Insulin pump treatment compared with multiple daily injections for treatment of type 2 diabetes (OpT2mise): a randomised open-label controlled trial
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Background Many patients with advanced type 2 diabetes do not meet their glycated haemoglobin targets and randomised controlled studies comparing the efficacy of pump treatment and multiple daily injections for lowering glucose in insulin-treated patients have yielded inconclusive results. We aimed to resolve this uncertainty with a randomised controlled trial (OpT2mise).Methods We did this multicentre, controlled trial at 36 hospitals, tertiary care centres, and referal centres in Canada, Europe, Israel, South Africa, and the USA. Patients with type 2 diabetes who had poor glycaemic control despite multiple daily injections with insulin analogues were enrolled into a 2-month dose-optimisation run-in period. After the run-in period, patients with glycated haemoglobin of 8·0-12·0% (64-108 mmol/mol) were randomly assigned (1:1) by a computer-generated randomisation sequence (block size 2 with probability 0·75 and size 4 with probability 0·25) to pump treatment or to continue with multiple daily injections. Neither patients nor investigators were masked to treatment allocation. The primary endpoint was change in mean glycated haemoglobin between baseline and end of the randomised phase for the intention-to-treat population. This study is registered with ClinicalTrials.gov, number NCT01182493.Findings 495 of 590 screened patients entered the run-in phase and 331 were randomised (168 to pump treatment, 163 to multiple daily injections). Mean glycated haemoglobin at baseline was 9% (75 mmol/mol) in both groups. At 6 months, mean glycated haemoglobin had decreased by 1·1% (SD 1·2; 12 mmol/mol, SD 13) in the pump treatment group and 0·4% (SD 1·1; 4 mmol/mol, SD 12) in the multiple daily injection group, resulting in a between-group treatment difference of -0·7% (95% CI -0·9 to -0·4; -8 mmol/mol, 95% CI -10 to -4, p<0·0001). At the end of the study, the mean total daily insulin dose was 97 units (SD 56) with pump treatment versus 122 units (SD 68) for multiple daily injections (p<0·0001), with no significant difference in bodyweight change between the two groups (1·5 kg [SD 3·5] vs 1·1 kg [3·6], p=0·322). Two diabetes-related serious adverse events (hyperglycaemia or ketosis without acidosis) resulting in hospital admission occurred in the pump treatment group compared with one in the multiple daily injection group. No ketoacidosis occurred in either group and one episode of severe hypoglycaemia occurred in the multiple daily injection group.Interpretation In patients with poorly controlled type 2 diabetes despite using multiple daily injections of insulin, pump treatment can be considered as a safe and valuable treatment option.Funding Medtronic.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Ultra-rapid acting insulins can reduce postprandial glycemic peak, but this effect on long-term complications is unknown.1085,1086”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1085]
In the citing paper
“Similar to data on insulin pump use in people with type 1 diabetes, reductions in A1C levels have been reported in some studies (243,246).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [246]
In the citing paper
“The OpT2mise RCT, which included adults with EOT2D amongst older participants aged 30 to 75 years (mean age± standard deviation=55.5±9.7 years), demonstrated that insulin pump therapy led to marked reductions in mean total daily insulin dose and improvements in HbA1c, compared to multiple- dose injection therapy [98].”
From Management of Early-Onset Type 2 Diabetes in Adults: Current Evidence and Future Directions (2025) · cites this paper as [98]
Citations
Cites
The Montreal Cognitive Assessment, MoCA: a brief screening tool for mild cognitive impairment
Nasreddine, Z. S., Phillips, N. A., Bédirian, V., Charbonneau, S., Whitehead, V., Collin, I., Cummings, J. L., & Chertkow, H. (2005) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2005.53221.x · Cited by 25,553
Multiple Imputation for Nonresponse in Surveys
Rubin, D. B. (1987) · Wiley Series in Probability and Statistics · doi:10.1002/9780470316696 · Cited by 20,701
Nathan, D. M., Buse, J. B., Davidson, M. B., Ferrannini, E., Holman, R. R., Sherwin, R., & Zinman, B. (2009) · Diabetes Care · doi:10.2337/dc08-9025 · Cited by 3,834
A Multiple Testing Procedure for Clinical Trials
O'Brien, P. C., & Fleming, T. R. (1979) · Biometrics · doi:10.2307/2530245 · Cited by 3,311
Multiple Imputation for Nonresponse in Surveys.
