STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 11,201–11,300 of 47,868
Johnston, S. L., Pg, B., Harrison, J., Ritter, W., Joubert, J., & Holgate, S. (1992) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.1992.tb05649.x · Cited by 45
Hackett, L. P., Dusci, L. J., & Ilett, K. F. (1998) · Therapeutic Drug Monitoring · doi:10.1097/00007691-199802000-00006 · Cited by 45
Transgastric, pulsed doppler echocardiographic determination of cardiac output
Descorps-Declere, A., Smaïl, N., Vigué, B., Duranteau, J., Mimoz, O., Edouard, A., & Samii, K. (1996) · Intensive Care Medicine · doi:10.1007/bf01728328 · Cited by 45
Variability of Arterial Blood Gas Values Over Time in Stable Medical ICU Patients
Sasse, S. A., Chen, P. A., & Mahutte, C. K. (1994) · CHEST Journal · doi:10.1378/chest.106.1.187 · Cited by 45
Ry, S. D., Giannessi, D., & Clerico, A. (2001) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2001.070 · Cited by 45
Belmin, J., Visintin, J.-M., Salvatore, R., Sebban, C., & Moulias, R. (1995) · The American Journal of Medicine · doi:10.1016/s0002-9343(99)80079-5 · Cited by 45
Østergaard, M. (1997) · Rheumatology · doi:10.1093/rheumatology/36.11.1166 · Cited by 45
Kinnaird, T. D., Thompson, C., & Munt, B. I. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01294-3 · Cited by 45
Chard, D., McLean, M. A., Parker, G. J. M., MacManus, D. G., & Miller, D. H. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10043 · Cited by 45
Kühl, H. P., Hanrath, P., & Franke, A. (2003) · European Journal of Echocardiography · doi:10.1016/s1525-2167(03)00035-0 · Cited by 49
Peak expiratory flow and the resistance of the mini-wright peak flow meter
Pedersen, O., Rasmussen, T. R., Omland, Ø., Sigsgaard, T., Quanjer, P. H., & Miller, M. (1996) · European Respiratory Journal · doi:10.1183/09031936.96.09040828 · Cited by 46
Casati, A., Gallioli, G., Scandroglio, M., Passaretta, R., Borghi, B., & Torri, G. (2000) · European Journal of Anaesthesiology · doi:10.1046/j.1365-2346.2000.00731.x · Cited by 45
Lynnerup, N., Thomsen, J. L., & Frøhlich, B. (1998) · Forensic Science International · doi:10.1016/s0379-0738(97)00197-7 · Cited by 45
Walsh, T. S., Hopton, P., & Lee, A. (1998) · Critical Care Medicine · doi:10.1097/00003246-199807000-00020 · Cited by 45
Riley, M., Maehara, K., P�rsz�sz, J., ENGELEN, M. P. K. J., Tanaka, H., Wasserman, K., & Barstow, T. J. (1996) · European Journal of Applied Physiology · doi:10.1007/s004210050120 · Cited by 45
Measurements of leukotrienes in the urine: strategies and applications
Kumlin, M. (1997) · Allergy · doi:10.1111/j.1398-9995.1997.tb00966.x · Cited by 45
Therapeutic Drug Monitoring of Phenytoin Rationale and Current Status
Levine, M., & Chang, T. (1990) · Clinical Pharmacokinetics · doi:10.2165/00003088-199019050-00001 · Cited by 50
Arterial baroreflex sensitivity assessed from phase IV of the Valsalva maneuver
Kautzner, J., Hartikainen, J. E. K., Camm, A. J., & Malik, M. (1996) · The American Journal of Cardiology · doi:10.1016/s0002-9149(96)00370-0 · Cited by 45
Classification of asthma severity: should the international guidelines be changed?
Sawyer, Miles, Lewis, Fitzharris, Pearce, & Beasley (1998) · Clinical & Experimental Allergy · doi:10.1046/j.1365-2222.1998.00451.x · Cited by 47
Lung sound intensity in patients with emphysema and in normal subjects at standardised airflows.
