-Kornek, F. I., O’Sullivan-Greene, E., Savage, C. O., McCarthy, C. D., Grayden, D. B., & Burkitt, A. N. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/6/066002 · Cited by 6
A low noise cascaded amplifier for the ultra-wide band receiver in the biosensor
Daoud, M., Ghorbel, M., & Mnif, H. (2021) · Scientific Reports · doi:10.1038/s41598-021-02122-4 · Cited by 6
Roh, H., Otgondemberel, Y., Eom, J., Kim, D. J., & Im, M. (2023) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2023.1115703 · Cited by 6
Repairing lesions via kernel adaptive inverse control in a biomimetic model of sensorimotor cortex
Li, K., Durá-Bernal, S., Francis, J. T., Lytton, W. W., & Príncipe, J. C. (2015) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2015.7146663 · Cited by 6
Kanda, H., Mihashi, T., Miyoshi, T., Hirohara, Y., Morimoto, T., Terasawa, Y., & Fujikado, T. (2014) · Japanese Journal of Ophthalmology · doi:10.1007/s10384-014-0319-3 · Cited by 6
The Bionic Eye: Retinal Prostheses
Park, R. I. (2004) · International Ophthalmology Clinics · doi:10.1097/00004397-200404440-00011 · Cited by 6
Decoding of retinal ganglion cell spike trains evoked by temporally patterned electrical stimulation
Ryu, S. B., Ye, J. H., Goo, Y. S., Kim, C. H., & Kim, K. H. (2010) · Brain Research · doi:10.1016/j.brainres.2010.06.044 · Cited by 6
Progress towards a high-resolution retinal prosthesis
Butterwick, A., Vankov, A., Huie, P., Vijayraghavan, K., Loudin, J., & Palanker, D. (2007) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.701787 · Cited by 6
Anatomically based Bayesian decoding of the cortical response to intracortical microstimulation
Millard, D. C., & Stanley, G. B. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6696219 · Cited by 6
Menzel-Severing, J., Sellhaus, B., Laube, T., Brockmann, C., Bornfeld, N., Walter, P., & Roessler, G. F. (2011) · Ophthalmic Research · doi:10.1159/000324650 · Cited by 6
The Perceptual Effects of Chronic Retinal Stimulation
Horsager, A., & Fine, I. (2011) · Springer eBooks · doi:10.1007/978-1-4419-0754-7_14 · Cited by 8
Psychophysics of Prosthetic Vision: III. Stochastic Rendering, the Phosphene Image, and Perception
Hallum, L. E., Cloherty, S. L., Taubman, D., Suaning, G. J., & Lovell, N. H. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.259956 · Cited by 6
Object recognition based on a foreground extraction method under simulated prosthetic vision
Han, T., Li, H., Lyu, Q., Zeng, Y., & Chai, X. (2015) · International Symposium on Bioelectronics and Bioinformatics (ISBB) · doi:10.1109/isbb.2015.7344951 · Cited by 6
Semantic labelling to aid navigation in prosthetic vision
Horne, L., Álvarez, J. M., McCarthy, C. D., & Barnes, N. M. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319117 · Cited by 7
Argus® II Retinal Prosthesis System
Falabella, P., Nazari, H. K., Schor, P., Weiland, J. D., & Humayun, M. S. (2016) · Springer eBooks · doi:10.1007/978-3-319-41876-6_5 · Cited by 6
Self-citationBiocompatible Organic/Inorganic Composite Film Packaging for Implantable Retinal Prosthesis
Zhao, S., Feng, Y., Xiong, S., Peng, B., Sun, B., Wu, T., & Yang, C. (2018) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems.2018.8556901 · Cited by 6
