STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 10,701–10,800 of 47,868
Sex difference in force generation capacity during repeated maximal knee extensions
Kanehisa, H., Okuyama, H., Ikegawa, S., & Fukunaga, T. (1996) · European Journal of Applied Physiology · doi:10.1007/bf00357679 · Cited by 58
Giguère, S., Bucki, E., Adin, D. B., Valverde, A., Estrada, A. H., & Young, L. J. (2005) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.2005.tb02754.x · Cited by 47
Sharpe, J.-K., Byrne, N. M., STEDMAN, T. J., & Hills, A. P. (2005) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2005.01.005 · Cited by 53
Philippaerts, R. M., Lefevre, J., Delvaux, K., Thomis, M. A., Vanreusel, B., Eynde, B. V., Claessens, A., Lysens, R., & Beunen, G. P. (1999) · American Journal of Human Biology · doi:10.1002/(sici)1520-6300(199909/10)11:5<587::aid-ajhb2>3.0.co;2-s · Cited by 16
Hirschl, M. M., Kittler, H., Woisetschläger, C., Siostrzonek, P., Staudinger, T., Kofler, J., Oschatz, E., Bur, A., Gwechenberger, M., & Laggner, A. N. (2000) · Critical Care Medicine · doi:10.1097/00003246-200006000-00017 · Cited by 47
Lucas, C., Classen, J., Harrison, D., & de Haan, R. J. (2002) · Advances in Skin & Wound Care · doi:10.1097/00129334-200201000-00009 · Cited by 47
Limitations in Anthropometric Calculations of Total Body Water in Patients on Peritoneal Dialysis
Johansson, A. C., Samuelsson, O. G., Attman, P., Bosaeus, I. G., & Haraldsson, B. S. (2001) · Journal of the American Society of Nephrology · doi:10.1681/asn.v123568 · Cited by 47
Ryd, L., Kärrholm, J., Ahlvin, P., & The Score Assessment Group (1997) · Acta Orthopaedica Scandinavica · doi:10.3109/17453679709003973 · Cited by 58
Measurement of cardiac output in standing horses by Doppler echocardiography and thermodilution
BLISSITT, K. J., Young, L. E., Jones, R. S., Darke, P. G. G., & Utting, J. (1997) · Equine Veterinary Journal · doi:10.1111/j.2042-3306.1997.tb01631.x · Cited by 47
Daghini, E., Juillard, L., Haas, J. A., Krier, J. D., Romero, J. C., & Lerman, L. O. (2007) · Radiology · doi:10.1148/radiol.2422052144 · Cited by 48
Lührmann, P. M., Herbert, B. M., Krems, C., & Neuhäuser‐Berthold, M. (2002) · European Journal of Nutrition · doi:10.1007/s003940200016 · Cited by 55
Buño, I., Nava, P., Simón, A., González‐Rivera, M., Jiménez, J. L., Balsalobre, P., Serrano, D., Carrión, R., Gómez-Pineda, A., & Díez-Martín, J. L. (2005) · PubMed · Cited by 47
DXA-Generated Z-Scores and T-Scores May Differ Substantially and Significantly in Young Adults
CAREY, J. J., Delaney, M. F., Love, T. E., Richmond, B. J., Cromer, B. A., Miller, P. D., Manilla-McIntosh, M., Lewis, S., Thomas, C. L., & Licata, A. A. (2007) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2007.06.001 · Cited by 62
Alam, D. S., Hulshof, P. J. M., Roordink, D., Meltzer, M., Yunus, M., Salam, M. A., & Raaij, J. M. A. V. (2005) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602122 · Cited by 47
Samsa, G. P., Ortel, T. L., & Perry, S. L. (2005) · Thrombosis and Haemostasis · doi:10.1160/th05-06-0400 · Cited by 55
Cannesson, M. P., Slieker, J. C., Desebbe, O., Farhat, F., Bastien, O. H., & Lehot, J.-J. (2006) · Critical Care · doi:10.1186/cc5123 · Cited by 47
Emshoff, R., Bertram, S., Brandlmaier, I., Scheiderbauer, G., Rudisch, A., & Bodner, G. (2002) · Journal of Oral Rehabilitation · doi:10.1046/j.1365-2842.2002.00939.x · Cited by 47
Pilatou, M. C., Stewart, E. A., Maier, S. E., Fennessy, F. M., Hynynen, K., Tempany, C. M., & McDannold, N. J. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21688 · Cited by 47
