STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 10,801–10,900 of 47,868
Paproki, A., ENGSTROM, C. M., Chandra, S. S., Neubert, A., Fripp, J., & Crozier, . (2014) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2014.06.029 · Cited by 53
Gao, Z., Hau, W. K., Lu, M., Huang, W., Zhang, H., Wu, W., Liu, X., & Zhang, Y. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.03.022 · Cited by 48
Barden, A. E., Mas, E., Croft, K. D., Phillips, M. R., & Mori, T. A. (2014) · Analytical Biochemistry · doi:10.1016/j.ab.2013.12.030 · Cited by 46
The Test–Retest Reliability of the Photopic Negative Response (PhNR)
Tang, J. J., Edwards, T. L., Crowston, J. G., & Sarossy, M. (2014) · Translational Vision Science & Technology · doi:10.1167/tvst.3.6.1 · Cited by 46
Sedaghat, M. R., Daneshvar, R., Kargozar, A., Derakhshan, A., & Daraei, M. (2010) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2010.06.013 · Cited by 46
Izquierdo‐Garcia, D., Sawiak, S. J., Knešaurek, K., Narula, J., Fuster, V., Machac, J., & Fayad, Z. A. (2014) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2751-5 · Cited by 46
Has My Patient Responded?: Interpreting Clinical Measurements Such As the 6-Minute-Walk Test
Dolmage, T. E., Hill, K., Evans, R. A., & Goldstein, R. S. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201103-0497cc · Cited by 48
Validation of an immunoassay for measurement of canine cardiac troponin-I
Oyama, M. A., & Solter, P. F. (2004) · Journal of Veterinary Cardiology · doi:10.1016/s1760-2734(06)70054-6 · Cited by 47
Hassan, E. A., Jenkyn, T. R., & Dunning, C. E. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.03.019 · Cited by 59
Shah, N., Laidlaw, D. A. H., Rashid, S., & Hysi, P. G. (2011) · Eye · doi:10.1038/eye.2011.333 · Cited by 46
Keller, A. S., Melamed, R., Malinchoc, M., John, R. M., Tierney, D. M., & Gajic, O. (2009) · Journal of Hospital Medicine · doi:10.1002/jhm.503 · Cited by 46
van Loon, J. P. A. M., Jonckheer-Sheehy, V. S. M., Back, W., van Weeren, P. R., & Hellebrekers, L. J. (2014) · The Veterinary Journal · doi:10.1016/j.tvjl.2014.01.003 · Cited by 62
Al-Rahamneh, H. Q., & Eston, R. G. (2011) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2010.10.017 · Cited by 46
Aoki, T., Rodriguez-Porcel, M. G., Matsuo, Y., Cassar, A., Kwon, T.-G., Franchi, F., Gulati, R., Kushwaha, S. S., Lennon, R. J., Lerman, L. O., et al. (2015) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2015.01.016 · Cited by 46
Gustafsson, U., Lindqvist, P., Mörner, S., & Waldenström, A. P. (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jen141 · Cited by 46
Accuracy and Repeatability of the Gait Analysis by the WalkinSense System
de Castro, M. P., Meucci, M., Soares, D. P., Fonseca, P., Borgonovo-Santos, M., Sousa, F., Machado, L. J., & Vilas‐Boas, J. P. (2014) · BioMed Research International · doi:10.1155/2014/348659 · Cited by 46
Estimation of central pressure augmentation using automated radial artery tonometry
Melenovský, V., Borlaug, B. A., Fetics, B. J., Kessler, K., Shively, L., & Kass, D. A. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e32811d69df · Cited by 51
Central Corneal Thickness Measured With Three Optical Devices and Ultrasound Pachometry
