Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Open accessAbstract
A retinal prosthesis was permanently implanted in the eye of a completely blind test subject. This report details the results from the first 10 weeks of testing with the implant subject. The implanted device included an extraocular case to hold electronics, an intraocular electrode array (platinum disks, 4 x 4 arrangement) designed to interface with the retina, and a cable to connect the electronics case to the electrode array. The subject was able to see perceptions of light (spots) on all 16 electrodes of the array. In addition, the subject was able to use a camera to detect the presence or absence of ambient light, to detect motion, and to recognize simple shapes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Due to axonal activation, phosphenes often appear with an elongated shape distorting the image perceived by the patient [46].”
From Advances in visual prostheses: engineering and biological challenges (2022) · cites this paper as [46]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prevalence of age-related maculopathy
Klein, R., Klein, B. E. K., & Linton, K. L. P. (1992) · Ophthalmology · doi:10.1016/s0161-6420(92)31871-8 · Cited by 1,845
The Five-year Incidence and Progression of Age-related Maculopathy
Klein, R., Klein, R., Jensen, S. C., & Meuer, S. M. (1997) · Ophthalmology · doi:10.1016/s0161-6420(97)30368-6 · Cited by 1,154
Will Retinal Implants Restore Vision?
Zrenner, E. (2002) · Science · doi:10.1126/science.1067996 · Cited by 736
Preservation of the Inner Retina in Retinitis Pigmentosa
Santos, A. (1997) · Archives of Ophthalmology · doi:10.1001/archopht.1997.01100150513011 · Cited by 651
Visual Perception Elicited by Electrical Stimulation of Retina in Blind Humans
Humayun, M. S. (1996) · Archives of Ophthalmology · doi:10.1001/archopht.1996.01100130038006 · Cited by 602
Self-citationPattern electrical stimulation of the human retina
Humayun, M. S., de Juan, E., Weiland, J. D., Dagnelie, G., Katona, S., Greenberg, R. J., & Suzuki, S. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00052-8 · Cited by 598
Self-citationMorphometric analysis of the extramacular retina from postmortem eyes with retinitis pigmentosa.
Humayun, M. S., Prince, M. R., de Juan, E., Barrón, Y., Moskowitz, M., Klock, I. B., & Milam, A. H. (1999) · PubMed · Cited by 366
Self-citationNeural prostheses : fundamental studies
Agnew, W. F., & McCreery, D. B. (1990) · Medical Entomology and Zoology · Cited by 316
Learning Retina Implants with Epiretinal Contacts
Eckmiller, R. (2009) · Ophthalmic Research · doi:10.1159/000268026 · Cited by 257
Subretinal electrical stimulation of the rabbit retina
Chow, A. Y., & Chow, V. Y. (1997) · Neuroscience Letters · doi:10.1016/s0304-3940(97)00185-7 · Cited by 242
Cited by
Sorted by citations
Items 701–800 of 855
Dynamic intrinsic optical signal monitoring of electrically stimulated inner retinal neural response
Li, Y., Luo, J.-M., Lu, R., Liu, K.-M., Levy, A., & Yao, X.-C. (2012) · Journal of Modern Optics · doi:10.1080/09500340.2012.687464 · Cited by 1
Çelik, M. E., & Karagoz, I. (2014) · Signal Processing and Communications Applications Conference (SIU) · doi:10.1109/siu.2014.6830211 · Cited by 1
Feature accentuation in phosphenated images
Kiral-Kornek, F. I., Savage, C. O., Grayden, D. B., & Burkitt, A. N. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347340 · Cited by 1
Minimisation of required charge for desired neuronal spike rate