Lynn, P., & Rubin, D. B. (1988) · The Statistician · doi:10.2307/2348774 · Cited by 2,329
Riddle (2003) · doi:10.2337/diacare.26.11.3080 · Cited by 1,479
Nathan, D. M., Buse, J. B., Davidson, M. B., Ferrannini, E., Holman, R. R., Sherwin, R., & Zinman, B. (2009) · Diabetologia · doi:10.1007/s00125-008-1157-y · Cited by 712
Weissberg-Benchell, J., Antisdel-Lomaglio, J., & Seshadri, R. (2003) · Diabetes Care · doi:10.2337/diacare.26.4.1079 · Cited by 551
Ferrannini, E., Gastaldelli, A., Miyazaki, Y., Matsuda, M., Mari, A., & DeFronzo, R. A. (2005) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2004-1133 · Cited by 540
Kooy, A., de Jager, J., Lehert, P., Bets, D., Wulffelé, M. G., Donker, A. J. M., & Stehouwer, C. D. A. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.20 · Cited by 440
Cited by
Chatterjee, S., Khunti, K., & Davies, M. J. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30058-2 · Cited by 2,577
Beck, R. W., Riddlesworth, T. D., Ruedy, K., Ahmann, A., Haller, S., Kruger, D., McGill, J. B., Polonsky, W., Price, D., Aronoff, S., et al. (2017) · Annals of Internal Medicine · doi:10.7326/m16-2855 · Cited by 635
“054 Relative reduction in HbA1c level ≥10%, n (%) 44 (57) 26 (35) 25% (3% to 46%); 0.”
BackgroundSelf-citationHandelsman, Y., Bloomgarden, Z. T., Grunberger, G., Umpierrez, G., Zimmerman, R. S., Bailey, T. S., Blonde, L., Bray, G. A., Cohen, A. J., Dagogo-Jack, S., et al. (2015) · Endocrine Practice · doi:10.4158/ep15672.gl · Cited by 629
Handelsman, Y., Bloomgarden, Z. T., Grunberger, G., Umpierrez, G., Zimmerman, R. S., Bailey, T. S., Blonde, L., Bray, G. A., Cohen, A. J., Dagogo-Jack, S., et al. (2015) · Endocrine Practice · doi:10.4158/ep15672.glsuppl · Cited by 559
Blonde, L., Umpierrez, G. E., Reddy, S. S., McGill, J. B., Berga, S. L., Bush, M., Chandrasekaran, S., DeFronzo, R. A., Einhorn, D., Galindo, R. J., et al. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.08.002 · Cited by 507
ACOG Practice Bulletin No. 201: Pregestational Diabetes Mellitus
(2018) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000002960 · Cited by 470
7. Diabetes Technology: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s007 · Cited by 358
7. Diabetes Technology: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s007 · Cited by 348
7. Diabetes Technology: Standards of Care in Diabetes — 2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s007 · Cited by 301
Grunberger, G., Sherr, J., Allende, M., Blevins, T., Bode, B., Handelsman, Y., Hellman, R., Lajara, R., Roberts, V. L., Rodbard, D., et al. (2021) · Endocrine Practice · doi:10.1016/j.eprac.2021.04.008 · Cited by 288
7. Diabetes Technology: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s007 · Cited by 281
Peters, A. L., Ahmann, A. J., Battelino, T., Evert, A., Hirsch, I. B., Murad, M. H., Winter, W. E., & Wolpert, H. (2016) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2016-2534 · Cited by 250
2021 Clinical Practice Guidelines for Diabetes Mellitus of the Korean Diabetes Association
