STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 10,901–11,000 of 47,868
Svantesson, U., Zander, M., Klingberg, S., & Slinde, F. (2008) · Journal of Negative Results in BioMedicine · doi:10.1186/1477-5751-7-1 · Cited by 45
Are the measurements of water-filled and air-charged catheters the same in urodynamics?
Digesu, G. A., Derpapas, A., Robshaw, P., Vijaya, G., Hendricken, C., & Khullar, V. (2013) · International Urogynecology Journal · doi:10.1007/s00192-013-2182-z · Cited by 49
Refractive Stabilization and Corneal Swelling After Cataract Surgery
de Juan, V., Herreras, J. M., Pérez, I., Morejón, Á., Cristóbal, A. D. R. S., Martín, R., Fernández, I., & Rodríguez, G. (2012) · Optometry and Vision Science · doi:10.1097/opx.0b013e318278fc44 · Cited by 46
Schulze, M. B., Kroke, A., Saracci, R., & Boeing, H. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200204000-00002 · Cited by 47
de Sanctis, U., Machetta, F., L., R., Dalmasso, P., & Grignolo, F. M. (2006) · Cornea · doi:10.1097/01.ico.0000214217.83119.af · Cited by 46
Bruining, N., Tanimoto, S., Otsuka, M., Weustink, A. C., Ligthart, J. M. R., de Winter, S., van Mieghem, C. A. G., Nieman, K., de Feyter, P. J., van Domburg, R., et al. (2008) · EuroIntervention · doi:10.4244/eijv4i2a49 · Cited by 46
Tanabe, M., Lamia, B., Tanaka, H., SCHWARTZMAN, D. S., Pinsky, M. R., & Gorcsan, J. (2008) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.09.012 · Cited by 46
Malisova, O., Bountziouka, V., Panagiotakos, D. B., Zampelas, A., & Kapsokefalou, M. (2011) · International Journal of Food Sciences and Nutrition · doi:10.3109/09637486.2011.607799 · Cited by 53
Weese‐Mayer, D. E., Corwin, M. J., Peucker, M., Fiore, J. M. D., Hufford, D. R., Tinsley, L. R., Neuman, M. R., Martin, R. J., Brooks, L. J., Ward, S. L. D., et al. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.2.9904029 · Cited by 46
Peripheral Nerve Motion Measurement with Spectral Doppler Sonography: A Reliability Study
Hough, A. D., Moore, A. P., & JONES, M. P. (2000) · Journal of Hand Surgery (European Volume) · doi:10.1054/jhsb.2000.0453 · Cited by 46
Ginde, A. A., Cagliero, E., Nathan, D. M., & Camargo, C. A. (2008) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2008.00240.x · Cited by 52
Henseler, H., Khambay, B., BOWMAN, A. W., Smith, J., Siebert, J. P., Oehler, S., Ju, X., Ayoub, A. F., & Ray, A. (2010) · Journal of Plastic Reconstructive & Aesthetic Surgery · doi:10.1016/j.bjps.2010.08.044 · Cited by 46
Intra-rater reliability in measuring range of motion in infants with congenital muscular torticollis
Klackenberg, E. B. P., Elfving, B., Haglund‐Åkerlind, Y., & Carlberg, E. B. (2005) · Advances in Physiotherapy · doi:10.1080/14038190510010331 · Cited by 46
Campino, C., Carvajal, C. A., Cornejo, J., Martín, B. S., Olivieri, O., Guidi, G. C., Faccini, G., Pasini, F., Sateler, J., Baudrand, R., et al. (2009) · Endocrine · doi:10.1007/s12020-009-9269-9 · Cited by 48
Leukotriene E4 in urine in patients with asthma and COPD—The effect of smoking habit
Gaki, Ε., Papatheodorou, G. N., Ischaki, E., Grammenou, V., Papa, I., & Loukides, S. (2006) · Respiratory Medicine · doi:10.1016/j.rmed.2006.06.031 · Cited by 46
Maguire, A., Biesheuvel, C. J., Ambler, G. R., Moore, B., McLean, M. P., & Cowell, C. T. C. T. (2007) · Clinical Endocrinology · doi:10.1111/j.1365-2265.2007.03100.x · Cited by 53
Minetto, M. A., Gazzoni, M., Lanfranco, F., Baldi, M., Saba, L., Pedrola, R., Komi, P. V., & Rainoldi, A. (2007) · European Journal of Applied Physiology · doi:10.1007/s00421-007-0484-x · Cited by 52
López‐Miguel, A., Martínez-Almeída, L., González-García, M. J., Coco-Martín, M. B., Sobrado‐Calvo, P., & Maldonado, M. J. (2012) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2012.08.061 · Cited by 46
Does Elbow Position Affect Strength and Reproducibility of Power Grip Measurements?