González-Pérez, J., González‐Méijome, J. M., Ares, M. T. R., & Parafita, M. Á. (2011) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/icl.0b013e31820c6ffc · Cited by 46
Peng, H., Chung, H., Yu, H., & Tseng, W. I. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20782 · Cited by 46
Comparison of Different Methods for the Calculation of the Microvascular Flow Index
Pozo, M. O., Edul, V. S. K., İnce, C., & Dubín, A. (2012) · Critical Care Research and Practice · doi:10.1155/2012/102483 · Cited by 46
Pulpal status of human primary teeth with physiological root resorption
Monteiro, J., Day, P. F., Duggal, M. S., Morgan, C. R., & RODD, H. D. (2008) · International Journal of Paediatric Dentistry · doi:10.1111/j.1365-263x.2008.00963.x · Cited by 46
Reference standard of penile size and prevalence of buried penis in Japanese newborn male infants
Matsuo, N., Ishii, T., Takayama, J. I., Miwa, M., & Hasegawa, T. (2014) · Endocrine Journal · doi:10.1507/endocrj.ej14-0069 · Cited by 47
Gasq, D., Labrunée, M., Amarantini, D., Dupui, P., Montoya, R., & Marqué, P. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-39 · Cited by 46
TEG® Functional Fibrinogen Analysis May Overestimate Fibrinogen Levels
Ågren, A., Wikman, A. T., Östlund, A., & Edgren, G. (2014) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000172 · Cited by 46
Test-Retest Reliability of the StepWatch Activity Monitor Outputs in Healthy Adults
Mudge, S., Taylor, D., Chang, O., & Wong, R. (2010) · Journal of Physical Activity and Health · doi:10.1123/jpah.7.5.671 · Cited by 47
EIA and GC/MS analysis of 8-isoprostane in EBC of children with problematic asthma
Carraro, S., Cogo, P. E., Isak, I., Simonato, M., Corradi, M., Carnielli, V. P., & Baraldi, E. (2009) · European Respiratory Journal · doi:10.1183/09031936.00074909 · Cited by 48
O'Toole, E., Miller, C. W., WILSON, B. A., Mathews, K. A., Davis, C., & Sears, W. (2004) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.2004.225.58 · Cited by 46
Gu, D., Zhao, Q., Chen, J., Chen, J.-C., Huang, J., Bazzano, L. A., Lu, F., Mu, J., Li, J., Cao, J., et al. (2013) · Hypertension · doi:10.1161/hypertensionaha.113.01034 · Cited by 44
Patankar, K., Low, R. S.-T., Blakeway, D., & Ferrari, P. (2013) · Acta Radiologica · doi:10.1177/0284185113504195 · Cited by 46
Kim, J., Kim, K.-B., Kim, W., Kim, J., & Kim, H. (2014) · The Korean Journal of Orthodontics · doi:10.4041/kjod.2014.44.2.69 · Cited by 46
Sohal, M., Duckett, S. G., Zhuang, X., Shi, W., Ginks, M., Shetty, A., Sammut, E. C., Kozerke, S., Niederer, S., Smith, N. P., et al. (2014) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/preaccept-1270501173126876 · Cited by 46
van Bussel, B. C. T., Ferreira, I., van de Waarenburg, M. P. H., van Greevenbroek, M. M. J., Kallen, C., Henry, R. M. A., Feskens, E. J. M., Stehouwer, C. D. A., & Schalkwijk, C. G. (2013) · PLoS ONE · doi:10.1371/journal.pone.0058576 · Cited by 47
Cho, H. Y., Kim, J. H., Kim, S. W., Shin, C. S., Park, K. S., Kim, S. W., Jang, H., & Kim, S. Y. (2014) · Clinical Endocrinology · doi:10.1111/cen.12397 · Cited by 46
Kellett, J. G., Li, M., Rasool, S., Green, G. C., & SEELY, A. J. E. (2011) · Resuscitation · doi:10.1016/j.resuscitation.2011.07.013 · Cited by 46