Savage, C. O., Kameneva, T., Grayden, D. B., Hamish Meffin, A., & Burkitt, A. N. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346597 · Cited by 1
Visual Cortex and Extraocular Retinal Stimulation With Surface Electrode Arrays
Morley, J. W., Chowdhury, V., & Coroneo, M. T. (2007) · Humana Press eBooks · doi:10.1007/978-1-59745-449-0_11 · Cited by 1
Übersicht über die Entwicklung des künstlichen Sehens an der Universitäts-Augenklinik Graz
Ivastinović, D., Brandner, M., Georgi, T., Langmann, G., Wedrich, A., & Velikay‐Parel, M. (2009) · Spektrum der Augenheilkunde · doi:10.1007/s00717-009-0356-3 · Cited by 1
Geordi’s Visor: A Vision of the Future
Lasbury, M. E. (2016) · Springer eBooks · doi:10.1007/978-3-319-40914-6_7 · Cited by 1
Observed Similar Behavior of a-Si: H P-I-N Photodiode and Retina Response
Gradišnik, V. (2010) · Control and Intelligent Systems · doi:10.2316/j.2010.216.680-0158 · Cited by 1
A comparative study of light and electrically evoked response of retinal ganglion cells
Biswas, S., Sikdar, D., Das, S., & Mahadevappa, M. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8037020 · Cited by 1
Introduction and Literature Review
Mirabedini, A. (2018) · Springer theses · doi:10.1007/978-3-319-95378-6_1 · Cited by 1
Guo, T., Tsai, D., Muralidharan, M., Li, M., Suaning, G. J., Morley, J. W., Dokos, S., & Lovell, N. H. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512748 · Cited by 2
Bionic Eyes: Vision Restoration Through Electronic or Photovoltaic Stimulation
Ayton, L. N., Guymer, R. H., Allen, P. J., & Luu, C. D. (2014) · Stem cell biology and regenerative medicine · doi:10.1007/978-1-4939-0787-8_13 · Cited by 1
PDF Not Yet Available In IEEE Xplore
Rodger, D. C., Li, W., Fong, A. J., Ameri, H., Meng, E. F., Burdick, J. W., Roy, R. R., Edgerton, V. R., Weiland, J. D., Humayun, M. S., et al. (2006) · International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology (MMB) · doi:10.1109/mmb.2006.251482 · Cited by 1
Self-citationMargalit, E., & Thoreson, W. B. (2007) · xPharm: The Comprehensive Pharmacology Reference · doi:10.1016/b978-008055232-3.60693-2 · Cited by 1
Research on visual sensitivity characteristics of amorphous silicon photocells
Wang, Y., Cai, N., Zhou, X., Lü, Y., Wang, C., & Fan, X. (2024) · Optoelectronics Letters · doi:10.1007/s11801-024-3185-3 · Cited by 1
Response of Human Retinal Networks to Electrical Stimulation using 3D Intra-retinal Microelectrodes
Li, J., Ly, K., Wang, R., Italiano, M. L., Shivdasani, M. N., Tsai, D., Zhang, J., Lovell, N. H., Dokos, S., & Guo, T. (2024) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc53108.2024.10781729 · Cited by 1
A Flexible Thin-film Microelectrode for Optic-Nerve Visual Prosthesis
Sui, X., Li, Y., Xie, Y., Liang, T., Chen, W., Lu, Y., Li, G., Wang, K., & Ren, Q. (2008) · Springer eBooks · doi:10.1007/978-3-540-79039-6_80 · Cited by 1
An Implantable Epiretinal Vision Prosthesis for Retinitis Pigmentosa Patients
Schanze, T., Thomas, U., & The EPIRET-Group (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-03889-1_70 · Cited by 1
An Update on Retinal Stem Cell Therapy
Chao, J. R., & Lamba, D. A. (2013) · Current Ophthalmology Reports · doi:10.1007/s40135-013-0016-2 · Cited by 1
Simulation of electrode-tissue interface for electrical stimulation of retinal ganglion cells
Biswas, S., Das, S., & Mahadevappa, M. (2014) · IEEE International Conference on Electronics, Computing and Communication Technologies (CONECCT) · doi:10.1109/conecct.2014.6740341 · Cited by 1
Retinal neuroprosthesis: science fact or science fiction?