Schreur, H. J. W., Sterk, P. J., Vanderschoot, J., van Klink, H. C., van Vollenhoven, E., & Dijkman, J. H. (1992) · Thorax · doi:10.1136/thx.47.9.674 · Cited by 45
Game, F. L., & Jones, A. F. (2001) · Diabetic Medicine · doi:10.1046/j.1464-5491.2001.00438.x · Cited by 49
A New Respiratory Monitor that Enables Accurate Measurement of Work of Breathing: A Validation Study
Blanch, P. B., & Banner, M. J. (1994) · Respiratory Care · doi:10.1177/194336549403900907 · Cited by 51
Mallouhi, A., Rieger, M., Czermak, B. V., Freund, M. C., Waldenberger, P., & Jaschke, W. R. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.180.1.1800233 · Cited by 45
Near‐patient testing devices to monitor oral anticoagulant therapy
Tripodi, A., Chantarangkul, V., & Mannucci, P. (2001) · British Journal of Haematology · doi:10.1046/j.1365-2141.2001.02753.x · Cited by 48
Validity of Bioelectrical Impedance Analysis to Estimation Fat-Free Mass in the Army Cadets
Langer, R., Borges, J., Pascoa, M., Cirolini, V., Guerra-Júnior, G., & Gonçalves, E. (2016) · Nutrients · doi:10.3390/nu8030121 · Cited by 44
Chang, Y., Xu, L., Han, F., Keenan, B. T., Kneeland-Szanto, E., Zhang, R., Zhang, W., Yu, Y., Zuo, Y., Pack, A. I., et al. (2019) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7720 · Cited by 44
Plaza-Florido, A., Alcantara, J. M. A., Migueles, J. H., Amaro-Gahete, F. J., Acosta, F. M., Mora-Gonzalez, J., Sacha, J., & Ortega, F. B. (2020) · Scientific Reports · doi:10.1038/s41598-020-68197-7 · Cited by 44
Langguth, B., & De Ridder, D. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12227117 · Cited by 44
Assessing the reliability of biologger techniques to measure activity in a free-ranging primate
McFarland, R., Hetem, R. S., Fuller, A., Mitchell, D., Henzi, S. P., & Barrett, L. (2013) · Animal Behaviour · doi:10.1016/j.anbehav.2013.02.005 · Cited by 49
Verhoeven, K. J. F., Verbon, E. H., van Gurp, T. P., Oplaat, C., de Carvalho, J. F., Morse, A. M., Stahl, M., Macel, M., & McIntyre, L. M. (2017) · New Phytologist · doi:10.1111/nph.14835 · Cited by 47
Bland–Altman plot: A brief overview
Kaur, P., & Stoltzfus, J. (2017) · International Journal of Academic Medicine · doi:10.4103/ijam.ijam_54_17 · Cited by 46
Li, B., Tai, D., Yan, K., Chen, Y., Chen, C., Huang, S.-F. K., Hsu, T.-H., Yu, W.-T., Xiao, J. Z., Lü, L., et al. (2022) · World Journal of Gastroenterology · doi:10.3748/wjg.v28.i22.2494 · Cited by 54
D’Oria, M., Bertoglio, L., Bignamini, A. A., Mani, K., Kölbel, T., Oderich, G. S., Chiesa, R., Lepidi, S., Abisi, S., Adam, D. J., et al. (2022) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2022.03.002 · Cited by 48
