The DOI matches its Crossref record; 20 of the 21 references it cites were found in a registry or an index.
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Open accessAbstract
A retinal prosthesis was permanently implanted in the eye of a completely blind test subject. This report details the results from the first 10 weeks of testing with the implant subject. The implanted device included an extraocular case to hold electronics, an intraocular electrode array (platinum disks, 4 x 4 arrangement) designed to interface with the retina, and a cable to connect the electronics case to the electrode array. The subject was able to see perceptions of light (spots) on all 16 electrodes of the array. In addition, the subject was able to use a camera to detect the presence or absence of ambient light, to detect motion, and to recognize simple shapes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Due to axonal activation, phosphenes often appear with an elongated shape distorting the image perceived by the patient [46].”
From Advances in visual prostheses: engineering and biological challenges (2022) · cites this paper as [46]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prevalence of age-related maculopathy
Klein, R., Klein, B. E. K., & Linton, K. L. P. (1992) · Ophthalmology · doi:10.1016/s0161-6420(92)31871-8 · Cited by 1,845
The Five-year Incidence and Progression of Age-related Maculopathy
Klein, R., Klein, R., Jensen, S. C., & Meuer, S. M. (1997) · Ophthalmology · doi:10.1016/s0161-6420(97)30368-6 · Cited by 1,154
Will Retinal Implants Restore Vision?
Zrenner, E. (2002) · Science · doi:10.1126/science.1067996 · Cited by 736
Preservation of the Inner Retina in Retinitis Pigmentosa
Santos, A. (1997) · Archives of Ophthalmology · doi:10.1001/archopht.1997.01100150513011 · Cited by 651
Visual Perception Elicited by Electrical Stimulation of Retina in Blind Humans
Humayun, M. S. (1996) · Archives of Ophthalmology · doi:10.1001/archopht.1996.01100130038006 · Cited by 602
Self-citationPattern electrical stimulation of the human retina
Humayun, M. S., de Juan, E., Weiland, J. D., Dagnelie, G., Katona, S., Greenberg, R. J., & Suzuki, S. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00052-8 · Cited by 598
Self-citationMorphometric analysis of the extramacular retina from postmortem eyes with retinitis pigmentosa.
Humayun, M. S., Prince, M. R., de Juan, E., Barrón, Y., Moskowitz, M., Klock, I. B., & Milam, A. H. (1999) · PubMed · Cited by 366
Self-citationNeural prostheses : fundamental studies
Agnew, W. F., & McCreery, D. B. (1990) · Medical Entomology and Zoology · Cited by 316
Learning Retina Implants with Epiretinal Contacts
Eckmiller, R. (2009) · Ophthalmic Research · doi:10.1159/000268026 · Cited by 257
Subretinal electrical stimulation of the rabbit retina
Chow, A. Y., & Chow, V. Y. (1997) · Neuroscience Letters · doi:10.1016/s0304-3940(97)00185-7 · Cited by 242
Cited by
Sorted by citations
Items 101–200 of 855
The Evolution of Neuroprosthetic Interfaces
Adewole, D. O., Serruya, M. D., Harris, J. P., Burrell, J. C., Petrov, D., Chen, H.-C. I., Wolf, J. A., & Cullen, D. K. (2016) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2016017198 · Cited by 86
Bioengineering strategies for restoring vision
Cehajic-Kapetanovic, J., Singh, M. S., Zrenner, E., & MacLaren, R. E. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00836-4 · Cited by 79
Ong, J. M., & da Cruz, L. (2011) · Clinical and Experimental Ophthalmology · doi:10.1111/j.1442-9071.2011.02590.x · Cited by 79
A method and technical equipment for an acute human trial to evaluate retinal implant technology
Hornig, R., Laube, T., Walter, P., Velikay‐Parel, M., Bornfeld, N., Feucht, M., Akguel, H., Rößler, G., Alteheld, N., Notarp, D. L., et al. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/014 · Cited by 77
Laser patterning of platinum electrodes for safe neurostimulation
Green, R. A., Matteucci, P. B., Dodds, C. W. D., Palmer, J., Dueck, W. F., Hassarati, R. T., Byrnes-Preston, P., Lovell, N. H., & Suaning, G. J. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056017 · Cited by 77
