CoChat

Working accuracy of pulse oximetry in COVID-19 patients stepping down from intensive care: a clinical evaluation

Open access
Philip, Keir Elmslie James, Bennett, Benjamin, Fuller, Silas, Lonergan, Bradley, McFadyen, Charles, Burns, Janis, Tidswell, Robert, Vlachou, Aikaterini · 2020 · BMJ Open Respiratory Research
Cited by 36

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Introduction: UK guidelines suggest that pulse oximetry, rather than blood gas sampling, is adequate for monitoring of patients with COVID-19 if CO 2 retention is not suspected. However, pulse oximetry has impaired accuracy in certain patient groups, and data are lacking on its accuracy in patients with COVID-19 stepping down from intensive care unit (ICU) to non-ICU settings or being transferred to another ICU. Methods: We assessed the bias, precision and limits of agreement using 90 paired SpO 2 and SaO 2 from 30 patients (3 paired samples per patient). To assess the agreement between pulse oximetry (SpO 2) and arterial blood gas analysis (SaO 2) in patients with COVID-19, deemed clinically stable to step down from an ICU to a non-ICU ward, or be transferred to another ICU. This was done to evaluate whether the guidelines were appropriate for our setting. Results: Mean difference between SaO 2 and SpO 2 (bias) was 0.4%, with an SD of 2.4 (precision). The limits of agreement between SpO 2 and SaO 2 were as follows: upper limit of 5.2% (95% CI 6.5% to 4.2%) and lower limit of −4.3% (95% CI −3.4% to −5.7%). Conclusions: In our setting, pulse oximetry showed a level of agreement with SaO 2 measurement that was slightly suboptimal, although within acceptable levels for Food and Drug Authority approval, in people with COVID-19 judged clinically ready to step down from ICU to a non-ICU ward, or who were being transferred to another hospital’s ICU. In such patients, SpO 2 should be interpreted with caution. Arterial blood gas assessment of SaO 2 may still be clinically indicated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmjresp-2020-000778

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 36

Metadata

Authors
Philip, K. E. J., Bennett, B., Fuller, S., Lonergan, B., McFadyen, C., Burns, J., Tidswell, R., & Vlachou, A.
Venue
BMJ Open Respiratory Research
Publisher
BMJ
Published
2020-12
Volume
7
Issue
1
Pages
e000778
ISSN
2052-4439 (ISSN-L)
OpenAlex
W3113606112
Cited by
36
References
4
FWCI
1.99
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Working accuracy of pulse oximetry in COVID-19 patients stepping down from intensive care: a clinical evaluation. https://app.cochat.ai/papers/10.1136/bmjresp-2020-000778
The paper
Philip, K. E. J., Bennett, B., Fuller, S., Lonergan, B., McFadyen, C., Burns, J., Tidswell, R., & Vlachou, A. (2020). Working accuracy of pulse oximetry in COVID-19 patients stepping down from intensive care: a clinical evaluation. BMJ Open Respiratory Research. https://doi.org/10.1136/bmjresp-2020-000778

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.