Welles, E. G., Hall, A. S., & Carpenter, D. M. (2009) · Veterinary Clinical Pathology · doi:10.1111/j.1939-165x.2008.00084.x · Cited by 47
Design of a portable urine glucose monitoring system for health care
Park, H. D., Lee, K.-J., Yoon, H. R., & Nam, H. H. (2004) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2004.02.003 · Cited by 47
Castro‐Perez, J. M., Previs, S. F., McLaren, D. G., Shah, V., Herath, K. B., Bhat, G., Johns, D. G., Wang, S.-P., Mitnaul, L. J., Jensen, K., et al. (2010) · Journal of Lipid Research · doi:10.1194/jlr.d009787 · Cited by 47
Ikegami, S., Moriwake, T., Tanaka, H., Inoue, M., Kubo, T., Suzuki, S., Kanzaki, S., & Seino, Y. (2001) · Clinical Endocrinology · doi:10.1046/j.1365-2265.2001.01416.x · Cited by 47
Impact of Different Criteria for Defining Hypopneas in the Apnea-Hypopnea Index
Manser, R. L., Rochford, P. D., Pierce, R. J., Byrnes, G. B., & Campbell, D. A. (2001) · CHEST Journal · doi:10.1378/chest.120.3.909 · Cited by 55
Kimura, S., Hasebe, S., Miyata, M., Hamasaki, I., & Ohtsuki, H. (2007) · Japanese Journal of Ophthalmology · doi:10.1007/s10384-006-0410-5 · Cited by 47
Grunwald, G. K., SEAGLE, H. M., Peters, J. C., & Hill, J. O. (2001) · British Journal Of Nutrition · doi:10.1079/bjn2001404 · Cited by 47
Modifying Track Layout From Straight to Circular Has a Modest Effect on the 6-min Walk Distance
Bansal, V., Hill, K., Dolmage, T. E., Brooks, D., Woon, L. J., & Goldstein, R. S. (2008) · CHEST Journal · doi:10.1378/chest.07-2823 · Cited by 47
Frontomaxillary facial angle at 11 + 0 to 13 + 6 weeks' gestation—reproducibility of measurements
Plasencia, W., Dagklis, T., Sotiriadis, A., Borenstein, M., & Nicolaides, K. H. (2006) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.3907 · Cited by 48
Gilgen-Ammann, R., Taube, W., & Wyss, T. (2015) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001299 · Cited by 47
The Medial Rotation total knee replacement
Mannan, K., & Scott, G. (2009) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.91b6.22124 · Cited by 47
Joint space width in dysplasia of the hip: A CASE-CONTROL STUDY OF 81 ADULTS FOLLOWED FOR TEN YEARS
Jacobsen, S., Sonne‐Holm, S., Søballé, K., Gebuhr, P., & Lund, B. (2005) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.87b4.15522 · Cited by 53
Borysiak, M. D., Thompson, M. J., & Posner, J. D. (2016) · Lab on a Chip · doi:10.1039/c6lc00015k · Cited by 48
Reproducibility of ambulatory blood pressure measurements in essential hypertension
Zakopoulos, N. A., Nanas, S., Lekakis, J. P., Vemmos, K. N., Kotsis, V., Pitiriga, V. C., Stamatelopoulos, S., & Moulopoulos, S. D. (2001) · Blood Pressure Monitoring · doi:10.1097/00126097-200102000-00007 · Cited by 47
Blood pressure estimation using video plethysmography
Šećerbegović, A., Bergsland, J., Halvorsen, P. S., Suljanović, N., Mujčić, A., & Balasingham, I. (2016) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2016.7493307 · Cited by 52
Factors Affecting Vaulting After Implantable Collamer Lens Implantation
Kamiya, K., Shimizu, K., & Komatsu, M. (2009) · Journal of Refractive Surgery · doi:10.3928/1081597x-20090301-04 · Cited by 47
Freidhoff, L. R., Ehrlich, E., Meyers, D. A., & Marsh, D. G. (1987) · Journal of Allergy and Clinical Immunology · doi:10.1016/0091-6749(87)90283-1 · Cited by 47
Variation in measurement of ankle-brachial pressure index in routine clinical practice
Fisher, C., Burnett, A., Makeham, V., Kidd, J., Glasson, M., & Harris, J. P. (1996) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(96)70025-3 · Cited by 47