Werner, C., Hezel, N., Dongus, F., Spielmann, J., Mayer, J., Becker, C., & Bauer, J. M. (2023) · Scientific Reports · doi:10.1038/s41598-023-32550-3 · Cited by 57
Menychtas, D., Petrou, N., Kansizoglou, I., Γιαννακού, Ε., Gkrekidis, A., Gasteratos, A. C., Gourgoulis, V., Δούδα, Ε., Smilios, I., Michalopoulou, M., et al. (2023) · Frontiers in Rehabilitation Sciences · doi:10.3389/fresc.2023.1238134 · Cited by 59
Celis, N., Casallas, A., López-Barrera, E. A., Felician, M., Marchi, M. D., & Pappalardo, S. E. (2023) · ISPRS International Journal of Geo-Information · doi:10.3390/ijgi12100436 · Cited by 58
Sigmundsson, H., & Haga, M. (2024) · New Ideas in Psychology · doi:10.1016/j.newideapsych.2024.101111 · Cited by 61
Therapeutic drug monitoring of lamotrigine using capillary electrophoresis
Theurillat, R., Kühn, M., & Thormann, W. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)01257-8 · Cited by 44
Taylor, R. A., Oliva, I., Tonder, R. V., Elefteriades, J. A., Dziura, J. D., & Moore, C. L. (2012) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2011.01279.x · Cited by 44
Hollingsworth, K. G., Higgins, D. M., McCallum, M., Ward, L. J., Coombs, A., & Straub, V. W. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25072 · Cited by 44
Precision and accuracy of blood glucose measurements using three different instruments
Nowotny, B., Nowotny, P. J., Strassburger, K., & Roden, M. (2012) · Diabetic Medicine · doi:10.1111/j.1464-5491.2011.03406.x · Cited by 43
Klasen, E. M., Wills, B., Naithani, N., Gilman, R. H., Tielsch, J. M., Chiang, M., Khatry, S. K., Breysse, P. N., Menya, D., Apaka, C., et al. (2015) · Environmental Research · doi:10.1016/j.envres.2015.07.012 · Cited by 51
How well do adolescents determine portion sizes of foods and beverages?
Steyn, N. P., Senekal, M., Norris, S. A., Whati, L., MacKeown, J. M., & Nel, J. H. (2006) · PubMed · Cited by 44
Bouki, K. P., Sakkali, E., Toutouzas, K. P., Vlad, D., Barmperis, D., Phychari, S., Riga, M., Apostolou, T. S., & Stefanadis, C. (2015) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.25855 · Cited by 44
Rech, C. R., Dellagrana, R. A., Marucci, M. D. F. N., & Petróski, E. L. (2012) · Brazilian Journal of Kinanthropometry and Human Performance · doi:10.5007/1980-0037.2012v14n1p23 · Cited by 74
Hu, B., Lin, L.-Y., Zhuang, M., Yuan, Z., Li, S. Y., Yang, Y., Lü, M., Yu, S., Li, J., Ye, W. M., et al. (2015) · Public Health · doi:10.1016/j.puhe.2015.03.024 · Cited by 46
Are residents accurate in their assessments of their own surgical skills?