Ng, G. Y. F., & Fan, A. C. (2001) · Physiotherapy · doi:10.1016/s0031-9406(05)60443-9 · Cited by 46
Estimation of stature by measuring fibula and ulna bone length in 2443 older adults
Auyeung, T. W., Lee, J. S. W., Kwok, T. C. Y., Leung, J., Leung, P. C., & Woo, J. (2009) · The journal of nutrition health & aging · doi:10.1007/s12603-009-0254-z · Cited by 46
Accuracy of ultrasonographic measurement of infrarenal abdominal aortic aneurysm
Akkersdijk, G. J. M., Puylaert, J. B. C. M., Coerkamp, E. G., & de Vries, A. C. (1994) · British journal of surgery · doi:10.1002/bjs.1800810317 · Cited by 46
Evaluation of the ICare Rebound Tonometer as a Home Intraocular Pressure Monitoring Device
Asrani, S., Chatterjee, A., Wallace, D. K., Santiago-Turla, C., & Stinnett, S. S. (2010) · Journal of Glaucoma · doi:10.1097/ijg.0b013e3181d78811 · Cited by 46
A Meta‐analysis of Published Studies Concerning the Validity of Thoracic Impedance Cardiography
Raaijmakers, E., Faes, T. J. C., Scholten, R. J. P. M., Goovaerts, H. G., & Heethaar, R. M. (1999) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1999.tb09458.x · Cited by 46
Chapple, I., Matthews, J. B., Thorpe, G. H. G., Glenwright, H. D., Smith, J. M., & Saxby, M. S. (1993) · Journal of Periodontal Research · doi:10.1111/j.1600-0765.1993.tb02093.x · Cited by 46
Clinical Assessment, Optic Disk Measurements, and Visual-Evoked Potential in Optic Nerve Hypoplasia
Borchert, M., McCulloch, D. L., ROTHER, C., & Stout, A. U. (1995) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)72207-x · Cited by 46
Gillen, L. J., Tapsell, L. C., Patch, C. S., Owen, A. J., & Batterham, M. J. (2005) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2005.04.007 · Cited by 53
The X-ray measurement of hallux valgus: an inter- and intra-observer error study
Kilmartin, T. E., Barrington, R., & Wallace, W. A. (1992) · The Foot · doi:10.1016/0958-2592(92)90034-m · Cited by 46
Boos, C. J., Soor, S. K., Kang, D., & Lip, G. Y. H. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm070 · Cited by 47
Comparing the Nidek MP‐1 and Humphrey Field Analyzer in Normal Subjects
Acton, J. H., Bartlett, N. S., & Greenstein, V. C. (2011) · Optometry and Vision Science · doi:10.1097/opx.0b013e31822b3746 · Cited by 46
Altunkan, Ş., Ilman, N., & Altunkan, E. (2008) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3282f3fb50 · Cited by 46
Fredericson, M., Lee, S.-U., Welsh, J., Butts, K., Norbash, A., & Carragee, E. J. (2001) · The Spine Journal · doi:10.1016/s1529-9430(01)00014-6 · Cited by 46
Bertolotto, M., Pozzato, G., Crocè, L. S., Nascimben, F., Gasparini, C., Cova, M. A., & Tiribelli, C. (2005) · Investigative Radiology · doi:10.1097/01.rli.0000188363.93670.45 · Cited by 47
Collins, C. E., Burrows, T. L., Truby, H., Morgan, P. J., Wright, I. M. R., Davies, P. S. W., & Callister, R. (2013) · Journal of the Academy of Nutrition and Dietetics · doi:10.1016/j.jand.2012.09.021 · Cited by 53
Acute hypoxia impairs dynamic cerebral autoregulation: results from two independent techniques
Subudhi, A. W., Panerai, R. B., & Roach, R. C. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00498.2009 · Cited by 46
The Power-Velocity Integral at the Vena Contracta
Buck, T., Mucci, R. A., Guerrero, J., Holmvang, G., Handschumacher, M. D., & Levine, R. A. (2000) · Circulation · doi:10.1161/01.cir.102.9.1053 · Cited by 46
Exercise tolerance in children with cystic fibrosis undergoing lung transplantation assessment