Mechanisms and consequences of large artery rigidity
Et-Taouil, K., Safar, M. E., & Plante, G. E. (2003) · Canadian Journal of Physiology and Pharmacology · doi:10.1139/y03-022 · Cited by 52
Coles, C. E., Cash, C. J. C., Treece, G. M., Miller, F. N. A. C., Hoole, A. C. F., Gee, A. H., Prager, R. W., Sinnatamby, R., Britton, P. D., Wilkinson, J. S., et al. (2007) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2007.06.016 · Cited by 47
Accuracy, reproducibility, and variability of hand-held dynamometry in motor neuron disease.
Goonetilleke, A., Modarres-Sadeghi, H., & Guiloff, R. J. (1994) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.57.3.326 · Cited by 48
The Reliability of the Low Back Outcome Score for Back Pain
Holt, A. E., Shaw, N. J., Shetty, A., & Greenough, C. G. (2002) · Spine · doi:10.1097/00007632-200201150-00017 · Cited by 47
Paton, N. I., Elia, M., Jennings, G., Ward, L. C., & Griffin, G. E. (1998) · Nutrition · doi:10.1016/s0899-9007(98)00105-1 · Cited by 54
A comparison of transcutaneous bilirubinometers: SpectRx BiliCheck versus Minolta AirShields
Wong, C. M., van Dijk, P. J. E., & Laing, I. A. (2002) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/fn.87.2.f137 · Cited by 48
Jöbsis, Q., Schellekens, S. L., Kroesbergen, A., Hop, W., & de Jongste, J. C. (1999) · European Respiratory Journal · doi:10.1183/09031936.99.13614119 · Cited by 48
Desjardins, R., Denault, A. Y., Bélisle, S. J., Carrier, M., Babin, D., Lévesque, S., & Martineau, R. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-2052-0 · Cited by 47
Evaluation of methods for MR imaging of human right ventricular heart volumes and mass
Jauhiainen, T., Järvinen, V. M., & Hekali, P. E. (2002) · Acta Radiologica · doi:10.1034/j.1600-0455.2002.430609.x · Cited by 47
Estagnasié, P., Djedaïni, K., Mier, L., Coste, F., & Dreyfuss, D. (1997) · Intensive Care Medicine · doi:10.1007/s001340050405 · Cited by 48
Agreement between Noninvasive Oximetric Values for Oxygen Saturation
Cahan, C., Decker, M. J., Hoekje, P. L., & Strohl, K. P. (1990) · CHEST Journal · doi:10.1378/chest.97.4.814 · Cited by 47
Schmidt, A. G., Gerst, M., Zhai, J., Carr, A. N., Pater, L. E., Kranias, E. G., & Hoit, B. D. (2002) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2002.121863 · Cited by 52
Quantification of evacuation proctography
Halligan, S., McGee, S., & Bartram, C. I. (1994) · Diseases of the Colon & Rectum · doi:10.1007/bf02049820 · Cited by 47
Clinical Neuroepidemiology: I. Diagnosis
Longstreth, W. T., Koepsell, T. D., & van Belle, G. (1987) · Archives of Neurology · doi:10.1001/archneur.1987.00520220087023 · Cited by 47
Reflectance Pulse Oximetry in Fetal Lambs
Dassel, A. C. M., Graaff, R., Aarnoudse, J. G., Elstrodt, J. M., Heida, P., Koelink, M. H., de Mul, F. F. M., & Greve, J. (1992) · Pediatric Research · doi:10.1203/00006450-199203000-00014 · Cited by 47
Angerer, P., Kothny, W., Störk, S., & von Schacky, C. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00969-4 · Cited by 46
Plow quantitation with echo‐planar phase‐contrast velocity mapping: In vitro and in vivo evaluation
Debatin, J. F., Leung, D. A., Wildermuth, S., Botnar, R. M., Felblinger, J., & McKinnon, G. C. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050607 · Cited by 47
Reliability of self-reported weight and height among State bank employees
Chor, D., Coutinho, E. S. F., & Laurenti, R. (1999) · Revista de Saúde Pública · doi:10.1590/s0034-89101999000100004 · Cited by 47
Automatic determination of left ventricular ejection fraction from gated blood-pool tomography.