Hur, K. Y., Moon, M. K., Park, J. S., Kim, S.-K., Lee, S.-H., Yun, J.-S., Baek, J. H., Noh, J., Lee, B.-W., Oh, T. J., et al. (2021) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2021.0156 · Cited by 226
Self-citation7. Approaches to Glycemic Treatment
American Diabetes Association (2016) · Diabetes Care · doi:10.2337/dc16-s010 · Cited by 225
7. Diabetes Technology: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s007 · Cited by 202
RSSDI-ESI clinical practice recommendations for the management of type 2 diabetes mellitus 2020
Madhu, S., Chawla, R., Makkar, B., Ghosh, S., Saboo, B., & Kalra, S. (2020) · Indian Journal of Endocrinology and Metabolism · doi:10.4103/ijem.ijem_225_20 · Cited by 167
Pozzilli, P., Battelino, T., Danne, T., Hovorka, R., Jarosz‐Chobot, P., & Renard, E. (2016) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.2653 · Cited by 160
“[25] in a recent study in which 331 adult patients with T2DM who had poor glycaemic control despite MDI with insulin analogues were randomized to pump treatment (insulin lispro, aspart or glulisine) or to continue with MDI (insulin glargine or detemir, plus insulin lispro, aspart or glulisine).”
BackgroundBerget, C., Messer, L. H., & Forlenza, G. P. (2019) · Diabetes Spectrum · doi:10.2337/ds18-0091 · Cited by 135
New forms of insulin and insulin therapies for the treatment of type 2 diabetes
Cahn, A., Miccoli, R., Dardano, A., & Prato, S. D. (2015) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(15)00097-2 · Cited by 114
Pickup, J. C., Reznik, Y., & Sutton, A. J. (2017) · Diabetes Care · doi:10.2337/dc16-2201 · Cited by 92
Self-citationTechnology in the management of type 2 diabetes: Present status and future prospects
DALY, A. B., & Hovorka, R. (2021) · Diabetes Obesity and Metabolism · doi:10.1111/dom.14418 · Cited by 109
Partridge, H., Perkins, B. A., Mathieu, S., Nicholls, A., & Adeniji, K. A. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev347 · Cited by 85
Insulin Pumps: Review of Technological Advancement in Diabetes Management
Sora, N. D., Shashpal, F., Bond, E., & Jenkins, A. J. (2019) · The American Journal of the Medical Sciences · doi:10.1016/j.amjms.2019.08.008 · Cited by 80
Moon, J. S., Kang, S., Choi, J. H., Lee, K. A., Moon, J. H., Chon, S., Kim, D. J., Kim, H. J., Seo, J. A., Kim, M. K., et al. (2024) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2024.0249 · Cited by 90
The Growing Role of Technology in the Care of Older Adults With Diabetes
Huang, E. S., Sinclair, A., Conlin, P. R., Cukierman-Yaffe, T., Hirsch, I. B., Huisingh-Scheetz, M., Kahkoska, A. R., Laffel, L., Lee, A. K., Lee, S., et al. (2023) · Diabetes Care · doi:10.2337/dci23-0021 · Cited by 73
Self-citationForlenza, G. P., Carlson, A. L., Galindo, R. J., Kruger, D. F., Levy, C. J., McGill, J. B., Umpierrez, G., & Aleppo, G. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0206 · Cited by 70
“0001).(17) In addition, durable effects of insulin pump therapy in T2D have been reported as well.”