Lovell, N. H., & Suaning, G. J. (2007) · Expert Review of Ophthalmology · doi:10.1586/17469899.2.2.145 · Cited by 1
Portable Biomimetic Retina for Learning, Perception-based Image Acquisition
Eckmiller, R., Schatten, R., & Baruth, O. (2007) · IEEE International Conference on Neural Networks/IEEE ... International Conference on Neural Networks · doi:10.1109/ijcnn.2007.4371340 · Cited by 2
Mathieson, K., Moodie, A. R., Grant, E., & Morrison, J. D. (2012) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2012.719995 · Cited by 1
Effect of Pixel’s Spatial Characteristics on Recognition of Isolated Pixelized Chinese Character
Yang, K., Liu, S., Wang, H., Liu, W., & Wu, Y. (2015) · The Open Biomedical Engineering Journal · doi:10.2174/1874120701509010234 · Cited by 1
A 3D-continuum bidomain model of retinal electrical stimulation using an anatomically detailed mesh
Shalbaf, F., Du, P., Lovell, N. H., Dokos, S., & Vaghefi, E. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318850 · Cited by 1
Sui, X., Shao, Y., Li, L., Chai, X., & Ren, Q. (2011) · Journal of Shanghai Jiaotong University (Science) · doi:10.1007/s12204-011-1198-0 · Cited by 1
Aydin, E., Çelik, M. E., & Aydemir, M. T. (2017) · International Conference on Electrical and Electronics Engineering · Cited by 1
Effect of camera position on egocentric localisation with Simulated Prosthetic Vision
Prabhu, D., Wise, L. Z., MacMahon, C., Man, M. D., Petoe, M. A., & McCarthy, C. D. (2020) · Engineering Research Express · doi:10.1088/2631-8695/abcd51 · Cited by 1
Retrouver une vision (artificielle) grâce aux implants rétiniens
Barale, P. O., Mohand‐Saïd, S., Scheer, S., Haïdar, J., Picaud, S. A., & Sahel, J. (2017) · Photoniques · doi:10.1051/photon/20178531 · Cited by 1
Perspectives and Possibilities in Biomaterials Science
Ratner, B. D., Schöen, F. J., Lemons, J. E., & Hoffman, A. S. (1996) · Elsevier eBooks · doi:10.1016/b978-012582460-6/50014-1 · Cited by 1
Competency of legal subjects in informed consent as a standard agreement
Yohanes, A. S., Ramalinda, D., Pertiwi, L. E., Kumalawijaya, A. P., Rahmawan, F. S., Nurdin, S., Ilyasa, M. F., & Fauzan, H. (2022) · International Journal of Health Sciences · doi:10.53730/ijhs.v6n3.13185 · Cited by 1
Bionic eyes: where are we and what does the future hold?
Ibbotson, M. R. (2012) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2012.00772.x · Cited by 1
Retinal Prosthesis: An Innovative Technology for Treating Blindness
Chen, J. (2008) · North American Journal of Medicine and Science · doi:10.7156/v1i1p020 · Cited by 1
Electronic restoration of vision: science fiction or reality?
Fletcher, E. L., & Greferath, U. (2010) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2010.00450.x · Cited by 1
Electrical excitation of degenerate retina
Chan, L. H. (2009) · ProQuest Demo Repository · Cited by 1
Huang, R. K.-J. (2010) · CaltechTHESIS (California Institute of Technology) · doi:10.7907/vmzb-0n20 · Cited by 1
A Comparison of Two and Three Dimensional Wire Antennas for Biomedical Applications
Soora, S. (2006) · NCSU Libraries Repository (North Carolina State University Libraries) · Cited by 1
Introduction of an implantable MOMES used in visual prosthesis
Zhou, C., Liu, Y., Ren, Q., & Lu, P. (2006) · International Symposium on Biophotonics, Nanophotonics and Metamaterials · doi:10.1109/metamat.2006.335030 · Cited by 1
Johnson, L. J., & Scribner, D. A. (2007) · Humana Press eBooks · doi:10.1007/978-1-59745-449-0_9 · Cited by 1
Jun, O., Tokuda, T., Sasagawa, K., Takeuchi, Y., Nishida, K., Kitaguchi, Y., Kamei, M., Fujikado, T., & Tano, Y. (2009) · 映像情報メディア学会技術報告 · Cited by 1
Retina-Implantate: aktueller Stand des „Artificial Vision“
