The DOI matches its Crossref record; 20 of the 21 references it cites were found in a registry or an index.
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Open accessAbstract
A retinal prosthesis was permanently implanted in the eye of a completely blind test subject. This report details the results from the first 10 weeks of testing with the implant subject. The implanted device included an extraocular case to hold electronics, an intraocular electrode array (platinum disks, 4 x 4 arrangement) designed to interface with the retina, and a cable to connect the electronics case to the electrode array. The subject was able to see perceptions of light (spots) on all 16 electrodes of the array. In addition, the subject was able to use a camera to detect the presence or absence of ambient light, to detect motion, and to recognize simple shapes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Due to axonal activation, phosphenes often appear with an elongated shape distorting the image perceived by the patient [46].”
From Advances in visual prostheses: engineering and biological challenges (2022) · cites this paper as [46]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prevalence of age-related maculopathy
Klein, R., Klein, B. E. K., & Linton, K. L. P. (1992) · Ophthalmology · doi:10.1016/s0161-6420(92)31871-8 · Cited by 1,845
The Five-year Incidence and Progression of Age-related Maculopathy
Klein, R., Klein, R., Jensen, S. C., & Meuer, S. M. (1997) · Ophthalmology · doi:10.1016/s0161-6420(97)30368-6 · Cited by 1,154
Will Retinal Implants Restore Vision?
Zrenner, E. (2002) · Science · doi:10.1126/science.1067996 · Cited by 736
Preservation of the Inner Retina in Retinitis Pigmentosa
Santos, A. (1997) · Archives of Ophthalmology · doi:10.1001/archopht.1997.01100150513011 · Cited by 651
Visual Perception Elicited by Electrical Stimulation of Retina in Blind Humans
Humayun, M. S. (1996) · Archives of Ophthalmology · doi:10.1001/archopht.1996.01100130038006 · Cited by 602
Self-citationPattern electrical stimulation of the human retina
Humayun, M. S., de Juan, E., Weiland, J. D., Dagnelie, G., Katona, S., Greenberg, R. J., & Suzuki, S. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00052-8 · Cited by 598
Self-citationMorphometric analysis of the extramacular retina from postmortem eyes with retinitis pigmentosa.
Humayun, M. S., Prince, M. R., de Juan, E., Barrón, Y., Moskowitz, M., Klock, I. B., & Milam, A. H. (1999) · PubMed · Cited by 366
Self-citationNeural prostheses : fundamental studies
Agnew, W. F., & McCreery, D. B. (1990) · Medical Entomology and Zoology · Cited by 316
Learning Retina Implants with Epiretinal Contacts
Eckmiller, R. (2009) · Ophthalmic Research · doi:10.1159/000268026 · Cited by 257
Subretinal electrical stimulation of the rabbit retina
Chow, A. Y., & Chow, V. Y. (1997) · Neuroscience Letters · doi:10.1016/s0304-3940(97)00185-7 · Cited by 242
Cited by
Sorted by citations
Items 801–855 of 855
Retinal prosthesis and “bionic eyes” for vision restoration in the blind: From dawn to dusk
Sabel, B. A., & Richard, G. W. (2020) · Clinical Neurophysiology · doi:10.1016/j.clinph.2020.02.018
Hornig, R., & Velikay‐Parel, M. (2013) · Elsevier eBooks · doi:10.1533/9780857096289.3.469
Dagnelie, G. (2007) · Elsevier eBooks · doi:10.1016/b978-012370615-7/50073-1
Self-citationHumayun, M. S., Brant, R., & Weiland, J. D. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4557-0737-9.00126-0
Self-citationSpatial navigation with a simulated prosthetic vision in a virtual environment
Vergnieux, V., Macé, M. J. ‐., & Jouffrais, C. (2012) · HAL
A Treatise on Electrode Carrier Dislocation in Visual Prosthetic Devices
Villarreal, D. L., Zevallos, E. J. C., Perea, A. M., & Krautschneider, W. H. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9629768
The Effect of Electrical Stimulation on the Response of Mouse Retinal Ganglion Cells
Li, W., Xu, Z., Wang, H., & Wu, T. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630580
Nayagam, D. A. X., Durmo, I., McGowan, C. C., Williams, R. A., & Shepherd, R. K. (2021) · doi:10.3791/52348-v
Faculty Opinions recommendation of Photochemical restoration of visual responses in blind mice.