BackgroundRandomized clinical trials with run-in periods: frequency, characteristics and reporting
Laursen, D. R. T., Paludan-Müller, A. S., & Hróbjartsson, A. (2019) · Clinical Epidemiology · doi:10.2147/clep.s188752 · Cited by 66
Aronson, R., Reznik, Y., Conget, I., Castañeda, J. A., Runzis, S., Lee, S. W., Cohen, O., & for the OpT2mise Study Group (2016) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.12642 · Cited by 65
Self-citationFreckmann, G., Buck, S., Waldenmaier, D., Kulzer, B., Schnell, O., Gelchsheimer, U., Ziegler, R., & Heinemann, L. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820928100 · Cited by 74
Tagougui, S., Taleb, N., & Rabasa-Lhoret, R. (2019) · Frontiers in Endocrinology · doi:10.3389/fendo.2018.00818 · Cited by 56
Choudhary, P., & Amiel, S. A. (2018) · Diabetologia · doi:10.1007/s00125-018-4566-6 · Cited by 52
“An RCTof CSII vs MDI in type 2 diabetes (OPT2MISE) did show CSII to be of benefit in those who were unable to improve control despite high doses of insulin, although the incidence of hypoglycaemia was low in both groups [44].”
Ceriello, A., de Valk, H. W., Guerci, B., Haak, T., Owens, D. R., Canobbio, M., Fritzen, K., Stautner, C., & Schnell, O. (2020) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2020.108053 · Cited by 53
Ageing well with diabetes: the role of technology
Maltese, G., McAuley, S. A., Trawley, S. L., & Sinclair, A. J. (2024) · Diabetologia · doi:10.1007/s00125-024-06240-2 · Cited by 63
Dicembrini, I., Mannucci, E., Monami, M., & Pala, L. (2019) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.13845 · Cited by 46
Ly, T. T., Layne, J. E., Huyett, L. M., Nazzaro, D., & O’Connor, J. B. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818798836 · Cited by 44
Lin, Y., Mi, F., Lin, P.-Y., Miao, Y., Huang, T., Chen, K., Chen, C.-T., Chang, Y., & Sung, H. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.12.001 · Cited by 47
Borel, A.-L., Lablanche, S., Waterlot, C., Joffray, E., Barra, C., Arnol, N., Amougay, H., & Benhamou, P.-Y. (2024) · Diabetes Care · doi:10.2337/dc24-0623 · Cited by 43
Vigersky, R. A., Huang, S., Cordero, T. L., Shin, J., Lee, S. W., Chhabra, H., Kaufman, F. R., & Cohen, O. (2018) · Endocrine Practice · doi:10.4158/ep-2017-0234 · Cited by 43
Self-citationDiabetes Technology Use in Adults with Type 1 and Type 2 Diabetes
Kravarusic, J., & Aleppo, G. (2020) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2019.10.006 · Cited by 42
Bravo‐Alfaro, D. A., Muñoz-Correa, M. O. F., Santos-Luna, D., Toro-Vazquez, J. F., Cano-Sarmiento, C., García‐Varela, R., & Garcia, H. S. (2020) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2020.101622 · Cited by 43
RSSDI-ESI Clinical Practice Recommendations for the Management of Type 2 Diabetes Mellitus 2020
Chawla, R., Madhu, S. V., Makkar, B. M., Ghosh, S. K., Saboo, B., Kalra, S., & On behalf of RSSDI-ESI Consensus Group (2020) · International Journal of Diabetes in Developing Countries · doi:10.1007/s13410-020-00819-2 · Cited by 61
Blood Glucose Fluctuations in Type 2 Diabetes Patients Treated with Multiple Daily Injections
Li, F.-F., Fu, L., Zhang, W., Su, X., Wu, J.-D., Sun, J., Ye, L., & Ma, J. (2015) · Journal of Diabetes Research · doi:10.1155/2016/1028945 · Cited by 41
Type 2 Diabetes Medication Review
Sterrett, J., Bragg, S. W., & Weart, C. W. (2016) · The American Journal of the Medical Sciences · doi:10.1016/j.amjms.2016.01.019 · Cited by 43
The role of insulin pump therapy for type 2 diabetes mellitus
Landau, Z., Raz, I., Wainstein, J., Bar‐Dayan, Y., & Cahn, A. (2016) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.2822 · Cited by 38
Conget, I., Castañeda, J., Petrovski, G., Guerci, B., Racault, A.-S., Reznik, Y., Cohen, O., Runzis, S., de Portu, S., Aronson, R., et al. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0159 · Cited by 41
Self-citationReznik, Y., Carvalho, M., Fendri, S., Prevost, G., Chaillous, L., Riveline, J. P., Hanaire, H., Dubois, S., Houéto, P., Pasche, H., et al. (2024) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.15351 · Cited by 34
“10,11 Clinical trials and real-life studies have shown the feasibility, safety and efficacy of pump therapy in people with type 2 diabetes, despite potential barriers such as older age, 12 comorbidities, 10 or cognitive limitations.”