de Blacam, C., O’Keeffe, D., Nugent, E., Doherty, E. M., & Traynor, O. J. (2012) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2012.03.003 · Cited by 46
Reliability of indicators of sheep welfare assessed by a group observation method
Phythian, C. J., Cripps, P. J., Michalopoulou, E., Jones, P. H., Grove‐White, D., Clarkson, M. J., Winter, A. C., Stubbings, L. A., & Duncan, J. S. (2012) · The Veterinary Journal · doi:10.1016/j.tvjl.2011.12.006 · Cited by 50
Tracking Hypotension and Dynamic Changes in Arterial Blood Pressure with Brachial Cuff Measurements
Lakhal, K., Ehrmann, S., Runge, I., Legras, A., Dequin, P., Mercier, E., Wolff, M., Regnier, B., & Boulain, T. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181a8d83a · Cited by 45
Mandl, P., Supp, G. M., Baksa, G., Radner, H., Studenic, P., Gyebnar, J. N., Kurucz, R., Niedermayer, D. S., Aletaha, D., Balint, P. V., et al. (2014) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2014-205585 · Cited by 44
Hepatic perfusion in a tumor model using DCE-CT: an accuracy and precision study
Stewart, E. E., Chen, X., Hadway, J. A., & Lee, T. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/16/003 · Cited by 44
Janssen, I., & Sachlikidis, A. (2010) · Sports Biomechanics · doi:10.1080/14763141003690229 · Cited by 44
van Tiel, J., Bron, E. E., Tiderius, C. J., Bos, P. K., Reijman, M., Klein, S., Verhaar, J. A. N., Krestin, G. P., Weinans, H., Kotek, G., et al. (2012) · European Radiology · doi:10.1007/s00330-012-2616-x · Cited by 44
Ross, A. B. (2012) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf301332q · Cited by 46
Fukuo, W., Yoshiuchi, K., Ohashi, K., Togashi, H., Sekine, R., Kikuchi, H., Sakamoto, N., Inada, S., Sato, F., Kadowaki, T., et al. (2009) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2009.04.013 · Cited by 52
Subjective versus objective assessment of breast reconstruction
Henseler, H., Smith, J., BOWMAN, A. W., Khambay, B., Ju, X., Ayoub, A. F., & Ray, A. (2013) · Journal of Plastic Reconstructive & Aesthetic Surgery · doi:10.1016/j.bjps.2013.01.006 · Cited by 44
Development of a 1-concentration-4-step dosimeter protocol for methacholine testing
Merget, R., Jörres, R. A., Heinze, E., Haufs, M. G., Taeger, D., & Brüning, T. (2008) · Respiratory Medicine · doi:10.1016/j.rmed.2008.10.010 · Cited by 44
Farah, B. Q., Andrade-Lima, A., Cavalcante, B. R., de Oliveira, L. M. F. T., Brito, A. L. D. S., de Barros, M. V. G., & Ritti‐Dias, R. M. (2014) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12190 · Cited by 49
Do Cells Contribute to Tendon and Ligament Biomechanics?
Hammer, N., Huster, D., Fritsch, S., Hädrich, C., Koch, H., Schmidt, P., Sichting, F., Wägner, M., & Boldt, A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0105037 · Cited by 45
Arnalich‐Montiel, F., Muñoz-Negrete, F. J., Rebolleda, G., Sales‐Sanz, M., & Cabarga, C. (2006) · Eye · doi:10.1038/sj.eye.6702391 · Cited by 44
Noninvasive Assessment of Blood Pressure Variability in Preterm Infants
Andriessen, P., Schoffelen, R. L. M., Berendsen, R. C. M., de Beer, N. A. M., Oei, S. G., Wijn, P. F. F., & Blanco, C. E. (2003) · Pediatric Research · doi:10.1203/01.pdr.0000104152.85296.4f · Cited by 46
Doppler ultrasound assessment of posterior tibial artery size in humans
Sabatier, M. J., Stoner, L. R., Reifenberger, M., & McCully, K. K. (2006) · Journal of Clinical Ultrasound · doi:10.1002/jcu.20229 · Cited by 45
Arredondo, M., Garrido, C., Parkin, N. T., Zahonero, N., Bertagnolio, S., Soriano, V., & de Mendoza, C. (2011) · Journal of Clinical Microbiology · doi:10.1128/jcm.00418-11 · Cited by 44
Assessment of wheelchair driving performance in a virtual reality-based simulator
Mahajan, H., Dicianno, B. E., Cooper, R. A., & Ding, D. (2013) · Journal of Spinal Cord Medicine · doi:10.1179/2045772313y.0000000130 · Cited by 51
Determination of Water Content in Olive Oil by 31P NMR Spectroscopy
Hatzakis, E., & Dais, P. J. (2008) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf073227n · Cited by 44
Estimating the Weight of Children in Kenya: Do the Broselow Tape and Age-Based Formulas Measure Up?