Bionic vision: system architectures – a review
Guenther, T., Lovell, N. H., & Suaning, G. J. (2011) · Expert Review of Medical Devices · doi:10.1586/erd.11.58 · Cited by 78
Retinal Prostheses for the Blind
Javaheri, M., Hahn, D., Lakhanpal, R. R., Weiland, J. D., & Humayun, M. S. (2006) · Annals of the Academy of Medicine Singapore · doi:10.47102/annals-acadmedsg.v35n3p137 · Cited by 76
Self-citationNanobionics: the impact of nanotechnology on implantable medical bionic devices
Wallace, G. G., Higgins, M. J., Moulton, S. E., & Wang, C. (2012) · Nanoscale · doi:10.1039/c2nr30758h · Cited by 75
Ayton, L. N., Rizzo, J. F., Bailey, I. L., Colenbrander, A., Dagnelie, G., Geruschat, D. R., Hessburg, P. C., McCarthy, C. D., Petoe, M. A., Rubin, G. S., et al. (2020) · Translational Vision Science & Technology · doi:10.1167/tvst.9.8.25 · Cited by 75
Self-citationGekeler, F., Szurman, P., Grisanti, S., Weiler, U., Claus, R., Greiner, T.-O., Völker, M., Köhler, K., Zrenner, E., & Bartz‐Schmidt, K. U. (2006) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-006-0339-x · Cited by 75
Zhou, J., Woo, S. J., Park, S. I., Kim, E., Seo, J.-M., Chung, H., & Kim, S. J. (2008) · BioMed Research International · doi:10.1155/2008/547428 · Cited by 74
Mutashar, S., Hannan, M. A., Samad, S. A., & Hussain, A. (2014) · Italian National Conference on Sensors · doi:10.3390/s140711522 · Cited by 78
Architecture tradeoffs in high-density microstimulators for retinal prosthesis
Sivaprakasam, M., Liu, W., Wang, G., Weiland, J. D., & Humayun, M. S. (2005) · IEEE Transactions on Circuits and Systems I Fundamental Theory and Applications · doi:10.1109/tcsi.2005.857554 · Cited by 74
Self-citationSites of neuronal excitation by epiretinal electrical stimulation
Schiefer, M. A., & Grill, W. M. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.870488 · Cited by 72
Stimulation strategies for improving the resolution of retinal prostheses
Tong, W., Meffin, H., Garrett, D. J., & Ibbotson, M. R. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00262 · Cited by 66
Encoding visual information in retinal ganglion cells with prosthetic stimulation
Freeman, D. K., Rizzo, J. F., & Fried, S. I. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/035005 · Cited by 71
Microstimulation of visual cortex to restore vision
Tehovnik, E. J., Slocum, W. M., Smirnakis, S. M., & Tolias, A. S. (2009) · Progress in Brain Research · doi:10.1016/s0079-6123(09)17524-6 · Cited by 71
Attaining higher resolution visual prosthetics: a review of the factors and limitations
Eiber, C. D., Lovell, N. H., & Suaning, G. J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/1/011002 · Cited by 71
Intraocular retinal prosthesis
Weiland, J. D., & Humayun, M. S. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2006.1705748 · Cited by 73
Self-citationSensory rehabilitation in the plastic brain
Collignon, O., Champoux, F., Voss, P., & Leporé, F. (2011) · Progress in brain research · doi:10.1016/b978-0-444-53752-2.00003-5 · Cited by 75
Fornos, A. P., Sommerhalder, J., Rappaz, B., Safran, A. B., & Pelizzone, M. (2005) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.04-1173 · Cited by 69
Dagnelie, G. (2011) · Current Opinion in Neurology · doi:10.1097/wco.0b013e32834f02c3 · Cited by 71
Self-citationEffective Electrode Configuration for Selective Stimulation With Inner Eye Prostheses
Rattay, F., & Resatz, S. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.828044 · Cited by 70
Yamauchi, Y., Franco, L. M., Jackson, D., Naber, J. F., Ziv, R. O., Rizzo, J. F., Kaplan, H. J., & Enzmann, V. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/007 · Cited by 71
Laser bonded microjoints between titanium and polyimide for applications in medical implants
Mian, A., Newaz, G. M., Vendra, L., Rahman, N. M., Georgiev, D. G., Auner, G. W., Witte, R., & Herfurth, H. (2005) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-005-6684-1 · Cited by 69
Acute electrical stimulation of the human retina with an epiretinal electrode array