Vanhove, C., Franken, P. R., Defrise, M., Momen, A., Everaert, H., & Bossuyt, A. M. (2001) · PubMed · Cited by 47
Yamashita, K., Nishiyama, T., Yokoyama, T., Abe, H., & Manabe, M. (2005) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03016534 · Cited by 47
Accuracy of telephone dietary recalls in elderly subjects
Dubois, S., & Boivin, J. (1990) · Journal of the American Dietetic Association · doi:10.1016/s0002-8223(21)01875-7 · Cited by 56
Pluim, B. M., Beyerbacht, H. P., Chin, J. C., Zwinderman, A. H., van der Laarse, A., Roos, A., Vliegen, H. W., & van der Wall, E. E. (1997) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a015479 · Cited by 51
Hofmann, T., Keck, A., Ingen, G. V., Šimić, O., Ostermeyer, J., & Meinertz, T. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00157-u · Cited by 47
Laser scanning tomography and stereophotogrammetry in three-dimensional optic disc analysis
Burk, R. O. W., Rohrschneider, K., Takamoto, T., V�lcker, H. E., & Schwartz, B. (1993) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/bf00918840 · Cited by 47
Collie, D. A., Wright, A., Williams, J., Hashemi, B., Stevenson, A. J., & Turnbull, C. M. (1994) · British Journal of Radiology · doi:10.1259/0007-1285-67-797-436 · Cited by 47
Edge detection versus densitometry for assessing coronary stenting quantitatively
Strauss, B. H., Juillière, Y., Rensing, B. J. W. M., Reiber, J. H. C., & Serruys, P. W. J. C. (1991) · The American Journal of Cardiology · doi:10.1016/0002-9149(91)90008-9 · Cited by 47
Grassi, G., Morelli, V., Ceriotti, F., Polledri, E., Fustinoni, S., D’Agostino, S., Mantovani, G., Chiodini, I., & Arosio, M. (2020) · Hormones · doi:10.1007/s42000-020-00185-y · Cited by 46
Macias, N., Alemán-Mateo, H., Esparza-Romero, J., & Valencia, M. E. (2007) · Nutrition Journal · doi:10.1186/1475-2891-6-18 · Cited by 49
Haapala, I., Hirvonen, A., Niskanen, L., Uusitupa, M., Kröger, H., Alhava, E., & Nissinen, A. (2002) · Clinical Physiology and Functional Imaging · doi:10.1046/j.1475-097x.2002.00447.x · Cited by 46
Vanroy, C., Vissers, D., Cras, P., Beyne, S., Feys, H., Vanlandewijck, Y., & Truijen, S. (2014) · Disability and Rehabilitation · doi:10.3109/09638288.2013.859307 · Cited by 46
Stevenson, G. N., Collins, S. L., Ding, J., Impey, L., & Noble, J. A. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.07.021 · Cited by 46
Total body protein: a new cellular level mass and distribution prediction model
Wang, Z., Shen, W., Kotler, D. P., Heshka, S., Wielopolski, L., Aloia, J. F., Nelson, M. E., Pierson, R. N., & Heymsfield, S. B. (2003) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/78.5.979 · Cited by 46
Application of Ontologies for Assessing Collaborative Problem Solving Skills