Aurora, P., Prasad, S. A., Balfour-Lynn, I. M., Slade, G., Whitehead, B., & Dinwiddie, R. (2001) · European Respiratory Journal · doi:10.1183/09031936.01.00058701 · Cited by 47
Changes in natural head position observed immediately and one year after rapid maxillary expansion
McGuinness, N. J. P., & McDonald, J. P. (2005) · European Journal of Orthodontics · doi:10.1093/ejo/cji064 · Cited by 46
Swamy, G., Ling, Q., Li, T., & Mukkamala, R. (2007) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01159.2006 · Cited by 50
Wrigge, H., Sydow, M., Zinserling, J., Neumann, P., Hinz, J., & Burchardi, H. (1998) · Intensive Care Medicine · doi:10.1007/s001340050601 · Cited by 46
Defining episodes of diarrhoea: results from a three-country study in Sub-Saharan Africa.
Wright, J., Gundry, S., Conroy, R. M., Wood, D., du Preez, M., Ferro-Luzzi, A., Genthe, B., Kirimi, M., Moyo, S., Mutisi, C., et al. (2006) · PubMed · Cited by 49
Aortic Pulsatile Distention in Young Healthy Volunteers is Asymmetric: Analysis with ECG-gated MRI
van Prehn, J., Vincken, K. L., Sprinkhuizen, S. M., Viergever, M. A., van Keulen, J. W., van Herwaarden, J. A., Moll, F. L., & Bartels, L. W. (2008) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2008.11.007 · Cited by 46
Weber, U., Hodler, J., Jurik, A. G., Pfirrmann, C. W. A., Rufibach, K., Kissling, R. O., Khan, M. A., Lambert, R. G. W., & Maksymowych, W. P. (2009) · Annals of the Rheumatic Diseases · doi:10.1136/ard.2009.108274 · Cited by 50
CT Measurement of Anteversion in the Femoral Neck
Hermann, K. L., & Egund, N. (1997) · Acta Radiologica · doi:10.1080/02841859709174381 · Cited by 46
A Hierarchical Outcomes Approach to Test Assessment
Pearl, W. S. (1999) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(99)70421-x · Cited by 46
A Preliminary Evaluation of the Mean Arterial Pressure as Measured by Cuff Oscillometry
Smulyan, H., Sheehe, P. R., & Safar, M. E. (2008) · American Journal of Hypertension · doi:10.1038/ajh.2007.45 · Cited by 49
Agreement between physiotherapists on quality of movement rated via videotape
Pomeroy, V. M., Pramanik, A., Sykes, L., Richards, J., & Hill, E. (2003) · Clinical Rehabilitation · doi:10.1191/0269215503cr607oa · Cited by 44
Ghani, K. R., Pilcher, J., Rowland, D., Patel, U., Nassiri, D., & Anson, K. M. (2008) · Urology · doi:10.1016/j.urology.2008.02.033 · Cited by 46
Measurement of Cerebral Oxidative Metabolism with Near-Infrared Spectroscopy: A Validation Study
Tichauer, K. M., Hadway, J. A., Lee, T., & Lawrence, K. S. (2005) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600230 · Cited by 53
A new FFQ designed to measure the intake of fatty acids and antioxidants in children
Stiegler, P., Sausenthaler, S., Buyken, A. E., Rzehak, P., Czech, D., Linseisen, J., Kroke, A., Gedrich, K., Robertson, C. E., & Heinrich, J. (2009) · Public Health Nutrition · doi:10.1017/s1368980009005813 · Cited by 50
Tseng, L. W., Hughes, D., & Giger, U. (2001) · American Journal of Veterinary Research · doi:10.2460/ajvr.2001.62.1455 · Cited by 46
Schaefer, A., MEYER, G., Hilfiker‐Kleiner, D., BRAND, B., Drexler, H., & KLEIN, G. (2005) · European Journal of Echocardiography · doi:10.1016/j.euje.2005.01.007 · Cited by 49
Hoftman, N. N., Braunfeld, M. Y. C., Hoftman, G. D., & Mahajan, A. (2006) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2005.09.031 · Cited by 46
Uwaifo, G. I., Parikh, S. J., Keil, M. F., Elberg, J., Chin, J., & Yanovski, J. A. (2002) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.87.6.8578 · Cited by 54
Mainstream end-tidal carbon dioxide monitoring in ventilated neonates.