Keserü, M., Feucht, M., Bornfeld, N., Laube, T., Walter, P., Rößler, G., Velikay‐Parel, M., Hornig, R., & Richard, G. W. (2011) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.2011.02288.x · Cited by 69
The IMI Retinal Implant System
Hornig, R., Zehnder, T., Velikay‐Parel, M., Laube, T., Feucht, M., & Richard, G. W. (2007) · Springer eBooks · doi:10.1007/978-0-387-49331-2_6 · Cited by 69
Palanker, D., Huie, P., Vankov, A., Aramant, R. B., Seiler, M. J., Fishman, H. A., Marmor, M. F., & Blumenkranz, M. S. (2004) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.03-1327 · Cited by 69
Medical implants based on microsystems
Mokwa, W. (2007) · Measurement Science and Technology · doi:10.1088/0957-0233/18/5/r01 · Cited by 68
Ten-Year Follow-up of a Blind Patient Chronically Implanted with Epiretinal Prosthesis Argus I
Lan, Y., Falabella, P., Christopher, P., Wuyyuru, V., Dorn, J. D., Schor, P., Greenberg, R. J., Weiland, J. D., & Humayun, M. S. (2015) · Ophthalmology · doi:10.1016/j.ophtha.2015.08.008 · Cited by 67
Self-citationProsthetic interfaces with the visual system: biological issues
Cohen, E. D. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r02 · Cited by 67
Silicon Carbide Technology for Advanced Human Healthcare Applications
Saddow, S. E. (2022) · Micromachines · doi:10.3390/mi13030346 · Cited by 66
Djilas, M., Olès, C., Lorach, H., Bendali, A., Dégardin, J., Dubus, É., Lissorgues, G., Rousseau, L., Benosman, R. B., Ieng, S.-H., et al. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046020 · Cited by 65
Im, M., & Fried, S. I. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/025002 · Cited by 65
Semantic and structural image segmentation for prosthetic vision
Sanchez-Garcia, M., Martinez-Cantin, R., & Guerrero, J. J. (2020) · PLOS ONE · doi:10.1371/journal.pone.0227677 · Cited by 62
Wang, R., Huang, X., Liu, G., Wang, W., Dong, F., & Li, Z. (2010) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2009.2039773 · Cited by 63
DeMarco, P. J., Yarbrough, G. L., Yee, C. W., McLean, G. Y., Sagdullaev, B. T., Ball, S. L., & McCall, M. A. (2007) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.06-0811 · Cited by 64
Villalobos, J., Nayagam, D. A. X., Allen, P. J., McKelvie, P., Luu, C. D., Ayton, L. N., Freemantle, A. L., McPhedran, M., Basa, M., McGowan, C. C., et al. (2013) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.12-10843 · Cited by 63
Visual acuity measurement of prosthetic vision: a virtual-reality simulation study
Chen, S. C., Hallum, L. E., Lovell, N. H., & Suaning, G. J. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/015 · Cited by 64
Gautam, V., Bag, M., & Narayan, K. S. (2011) · Journal of the American Chemical Society · doi:10.1021/ja207853e · Cited by 63
Bergonzo, P., Bongrain, A., Scorsone, E., Bendali, A., Rousseau, L., Lissorgues, G., Mailley, P., Li, Y., Kauffmann, T., Goy, F., et al. (2011) · IRBM · doi:10.1016/j.irbm.2011.01.032 · Cited by 63
Cheng, D. L., Greenberg, P. B., & Borton, D. A. (2017) · Current Eye Research · doi:10.1080/02713683.2016.1270326 · Cited by 65
A review of in vivo animal studies in retinal prosthesis research
Bertschinger, D. R., Beknazar, E., Simonutti, M., Safran, A. B., Sahel, J., Rosolen, S. G., Picaud, S. A., & Salzmann, J. (2008) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-008-0891-7 · Cited by 62
Ectopic eyes outside the head inXenopustadpoles provide sensory data for light-mediated learning
Blackiston, D. J., & Levin, M. G. (2013) · Journal of Experimental Biology · doi:10.1242/jeb.074963 · Cited by 64
Possible sources of neuroprotection following subretinal silicon chip implantation in RCS rats
Pardue, M. T., Phillips, M. J., Yin, H., Fernandes, A., Cheng, Y. C., Chow, A. Y., & Ball, S. L. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/006 · Cited by 62
The appearance of phosphenes elicited using a suprachoroidal retinal prosthesis
Sinclair, N. C., Shivdasani, M. N., Perera, T., Gillespie, L. N., McDermott, H. J., Ayton, L. N., Blamey, P. J., & for the Bionic Vision Australia Consortium (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.15-18991 · Cited by 60