Lawrence, D. S., & O’Banion, C. P. (2012) · Faculty Opinions – Post-Publication Peer Review of the Biomedical Literature · doi:10.3410/f.717952695.793458351
Stem Cells in the Developing and Adult Nervous System
Osakada, F., & Takahashi, M. (2016) · Springer eBooks · doi:10.1007/978-3-319-27583-3_4
Stem Cells in the Developing and Adult Nervous System
Osakada, F., & Takahashi, M. (2013) · Springer eBooks · doi:10.1007/978-94-007-5690-8_5
Prosthetic Vision, Perceptual Effects
Dagnelie, G., & Stronks, H. C. (2015) · Springer eBooks · doi:10.1007/978-1-4614-6675-8_657
Self-citation刘, 易., 牛, 帅., 周, 业., 周, 阳., 任, 秋., & 牛, 金. (2007) · Science in China Series F-Information Sciences (in Chinese) · doi:10.1360/zf2007-37-10-1354
Seelman, K. D., Brabyn, J. A., Ortmann, A. J., & Palmer, C. V. (2006) · Wiley Encyclopedia of Biomedical Engineering · doi:10.1002/9780471740360.ebs1070
B1.4 - A Fully Implantable Epiretinal Vision Prosthesis for Retinitis Pigmentosa Patients
Schanze, T., & Thomas, U. (2009) · SENSOR International Conference on Sensors and Measurement Technology (SENSOR) · doi:10.5162/sensor09/v1/b1.4
Djilas, M., & Picaud, S. A. (2014) · Advances in bioinformatics and biomedical engineering book series · doi:10.4018/978-1-4666-6094-6.ch002
Thoreson, W. B., & Margalit, E. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.05181-3
Visual Prosthesis, Optic Nerve Approaches
Ren, Q. (2022) · Encyclopedia of Computational Neuroscience · doi:10.1007/978-1-0716-1006-0_664
Prosthetic Vision, Perceptual Effects
Dagnelie, G., & Stronks, H. C. (2022) · Springer eBooks · doi:10.1007/978-1-0716-1006-0_657
Self-citationLuo, J. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.12.27.522047
Visual Prostheses: Neuroengineering Handbook
Guo, T., Shivdasani, M. N., Tsai, D., Ayton, L. N., Rathbun, D. L., & Lovell, N. H. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_31
Analysis of the results of transplantation of the retinal pigment epithelium in the experiment
Lagarkova, M. A., Катаргина, Л. А., Izmailova, N. S., Ilyukhin, P. A., Kharitonov, A. E., Utkina, O. A., & Neroeva, N. V. (2023) · Genes and Cells · doi:10.23868/gc346688
Advancements in Retinal Prosthesis Systems: A Review of the Literature
Kim, M. H., Lee, J., Kim, Y., Choi, J. H., Yu, J., & Chung, Y.-R. (2023) · Journal of Retina · doi:10.21561/jor.2023.8.2.73
Firsov, M. L. (2024) · Neuroscience and Behavioral Physiology · doi:10.1007/s11055-024-01597-8
Firsov, M. L. (2023) · Сенсорные системы · doi:10.31857/s0235009223030046
A Brief History of Macular Surgery
D’Amico, D. J. (2024) · Springer eBooks · doi:10.1007/978-3-031-63508-3_1
Spatially Localized Visual Perception Estimation by Means of Prosthetic Vision Simulation
Villarreal, D. L., & Krautschneider, W. H. (2024) · Journal of Imaging · doi:10.3390/jimaging10110294
Nakanishi, Y., Hattori, T., Sriitsaranusorn, W., Tso, K.-C., Shodo, K., Takehara, H., Sunaga, Y., Haruta, M., Tashiro, H., Terasawa, Y., et al. (2025) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ad99e0
Irregular Artificial Vision Optimization Strategies Based on Transformer Saliency Detection
Wang, J., Zhao, R., He, H., Zhou, X., & Han, Y. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3524642
Short Pulse Epiretinal Stimulation Allows Focal Activation of Retinal Ganglion Cells
Koppenwallner, L. X., Zeck, G. M., & Werginz, P. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3529940
Mokwa, W. (2008) · Elsevier eBooks · doi:10.1016/b978-0-323-95478-5.00051-0 · Cited by 1
Rezende, F., Ramirez, K. A., Drew-Bear, L. E., Vega-Garces, M. I., Belandria, H. B., Grané, N. V., & Arévalo, J. F. (2025) · Springer eBooks · doi:10.1007/978-3-031-29358-0_23-1
Experiences of Retinal Prosthesis Wearers with Auditory Impairment
Kartha, A., & Dagnelie, G. (2025) · doi:10.1093/oso/9780192887221.003.0034
Self-citationAn update on human visual prosthesis: The Claes H. Dohlman lecture 2025
Arévalo, J. F., & Ramirez, K. A. (2025) · Taiwan Journal of Ophthalmology · doi:10.4103/tjo.tjo-d-25-00041
Adaptive vision transformer for enhanced perception in visual prostheses
Tomas-Barba, J., Pérez-Yus, A., Martínez-Cantín, R., Guerrero, J. J., & Bermúdez-Cameo, J. (2025) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc58623.2025.11253400
Stamcellsterapi : En teknik som räddar synen?!