Ramesh Bhat, Y., & Abhishek, N. (2008) · PubMed · Cited by 46
Obstructive Sleep Apnea in Obese Hospitalized Patients: A Single Center Experience
Sharma, S., Mather, P. J., Efird, J. T., Kahn, D., Shiue, K. Y., Cheema, M., Malloy, R., & Quan, S. F. (2015) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.4842 · Cited by 50
The Validity and Reliability of Noninvasive Methods for Measuring Kyphosis
Azadinia, F., Kamyab, M., Behtash, H., Ganjavian, M. S., & Javaheri, M. M. (2013) · Journal of Spinal Disorders & Techniques · doi:10.1097/bsd.0b013e31829a3574 · Cited by 46
Alves, R. C., Félix, S., Rodríguez-Archilla, A., Oliveira, P., Brito, J., & dos Santos, J. M. (2015) · PubMed Central · Cited by 46
Three-dimensional surface scanners compared with standard anthropometric measurements for head shape
Beaumont, C. A. A., Knoops, P. G. M., Borghi, A., Jeelani, O., Koudstaal, M. J., Schievano, S., Dunaway, D., & Rodríguez-Flórez, N. (2017) · Journal of Cranio-Maxillofacial Surgery · doi:10.1016/j.jcms.2017.03.003 · Cited by 51
Measuring Resolution in the Contrast Domain
Rabin, J. C., & WICKS, J. (1996) · Optometry and Vision Science · doi:10.1002/j.1538-9235.1996.tb04493.x · Cited by 46
Evaluation of Petri dish sampling for assessment of cat allergen in airborne dust
Karlsson, A.-S., Hedrén, M., Almqvist, C., Larsson, K., & Renström, A. (2002) · Allergy · doi:10.1034/j.1398-9995.2002.1s3297.x · Cited by 46
Diagnosis of allergic bronchopulmonary aspergillosis (ABPA) in cystic fibrosis
Skov, M., Koch, C., Reimert, C. M., & Poulsen, L. K. (2000) · Allergy · doi:10.1034/j.1398-9995.2000.00342.x · Cited by 46
Statistical strategies to assess reliability in ophthalmology
Patton, N., Aslam, T. M., & Murray, G. D. (2005) · Eye · doi:10.1038/sj.eye.6702097 · Cited by 50
Karwatowski, S. P., Brecker, S. J., Yang, G. Z., Firmin, D. N., Sutton, M. S. J., & Underwood, S. R. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050116 · Cited by 46
Stake, G., & Monclair, T. F. (1991) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365519109091624 · Cited by 46
Evaluation of Differences Between Fan-Beam and Pencil-Beam Densitometers
Mazess, R. B., & Barden, H. S. (2000) · Calcified Tissue International · doi:10.1007/s002230001147 · Cited by 48
Regional myocardial velocity imaged by magnetic resonance in patients with ischaemic heart disease.