Velikay‐Parel, M., Ivastinović, D., Hornig, R., Koch, M., Langmann, G., & Langmann, A. (2006) · Spektrum der Augenheilkunde · doi:10.1007/bf03163801 · Cited by 1
In Vitro Determination of Stimulus-Induced pH Changes in Visual Prostheses
Chu, A., Morris, K., Agazaryan, A., Istomin, A., Little, J., Greenberg, R. J., & Zhou, D. (2007) · Springer eBooks · doi:10.1007/978-0-387-49331-2_12 · Cited by 1
Self-citationBlum, A. P. (2011) · CaltechTHESIS (California Institute of Technology) · doi:10.7907/kfpv-jn09 · Cited by 1
Chen, S. C., Hallum, L. E., Wong, Y. T., Dommel, N., Byrnes-Preston, P., Suaning, G. J., & Lovell, N. H. (2010) · Wiley eBooks · doi:10.1002/9780471740360.ebs0080 · Cited by 1
Mechanism of Oscillatory Rhythm of Retinal Ganglion cells in rd1 Mouse Retina
Ye, J. H., Ryu, S. B., Kim, K. H., Rim, B. C., & Goo, Y. S. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-03891-4_70 · Cited by 1
Photogenetic Retinal Prosthesis
Grossman, N. (2010) · Spiral (Imperial College London) · doi:10.25560/6155
Microelectrode Implants for Spinal Cord Stimulation in Rats
Nandra, M. S. (2015) · CaltechTHESIS (California Institute of Technology) · doi:10.7907/z9930r3g
Future Therapies for Retinitis Pigmentosa
Sahel, J., & Marazova, K. (2014) · Springer eBooks · doi:10.1007/978-3-540-69466-3_53
Replicating Physiological Patterns of Activity with Prosthetic Stimulation
Fried, S. I. (2008) · Defense Technical Information Center (DTIC)
Neogi, B., Ghosal, S., Mukherjee, S., Das, A., & Tibarewala, D. N. (2011) · arXiv (Cornell University) · doi:10.48550/arxiv.1111.1684
Dense, Efficient Chip-to-Chip Communication at the Extremes of Computing
Loh, M. (2013) · ProQuest LLC eBooks · doi:10.7907/fq18-2x96
Challenges in System and Circuit Design for High Density Retinal Prosthesis
Sivaprakasam, M., Liu, W., Wang, G., Zhou, M., Weiland, J. D., & Humayun, M. S. (2006) · IEEE/NIH Life Science Systems and Applications Workshop · doi:10.1109/lssa.2006.250386
Self-citationSimulated phosphene model for visual prosthesis
Zhao, Y., Yang, K., Pang, B., Wang, Y., & Ren, Q. (2012) · International Conference on Biomedical Engineering and Informatics (BMEI) · doi:10.1109/bmei.2012.6512915
Use of the Extended Kalman Filter for biological models accuracy
Omekanda, S., Omekanda, J.-L., Abdel-Aty-Zohdy, H. S., & Zohdy, M. A. (2013) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas.2013.6674722
Image processing method for artificial sight systems based on contrast information
Özden, M., Karadoruk, N., & Karagoz, I. (2009) · National Biomedical Engineering Meeting · doi:10.1109/biyomut.2009.5130320
Image processing system dedicated to a visual intra‐cortical stimulator
Ghannoum, A., Ghafar‐Zadeh, E., & Sawan, M. (2014) · IET Image Processing · doi:10.1049/iet-ipr.2013.0838
Simulation on heat transfer of the Light Switchable Microelectrode Array for retinal prosthesis
Wang, T., Zhang, X., & Li, Z. (2013) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems.2013.6559733
Dégénérescence des photorécepteurs: stratégies thérapeutiques et nouvelles perspectives
Fradot, M., Yang, Y., Rosolen, S. G., Sahel, J., & Picaud, S. A. (2011) · Bulletin de l Académie vétérinaire de France · doi:10.4267/2042/48070
Text image processing for visual prostheses
Wang, S., Li, Y., & Barnes, N. M. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346589
Recognition of Chinese character formed by irregular simulated phosphene arrays
Zhao, Y., & Ren, Q. (2012) · International Conference on Signal Processing · doi:10.1109/icosp.2012.6492028
Image perception of vision impaired by epi-retinal electrode stimulation
