STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 20,401–20,500 of 47,868
A Comparative Analysis of Pedometry in Measuring Physical Activity of Children
Scruggs, P. W. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318126c1aa · Cited by 30
Influence of xylazine on the function of the LiDCO sensor in isoflurane anaesthetized horses
Hopster, K., Ambrisko, T. D., Stahl, J., Schramel, J. P., & Kästner, S. (2014) · Veterinary Anaesthesia and Analgesia · doi:10.1111/vaa.12181 · Cited by 22
Cystatin C-based glomerular filtration rate estimating equations in early chronic kidney disease
Hari, P., Ramakrishnan, L., Gupta, R., Kumar, R., & Bagga, A. (2014) · Indian Pediatrics · doi:10.1007/s13312-014-0400-5 · Cited by 22
Évaluation clinique du tonomètre dynamique de contour Pascal®
Detry-Morel, M., Jamart, J., Detry, M. B., Ledoux, A., & POURJAVAN, S. (2007) · Journal Français d Ophtalmologie · doi:10.1016/s0181-5512(07)89588-x · Cited by 22
Cooke, D. G., Binnie, J. E., & Blackwell, L. F. (2007) · Steroids · doi:10.1016/j.steroids.2007.03.009 · Cited by 24
Epicardial Colour-Doppler Scanning of Coronary Artery Stenoses and Graft Anastomoses
Haaverstad, R., Vitale, N., Williams, R. I., & Fraser, A. G. (2002) · Scandinavian Cardiovascular Journal · doi:10.1080/140174302753675375 · Cited by 22
Virji, M. A., Woskie, S., Waters, M. A., Brueck, S., Stancescu, D., Gore, R. J., Estill, C. F., & Prince, M. M. (2009) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mep010 · Cited by 25
Validation of the French Version of the World Health Organization Quality of Life HIV Instrument
Reychler, G., Caty, G. D., Vincent, A., Billo, S., & Yombi, J. C. (2013) · PLoS ONE · doi:10.1371/journal.pone.0073180 · Cited by 26
Aartun, E., Degerfalk, A., Kentsdotter, L., & Hestbæk, L. (2014) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-15-37 · Cited by 29
Leonard, M. B., Justine Shults, A., & Zemel, B. S. (2006) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2006.05.008 · Cited by 22
Pathak, S., Jessop, F. A., Hook, L., Sebire, N. J., & Lees, C. C. (2010) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767051003615434 · Cited by 22
Dioum, A., Gartner, A., Maire, B., Delpeuch, F., & Wade, S. (2005) · British Journal Of Nutrition · doi:10.1079/bjn20051426 · Cited by 27
Iqbal, H. S., Balakrishnan, P., Cecelia, A. J., Solomon, S., Kumarasamy, N., Madhavan, V., Murugavel, K. G., Ganesh, A. K., Solomon, S. S., Mayer, K. H., et al. (2007) · Journal of Medical Microbiology · doi:10.1099/jmm.0.47456-0 · Cited by 22
Achat, H. M., & Stubbs, J. M. (2012) · Journal of Paediatrics and Child Health · doi:10.1111/j.1440-1754.2012.02474.x · Cited by 22
Kühnisch, J., Heinrich‐Weltzien, R., Tabatabaie, M. H., Stösser, L., & Huysmans, M. C. D. N. J. M. (2006) · Caries Research · doi:10.1159/000091055 · Cited by 22
Kidney growth in small-for-gestational-age infants: evidence of early accelerated renal growth
Giapros, V. I., Drougia, A. A., Hotoura, E., Papadopoulou, F., Argyropoulou, M. I., & Andronikou, S. K. (2006) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfl466 · Cited by 22
Westermann, Y., Geigenmüller, A., Elgeti, T., Wagner, M., Dushe, S., Borges, A. C., Dohmen, P. M., Hein, P. A., & Lembcke, A. E. (2009) · European Journal of Radiology · doi:10.1016/j.ejrad.2009.08.014 · Cited by 22
