Insulin pump treatment compared with multiple daily injections for treatment of type 2 diabetes (OpT2mise): a randomised open-label controlled trial
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Background Many patients with advanced type 2 diabetes do not meet their glycated haemoglobin targets and randomised controlled studies comparing the efficacy of pump treatment and multiple daily injections for lowering glucose in insulin-treated patients have yielded inconclusive results. We aimed to resolve this uncertainty with a randomised controlled trial (OpT2mise).Methods We did this multicentre, controlled trial at 36 hospitals, tertiary care centres, and referal centres in Canada, Europe, Israel, South Africa, and the USA. Patients with type 2 diabetes who had poor glycaemic control despite multiple daily injections with insulin analogues were enrolled into a 2-month dose-optimisation run-in period. After the run-in period, patients with glycated haemoglobin of 8·0-12·0% (64-108 mmol/mol) were randomly assigned (1:1) by a computer-generated randomisation sequence (block size 2 with probability 0·75 and size 4 with probability 0·25) to pump treatment or to continue with multiple daily injections. Neither patients nor investigators were masked to treatment allocation. The primary endpoint was change in mean glycated haemoglobin between baseline and end of the randomised phase for the intention-to-treat population. This study is registered with ClinicalTrials.gov, number NCT01182493.Findings 495 of 590 screened patients entered the run-in phase and 331 were randomised (168 to pump treatment, 163 to multiple daily injections). Mean glycated haemoglobin at baseline was 9% (75 mmol/mol) in both groups. At 6 months, mean glycated haemoglobin had decreased by 1·1% (SD 1·2; 12 mmol/mol, SD 13) in the pump treatment group and 0·4% (SD 1·1; 4 mmol/mol, SD 12) in the multiple daily injection group, resulting in a between-group treatment difference of -0·7% (95% CI -0·9 to -0·4; -8 mmol/mol, 95% CI -10 to -4, p<0·0001). At the end of the study, the mean total daily insulin dose was 97 units (SD 56) with pump treatment versus 122 units (SD 68) for multiple daily injections (p<0·0001), with no significant difference in bodyweight change between the two groups (1·5 kg [SD 3·5] vs 1·1 kg [3·6], p=0·322). Two diabetes-related serious adverse events (hyperglycaemia or ketosis without acidosis) resulting in hospital admission occurred in the pump treatment group compared with one in the multiple daily injection group. No ketoacidosis occurred in either group and one episode of severe hypoglycaemia occurred in the multiple daily injection group.Interpretation In patients with poorly controlled type 2 diabetes despite using multiple daily injections of insulin, pump treatment can be considered as a safe and valuable treatment option.Funding Medtronic.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Ultra-rapid acting insulins can reduce postprandial glycemic peak, but this effect on long-term complications is unknown.1085,1086”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1085]
In the citing paper
“Similar to data on insulin pump use in people with type 1 diabetes, reductions in A1C levels have been reported in some studies (243,246).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [246]
In the citing paper
“The OpT2mise RCT, which included adults with EOT2D amongst older participants aged 30 to 75 years (mean age± standard deviation=55.5±9.7 years), demonstrated that insulin pump therapy led to marked reductions in mean total daily insulin dose and improvements in HbA1c, compared to multiple- dose injection therapy [98].”
From Management of Early-Onset Type 2 Diabetes in Adults: Current Evidence and Future Directions (2025) · cites this paper as [98]
Citations
Cites
The Montreal Cognitive Assessment, MoCA: a brief screening tool for mild cognitive impairment
Nasreddine, Z. S., Phillips, N. A., Bédirian, V., Charbonneau, S., Whitehead, V., Collin, I., Cummings, J. L., & Chertkow, H. (2005) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2005.53221.x · Cited by 25,553
Multiple Imputation for Nonresponse in Surveys
Rubin, D. B. (1987) · Wiley Series in Probability and Statistics · doi:10.1002/9780470316696 · Cited by 20,701
Nathan, D. M., Buse, J. B., Davidson, M. B., Ferrannini, E., Holman, R. R., Sherwin, R., & Zinman, B. (2009) · Diabetes Care · doi:10.2337/dc08-9025 · Cited by 3,834
A Multiple Testing Procedure for Clinical Trials
O'Brien, P. C., & Fleming, T. R. (1979) · Biometrics · doi:10.2307/2530245 · Cited by 3,311
Multiple Imputation for Nonresponse in Surveys.