Use of the Argus II Retinal Prosthesis to Improve Visual Guidance of Fine Hand Movements
Barry, M. P., & Dagnelie, G. (2012) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.12-9536 · Cited by 60
Self-citationChow, A. Y., Bittner, A. K., & Pardue, M. T. (2010) · PubMed Central · Cited by 60
Morimoto, T., Fukui, T., Matsushita, K., Okawa, Y., Shimojyo, H., Kusaka, S., Tano, Y., & Fujikado, T. (2006) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-006-0260-3 · Cited by 60
Simulating prosthetic vision: II. Measuring functional capacity
Chen, S. C., Suaning, G. J., Morley, J. W., & Lovell, N. H. (2009) · Vision Research · doi:10.1016/j.visres.2009.07.003 · Cited by 59
Li, H., Su, X., Wang, J., Kan, H., Han, T., Zeng, Y., & Chai, X. (2018) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2017.11.001 · Cited by 59
Kernel Methods on Spike Train Space for Neuroscience: A Tutorial
Park, I. M., Seth, S., Paiva, A. R. C., Li, L., & Príncipe, J. C. (2013) · IEEE Signal Processing Magazine · doi:10.1109/msp.2013.2251072 · Cited by 59
Stett, A., Mai, A., & Herrmann, T. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/1/s02 · Cited by 59
Sakaguchi, H., Kamei, M., Fujikado, T., Yonezawa, E., Ozawa, M., Cecilia-Gonzalez, C., Ustariz-Gonzalez, O., Quiroz-Mercado, H., & Tano, Y. (2009) · Journal of Artificial Organs · doi:10.1007/s10047-009-0467-2 · Cited by 58
Contemporary approaches to visual prostheses
Mirochnik, R. M., & Pezaris, J. S. (2019) · Military Medical Research · doi:10.1186/s40779-019-0206-9 · Cited by 58
Electric stimulus duration alters network-mediated responses depending on retinal ganglion cell type
Im, M., Werginz, P., & Fried, S. I. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaadc1 · Cited by 62
Dowling, J. (2005) · Expert Review of Medical Devices · doi:10.1586/17434440.2.1.73 · Cited by 58
Eleftheriou, C. G., Zimmermann, J. B., Kjeldsen, H. D., David‐Pur, M., Hanein, Y., & Sernagor, E. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.10.018 · Cited by 57
Vision rehabilitation in the case of blindness
Veraart, C., Duret, F., Brelen, M. E., Oozeer, M., & Delbeke, J. (2004) · Expert Review of Medical Devices · doi:10.1586/17434440.1.1.139 · Cited by 56
Schanze, T., Hesse, L., Lau, C., Greve, N., Haberer, W., Kammer, S., Doerge, T., Rentzos, A., & Stieglitz, T. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.895866 · Cited by 57
Task-Dependent V1 Responses in Human Retinitis Pigmentosa
Masuda, Y., Horiguchi, H., Dumoulin, S. O., Furuta, A., Miyauchi, S., Nakadomari, S., & Wandell, B. A. (2010) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.09-4775 · Cited by 63
VanDersarl, J. J., Mercanzini, A., & Renaud, P. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201402934 · Cited by 57
Transcorneal Electrical Stimulation Shows Neuroprotective Effects in Retinas of Light-Exposed Rats
Schatz, A., Arango‐González, B., Fischer, D., Enderle, H., Bolz, S., Röck, T., Naycheva, L., Grimm, C., Messias, A. M. V., Zrenner, E., et al. (2012) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.12-10037 · Cited by 56
Stem cells as a therapeutic tool for the blind: biology and future prospects
Singh, M. S., & MacLaren, R. E. (2011) · Proceedings of the Royal Society B Biological Sciences · doi:10.1098/rspb.2011.1028 · Cited by 57
Electrical properties of retinal–electrode interface
Shah, S., Hines, A., Zhou, D. D., Greenberg, R. J., Humayun, M. S., & Weiland, J. D. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/1/s04 · Cited by 55
Self-citationKasi, H., Hasenkamp, W., Cosendai, G., Bertsch, A., & Renaud, P. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-44 · Cited by 55
High resolution optical coherence elastography of retina under prosthetic electrode
Li, R., Du, Z., Qian, X., Li, Y., Martínez-Camarillo, J.-C., Jiang, L., Humayun, M. S., Chen, Z., & Zhou, Q. (2020) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-20-1137 · Cited by 56
Self-citationA CMOS retinal neurostimulator capable of focussed, simultaneous stimulation