BackgroundSelf-citationMoving toward the ideal insulin for insulin pumps
Cengiz, E., Bode, B., Van Name, M., & Tamborlane, W. V. (2016) · Expert Review of Medical Devices · doi:10.1586/17434440.2016.1109442 · Cited by 38
Davis, G. M., Bailey, R. J., Calhoun, P. M., Price, D. A., & Beck, R. W. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0489 · Cited by 37
Layne, J. E., Parkin, C. G., & Zisser, H. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816653143 · Cited by 30
“A growing body of evidence suggests that continuous subcutaneous insulin infusion (CSII) therapy with tubed insulin pumps improves glycemic control in patients with type 2 diabetes.(1-4) Although recent studies have demonstrated improved glycemic control and treatment satisfaction among type 1 diabetes patients using…”
BackgroundGu, W., Liu, Y., Chen, Y., Deng, W., Ran, X., Chen, L., Zhu, D., Yang, J., Shin, J., Lee, S. W., et al. (2017) · Diabetes & Metabolism · doi:10.1016/j.diabet.2016.12.009 · Cited by 31
Self-citationChlup, R., Runzis, S., Castaneda, J., Lee, S. W., Nguyen, X., & Cohen, O. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0283 · Cited by 30
Self-citationBhargava, A., Bergenstal, R. M., Warren, M., Thrasher, J. R., Dempsey, M. A., Bode, B. W., LaRocque, J., Carlson, A. L., Keiter, A., Ma, H., et al. (2025) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2024.0586 · Cited by 34
Grunberger, G., Sze, D., Ermakova, A., Sieradzan, R., Oliveria, T., & Miller, E. M. (2020) · Clinical Diabetes · doi:10.2337/cd19-0008 · Cited by 28
“The safety and efficacy of insulin pump therapy in patients with type 2 diabetes were demonstrated in the Opt2mise program, in which patients who failed to achieve adequate glycemic control on MDI therapy achieved significant, sustained improvements in glycemic outcomes when switched to pump therapy (11,12).”