Holden, L., Pourcelot, P., Desquilbet, L., Falala, S., Crevier‐Denoix, N., & Château, H. (2013) · The Veterinary Journal · doi:10.1016/j.tvjl.2013.02.004 · Cited by 22
Chhibber, A. K., Kolano, J. W., & Roberts, W. A. (1996) · Anesthesia & Analgesia · doi:10.1097/00000539-199602000-00005 · Cited by 22
Validation of energy requirement equations for estimation of breast milk consumption in infants
Schoen, S., Sichert‐Hellert, W., & Kersting, M. (2009) · Public Health Nutrition · doi:10.1017/s1368980009005503 · Cited by 22
Quantification of Pericardial Effusions by Echocardiography and Computed Tomography
Leibowitz, D. W., Perlman, G., Planer, D., Gilon, D., Berman, P. M., & Bogot, N. (2011) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2010.08.072 · Cited by 22
Grimaldi, E., VECCHIO, L. D., Scopacasa, F., PARDO, C. L., CAPONE, F., PARIANTE, S., SCALIA, G., & Caterina, M. D. (2009) · International Journal of Laboratory Hematology · doi:10.1111/j.1751-553x.2007.01015.x · Cited by 22
Thermodilution cardiac output: Comparison between automated and manual injection of indicator
Thrush, D. N., & Varlotta, D. (1992) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/1053-0770(91)90038-u · Cited by 22
Cheng, S.-C., Hulse, D., Fairbairn, K. J., Clarke, M., & Wallace, W. A. (2007) · Skeletal Radiology · doi:10.1007/s00256-007-0401-8 · Cited by 22
Analysis of the thoracic aorta using a semi-automated post processing tool
Entezari, P., Kino, A., Honarmand, A. R., Galizia, M. S., Yang, Y., Collins, J. D., Yaghmai, V., & Carr, J. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2013.03.024 · Cited by 24
Marx, G., Schuerholz, T., Sümpelmann, R., Simon, T.-P., & Leuwer, M. (2005) · European Journal of Anaesthesiology · doi:10.1017/s0265021505000244 · Cited by 22
Wyss, T. R., Dick, F., England, A., Brown, L. C., Rodway, A. D., & Greenhalgh, R. M. (2009) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2009.09.007 · Cited by 23
Comparison of 2 multiple-measurement infrared pupillometers to determine scotopic pupil diameter
Michel, A. W., Kronberg, B. P., Narváez, J., & Zimmerman, G. J. (2006) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2006.07.019 · Cited by 22
Modlesky, C. M., Cavaiola, M. L., Smith, J. J., Rowe, D. A., Johnson, D. L., & Miller, F. (2010) · Journal of Nutrition · doi:10.3945/jn.110.126219 · Cited by 25
Kandathil, A. J., Kannangai, R., David, S., Nithyanandam, G., Solomon, S., Balakrishnan, P., Abraham, O. C., Subramanian, S., Rupali, P., Verghese, V. P., et al. (2005) · Clinical and Vaccine Immunology · doi:10.1128/cdli.12.8.1006-1009.2005 · Cited by 23
Detection of Nonesterified (Free) Fatty Acids in Bovine Serum: Comparative Evaluation of Two Methods
Miksa, I. R., Buckley, C. L., & Poppenga, R. H. (2004) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/104063870401600208 · Cited by 22
Pitfalls in blood pressure measurement in daily practice
Houweling, S. T., Kleefstra, N., Lutgers, H. L., Groenier, K. H., Jong, B. M., & Bilo, H. J. G. (2005) · Family Practice · doi:10.1093/fampra/cmi096 · Cited by 23
What Is Accuracy and How Close Must the Agreement Be?