Cui, H., Xu, S., Hu, Y. S., Feng, L., & Xie, X. (2014) · International Conference on Image Processing Theory, Tools and Applications (IPTA) · doi:10.1109/ipta.2014.7002003
A multi-microchip retinal stimulator for in vitro / in vivo experiments
Ohta, J., Tokuda, T., Kagawa, K., Uehara, A., Terasawa, Y., Nakauchi, K., Fujikado, T., & Tano, Y. (2007) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2007.378435
TOWARDS PHOTOVOLTAIC POWERED ARTIFICIAL RETINA
Silvestre, S., Bermejo, S., Murillo, D. G., Ortega, P., & Castañer, L. (2011) · Journal of Accessibility and Design for All · doi:10.17411/jacces.v1i1.77
Fabrication and performance of the light switchable microelectrode array for retinal prosthesis
Zhang, X., Wang, T., Chiou, P.-Y. E., & Li, Z. (2013) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2013.6627288
Implantes eletrônicos para restabelecimento da visão em cegos
Rodrigues, E. B., de Ávila, M. P., Hesse, L., Schanze, T., & Kroll, P. B. (2004) · Arquivos Brasileiros de Oftalmologia · doi:10.1590/s0004-27492004000200032 · Cited by 1
Retinal prosthesis : Testing prototypes on a dystrophic rat retina
Salzmann, J., Guyomard, J. L., Linderholm, O. P., Kolomiets, B. P., Kasi, H., Pâques, M., Simonutti, M., Dubus, É., Rosolen, S. G., Sahel, J., et al. (2007) · European Conference on Circuit Theory and Design · doi:10.1109/ecctd.2007.4529596
Entorno hardware/software para experimentación con neuroprótesis visuales
García, R., & Francisco, S. (2011)
Sui, X., Tan, F., Liang, T., Chen, W., Li, G., & Ren, Q. (2009) · International Conference on Biomedical Engineering and Informatics (BMEI) · doi:10.1109/bmei.2009.5305136
Ryu, S. B., Ye, J. H., Kim, C. H., Goo, Y. S., & Kim, K. H. (2009) · Korean Journal of Physiology and Pharmacology · doi:10.4196/kjpp.2009.13.3.221
Kim, H.-S., Shin, J., & Park, K. S. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-03889-1_154
Implants using Liquid Crystal Polymers
Lee, S. W., Seo, J.-M., Ha, S., Kim, E., Chung, H., & Kim, S. J. (2009)
Two approaches to the optic nerve visual prosthesis.
Delbeke, J., Iyad Obeid, A., Duret, F., & Veraart, C. (2005)
Smart Stimulators for Retinal Prosthesis A Flexible and Extendable Microchip-Based Stimulator
Ohta, J., Tokuda, T., Kagawa, K., Furumiya, T., Uehara, A., Terasawa, Y., Ozawa, M., Fujikado, T., & Tano, Y. (2006)
Artificial Vision byElectrical Stimulation of theRetina
EyeInstitute, D. (2005)
Challenges inSystemandCircuit Design forHighDensity Retinal Prosthesis
Sivaprakasam, M., Liu, W., Wang, G., Zhou, M., & Mark, ○. (2006)
Photochemical control of neuronal activity: methods and clinical application
Tochitsky, I. (2013) · eScholarship (California Digital Library)
A Novel Approach for Quantitative Analysis of 3D Phosphenes
Soto‐Sánchez, C., Olmedo-Payá, A., de Santos‐Sierra, D., Agullo, C., & Fernández, E. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-38637-4_35
Prosthetic Vision, Perceptual Effects
Dagnelie, G., & Stronks, H. C. (2014) · Springer eBooks · doi:10.1007/978-1-4614-7320-6_657-1
Self-citationImprovement of Stimulus Performance by Surface Coating of Stimulus Electrodes for Retinal Prosthesis
Noda, T., Takehara, H., Sasagawa, K., Tokuda, T., & Ohta, J. (2014) · Journal of The Surface Finishing Society of Japan · doi:10.4139/sfj.65.257
Implantable retinal prosthesis devices
Ohta, J., Tokuda, T., & Kagawa, K. (2007) · The Review of Laser Engineering · doi:10.2184/lsj.35.210
Bendali, A., Lorach, H., Djilas, M., Marre, O., Bensoman, R., Rousseau, L., Lissorgues, G., Scorsone, E., Bergonzo, P., Garrido, J. A., et al. (2013) · Biologie Aujourd hui · doi:10.1051/jbio/2013008
The Development of a Retinal Prosthesis: A Significant Biomaterials Challenge