Dommel, N., Wong, Y. T., Lehmann, T., Dodds, C. W. D., Lovell, N. H., & Suaning, G. J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/035006 · Cited by 54
Analysis and Optimization of Four-Coil Planar Magnetically Coupled Printed Spiral Resonators
Khan, S., & Choi, G.-S. (2016) · Italian National Conference on Sensors · doi:10.3390/s16081219 · Cited by 52
Humayun, M. S., de Juan, E., & Dagnelie, G. (2016) · Ophthalmology · doi:10.1016/j.ophtha.2016.06.044 · Cited by 56
Self-citationSilicon LSI-based smart stimulators for retinal prosthesis
Ohta, J., Tokuda, T., Kagawa, K., Furumiya, T., Uehara, A., Terasawa, Y., Ozawa, M., Fujikado, T., & Tano, Y. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2006.1705747 · Cited by 54
Luo, Y. H.-L., Zhong, J. J., Clemo, M., & da Cruz, L. (2016) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2016.07.021 · Cited by 47
Conducting Polymers in Neural Stimulation Applications
Zhou, D. D., Cui, X. T., Hines, A., & Greenberg, R. J. (2009) · Biological and medical physics series · doi:10.1007/978-0-387-98120-8_8 · Cited by 55
Self-citationNau, A. C., Bach, M., & Fisher, C. (2013) · Translational Vision Science & Technology · doi:10.1167/tvst.2.3.1 · Cited by 54
Controlled delivery for neuro-bionic devices
Yue, Z., Moulton, S. E., Cook, M. J., O’Leary, S. J., & Wallace, G. G. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.06.002 · Cited by 56
Development of a micromachined epiretinal vision prosthesis
Stieglitz, T. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/6/065005 · Cited by 54
Towards high-resolution retinal prostheses with direct optical addressing and inductive telemetry
Ha, S., Khraiche, M. L., Akinin, A., Jing, Y., Damle, S., Kuang, Y. J., Bauchner, S., Lo, Y., Freeman, W. R., Silva, G. A., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/5/056008 · Cited by 52
Neural stimulation for visual rehabilitation: Advances and challenges
Lorach, H., Marre, O., Sahel, J., Benosman, R. B., & Picaud, S. A. (2012) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2012.10.003 · Cited by 57
Stem-cell therapy in retinal disease
Baker, P. S., & Brown, G. C. (2009) · Current Opinion in Ophthalmology · doi:10.1097/icu.0b013e328329b5f2 · Cited by 52
Abramian, M., Lovell, N. H., Morley, J. W., Suaning, G. J., & Dokos, S. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/035004 · Cited by 52
Blackiston, D. J., Anderson, G. M., Rahman, N., Bieck, C., & Levin, M. G. (2014) · Neurotherapeutics · doi:10.1007/s13311-014-0317-7 · Cited by 52
Maeng, J., Chakraborty, B., Geramifard, N., Kang, T. H., Rihani, R. T., Joshi‐Imre, A., & Cogan, S. F. (2019) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.34442 · Cited by 51
Fornos, A. P., Sommerhalder, J., Pittard, A., Safran, A. B., & Pelizzone, M. (2008) · Vision Research · doi:10.1016/j.visres.2008.04.027 · Cited by 50
Temporal interactions during paired-electrode stimulation in two retinal prosthesis subjects
Horsager, A., Boynton, G. M., Greenberg, R. J., & Fine, I. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-5282 · Cited by 48
Self-citationInterphase gap as a means to reduce electrical stimulation thresholds for epiretinal prostheses
Weitz, A. C., Behrend, M. R., Ahuja, A., Christopher, P., Wei, J., Wuyyuru, V., Patel, U. K., Greenberg, R. J., Humayun, M. S., Chow, R. H.-P., et al. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/1/016007 · Cited by 51
Self-citationWang, Q., Millard, D. C., Zheng, H. J. V., & Stanley, G. B. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026008 · Cited by 51
Retinal ganglion cell responses to voltage and current stimulation in wild-type andrd1mouse retinas
Goo, Y. S., Ye, J. H., Lee, S., Nam, Y., Ryu, S. B., & Kim, K. H. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/035003 · Cited by 50
Mobility and low contrast trip hazard avoidance using augmented depth
McCarthy, C., Walker, J. G., Lieby, P., Scott, A., & Barnes, N. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016003 · Cited by 49
Bionic eye review - An update.