Kominami, T., Ueno, S., Nishida, K., Inooka, D., Kominami, A., Kondo, M., & Terasaki, H. (2019) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.19-26972 · Cited by 6
Wireless Powering and Propagation of Radio Frequencies through Tissue
Chow, E. Y., Yang, C., & Irazoqui, P. P. (2022) · River Publishers eBooks · doi:10.1201/9781003340065-9 · Cited by 6
A hierarchical image processing strategy for artificial retinal prostheses
Jiang, H., Li, H., Liang, J., & Chai, X. (2020) · International Conference on Artificial Intelligence and Computer Engineering (ICAICE) · doi:10.1109/icaice51518.2020.00075 · Cited by 6
ERG and Behavioral CFF in Light-Damaged Albino Rats
Rubin, G. R., Wen, Y., Loop, M. S., & Kraft, T. W. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23084127 · Cited by 6
Flexible Electrode for Implantable Neural Devices
Tsang, W. M., & Je, M. (2014) · Springer eBooks · doi:10.1007/978-1-4614-8151-5_6 · Cited by 6
The influence of visual field position induced by a retinal prosthesis simulator on mobility
Endo, T., Hozumi, K., Hirota, M., Kanda, H., Morimoto, T., Nishida, K., & Fujikado, T. (2019) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-019-04375-2 · Cited by 6
Neural Information Processing Efforts to Restore Vision in the Blind
Eckmiller, R., Baruth, O., & Neumann, D. (2004) · Lecture notes in computer science · doi:10.1007/978-3-540-30499-9_2 · Cited by 6
Dispersion and Accuracy of Simulated Phosphene Positioning Using Tactile Board
Zhang, L., Chai, X., Ling, S., Fan, J., Yang, K., & Ren, Q. (2009) · Artificial Organs · doi:10.1111/j.1525-1594.2009.00826.x · Cited by 6
Information transmission from a retina implant to the cat visual cortex
Eckhorn, R., Eger, M., Wilms, M., & Schanze, T. (2005) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.2004.1379871 · Cited by 6
Soussou, W., Gholmieh, G. I., Han, M., Ahuja, A., Song, D. B., Hsiao, M.-C., Wang, Z., Tanguay, A. R., & Berger, T. W. (2006) · Springer eBooks · doi:10.1007/0-387-25858-2_6 · Cited by 6
Design of the optoelectronic high-resolution retinal prosthesis
Palanker, D., Vankov, A., Huie, P., & Blumenkranz, M. S. (2005) · Ophthalmic Technologies · doi:10.1117/12.590964 · Cited by 6
Metabolic Prosthesis for Oxygenation of Ischemic Tissue
Greenbaum, E., Humayun, M. S., Sanders, C. A., Close, D., O’Neill, H., & Evans, B. R. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2003263 · Cited by 6
Self-citationEntwicklung eines minimal-invasiven Retinaimplantats
Gerding, H. (2008) · Der Ophthalmologe · doi:10.1007/s00347-007-1631-9 · Cited by 6
High-Resolution Opto-Electronic Retinal Prosthesis: Physical Limitations and Design
Palanker, D., Vankov, A., Huie, P., Butterwick, A., Chan, I., Marmor, M. F., & Blumenkranz, M. S. (2007) · Springer eBooks · doi:10.1007/978-0-387-49331-2_14 · Cited by 5
Operational challenges of retinal prostheses
Schmid, E. W., Fink, W., & Wilke, R. G. H. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.09.004 · Cited by 5
Woo, S. J., Kim, S. J., Zhou, J. A., Kim, E., Seo, J.-M., Park, J., Kim, Y. K., Lee, J. S., Kim, S. J., & Chung, H. (2012) · Biomedical Engineering Letters · doi:10.1007/s13534-012-0060-0 · Cited by 5
Operational Design Considerations for Retinal Prostheses
Schmid, E. W., & Fink, W. (2016) · IEEE Circuits and Systems Magazine · doi:10.1109/mcas.2016.2583678 · Cited by 5