Lynn, P., & Rubin, D. B. (1988) · The Statistician · doi:10.2307/2348774 · Cited by 2,329
Riddle (2003) · doi:10.2337/diacare.26.11.3080 · Cited by 1,479
Nathan, D. M., Buse, J. B., Davidson, M. B., Ferrannini, E., Holman, R. R., Sherwin, R., & Zinman, B. (2009) · Diabetologia · doi:10.1007/s00125-008-1157-y · Cited by 712
Weissberg-Benchell, J., Antisdel-Lomaglio, J., & Seshadri, R. (2003) · Diabetes Care · doi:10.2337/diacare.26.4.1079 · Cited by 551
Ferrannini, E., Gastaldelli, A., Miyazaki, Y., Matsuda, M., Mari, A., & DeFronzo, R. A. (2005) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2004-1133 · Cited by 540
Kooy, A., de Jager, J., Lehert, P., Bets, D., Wulffelé, M. G., Donker, A. J. M., & Stehouwer, C. D. A. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.20 · Cited by 440
Cited by
Items 201–233 of 233
Insulin Patch Pumps in Type 2 Diabetes
Altendorf, C. (2015) · UND Scholarly Commons (University of North Dakota)
Conget, I., Aronson, R., Lee, S., Cohen, O., & Reznik, Y. (2014) · Diabetes Care · doi:10.2337/dc14-1632 · Cited by 1
Self-citationMarotta, K. A., Etienne, D., & Hamilton, S. S. (2021) · Evidence-Based Practice · doi:10.1097/ebp.0000000000001284
Insulin pump therapy in type 2 diabetes: a consensus proposal
Grassi, G. M. (2018) · The Journal of AMD · doi:10.36171/jamd18.21.2.07
Insulins and Insulin Delivery Devices
Choudhary, P., & Jacob, P. (2022) · doi:10.1093/med/9780198870197.003.0252 · Cited by 1
Insulin Delivery Hardware: Pumps and Pens
Lal, R., & Leelarathna, L. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.2502 · Cited by 1
Botero, J. F., Vásquez, L. M., Blanco, V. M., Cuesta, D., Rincón, A. R., Bedoya, J., & Palacio, A. (2021) · Endocrinología Diabetes y Nutrición (English ed ) · doi:10.1016/j.endien.2021.12.002 · Cited by 3
Pickup, J. C. (2018) · Endocrinology · doi:10.1007/978-3-319-45015-5_22
Manuscripts Reviewed for the 2014 Yearbook
(2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.1515
Larasati, A. P., Prajitno, J. H., & Purwanto, B. (2023) · Current Internal Medicine Research and Practice Surabaya Journal · doi:10.20473/cimrj.v4i2.49154 · Cited by 1
Moon, S. J., Hong, J. H., Kim, S. S., Kim, K., Lim, S. K., Jin, H. Y., Hwang, Y., Lee, S., Lee, K., Kang, J. G., et al. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4608008
Self-citationMoraes, B. T. M., da Cunha, I. C. O., Okita, M. T., Lisi, D. C., Alvarenga, J. V. S., & Gyotoku, L. C. (2023) · Revista Interdisciplinar de Saúde e Educação · doi:10.56344/2675-4827.v4n3a2023.7
New Technologies for Insulin Administration
Forde, H. E., & Choudhary, P. (2024) · Wiley eBooks · doi:10.1002/9781119697473.ch33
Mohammadian-Hafshejani, A., Kheiri, S., & Karimi, Z. (2024) · Medical Journal of Tabriz University of Medical Sciences and Health Services · doi:10.34172/mj.2024.009
Perfilando la tecnología en diabetes
Gómez, N. B., Jiménez-Salazar, S., Delgado, M. R., Botero, J. F., & Rincón, A. R. (2024) · Revista Colombiana de Endocrinología Diabetes & Metabolismo · doi:10.53853/encr.11.1.852
Other Considerations in Pump Therapy Management
(2024) · American Diabetes Association eBooks · doi:10.2337/9781580408363.ch07
Cristino, G. S. G., Neto, I. D. P., Dias, J. M., Coelho, J. V. R., Marzola, M. V., & Lopes, C. D. (2024) · Revista Contemporânea · doi:10.56083/rcv4n12-053
Diabetes Technology in the Geriatric Population
