Validation of the Fitbit One® for physical activity measurement at an upper torso attachment site

Open access
Diaz, Keith M., Krupka, David J., Chang, Melinda J., Shaffer, Jonathan A., Ma, Yao, Goldsmith, Jeff, Schwartz, Joseph E., Davidson, Karina W.·2016·BMC Research Notes

Abstract

BACKGROUND: The upper torso is recommended as an attachment site for the Fitbit One(®), one of the most common wireless physical activity trackers in the consumer market, and could represent a viable alternative to wrist- and hip-attachment sites. The objective of this study was to provide evidence concerning the validity of the Fitbit One(®) attached to the upper torso for measuring step counts and energy expenditure among female adults. RESULTS: Thirteen female adults completed a four-phase treadmill exercise protocol (1.9, 3.0, 4.0, and 5.2 mph). Participants were fitted with three Fitbit(®) trackers (two Fitbit One(®) trackers: one on the upper torso, one on the hip; and a wrist-based Fitbit Flex(®)). Steps were assessed by manual counting of a video recording. Energy expenditure was measured by gas exchange indirect calorimetry. Concordance correlation coefficients of Fitbit-estimated step counts to observed step counts for the upper torso-attached Fitbit One(®), hip-attached Fitbit One(®) and wrist-attached Fitbit Flex(®) were 0.98 (95% CI 0.97-0.99), 0.99 (95% CI 0.99-0.99), and 0.75 (95% CI 0.70-0.79), respectively. The percent error for step count estimates from the upper torso attachment site was ≤3% for all walking and running speeds. Upper torso step count estimates showed similar accuracy relative to hip attachment of the Fitbit One(®) and were more accurate than the wrist-based Fitbit Flex(®). Similar results were obtained for energy expenditure estimates. Energy expenditure estimates for the upper torso attachment site yielded relative percent errors that ranged from 9 to 19% and were more accurate than the wrist-based Fitbit Flex(®), but less accurate than hip attachment of the Fitbit One(®). CONCLUSIONS: Our study shows that physical activity measures obtained from the upper torso attachment site of the Fitbit One(®) are accurate across different walking and running speeds in female adults. The upper torso attachment site of the Fitbit One(®) outperformed the wrist-based Fitbit Flex(®) and yielded similar step count estimates to hip-attachment. These data support the upper torso as an alternative attachment site for the Fitbit One(®).

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s13104-016-2020-8

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. [20]Lazar A Koehler C Tanenbaum J Why We Use and Abandon Smart Devices ACM Int Jt Conf Pervasive Ubiquitous Comput 2015

Cited by

Sorted by citations

Authors
Diaz, K. M., Krupka, D. J., Chang, M. J., Shaffer, J. A., Ma, Y., Goldsmith, J., Schwartz, J. E., & Davidson, K. W.
Affiliations
  • Columbia University Irving Medical Center (US)
  • University of Colorado Denver (US)
  • Columbia University (US)
Corresponding author
Diaz, Keith M.
Venue
BMC Research Notes
Published
2016-04-12
Volume
9
Issue
1
Pages
213-213
ISSN
1756-0500 (ISSN-L)
OpenAlex
W2341847801
Cited by
29
References
24
Citations by year
2025: 1 · 2024: 1 · 2022: 1 · 2021: 2 · 2020: 7 · 2019: 3 · 2018: 8 · 2017: 6
FWCI
4.56
Type
journal article
Language
en
Open access
Locations
  • BMC Research Notes (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Funders
National Heart, Lung, and Blood Institute (R01-HL116470-02S1, R01-HL115941)
Topics
  • Health Sciences › Medicine › Physiology › Physical Activity and Health
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
Keywords
wearable activity trackers, step count accuracy, energy expenditure estimation, treadmill exercise, adult women, device validation
MeSH terms
Adult, Calorimetry, Indirect, Energy Metabolism, Exercise Test, Female, Humans, Middle Aged, Running, Reproducibility of Results, Exercise, Walking, Monitoring, Ambulatory, Young Adult, Torso, Accelerometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review