Oyeyemi, A. L., Bello, U. M., Philemon, S. T., Aliyu, H. N., Majidadi, R. W., & Oyeyemi, A. Y. (2014) · BMJ Open · doi:10.1136/bmjopen-2014-005820 · Cited by 54
Wright, F. V., Rosenbaum, P., Fehlings, D. L., Mesterman, R., Breuer, U., & Kim, M. (2014) · Developmental Medicine & Child Neurology · doi:10.1111/dmcn.12453 · Cited by 46
Hofhuizen, C., Lemson, J., Hemelaar, A. E. A., Settels, J. J., Schraa, O., Singh, S. K., van der Hoeven, J. G., & Scheffer, G. J. (2010) · British Journal of Anaesthesia · doi:10.1093/bja/aeq201 · Cited by 50
Creed, B., Kau, C. H., English, J. D., Xia, J. J., & Lee, R. P. (2011) · Seminars in Orthodontics · doi:10.1053/j.sodo.2010.08.010 · Cited by 46
Sullivan, B. L., Brown, J., Williams, P., & Meyer, B. J. (2008) · British Journal Of Nutrition · doi:10.1017/s0007114507837408 · Cited by 55
Freckmann, G., Link, M., Schmid, C., Pleus, S., Baumstark, A., & Haug, C. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0085 · Cited by 46
Bell, A., Rawlins, D., Bellsham‐Revell, H., Miller, O., Razavi, R., & Simpson, J. M. (2013) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jet145 · Cited by 46
Anast, N., Olejniczak, M. J., Ingrande, J., & Brock‐Utne, J. G. (2015) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-015-0509-6 · Cited by 50
Nyström, C. D., Forsum, E., Henriksson, H., Lagerros, Y. T., Larsson, C. L., Maddison, R., Timpka, T., & Löf, M. (2016) · Nutrients · doi:10.3390/nu8010050 · Cited by 53
Physical employment standards for UK fire and rescue service personnel
Blacker, S. D., Rayson, M. P., Wilkinson, D. M., Carter, J. M., Nevill, A. M., & Richmond, V. L. (2015) · Occupational Medicine · doi:10.1093/occmed/kqv122 · Cited by 46
Sigmundsson, H., Lorås, H. W., & Haga, M. (2016) · SAGE Open · doi:10.1177/2158244016633273 · Cited by 61
Iwahori, T., Ueshima, H., Torii, S., Saito, Y., Fujiyoshi, A., Ohkubo, T., & Miura, K. (2015) · Journal of Human Hypertension · doi:10.1038/jhh.2015.84 · Cited by 50
Validity and reliability of physical employment standards
Milligan, G. S., Reilly, T. J., Zumbo, B. D., & Tipton, M. (2016) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2015-0669 · Cited by 53
Mann, J. B., Ivey, P. A., Mayhew, J. L., Schumacher, R. M., & Brechue, W. F. (2016) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001329 · Cited by 66
Lopes, V. P., Barnett, L. M., Saraiva, L., Gonçalves, C., Bowe, S. J., Abbott, G., & Rodrigues, L. P. (2016) · Child Care Health and Development · doi:10.1111/cch.12359 · Cited by 50
Spectral Matrix Decomposition-Based Motion Artifacts Removal in Multi-Channel PPG Sensor Signals
Xiong, J., Cai, L., Jiang, D., Song, H., & He, X. (2016) · IEEE Access · doi:10.1109/access.2016.2580594 · Cited by 47
Fukuoka, Y., Haskell, W. L., & Vittinghoff, E. (2016) · BMC Public Health · doi:10.1186/s12889-016-3348-7 · Cited by 49
Augmented renal clearance in Japanese intensive care unit patients: a prospective study
Kawano, Y., Morimoto, S., Izutani, Y., Muranishi, K., Kaneyama, H., Hoshino, K., Nishida, T., & Ishikura, H. (2016) · Journal of Intensive Care · doi:10.1186/s40560-016-0187-7 · Cited by 46
Reliability and construct validity of the test of gross motor development-2 in Portuguese children
Lopes, V. P., Saraiva, L., & Rodrigues, L. P. (2016) · International Journal of Sport and Exercise Psychology · doi:10.1080/1612197x.2016.1226923 · Cited by 53