Pisano, M., Mazzola, N., & Nguyen, N. M. (2024) · Contemporary Endocrinology · doi:10.1007/978-3-031-75352-7_7
Cengiz, E. (2019) · doi:10.2337/9781580406932.part1_ch03
Schmitt, J., Teixeira, M., & Bargain, D. (2025) · Recherche en soins infirmiers · doi:10.3917/rsi.158.0058
Review on the Treatment Progress of Type 2 Diabetes Mellitus
Liu, M., Zhou, H., Huang, S., Zhang, W., Xu, J., Xin, X., & Yu, D. (2025) · Journal of Biosciences and Medicines · doi:10.4236/jbm.2025.137009
Sun, R.-M., Dai, D.-X., Xu, F., Ling, Y., & Xie, Z. (2025) · World Journal of Diabetes · doi:10.4239/wjd.v16.i7.106470
Dou, Y., Peng, C., Zhou, Y., & Liu, Y. (2025) · Medicine · doi:10.1097/md.0000000000045761
Insulin pumps and artificial pancreas
Markakis, K. P., & Vazeou, A. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-13825-6.00296-x
Chua, A. Y., & Villa, M. L. (2018) · Philippine Journal of Internal Medicine · doi:10.65564/pjim.e77e273ac5
Mise au point sur l’utilisation de l’insulinothérapie automatisée pour traiter le diabète de type 2
Reznik, Y. (2026) · Médecine des Maladies Métaboliques · doi:10.1016/j.mmm.2026.01.011
Self-citationChoi, S.-B. (2026) · AACE Endocrinology and Diabetes · doi:10.1016/j.aed.2026.03.010
Moderne Technologien: Nutzen auch für Menschen mit Typ-2-Diabetes?
Thomas, A., & Woitek, C. (2026) · Info Diabetologie · doi:10.1007/s15034-026-5248-y
Saiprasad, S., & Swamy, N. (2026) · JCEM Case Reports · doi:10.1210/jcemcr/luag184
Digital Health Technologies and Hypoglycaemia
Villard, O., & Renard, É. (2026) · Springer eBooks · doi:10.1007/978-3-032-24854-1_24
Prise en charge thérapeutique du diabète de type 2
Rigalleau, V., Cherifi, B., Blanco, L., Larroumet, A., Foussard, N., & Mohammedi, K. (2026) · EMC - Traité de médecine AKOS · doi:10.1016/s1634-6939(26)50825-1
Clinical human-factors value and international experience of mechanical patch insulin pumps
Yang, R., Yang, Z., Wang, X., & Ya, Z. (2026) · Intelligent Pharmacy · doi:10.1016/j.ipha.2026.10.004
Metadata
- Authors
- Reznik, Y., Cohen, O., Aronson, R., Conget, I., Runzis, S., Castaneda, J., & Lee, S. W.
- Affiliations
- Centre Hospitalier Universitaire de Caen Normandie (FR)
- Sheba Medical Center (IL)
- LMC Diabetes & Endocrinology (Canada) (CA)
- Hospital Clínic de Barcelona (ES)
- Medtronic (Switzerland) (CH)
- Corresponding author
- Reznik, Yves
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2014-10
- Volume
- 384
- Issue
- 9950
- Pages
- 1265-1272
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2131145650
- Semantic Scholar
- 9efe76fd3c2ea26e63dc2d5aee717a21a194554f
- Cited by
- 233
- References
- 25
- Citations by year
- 2026: 8 · 2025: 15 · 2024: 18 · 2023: 22 · 2022: 9 · 2021: 19 · 2020: 18 · 2019: 17 · 2018: 34 · 2017: 23 · 2016: 19 · 2015: 21 · 2014: 9
- FWCI
- 19.29
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- type 2 diabetes, insulin pump therapy, multiple daily insulin injections, HbA1c, glycemic control, insulin analogues, total daily insulin dose, insulin-treated patients, HbA1c reduction, hypoglycemia, body weight
- MeSH terms
- Adult, Aged, Diabetes Mellitus, Type 2, Drug Administration Schedule, Female, Glycated Hemoglobin, Humans, Hypoglycemic Agents, Injections, Subcutaneous, Insulin, Insulin Infusion Systems, Male, Middle Aged
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.