Karwatowski, S. P., Mohiaddin, R. H., Yang, G. Z., Firmin, D. N., Sutton, M. S. J., & Underwood, S. R. (1994) · Heart · doi:10.1136/hrt.72.4.332 · Cited by 46
Quantification of Cough-Related Urine Loss Using the Paper Towel Test
Miller, J. M., ASHTON-MILLER, J. A., & DELANCEY, J. O. L. (1998) · Obstetrics and Gynecology · doi:10.1016/s0029-7844(98)00045-3 · Cited by 46
Epstein, E., & Valentin, L. (2002) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.2002.00841.x · Cited by 46
Wijsman, J. H., van Dierendonck, J., Keijzer, R., van de Velde, C. J. �., & Cornelisse, C. J. (1992) · The Journal of Pathology · doi:10.1002/path.1711680113 · Cited by 46
Schoder, M., Cartes-Zumelzu, F., Grabenwöger, M., Cejna, M., Funovics, M. A., Krenn, C. G., Hutschala, D., Wolf, F., Thurnher, S. A., Kretschmer, G., et al. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.180.3.1800709 · Cited by 46
Acoustic Method to Estimate the Longitudinal Area Profile of Endotracheal Tubes
Surell, C. V., Louis, B., Lofaso, F., Beydon, L., Brochard, L. J., HARF, A., Fredberg, J. J., & Isabey, D. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.149.1.8111593 · Cited by 46
Echo doppler assessment of left ventricular function in rats with hypertensive hypertrophy
Ono, K., Masuyama, T., Yamamoto, K., Doi, R., Sakata, Y., Nishikawa, N., Mano, T., Kuzuya, T., Takeda, H., & Hori, M. (2002) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2002.115034 · Cited by 46
A Novel Nonobstructive Intravascular MRI Coil
Worthley, S. G., Helft, G., Fuster, V., Fayad, Z. A., Shinnar, M., Minkoff, L. A., Schechter, C. B., Fallon, J. T., & Badimón, J. J. (2003) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/01.atv.0000053183.08854.a4 · Cited by 46
Auleley, G.-R., Rousselin, B., Ayral, X., Edouard-Noël, R., Dougados, M., & Ravaud, P. (1998) · Annals of the Rheumatic Diseases · doi:10.1136/ard.57.9.519 · Cited by 46
Natural logarithmic estimates of Kt/V in the pediatric hemodialysis population
Goldstein, S. L., Sorof, J. M., & Brewer, E. D. (1999) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(99)70189-7 · Cited by 46
Suematsu, Y., Takamoto, S., Kaneko, Y., Ohtsuka, T., Takayama, H., Kotsuka, Y., & Murakami, A. (2003) · Circulation · doi:10.1161/01.cir.0000047210.07839.7b · Cited by 46
Franz, M. R., Kirchhof, P. F., Fabritz, L., & Zabel, M. (1995) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1995.tb06988.x · Cited by 46
Anal sensation and the continence mechanism
Miller, R. C., Bartolo, D. C. C., Roe, A. M., Cerveró, F., & Mortensen, N. (1988) · Diseases of the Colon & Rectum · doi:10.1007/bf02552612 · Cited by 46
Functional imaging of the retina using the multifocal electroretinograph: a control study.
Parks, S., Keating, D., Williamson, T. H., Evans, A., Elliott, A. T., & Jay, J. L. (1996) · British Journal of Ophthalmology · doi:10.1136/bjo.80.9.831 · Cited by 54
Lum, D., & Coel, M. (2003) · Nuclear Medicine Communications · doi:10.1097/00006231-200303000-00005 · Cited by 46
Ratcliffe, M. B., Wallace, A. W., Salahieh, A., Hong, J., Ruch, S., & Hall, T. S. (2000) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(00)70225-x · Cited by 47
Comparison of Three Different Plasma Homocysteine Assays with Gas Chromatography–Mass Spectrometry
Ubbink, J., Delport, R., Riezler, R., & Vermaak, W. J. H. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.5.670 · Cited by 46
Quantification of Serum Proteins Using Capillary Electrophoresis
Jenkins, M. A., & Guerin, M. D. (1995) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456329503200510 · Cited by 46
Marks, G. B., Tovey, E. R., Peat, J. K., Salome, C. M., & Woolcock, A. J. (1995) · Clinical & Experimental Allergy · doi:10.1111/j.1365-2222.1995.tb03043.x · Cited by 47
In vitro validation of right ventricular volume measurement by three dimensional echocardiography.