Investigating the Practical Consequences of Model Misfit in Unidimensional IRT Models
Crișan, D. R., Tendeiro, J. N., & Meijer, R. R. (2017) · Applied Psychological Measurement · doi:10.1177/0146621617695522 · Cited by 57
Wong, S. M., Jansen, J. F. A., Zhang, C. E., Staals, J., Hofman, P. A. M., van Oostenbrugge, R. J., Jeukens, C. R. L. P. N., & Backes, W. H. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25540 · Cited by 45
Gough, L. A., Deb, S. K., Sparks, A. S., & McNaughton, L. R. (2017) · Sports Medicine · doi:10.1007/s40279-017-0699-x · Cited by 44
Brozmanová, H., Kacířová, I., Uřinovská, R., Šištík, P., & Grundmann, M. (2017) · Clinica Chimica Acta · doi:10.1016/j.cca.2017.04.003 · Cited by 46
The contribution of alliaceous and cruciferous vegetables to dietary sulphur intake
Doleman, J. F., Grisar, K., Liedekerke, L. V., Saha, S., Roe, M. A., Tapp, H. S., & Mithen, R. F. (2017) · Food Chemistry · doi:10.1016/j.foodchem.2017.04.098 · Cited by 46
Assessment of automatic segmentation of teeth using a watershed-based method
Galibourg, A., Dumoncel, J., Telmon, N., Calvet, A., Michetti, J., & Maret, D. (2017) · Dentomaxillofacial Radiology · doi:10.1259/dmfr.20170220 · Cited by 49
Gastric emptying for liquids of different compositions in children
Du, T., Hill, L., Ding, L., Towbin, A. J., DeJonckheere, M. J., Bennett, P., Hagerman, N. S., Varughese, A. M., & Pratap, J. “. (2017) · British Journal of Anaesthesia · doi:10.1093/bja/aex340 · Cited by 50
Young Schema Questionnaire – Short Form Version 3 (YSQ-S3): Preliminary validation in older adults
Phillips, K., Brockman, R. N., Bailey, P. E., & Kneebone, I. (2017) · Aging & Mental Health · doi:10.1080/13607863.2017.1396579 · Cited by 56
Holland, R., Tillett, W. L., Korendowych, E., Cavill, C., Waldron, N., Brooke, M., & McHugh, N. J. (2017) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2017-211996 · Cited by 51
Animal-Based Measures to Assess the Welfare of Extensively Managed Ewes
Munoz, C. A., Campbell, A. J. D., Hemsworth, P. H., & Doyle, R. E. (2017) · Animals · doi:10.3390/ani8010002 · Cited by 46
Stoustrup, P. B., Iversen, C. K., Kristensen, K. D., Resnick, C. M., Verna, C., Nørholt, S. E., Abramowicz, S., Küseler, A., Cattaneo, P. M., Herlin, T., et al. (2018) · PLoS ONE · doi:10.1371/journal.pone.0194177 · Cited by 46
Snaith, B. A., Harris, M., Shinkins, B., Jordaan, M., Messenger, M. P., & Lewington, A. J. P. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0128 · Cited by 47
Reliability of a novel thermal imaging system for temperature assessment of healthy feet
Petrova, N. L., Whittam, A., Macdonald, A., Ainarkar, S., Donaldson, N., Bevans, J., Allen, J., Plassmann, P., Kluwe, B., Ring, F. J., et al. (2018) · Journal of Foot and Ankle Research · doi:10.1186/s13047-018-0266-1 · Cited by 47
Validity of the Kinect and Myo armband in a serious game for assessing upper limb movement
Esfahlani, S. S., Muresan, B., Sanaei, A., & Wilson, G. B. (2018) · Entertainment Computing · doi:10.1016/j.entcom.2018.05.003 · Cited by 47
Stabouli, S., Printza, N. G., Zervas, C., Dotis, J., Chrysaidou, K., Maliahova, O., Antza, C., Papachristou, F., & Kotsis, V. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001819 · Cited by 50