Graphene coated dielectric resonator antenna for modeling the photoreceptors at visible spectrum
NoroozOliaei, M., Esfahani, H. R., & Abrishamian, M. S. (2022) · Heliyon · doi:10.1016/j.heliyon.2022.e09611 · Cited by 5
Design and Simulation of a Ring Transducer Array for Ultrasound Retinal Stimulation
Xu, C., Lu, G., Kang, H., Humayun, M. S., & Zhou, Q. (2022) · Micromachines · doi:10.3390/mi13091536 · Cited by 5
Self-citationBenefits of thermal and distance-filtered imaging for wayfinding with prosthetic vision
Sadeghi, R., Kartha, A., Barry, M. P., Gibson, P., Caspi, A., Roy, A., Geruschat, D. R., & Dagnelie, G. (2024) · Scientific Reports · doi:10.1038/s41598-024-51798-x · Cited by 5
Self-citationLoudin, J., Butterwick, A. F., Huie, P., & Palanker, D. (2011) · Springer eBooks · doi:10.1007/978-1-4419-0754-7_7 · Cited by 5
Functional Connectivity Map of Retinal Ganglion Cells for Retinal Prosthesis
Ye, J. H., Ryu, S. B., Kim, K. H., & Goo, Y. S. (2008) · Korean Journal of Physiology and Pharmacology · doi:10.4196/kjpp.2008.12.6.307 · Cited by 5
Kameneva, T., Zarelli, D., Nešić, D., Grayden, D. B., Burkitt, A. N., & Hamish Meffin, A. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2014.07.015 · Cited by 5
Spatial characterization of electric potentials generated by pulsed microelectrode arrays
Kandagor, V., Cela, C. J., Sanders, C. A., Greenbaum, E., Lazzi, G., Humayun, M. S., Zhou, D. M., Castro, R., Gaikwad, S., & Little, J. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5628058 · Cited by 5
Self-citationSui, X., Han, Z., Zhou, D., & Ren, Q. (2012) · The International Journal of Artificial Organs · doi:10.5301/ijao.5000034 · Cited by 5
Characterization of a light switchable microelectrode array for retinal prosthesis
Zhang, X., Xiong, T., Chiou, P.-Y. E., & Li, Z. (2011) · Applied Physics Letters · doi:10.1063/1.3670299 · Cited by 5
Çelik, M. E., & Karagoz, I. (2017) · Arabian Journal for Science and Engineering · doi:10.1007/s13369-017-2918-z · Cited by 5
Fernández, E., & Hoffmann, K. (2011) · Springer eBooks · doi:10.1007/978-3-540-74658-4_41 · Cited by 5
Recent advances in SiC biomedical devices
Saddow, S. E. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-90609-8.00006-5 · Cited by 5
How to Restore Reading With Visual Prostheses
Sommerhalder, J. (2007) · Humana Press eBooks · doi:10.1007/978-1-59745-449-0_3 · Cited by 5
Brain-Machine Interfaces: Restoring and Establishing Communication Channels
Rodenkirch, C., Schriver, B. J., & Wang, Q. (2016) · Springer eBooks · doi:10.1007/978-3-319-31433-4_8 · Cited by 5
Evaluation of effects of electrical stimulation in the retina with optical coherence tomography
Gonzalez-Calle, A., & Weiland, J. D. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7592140 · Cited by 5
Self-citationEstimation of Simulated Phosphene Size Based on Tactile Perception
Lü, Y., Chen, P., Zhao, Y., Shi, J., Ren, Q., & Chai, X. (2011) · Artificial Organs · doi:10.1111/j.1525-1594.2011.01288.x · Cited by 5
Beyond Basic Research for Inherited and Orphan Retinal Diseases: Successes and Challenges
Chader, G. J. (2005) · Retina · doi:10.1097/00006982-200512001-00006 · Cited by 5