Vogel, M., White, P. A., & Redington, A. N. (1995) · Heart · doi:10.1136/hrt.74.4.460 · Cited by 46
Ward, J. I., Greenberg, D. P., Anderson, P. W., Burkart, K., Christenson, P. D., Gordon, L., Käyhty, H. M., Kuo, J. S., & Vella, P. P. (1988) · Journal of Clinical Microbiology · doi:10.1128/jcm.26.1.72-78.1988 · Cited by 50
Hermans, W. R. M., Rensing, B. J. W. M., Strauss, B. H., & Serruys, P. W. J. C. (1992) · Catheterization and Cardiovascular Diagnosis · doi:10.1002/ccd.1810250303 · Cited by 46
Chenzbraun, A., Pinto, F. J., Popylisen, S., Schnittger, I., & Popp, R. L. (1993) · Heart · doi:10.1136/hrt.70.5.448 · Cited by 46
Munyewende, P. O., Levin, J., & Rispel, L. C. (2016) · Global Health Action · doi:10.3402/gha.v9.32486 · Cited by 46
Dittmar, M., & Reber, H. (2001) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.2001.281.5.e1005 · Cited by 45
Cheong, K. B., Leung, K. Y., Li, T. K. T., Chan, H. Y., Lee, Y. P., & Tang, M. H. Y. (2010) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.7609 · Cited by 45
Yao, L., Jayasinghe, R. G., Lee, B. H., Bhasin, S. S., Pilcher, W., Doxie, D. B., Gonzalez-Kozlova, E., Dasari, S., Fiala, M. A., Pita-Juarez, Y., et al. (2022) · Cancer Research Communications · doi:10.1158/2767-9764.crc-22-0022 · Cited by 45
Reproducibility and validity of a semi-quantitative FFQ for trace elements
Lee, Y., & Park, K. (2016) · British Journal Of Nutrition · doi:10.1017/s0007114516002622 · Cited by 45
Zhao, D., Sun, Y., Wan, S., & Feng, W. (2016) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.12.005 · Cited by 52
Worsfold, S., Mahon, M., Pimperton, H., Stevenson, J., & Kennedy, C. (2018) · Research in Developmental Disabilities · doi:10.1016/j.ridd.2018.04.007 · Cited by 48
Truntzer, J. N., Hoppe, D. J., Shapiro, L. M., & Safran, M. R. (2019) · The American Journal of Sports Medicine · doi:10.1177/0363546519876105 · Cited by 46
Crotti, M., Foweather, L., Rudd, J. R., Hurter, L., Schwarz, S., & Boddy, L. M. (2020) · Journal of Sports Sciences · doi:10.1080/02640414.2020.1740469 · Cited by 55
Reliability of pressure pain threshold to discriminate individuals with neck and low back pain
Zicarelli, C. A. M., Santos, J. P. M., Poli‐Frederico, R. C., da Silva, R. A., Barillec, F., Barrette, G., Iida, L. M., Russo, P. P., Larangeira, L. L. S., Fernandes, M. T. P., et al. (2021) · Journal of Back and Musculoskeletal Rehabilitation · doi:10.3233/bmr-181208 · Cited by 51
Hosoi, Y., Kamimoto, T., Sakai, K., Yamada, M., & Kawakami, M. (2023) · Frontiers in Neurology · doi:10.3389/fneur.2023.1219505 · Cited by 49
Berhail, S., & Katipoğlu, O. M. (2023) · Theoretical and Applied Climatology · doi:10.1007/s00704-023-04601-2 · Cited by 48
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.