Andrews-Todd, J., & Kerr, D. (2019) · International Journal of Testing · doi:10.1080/15305058.2019.1573823 · Cited by 46
Hogue, C. W. J., Rosenbloom, M., McCawley, C., & Lappas, D. G. (1994) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/1053-0770(94)90193-7 · Cited by 46
Żochowska, D., Bartłomiejczyk, I., Kamińska, A., Senatorski, G., & Pączek, L. (2006) · Transplantation Proceedings · doi:10.1016/j.transproceed.2005.12.008 · Cited by 46
Silva-Jaramillo, K. M., Neutzling, M. B., & Drehmer, M. (2015) · Public Health Nutrition · doi:10.1017/s1368980014003346 · Cited by 49
Andersen, L. B., Frederiksen‐Møller, B., Havelund, K. W., Dechend, R., Jørgensen, J. S., Jensen, B. L., Nielsen, J., Lykkedegn, S., Barington, T., & Christesen, H. T. (2014) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2014.11.008 · Cited by 53
Krönke, M., Eilers, C., Dimova, D., Köhler, M., Buschner, G., Schweiger, L., Konstantinidou, L., Makowski, M. R., Nagarajah, J., Navab, N., et al. (2022) · PLoS ONE · doi:10.1371/journal.pone.0268550 · Cited by 46
Transfer accuracy of 3D-printed trays for indirect bonding of orthodontic brackets:
Bachour, P. C., Klabunde, R., & Grünheid, T. (2022) · The Angle Orthodontist · doi:10.2319/073021-596.1 · Cited by 46
Comparison of marker-less and marker-based motion capture for baseball pitching kinematics
Fleisig, G. S., Slowik, J. S., Wassom, D., Yanagita, Y., Bishop, J., & Diffendaffer, A. Z. (2022) · Sports Biomechanics · doi:10.1080/14763141.2022.2076608 · Cited by 58
Potter, A. W., Nindl, L. J., Soto, L. D., Pazmino, A., Looney, D. P., Tharion, W. J., Robinson-Espinosa, J. A., & Friedl, K. E. (2022) · BMJ Nutrition Prevention & Health · doi:10.1136/bmjnph-2022-000512 · Cited by 60
Obstructive Sleep Apnea Detection Based on Sleep Sounds via Deep Learning
Wang, B., Tang, X., Ai, H., Li, Y., Xu, W., Wang, X., & Han, D. (2022) · Nature and Science of Sleep · doi:10.2147/nss.s373367 · Cited by 49
Hoelzemann, A., Romero, J., Bock, M., Laerhoven, K. V., & Lv, Q. (2023) · Sensors · doi:10.3390/s23135879 · Cited by 61
Varga‐Szemes, Á., Muscogiuri, G., Schoepf, U. J., Wichmann, J. L., Suranyi, P. S., Cecco, C. N. D., Cannaò, P. M., Renker, M., Mangold, S., Fox, M. A., et al. (2015) · European Radiology · doi:10.1007/s00330-015-3952-4 · Cited by 46
Magarelli, N., Milano, G., Baudi, P., Santagada, D. A., Righi, P., Spina, V., Leone, A., Amelia, R., Fabbriciani, C., & Bonomo, L. (2011) · La radiologia medica · doi:10.1007/s11547-011-0712-7 · Cited by 46
Bhargava, P., Lang, A., Al-Louzi, O., Carass, A., Prince, J., Calabresi, P. A., & Saidha, S. (2015) · Multiple Sclerosis International · doi:10.1155/2015/136295 · Cited by 45
Patient satisfaction with care in the intensive care unit: can we rely on proxies?