Developing a video‐based method to compare and adjust examiner effects in fully nested OSCEs
Yeates, P., Cope, N. A., Hawarden, A., Bradshaw, H., McCray, G., & Homer, M. (2018) · Medical Education · doi:10.1111/medu.13783 · Cited by 49
Verheul, J., Gregson, W. A., Lisboa, P. J. G., Vanrenterghem, J., & Robinson, M. A. (2018) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2018.12.007 · Cited by 52
EMFIT QS heart rate and respiration rate validation
Ranta, J., Aittokoski, T., Tenhunen, M. L., & Alasaukko-oja, M. (2019) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aafbc8 · Cited by 50
Backhaus, S. J., Metschies, G., Billing, M., Kowallick, J. T., Gertz, R. J., Lapinskas, T., Pieske, B. M., Lotz, J., Bigalke, B., Kutty, S., et al. (2019) · PLoS ONE · doi:10.1371/journal.pone.0210127 · Cited by 53
Automated Detection and Segmentation of Multiple Sclerosis Lesions Using Ultra–High-Field MP2RAGE
Fartaria, M. J., Sati, P., Todea, R., Radue, E. W., Rahmanzadeh, R., O’Brien, K., Reich, D. S., Cuadra, M. B., Kober, T., & Granziera, C. (2019) · Investigative Radiology · doi:10.1097/rli.0000000000000551 · Cited by 49
Schuster, A., Backhaus, S. J., Stiermaier, T., Kowallick, J. T., Stulle, A., Koschalka, A., Lotz, J., Kutty, S., Bigalke, B., Gutberlet, M., et al. (2019) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jez077 · Cited by 46
Backhaus, S. J., Staab, W., Steinmetz, M., Ritter, C. O., Lotz, J., Hasenfuss, G. P., Schuster, A., & Kowallick, J. T. (2019) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-019-0532-9 · Cited by 52
The Noninvasive Blood Pressure Measurement Based on Facial Images Processing
Zhou, Y., Ni, H., Zhang, Q., & Wu, Q. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2931775 · Cited by 46
Estimation of Thickness and Speed of Sound in Cortical Bone Using Multifocus Pulse-Echo Ultrasound
Minh, H. N., Du, J., & Raum, K. (2019) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2019.2948896 · Cited by 54
consensusDE: an R package for assessing consensus of multiple RNA-seq algorithms with RUV correction
Waardenberg, A. J., & Field, M. A. (2019) · PeerJ · doi:10.7717/peerj.8206 · Cited by 53
Winkel, D. J., Weikert, T., Breit, H., Chabin, G., Gibson, E., Heye, T. J., Comaniciu, D., & Boll, D. T. (2020) · European Journal of Radiology · doi:10.1016/j.ejrad.2020.108918 · Cited by 52
SLIPS-LAB—A bioinspired bioanalysis system for metabolic evaluation of urinary stone disease
Li, H., Shkolyar, E., Wang, J., Conti, S. L., Pao, A. C., Liao, J. C., Wong, T., & Wong, P. K. (2020) · Science Advances · doi:10.1126/sciadv.aba8535 · Cited by 52
Hamilton, J., Jiang, Y., Eck, B., Griswold, M. A., & Seiberlich, N. (2020) · NMR in Biomedicine · doi:10.1002/nbm.4323 · Cited by 51
Giorno, R. D., Troiani, C., Gabutti, S., Stefanelli, K., & Gabutti, L. (2020) · Annals of Medicine · doi:10.1080/07853890.2020.1794538 · Cited by 53
Saugel, B., Thiele, R. H., Hapfelmeier, A., & Cannesson, M. P. (2020) · Anesthesiology · doi:10.1097/aln.0000000000003483 · Cited by 47
Comparison Between Actigraphy Records and Parental Reports of Child's Sleep
Perpétuo, C., Fernandes, M., & Veríssimo, M. (2020) · Frontiers in Pediatrics · doi:10.3389/fped.2020.567390 · Cited by 60