Humayun, M. S., Rowley, A. P., Whalen, J. J., Weiland, J. D., & Tanguay, A. R. (2012) · Elsevier eBooks · doi:10.1016/b978-0-08-087780-8.00081-4
Self-citationChallenges in Moving Toward Product Development
Meadows, P. M. (2009) · Elsevier eBooks · doi:10.1016/b978-0-12-374248-3.00005-7
Usha Nandini, M. (2016) · Texila international journal of medicine · doi:10.21522/tijmd.2013.04.01.art016
Simulation of Electrode-Tissue Interface with Biphasic Pulse Train for Epiretinal Prosthesis
Biswas, S., Das, S., & Mahadevappa, M. (2013)
Therapeutische Anwendung und aktive retinale Implantate bei hereditären Netzhautdegenerationen
Gekeler, F., Stuttgart, K., & Tübingen, E.-K.-U. (2015)
Jigsaw puzzle task implementation under simulated prosthetic vision
Zhao, Y., Zhai, L., Geng, X., & Gu, Y. (2016) · International Conference on Systems and Informatics (ICSAI) · doi:10.1109/icsai.2016.7811126
Jow, U.-M. (2013) · SMARTech Repository (Georgia Institute of Technology)
Visual Prosth 41. Visual Prostheses
Fernández, E., & Hoffmann, K. (2011)
High Resolution Optoelectronic Retinal Prosthesis
Palanker, D. (2007) · Frontiers in Optics · doi:10.1364/fio.2007.ftht3
Scene Representation for Mobility of the Visually Impaired
Tatur, G. (2017) · Springer eBooks · doi:10.1007/978-3-319-54446-5_10 · Cited by 1
Optimizing Electrical Stimulation for Closed‐loop Control of Neural Ensembles
Eldawlatly, S. (2017) · Wiley eBooks · doi:10.1002/9781119159193.ch32
Gekeler, F., Zrenner, E., & Bartz‐Schmidt, K. U. (2015) · Der Ophthalmologe · doi:10.15496/publikation-10272
Neural networks-on-chip for hybrid bio-electronic systems
Coapes, G. (2016)
Kanda, H., & Fujikado, T. (2017) · Journal of the Japan Society for Precision Engineering · doi:10.2493/jjspe.83.988
Xie, H., Wang, Y., & Chan, L. L.-H. (2018) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-4505-9_20
Current Advances in the Design of Retinal and Cortical Visual Prostheses
Bareket, L., Barriga‐Rivera, A., Rosenfeld, J. V., Lovell, N. H., & Suaning, G. J. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-812539-7.00005-2
Mini-Review of Technologies for Mobility of the Visually Impaired
Pissaloux, E. E. (2018) · Biomedical Journal of Scientific & Technical Research · doi:10.26717/bjstr.2018.09.001732 · Cited by 1
Photovoltaic stimulation efficiently evokes network-mediated activity of retinal ganglion cellsPreprint
Chenais, N. A. L., Leccardi, M. J. I. A., & Ghezzi, D. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/652404
Metadata
- Authors
- Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., & de Juan, E.
- Affiliations
- University of Southern California (US)
- Second Sight Medical Products (US)
- Johns Hopkins University (US)
- Corresponding author
- Humayun, Mark S.
- Venue
- Vision Research
- Publisher
- Elsevier BV
- Published
- 2003-11
- Volume
- 43
- Issue
- 24
- Pages
- 2573-2581
- ISSN
- 0042-6989 (ISSN-L)
- OpenAlex
- W2131773286
- Cited by
- 856
- References
- 21
- Citations by year
- 2026: 11 · 2025: 14 · 2024: 15 · 2023: 13 · 2022: 26 · 2021: 23 · 2020: 20 · 2019: 26 · 2018: 22 · 2017: 32 · 2016: 36 · 2015: 31 · 2014: 46 · 2013: 62 · 2012: 52
- FWCI
- 15.48
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Vision Research (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- National Eye Institute (R01EY012843)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
- Keywords
- retinal prosthesis, visual perception, platinum electrode, light perception, motion detection, shape recognition, chronic implantation
- MeSH terms
- Aged, Blindness, Electrodes, Implanted, Humans, Male, Photoreceptor Cells, Retina, Retinitis Pigmentosa, Visual Perception, Treatment Outcome, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review