MethodJoshi, M., & Choudhary, P. (2015) · Current Diabetes Reports · doi:10.1007/s11892-015-0644-z · Cited by 32
Zhang, E., Shi, Y., Han, X., Zhu, H. J., Song, B., Yang, C., & Cao, Z. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01108-z · Cited by 32
Automated Insulin Delivery Systems as a Treatment for Type 2 Diabetes Mellitus: A Review
Karol, A. B., O’Malley, G., Fallurin, R., & Levy, C. J. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.10.001 · Cited by 31
Jendle, J., & Reznik, Y. (2023) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.15087 · Cited by 26
Self-citationContinuous Subcutaneous Insulin Infusion in Italy: Third National Survey
Bruttomesso, D., Laviola, L., Lepore, G., Bonfanti, R., Bozzetto, L., Orsi, E., Blasi, V. D., Girelli, A., Grassi, G., Iafusco, D., et al. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0242 · Cited by 31
Lajara, R., Fetchick, D. A., Morris, T. L., & NIKKEL, C. C. (2015) · Diabetes Therapy · doi:10.1007/s13300-015-0138-7 · Cited by 24
Lajara, R., Davidson, J. A., NIKKEL, C. C., & Morris, T. L. (2016) · Endocrine Practice · doi:10.4158/ep151182.or · Cited by 25
Taleb, N., Messier, V., Ott-Braschi, S., Ardilouze, J.-L., & Rabasa-Lhoret, R. (2018) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2018.07.035 · Cited by 25
Doucet, J., Gourdy, P., Meyer, L., Benabdelmoumene, N., & Bourdel‐Marchasson, I. (2023) · Clinical Interventions in Aging · doi:10.2147/cia.s423122 · Cited by 33
Meunier, L., Aguadé, A.-S., Videau, Y., Verboux, D., Fagot-Campagna, A., Gastaldi-Menager, C., & Amadou, C. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0112 · Cited by 22
Insulin pump therapy for type 2 diabetes mellitus
Pickup, J. C. (2014) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2014.142 · Cited by 22
Roze, S., Duteil, E., Smith‐Palmer, J., de Portu, S., Valentine, W. J., Brouwer, B. F. E. D., Reznik, Y., & de Valk, H. W. (2016) · Journal of Medical Economics · doi:10.3111/13696998.2016.1167695 · Cited by 22
Self-citationSUTTON, D. R., Higdon, C., NIKKEL, C. C., & Hilsinger, K. A. (2018) · Advances in Therapy · doi:10.1007/s12325-018-0703-3 · Cited by 21
Banting Memorial Lecture 2014 Technology and diabetes care: appropriate and personalized
Pickup, J. C. (2014) · Diabetic Medicine · doi:10.1111/dme.12613 · Cited by 22
Clinical practice points for diabetes management during RAMADAN fast
SADIKOT, S. M., Jothydev, K., Zargar, A. H., Ahmad, J., Arvind, S. R., & Saboo, B. (2017) · Diabetes & Metabolic Syndrome Clinical Research & Reviews · doi:10.1016/j.dsx.2017.06.003 · Cited by 21
Carlson, A. L., Huyett, L. M., Jantz, J., Chang, A., Vienneau, T., & Ly, T. T. (2021) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2021.108735 · Cited by 20
The use of technology in type 2 diabetes and prediabetes: a narrative review
Liarakos, A. L., Lim, J. Z. M., Leelarathna, L., & Wilmot, E. G. (2024) · Diabetologia · doi:10.1007/s00125-024-06203-7 · Cited by 27
Morera, J., Joubert, M., Morello, R., Rod, A., Lireux, B., & Reznik, Y. (2016) · Diabetes Care · doi:10.2337/dc16-0287 · Cited by 20
Self-citationBrixner, D. I., Ermakova, A., Xiong, Y., Sieradzan, R., Sacks, N. C., Cyr, P. L., & Taylor, S. (2019) · Clinical Therapeutics · doi:10.1016/j.clinthera.2018.12.014 · Cited by 18