Detecting methanol in hand sanitizers
Güntner, A. T., Magro, L., van den Broek, J., & Pratsinis, S. E. (2021) · iScience · doi:10.1016/j.isci.2021.102050 · Cited by 48
Yu, J. Y., Goldberg, T., Lao, N., Feldman, B. M., & Goh, Y. I. (2021) · Pediatric Rheumatology · doi:10.1186/s12969-021-00551-z · Cited by 51
Changes in Respiratory Muscle Thickness during Mechanical Ventilation: Focus on Expiratory Muscles
Shi, Z., de Vries, H. J., de Grooth, H., Jonkman, A. H., Zhang, Y., Haaksma, M. E., van de Ven, P. M., de Man, A., Girbes, A. R. J., Tuinman, P. R., et al. (2021) · Anesthesiology · doi:10.1097/aln.0000000000003736 · Cited by 56
Imaeda, N., Goto, C., Sasakabe, T., Mikami, H., Oze, I., Hosono, A., Naito, M., Miyagawa, N., Ozaki, E., Ikezaki, H., et al. (2021) · Environmental Health and Preventive Medicine · doi:10.1186/s12199-021-00951-3 · Cited by 58
Validity of Accelerometry for Measurement of Activity in People with Brain Injury
Tweedy, S. M., & Trost, S. G. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000177584.43330.ae · Cited by 46
Carbon monoxide uptake kinetics of arterial, venous and capillary blood during CO rebreathing
Garvican, L. A., Burge, C. M., Cox, A. J., Clark, S. A., Martin, D. T., & Gore, C. J. (2010) · Experimental Physiology · doi:10.1113/expphysiol.2010.054031 · Cited by 39
Resting energy expenditure in children with phenylketonuria
Allen, J., McCauley, J. C., Waters, D., O’Connor, J., Dc, R., & Gaskin, K. (1995) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/62.4.797 · Cited by 46
Martins, W. P., Ferriani, R. A., Barra, D. D. A., dos Reis, R. M., Bortolieiro, M. A. V., Nastri, C. O., & Filho, F. M. (2007) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.3916 · Cited by 46
INTRA- AND INTER-RATER RELIABILITY OF THE ASSESSMENT OF CAPACITY FOR MYOELECTRIC CONTROL
Hermansson, L., Bodin, L., & Eliasson, A. (2005) · Journal of Rehabilitation Medicine · doi:10.1080/16501970500312222 · Cited by 46
Estimation of regional bone metabolism from whole-body 18F-fluoride PET static images
Siddique, M. M., Blake, G. M., Frost, M. L., Moore, A. E. B., Puri, T., Marsden, P. K., & Fogelman, I. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-011-1966-y · Cited by 46
Deveci, F., Murat, A., Turgut, T., Altuntaş, E., & Muz, M. H. (2004) · Respiration · doi:10.1159/000081761 · Cited by 48
Moolenburgh, S. E., Mureau, M. A. M., Duivenvoorden, H. J., & Hofer, S. O. P. (2008) · Journal of Plastic Reconstructive & Aesthetic Surgery · doi:10.1016/j.bjps.2007.07.024 · Cited by 46
Pennati, G., Bellotti, M., Ferrazzi, E. M., Bozzo, M., Pardi, G., & Fumero, R. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00011-8 · Cited by 46
Bault, J. P., Salomon, L. J., Guibaud, L., & Achiron, R. (2010) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.8847 · Cited by 46
Eide, P. K., & Brean, A. (2006) · British Journal of Neurosurgery · doi:10.1080/02688690601047312 · Cited by 46
Moon, J. R., Smith, A. E., Tobkin, S. E., Lockwood, C. M., Kendall, K. L., Graef, J. L., Roberts, M. D., Dalbo, V. J., Kerksick, C. M., Cramer, J. T., et al. (2009) · Clinical Nutrition · doi:10.1016/j.clnu.2009.04.025 · Cited by 47
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.