House, D. R., Ngetich, E., Vreeman, R., & Rusyniak, D. E. (2012) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2012.07.110 · Cited by 45
Tidholm, A., Bodegård‐Westling, A., Höglund, K., Ljungvall, I., & Häggström, J. U. (2011) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.2011.00812.x · Cited by 44
Matias, D. S., Costa, R. F., Matias, B. S., Gordiano, L., & Correia, L. C. L. (2014) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.13313 · Cited by 45
Wilson, A. M. R., & Lewis, R. D. (2004) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2003.12.021 · Cited by 56
T2 Relaxometry of the Hippocampus at 3T
Bartlett, P. A., Symms, M. R., Free, S. L., & Duncan, J. S. (2007) · American Journal of Neuroradiology · doi:10.3174/ajnr.a0505 · Cited by 45
Johnston, H., Hilts, M., Beckham, W., & Berthelet, E. (2008) · Medical Physics · doi:10.1118/1.2924208 · Cited by 44
Hofman, M. S., Binns, D., Johnston, V. K., Siva, S., Thompson, M., Eu, P., Collins, M. L., & Hicks, R. J. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.114.147843 · Cited by 44
New Prognostic Markers for Outcome of Acute Pancreatitis: Overview of Reporting in 184 Studies
Sigounas, D., Tatsioni, A., Christodoulou, D. K., Tsianos, E. V., & Ioannidis, J. P. A. (2011) · Pancreas · doi:10.1097/mpa.0b013e31820bf8ac · Cited by 46
Gonçalves, H. M. D. S. L. M., Costa, A., Ayres‐de‐Campos, D., Santos, C., Rocha, A. P., & Bernardes, J. (2013) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-013-1036-7 · Cited by 52
Bamberg, C., Scheuermann, S., Fotopoulou, C., Slowinski, T., Dückelmann, A. M., Teichgräber, U. K.-M., Streitparth, F., Henrich, W., Dudenhausen, J. W., & Kalache, K. D. (2011) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2011.10.867 · Cited by 44
Jiang, J., Strother, C. M., Johnson, K. M., Baker, S., Consigny, D., Wieben, O. E., & Zagzebski, J. A. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/6/015 · Cited by 45
Fite, B. Z., Liu, Y., Kruse, D. E., Caskey, C. F., Walton, J. H., Lai, C.-Y., Mahakian, L. M., Larrat, B., Dumont, E., & Ferrara, K. W. (2012) · PLoS ONE · doi:10.1371/journal.pone.0035509 · Cited by 44
Naude, S., Lambrechts, N. E., Wagner, W. M., & Thompson, P. N. (2008) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.232.5.702 · Cited by 44
Calabro, M. A., Kim, Y., Franke, W. D., Stewart, J. M., & Welk, G. J. (2015) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2014.241 · Cited by 44
Reliability of HemoCue in patients with gastrointestinal bleeding
de Louw, A. V., Lasserre, N., Drouhin, F., Thierry, S., Lécuyer, L., Caen, D., & Tenaillon, A. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0461-6 · Cited by 44
Estimating Energy Expenditure With the RT3 Triaxial Accelerometer
Maddison, R., Jiang, Y., Hoorn, S. V., Mhurchú, C. N., Lawes, C. M. M., Rodgers, A., & Rush, E. C. (2009) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2009.10599559 · Cited by 49
López, F. U., Kopper, P. M. P., Cucco, C., Bona, Á. D., de Figueiredo, J. A. P., & Vier‐Pelisser, F. V. (2014) · Journal of Endodontics · doi:10.1016/j.joen.2014.09.003 · Cited by 44
Takahashi, K., Mackie, A. S., Thompson, R. B., Al-Naami, G. H., Inage, A., Rebeyka, I. M., Ross, D. B., Khoo, N. S., Colen, T., & Smallhorn, J. F. (2012) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2012.08.011 · Cited by 44