Guzmán, G. E., Martínez, V., Yara, J., Mina, M. A., Solarte, J. S., Victoria‐Castro, A. M., & Fériz, K. (2020) · Journal of Diabetes Research · doi:10.1155/2020/1581726 · Cited by 19
Christensen, M. B., Serifovski, N., Herz, A. M. H., Schmidt, S., Hommel, E. E., RAIMOND, L. H., Perrild, H., Gotfredsen, A., Gæde, P., & Nørgaard, K. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0276 · Cited by 23
Mader, J. K., Lilly, L. C., Aberer, F., Poettler, T., Johns, D., TRAUTMANN, M. E., WARNER, J. L., & Pieber, T. R. (2018) · Diabetic Medicine · doi:10.1111/dme.13708 · Cited by 18
Li, F.-F., Liu, B.-L., Zhu, H., Li, T., Zhang, W., Su, X., Wu, J.-D., Wang, X., Xu, N., Yu, W., et al. (2017) · Journal of Diabetes Research · doi:10.1155/2017/2740372 · Cited by 19
Galderisi, A., Tremblay, E. S., & Cengiz, E. (2017) · Current Diabetes Reports · doi:10.1007/s11892-017-0944-6 · Cited by 20
A qualitative study exploring patients’ experiences regarding insulin pump use
Alsairafi, Z. K., Smith, F. J., Taylor, K. M. G., Alsaleh, F. M., & Alattar, A. (2018) · Saudi Pharmaceutical Journal · doi:10.1016/j.jsps.2018.02.010 · Cited by 18
Schliess, F., Heise, T., Benesch, C., Mianowska, B., Stegbauer, C., Broge, B., Gillard, P., Binkley, G., Crône, V., Carlier, S., et al. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818803588 · Cited by 17
Diabetology 4.0: Scoping Review of Novel Insights and Possibilities Offered by Digitalization
Eberle, C., Stichling, S., & Löhnert, M. (2021) · Journal of Medical Internet Research · doi:10.2196/23475 · Cited by 21
Werzowa, J. M., Säemann, M. D., Mohl, A., Bergmann, M. M., Kaltenecker, C. C., Brozek, W., Thomas, A., Haidinger, M., Antlanger, M., Kovarik, J. J., et al. (2018) · PLoS ONE · doi:10.1371/journal.pone.0193569 · Cited by 17
Management of Hyperglycemia in Older Adults with Type 2 Diabetes
Gandhi, G. Y., & Mooradian, A. D. (2021) · Drugs & Aging · doi:10.1007/s40266-021-00910-1 · Cited by 18
Relationship between the insulin use and stigma in type 2 diabetes mellitus
Aslan, E. Ö., Toygar, İ., Feyizoğlu, G., Polat, S., & Aslan, F. E. (2023) · Primary care diabetes · doi:10.1016/j.pcd.2023.05.002 · Cited by 19
Treatment with continuous subcutaneous insulin infusion is associated with lower arterial stiffness
Rosenlund, S. V., Theilade, S., Hansen, T. W., Andersen, S., & Rossing, P. R. (2014) · Acta Diabetologica · doi:10.1007/s00592-014-0619-6 · Cited by 16
Efficacy of Insulin Pump Therapy in Elderly Patients
Yeoh, E. C. K., Beato-Víbora, P. I., Rogers, H., Amiel, S. A., & Choudhary, P. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0360 · Cited by 17
Emerging technologies for the management of type 2 diabetes mellitus
Shah, N. A., & Levy, C. J. (2021) · Journal of Diabetes · doi:10.1111/1753-0407.13188 · Cited by 18
Cohen, O., Filetti, S., Castañeda, J., Maranghi, M., & Glandt, M. (2016) · Diabetes Care · doi:10.2337/dcs15-3029 · Cited by 18
Self-citationEveritt, B., Harrison, H. C., NIKKEL, C. C., Laswell, E. M., & Chen, A. M. H. (2018) · Research in Social and Administrative Pharmacy · doi:10.1016/j.sapharm.2018.09.016 · Cited by 14
Schöttler, H., Auzanneau, M., Best, F., Braune, K., Freff, M., Heidtmann, B., Jung, R., Karges, B., Klee, D., Müller, A., et al. (2020) · Diabetologie und Stoffwechsel · doi:10.1055/a-1259-1190 · Cited by 15