Nowik, K., Langwińska-Wośko, E., Skopiński, P., Nowik, K. E., & Szaflik, J. P. (2020) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2020.05.041 · Cited by 49
Srivastava, N. R., Troyk, P. R., & Dagnelie, G. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/035008 · Cited by 45
Self-citationAn update on visual prosthesis
Ramirez, K. A., Drew-Bear, L. E., Vega-Garces, M. I., Belandria, H. B., & Arévalo, J. F. (2023) · International Journal of Retina and Vitreous · doi:10.1186/s40942-023-00498-1 · Cited by 49
Lorach, H., Benosman, R. B., Marre, O., Ieng, S.-H., Sahel, J., & Picaud, S. A. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/6/066004 · Cited by 49
Late histological and functional changes in the P23H rat retina after photoreceptor loss
Kolomiets, B. P., Dubus, É., Simonutti, M., Rosolen, S. G., Sahel, J., & Picaud, S. A. (2010) · Neurobiology of Disease · doi:10.1016/j.nbd.2009.12.025 · Cited by 49
Wireless technologies for closed-loop retinal prostheses
Ng, D. C., Bai, S., Yang, J., Tran, N., & Skafidas, E. S. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/6/065004 · Cited by 48
Retinal prostheses: Clinical results and future challenges
Picaud, S. A., & Sahel, J. (2014) · Comptes Rendus Biologies · doi:10.1016/j.crvi.2014.01.001 · Cited by 48
Simulation of thalamic prosthetic vision: reading accuracy, speed, and acuity in sighted humans
Vurro, M., Crowell, A. M., & Pezaris, J. S. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00816 · Cited by 47
Advances in Micro/Nano Electromechanical Systems and Fabrication Technologies
Takahata, K. (2013) · InTech eBooks · doi:10.5772/46117 · Cited by 48
Zhao, Y., Lü, Y., Tian, Y., Li, L., Ren, Q., & Chai, X. (2010) · Information Sciences · doi:10.1016/j.ins.2010.04.021 · Cited by 47
Predictable irregularities in retinal receptive fields
Liu, Y. S., Stevens, C. F., & Sharpee, T. O. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0908926106 · Cited by 47
Vision function testing for a suprachoroidal retinal prosthesis: effects of image filtering
Barnes, N., Scott, A. F., Lieby, P., Petoe, M. A., McCarthy, C., Stacey, A., Ayton, L. N., Sinclair, N. C., Shivdasani, M. N., Lovell, N. H., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036013 · Cited by 46
Metadata
- Authors
- Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., & de Juan, E.
- Affiliations
- University of Southern California (US)
- Second Sight Medical Products (US)
- Johns Hopkins University (US)
- Corresponding author
- Humayun, Mark S.
- Venue
- Vision Research
- Publisher
- Elsevier BV
- Published
- 2003-11
- Volume
- 43
- Issue
- 24
- Pages
- 2573-2581
- ISSN
- 0042-6989 (ISSN-L)
- OpenAlex
- W2131773286
- Cited by
- 856
- References
- 21
- Citations by year
- 2026: 11 · 2025: 14 · 2024: 15 · 2023: 13 · 2022: 26 · 2021: 23 · 2020: 20 · 2019: 26 · 2018: 22 · 2017: 32 · 2016: 36 · 2015: 31 · 2014: 46 · 2013: 62 · 2012: 52
- FWCI
- 15.48
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Vision Research (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- National Eye Institute (R01EY012843)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
- Keywords
- retinal prosthesis, visual perception, platinum electrode, light perception, motion detection, shape recognition, chronic implantation
- MeSH terms
- Aged, Blindness, Electrodes, Implanted, Humans, Male, Photoreceptor Cells, Retina, Retinitis Pigmentosa, Visual Perception, Treatment Outcome, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review