Falinska-Krol, J. (2010) · KTH Publication Database DiVA (KTH Royal Institute of Technology)
A Kalman filter model for signal estimation in the auditory system
Hauger, M. M. (2005) · UpSpace Institutional Repository (University of Pretoria)
Ohta, J., Tokuda, T., Hiyama, K., Sawamura, S., Sasagawa, K., Nishida, K., Kitaguchi, Y., Kamei, M., Fujikado, T., & Tano, Y. (2024) · IISS online library · doi:10.60928/7dyp-tk8x
Motion perception with visual prostheses
Renshaw, K. T., & Pezaris, J. S. (2026) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ae46fd · Cited by 1
Mapping the intellectual landscape and emerging trends of retinitis pigmentosa research
Xiao, L., Tang, L.-X., Ai, M., Yang, Y., Deng, Y., Lu, J., Zhou, Y.-S., Xiong, J., & Peng, Q. (2026) · Frontiers in Medicine · doi:10.3389/fmed.2026.1740088
Development and Characterization of a new generation of retinal implants
González‐Losada, P. (2018) · theses.fr (ABES) · doi:10.70675/47828c1azf184z44c5za2abze01b34668eaa
From adaptation mechanisms with visual impairment to new technologies in vision restoration
Kime, S. (2016) · theses.fr (ABES) · doi:10.70675/a5e5f10fzf01cz40d1za5f2z5067b3e0d7b1
Neurochip implants for sight recovery bridging neuroscience and engineering
Khanna, V., & Khanna, P. (2026) · i-manager’s Journal on Future Engineering and Technology · doi:10.26634/jfet.21.2.843
Vision restoration: From prostheses to genetic-based brain–machine interfaces
Alcala, I., DESAILLY, E., Arcizet, F., Marazova, K., Gauvain, G., & Picaud, S. A. (2026) · Handbook of clinical neurology · doi:10.1016/b978-0-443-22212-2.00017-3
Trends in neuroprosthetic technologies to restore sensations
Park, B., Butterworth, W., Lee, N., & Kim, S. (2026) · Biomedical Engineering Letters · doi:10.1007/s13534-026-00603-x
Biomaterials in Retinal Surgery: Engineering the Future
Dindar, I. A., Shoichet, M. S., Labriola, J. M., Forman, A., & Devenyi, R. G. (2026) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2026.08.039
Li, X., Khalil, I., Rahman, F., & Khan, M. N. (2026) · Biomimetics · doi:10.3390/biomimetics11090649 · Cited by 6
Rezende, F., Ramirez, K. A., Drew-Bear, L. E., Vega-Garces, M. I., Belandria, H. B., Grané, N. V., & Arevalo, J. F. (2026) · Springer eBooks · doi:10.1007/978-3-032-23052-2_23
Barnes, N. M., Petoe, M. A., Kolic, M., Baglin, E. K., Titchener, S. A., Habili, N., Kentler, W. G., Abbott, C. J., Allen, P. J., & Walker, J. G. (2026) · Translational Vision Science & Technology · doi:10.1167/tvst.15.10.21
Metadata
- Authors
- Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., & de Juan, E.
- Affiliations
- University of Southern California (US)
- Second Sight Medical Products (US)
- Johns Hopkins University (US)
- Corresponding author
- Humayun, Mark S.
- Venue
- Vision Research
- Publisher
- Elsevier BV
- Published
- 2003-11
- Volume
- 43
- Issue
- 24
- Pages
- 2573-2581
- ISSN
- 0042-6989 (ISSN-L)
- OpenAlex
- W2131773286
- Cited by
- 856
- References
- 21
- Citations by year
- 2026: 11 · 2025: 14 · 2024: 15 · 2023: 13 · 2022: 26 · 2021: 23 · 2020: 20 · 2019: 26 · 2018: 22 · 2017: 32 · 2016: 36 · 2015: 31 · 2014: 46 · 2013: 62 · 2012: 52
- FWCI
- 15.48
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Vision Research (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- National Eye Institute (R01EY012843)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
- Keywords
- retinal prosthesis, visual perception, platinum electrode, light perception, motion detection, shape recognition, chronic implantation
- MeSH terms
- Aged, Blindness, Electrodes, Implanted, Humans, Male, Photoreceptor Cells, Retina, Retinitis Pigmentosa, Visual Perception, Treatment Outcome, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review