Sympathetic Activation in Congestive Heart Failure: Reproducibility of Neuroadrenergic Markers
Grassi, G. M., Bolla, G. B., Quarti‐Trevano, F., Arenare, F., Brambilla, G., & Mancia, G. (2008) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2008.09.013 · Cited by 47
Accuracy of Spring-levered and Piezo-electric Pedometers in Primary School Japanese Children
Nakae, S., Oshima, Y., & Ishii, K. (2008) · Journal of PHYSIOLOGICAL ANTHROPOLOGY · doi:10.2114/jpa2.27.233 · Cited by 56
Hollis, V., Holloway, J. A., Harris, S., Spencer, D. C., van Berkel, C., & Morgan, H. (2012) · PLoS ONE · doi:10.1371/journal.pone.0043702 · Cited by 46
der Zwaag, H. M. J. V. D. L.-V., Bos, J., van der Heide, H. J. L., & Nelissen, R. G. H. H. (2010) · International Orthopaedics · doi:10.1007/s00264-010-1082-9 · Cited by 45
Mapping anisotropy of the proximal femur for enhanced image based finite element analysis
Enns-Bray, W. S., Owoc, J. S., Nishiyama, K. K., & Boyd, S. K. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.08.020 · Cited by 52
Accuracy of Bladder Scanning in the Assessment of Postvoid Residual Volume
Al-Shaikh, G. K., Larochelle, A., Campbell, C., Schachter, J., Baker, K. R., & Pascali, D. (2009) · Journal of Obstetrics and Gynaecology Canada · doi:10.1016/s1701-2163(16)34215-3 · Cited by 51
Respiratory rate estimation during triage of children in hospitals
Shah, S. A., Fleming, S., Thompson, M., & Tarassenko, L. (2015) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2015.1105316 · Cited by 45
Mann, L. W., Higgins, D. M., Peters, C. N., Cassidy, S., Hodson, K. K., Coombs, A., Taylor, R., & Hollingsworth, K. G. (2016) · Radiology · doi:10.1148/radiol.2015150320 · Cited by 44
Mora, C., Marcus, C. D., Barbe, C., Ecarnot, F., & Long, A. (2013) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2013.10.013 · Cited by 44
Minimally- and non-invasive assessment of maternal cardiac output: go with the flow!
Armstrong, S. L., Fernando, R., & Columb, M. O. (2011) · International Journal of Obstetric Anesthesia · doi:10.1016/j.ijoa.2011.07.006 · Cited by 44
Tamhane, A. R., Redden, D. T., McGwin, G., Brown, E. E., Westfall, A. O., Reynolds, R. J., Hughes, L. B., Conn, D. L., Callahan, L. F., Jonas, B., et al. (2013) · The Journal of Rheumatology · doi:10.3899/jrheum.121225 · Cited by 54
Griffiths, M. J., Lemon, J., Rayamajhi, A., Poudel, P., Shrestha, P., Srivastav, V., Kneen, R., Medina‐Lara, A., Singh, R. R., & Solomon, T. (2013) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0002383 · Cited by 46
Overview of Agreement Statistics for Medical Devices
Lin, L. (2007) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543400701668290 · Cited by 49
Silva, M. I. B., Vale, B. S., Lemos, C. C. S., Klein, M. R. S. T., & Bregman, R. (2013) · Obesity · doi:10.1002/oby.20261 · Cited by 55
Multiple Sclerosis: Cerebral Circulation Time
Mancini, M., Morra, V. B., Donato, O. D., Maglio, V., Lanzillo, R., Liuzzi, R., Salvatore, E., Brunetti, A., Iaccarino, V., & Salvatore, M. (2012) · Radiology · doi:10.1148/radiol.11111239 · Cited by 44
Haroon, H. A., Morris, D. M., Embleton, K. V., Alexander, D. C., & Parker, G. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2006528 · Cited by 44
Clark, B., Pavey, T., Lim, R. F., Gomersall, S. R., & Brown, W. J. (2015) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2015.02.001 · Cited by 50
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.