Fabrication of flexible 3D microelectrode aray with parylene-based pattern transfer technique
Huang, X., Wang, R., Wang, W., & Li, Z. (2009) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.2009.5285521 · Cited by 5
Cao, X., Li, H., Lu, Z., Chai, X., & Wang, J. (2017) · International Congress on Image and Signal Processing (CISP) · doi:10.1109/cisp-bmei.2017.8302244 · Cited by 5
Nayagam, D. A. X., McGowan, C. C., Villalobos, J., Williams, R. A., Rosa, C. M. S.-L., McKelvie, P. A., Lo, I., Basa, M., Tan, J., & Williams, C. E. (2013) · Journal of Visualized Experiments · doi:10.3791/50411-v · Cited by 5
A visual prosthesis based on Optic Nerve Stimulation: In vivo Electrophysiological Study in Rabbits
Li, L., Sun, M., Cao, P., Cai, C., Chai, X., Li, X., Chen, P., & Ren, Q. (2008) · Springer eBooks · doi:10.1007/978-3-540-79039-6_15 · Cited by 5
Spatial-, Temporal-, and Contrast-Resolutions Obtainable With Retina Implants
Eckhorn, R. (2007) · Humana Press eBooks · doi:10.1007/978-1-59745-449-0_2 · Cited by 5
Mobility enhancement using simulated artificial human vision
Dowling, J. (2007) · Cited by 5
Nanotechnologies in medical devices
Re, G., Mvdz, P., Cf, P., Roszek, B., van der Stijl, R., & de Jong, W. (2015) · Rivm (National Institute for Public Health and the Environment) · Cited by 5
Sanders, C. A., van Nagler, E., Zhou, D. M., & Greenbaum, E. (2007) · Biological and medical physics series · doi:10.1007/978-0-387-49331-2_11 · Cited by 4
Retinal prosthesis: a comprehensive review
Menia, N. K., & Venkatesh, P. (2025) · Expert Review of Ophthalmology · doi:10.1080/17469899.2025.2474064 · Cited by 4
Image processing for visual prostheses: A clinical perspective
Ayton, L. N., Luu, C. D., Bentley, S. A., Allen, P. J., & Guymer, R. H. (2013) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2013.6738317 · Cited by 4
Electrochemical Properties of Sputtered Ruthenium Oxide Neural Stimulation and Recording Electrodes
Chakraborty, B. (2023) · Electrochem · doi:10.3390/electrochem4030023 · Cited by 5
COMPUTER-CONTROLLED NEUROSTIMULATION FOR A VISUAL IMPLANT
Romero, S., Morillas, C., Pelayo, F., & Fernández, E. (2008) · International Conference on Biomedical Electronics and Devices · doi:10.5220/0001051600840091 · Cited by 4
Optimized single pulse stimulation strategy for retinal implants
Savage, C. O., Grayden, D. B., Hamish Meffin, A., & Burkitt, A. N. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/1/016003 · Cited by 5
Palagani, Y., Lee, Y. R., & Choi, J. R. (2018) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2018.8351407 · Cited by 4
Application of Biocompatible Organic/Inorganic Composite Film in Implantable Retinal Prosthesis
Zhao, S., Feng, Y., Wu, T., & Yang, C. (2018) · IEEE International Conference on Cyborg and Bionic Systems (CBS) · doi:10.1109/cbs.2018.8612183 · Cited by 4
Reading Visual Braille with a Retinal Prosthesis
Lauritzen, T. Z., Harris, J., Mohand‐Saïd, S., Sahel, J., Dorn, J. D., McClure, K., & Greenberg, R. J. (2014) · Biosystems & biorobotics · doi:10.1007/978-3-642-54707-2_4 · Cited by 4
Self-citationGekeler, F., Peter, S., Ulrich, K., & Sachs, H. G. (2010) · Cited by 4
Sileo, L., Martiradonna, L., Arcuti, P., Monti, G., Tasco, V., Maschio, M. D., Pruzzo, G., Bozzini, B., Tarricone, L., & Vittorio, M. D. (2013) · Microelectronic Engineering · doi:10.1016/j.mee.2013.02.089 · Cited by 4