Diabetes Technology in People with Type 2 Diabetes: Novel Indications
Agarwal, S., Galindo, R. J., Shah, A. V., & Abreu, M. (2024) · Current Diabetes Reports · doi:10.1007/s11892-024-01536-4 · Cited by 12
von Bibra, H., Siegmund, T., Kingreen, I., Riemer, M., Schuster, T., & Schumm‐Draeger, P. (2016) · Cardiovascular Diabetology · doi:10.1186/s12933-015-0320-2 · Cited by 13
Joubert, M., Opigez, V., Pavlikova, B., Peyro Saint Paul, L., Jeandidier, N., Briant, A. R., Parienti, J., & Reznik, Y. (2021) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.14225 · Cited by 13
Self-citationLi, F.-F., Zhang, Y., Zhang, W., Liu, X., Chen, M.-Y., Sun, Y., Su, X., Wu, J.-D., Ye, L., & Ma, J. (2018) · Diabetes Therapy · doi:10.1007/s13300-018-0492-3 · Cited by 14
Insulin Management for Gestational and Type 2 Diabetes in Pregnancy
Valent, A. M., & Barbour, L. A. (2024) · Obstetrics and Gynecology · doi:10.1097/aog.0000000000005640 · Cited by 17
Chow, N., Shearer, D., Tildesley, H. G., Plaa, J. A., Pottinger, B., Pawlowska, M., White, A. S., Priestman, A., Ross, S., & Tildesley, H. (2016) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2015-000145 · Cited by 11
Wang, Y., Lu, J., Wang, M., Ni, J., Yu, J., Wang, S., Wu, L., Lu, W., Zhu, W., Guo, J., et al. (2024) · The Lancet Regional Health - Western Pacific · doi:10.1016/j.lanwpc.2024.101067 · Cited by 21
Zhang, Y., Zhao, Z., Wang, S., Zhu, W., Jiang, Y., Sun, S., Chen, C., Wang, K., Mu, L., Cao, J., et al. (2017) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.2913 · Cited by 10
Management of type 2 diabetes in the new era
Liakos, A., Karagiannis, T., Avgerinos, I., Malandris, K., Τσάπας, Α., & Bekiari, E. (2023) · HORMONES · doi:10.1007/s42000-023-00488-w · Cited by 13
Anstey, J., Yassaee, A., & Solomon, A. (2015) · Diabetic Medicine · doi:10.1111/dme.12740 · Cited by 13
[Studies on distribution, excretion and subacute toxicity of squalane in dogs].
Kamimura, H., Koga, N., OGURI, K., Yoshimura, H., Inoue, H., Sato, K., & Ohkubo, M. (1989) · PubMed · Cited by 19
Metadata
- Authors
- Reznik, Y., Cohen, O., Aronson, R., Conget, I., Runzis, S., Castaneda, J., & Lee, S. W.
- Affiliations
- Centre Hospitalier Universitaire de Caen Normandie (FR)
- Sheba Medical Center (IL)
- LMC Diabetes & Endocrinology (Canada) (CA)
- Hospital Clínic de Barcelona (ES)
- Medtronic (Switzerland) (CH)
- Corresponding author
- Reznik, Yves
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2014-10
- Volume
- 384
- Issue
- 9950
- Pages
- 1265-1272
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2131145650
- Cited by
- 233
- References
- 25
- Citations by year
- 2026: 8 · 2025: 15 · 2024: 18 · 2023: 22 · 2022: 9 · 2021: 19 · 2020: 18 · 2019: 17 · 2018: 34 · 2017: 23 · 2016: 19 · 2015: 21 · 2014: 9
- FWCI
- 19.29
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- type 2 diabetes, insulin pump therapy, multiple daily insulin injections, HbA1c, glycemic control, insulin analogues, total daily insulin dose, insulin-treated patients, HbA1c reduction, hypoglycemia, body weight
- MeSH terms
- Adult, Aged, Diabetes Mellitus, Type 2, Drug Administration Schedule, Female, Glycated Hemoglobin, Humans, Hypoglycemic Agents, Injections, Subcutaneous, Insulin, Insulin Infusion Systems, Male, Middle Aged
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.