Stricker, K. H., Kimberger, O., BRUNNER, L., & Rothen, H. U. (2010) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2010.02293.x · Cited by 53
Validating chest MRI to detect and monitor cystic fibrosis lung disease in a pediatric cohort
Tepper, L. A., Ciet, P., Caudri, D., Quittner, A. L., Utens, E. M. W. J., & Tiddens, H. A. W. M. (2015) · Pediatric Pulmonology · doi:10.1002/ppul.23328 · Cited by 46
Bongers, C. C. W. G., Hopman, M. T. E., & Eijsvogels, T. M. H. (2015) · Journal of Visualized Experiments · doi:10.3791/53258 · Cited by 46
Cheung, J. P. Y., Bow, C., Samartzis, D., Ganal-Antonio, A. K. B., & Cheung, K. (2015) · The Spine Journal · doi:10.1016/j.spinee.2015.10.044 · Cited by 46
Evaluation of a community-based automated blood pressure measuring device.
Lewis, J. E., Boyle, E., Magharious, L., & Myers, M. G. (2002) · PubMed Central · Cited by 52
Repeatability and comparison of clinical techniques for anterior chamber angle assessment
Campbell, P., Redmond, T., Agarwal, R., Marshall, L. R., & Evans, B. J. W. (2015) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12200 · Cited by 50
Örtqvist, M., Moström, E. B., Roos, E. M., Lundell, P., Janarv, P., Werner, S., & Broström, E. W. (2011) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-011-1542-9 · Cited by 47
Dellamonica, J., Lerolle, N., Sargentini, C., Beduneau, G., Marco, F. D., Mercat, A., Richard, J.-C., Diehl, J., Mancebo, J., Rouby, J., et al. (2011) · Critical Care · doi:10.1186/cc10587 · Cited by 50
Ernst, M. J., Rast, F. M., Bauer, C. M., Marcar, V. L., & Kool, J. (2013) · BMC Research Notes · doi:10.1186/1756-0500-6-58 · Cited by 46
Stain, H. J., Payne, K., Thienel, R., Michie, P., Carr, V., & Kelly, B. (2011) · Journal of Telemedicine and Telecare · doi:10.1258/jtt.2011.101015 · Cited by 46
Hill, M. L., Cronkite, R. C., Ota, D., Yao, E. C., & Kiratli, B. J. (2009) · Journal of Telemedicine and Telecare · doi:10.1258/jtt.2009.081002 · Cited by 46
Validation of the SenseWear Pro3 Armband Using an Incremental Exercise Test
van Hoye, K., Mortelmans, P., & Lefevre, J. (2014) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e3182a1f836 · Cited by 40
3D Visual Activity Assessment Based on Natural Scene Statistics
Lee, K., Moorthy, A. K., Lee, S., & Bovik, A. C. (2014) · IEEE Transactions on Image Processing · doi:10.1109/tip.2013.2290592 · Cited by 47
High Agreement between Laboratory and Field Estimates of Critical Power in Cycling
Karsten, B., Jobson, S., Hopker, J., Jiménez, A., & Beedie, C. (2013) · International Journal of Sports Medicine · doi:10.1055/s-0033-1349844 · Cited by 46
Sinha, S., & Sinha, U. S. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22596 · Cited by 54
Lucet, J., Laouenan, C., Chelius, G., Véziris, N., Lepelletier, D., Friggeri, A., Abiteboul, D., Bouvet, É., Mentré, F., & Fleury, É. (2012) · PLoS ONE · doi:10.1371/journal.pone.0037893 · Cited by 50
Tele-ABR using a satellite connection in a mobile van for newborn hearing testing
Ramkumar, V., Hall, J. W., Nagarajan, R., Vanaja, C. S., & Kumaravelu, S. (2013) · Journal of Telemedicine and Telecare · doi:10.1177/1357633x13494691 · Cited by 46
Andersen, K. J., Knudsen, A. R., Kannerup, A.-S., Sasanuma, H., Nyengaard, J. R., Hamilton-Dutoit, S. J., Erlandsen, E. J., Jørgensen, B., & Mortensen, F. V. (2013) · International Journal of Surgery · doi:10.1016/j.ijsu.2013.07.009 · Cited by 53
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.