A composite insulation structure for silicon-based planar neuroprobes
Zhao, H., Pei, W., Chen, S., Gui, Q., Tang, R., Guo, K., & Chen, H. (2012) · Science China Technological Sciences · doi:10.1007/s11431-012-4856-z · Cited by 4
A Flexible Electrode Driver Using 65 nm CMOS Process for 1024-Electrode Epi-Retinal Prosthesis
Tran, N., Yang, J., Bai, S., Skafidas, E. S., Mareels, I., Ng, D. C., & Halpern, M. E. (2010) · International Conference on Future Information Technology · doi:10.1109/futuretech.2010.5482677 · Cited by 4
A Prototype Retinal Prosthesis for Visual Stimulation
Abu‐Faraj, Z. O., Rjeily, D. M. A., Nasreddine, R. W. B., Andari, M. A., & Taok, H. H. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353659 · Cited by 4
The Development of Visual Prosthetic Devices to Restore Vision to the Blind
Memon, M. A., & Rizzo, J. F. (2009) · Elsevier eBooks · doi:10.1016/b978-0-12-374248-3.00060-4 · Cited by 4
Ultrafast pressure sensing with transient tunnelling currents
Chauhan, A. S., Taylor-Harrod, I., Littlejohn, S. D., & Nogaret, A. (2017) · Nanoscale · doi:10.1039/c7nr01214d · Cited by 4
Coletti, C., Jaroszeski, M. J., Hoff, A., & Saddow, S. E. (2011) · Elsevier eBooks · doi:10.1016/b978-0-12-385906-8.00004-0 · Cited by 4
Weitz, A. C., & Weiland, J. D. (2014) · Springer eBooks · doi:10.1007/978-1-4614-8151-5_7 · Cited by 4
Self-citationA Retinal Implant System Based on Flexible Polymer Microelectrode Array for Electrical Stimulation
Seo, J.-M., Zhou, J., Kim, E., Koo, K.-I., Ye, J. H., Kim, S. J., Chung, H., Cho, D., Goo, Y. S., & Yu, Y. S. (2007) · Humana Press eBooks · doi:10.1007/978-1-59745-449-0_8 · Cited by 4
Subretinal implantation: a step forward to restoring dying photoreceptors
Narfström, K. L. (2007) · Expert Review of Ophthalmology · doi:10.1586/17469899.2.4.521 · Cited by 4
Niu, X., Qiu, Y., Tong, S., & Zhu, Y. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353664 · Cited by 5
Metadata
- Authors
- Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., & de Juan, E.
- Affiliations
- University of Southern California (US)
- Second Sight Medical Products (US)
- Johns Hopkins University (US)
- Corresponding author
- Humayun, Mark S.
- Venue
- Vision Research
- Publisher
- Elsevier BV
- Published
- 2003-11
- Volume
- 43
- Issue
- 24
- Pages
- 2573-2581
- ISSN
- 0042-6989 (ISSN-L)
- OpenAlex
- W2131773286
- Cited by
- 856
- References
- 21
- Citations by year
- 2026: 11 · 2025: 14 · 2024: 15 · 2023: 13 · 2022: 26 · 2021: 23 · 2020: 20 · 2019: 26 · 2018: 22 · 2017: 32 · 2016: 36 · 2015: 31 · 2014: 46 · 2013: 62 · 2012: 52
- FWCI
- 15.48
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Vision Research (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- National Eye Institute (R01EY012843)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
- Keywords
- retinal prosthesis, visual perception, platinum electrode, light perception, motion detection, shape recognition, chronic implantation
- MeSH terms
- Aged, Blindness, Electrodes, Implanted, Humans, Male, Photoreceptor Cells, Retina, Retinitis Pigmentosa, Visual Perception, Treatment Outcome, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review