Nichols, J. H. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.558 · Cited by 22
Tiessen, R. G., Rhemrev-Boom, M. M., & Korf, J. (2002) · Life Sciences · doi:10.1016/s0024-3205(02)01515-1 · Cited by 24
Morphometrical dimensions of the sheep thoracolumbar vertebrae as seen on digitised CT images
Mageed, M., Berner, D., Jülke, H., Hohaus, C., Brehm, W., & Gerlach, K. (2013) · Laboratory Animal Research · doi:10.5625/lar.2013.29.3.138 · Cited by 22
Lin, Y., Wu, M., Huang, T., Tsai, S., Chung, H., Mai, V. M., Chen, C., & Pan, H. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20301 · Cited by 22
Reproducibility of the Measurement of the Muscle Ergoreflex Activity in Chronic Heart Failure
Scott, A., Francis, D. P., Coats, A. J. S., & Piepoli, M. F. (2003) · European Journal of Heart Failure · doi:10.1016/s1388-9842(03)00012-6 · Cited by 22
Valverde, A., Gianotti, G., Rioja, E., & Hathway, A. (2011) · Journal of Veterinary Emergency and Critical Care · doi:10.1111/j.1476-4431.2011.00650.x · Cited by 22
Boelens, M. C., Meerman, G. J. T., Gibcus, J. H., Blokzijl, T., Boezen, H. M., Timens, W., Postma, D. S., Groen, H. J. M., & van den Berg, A. (2007) · BMC Genomics · doi:10.1186/1471-2164-8-277 · Cited by 22
Reliability and Validity of Standing Balance Measurements with a Motion Analysis System
Kejonen, P., & Kauranen, K. J. (2002) · Physiotherapy · doi:10.1016/s0031-9406(05)60526-3 · Cited by 23
Plasma free and total carnitine measured in children by tandem mass spectrometry
Osório, J. H., & Pourfarzam, M. (2002) · Brazilian Journal of Medical and Biological Research · doi:10.1590/s0100-879x2002001100003 · Cited by 26
Zhang, Y., Sun, K., Zhu, S.-L., Wu, L., Chen, G.-Z., Zhang, Z., Chen, S., Li, F., & Yi, X. (2008) · World Journal of Pediatrics · doi:10.1007/s12519-008-0021-y · Cited by 22
Comparison of the measurement properties of the AQoL and SF-6D in critical illness
Skinner, E. H., Denehy, L., Warrillow, S. J., & Hawthorne, G. (2013) · Critical Care and Resuscitation · doi:10.1016/s1441-2772(23)01797-0 · Cited by 24
Tidal volume measurements in infants: Opto‐electronic plethysmography versus pneumotachograph
Reinaux, C., Aliverti, A., da Silva, L. G. M., da Silva, R. J., Gonçalves, J. N., Noronha, J. B., Filho, J. E. C., de Andrade, A. D., & de Britto, M. C. A. (2016) · Pediatric Pulmonology · doi:10.1002/ppul.23394 · Cited by 22
Doppler Ultrasound Triggering for Cardiovascular MRI at 3T in a Healthy Volunteer Study
Kording, F., Yamamura, J., Lund, G., Ueberle, F., Jung, C., Adam, G., & Schoennagel, B. P. (2016) · Magnetic Resonance in Medical Sciences · doi:10.2463/mrms.mp.2015-0104 · Cited by 22
Macnab, A. J., Levine, M., Glick, N., Phillips, N., Susak, L. E., & Elliott, M. (1994) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03010934 · Cited by 24
Assessment of a blood pressure measurement training programme for lay observers
Graciani, A., Banegas, J. R., López‐García, E., Díez‐Gañán, L., & Rodríguez‐Artalejo, F. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200210000-00001 · Cited by 22
Wickham, F., Burniston, M. T., Xirouchakis, E., Theocharidou, E., Wesolowski, C. A., Hilson, A. J. W., & Burroughs, A. K. (2013) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e32836529ab · Cited by 22
Predicting basal metabolic rates in Malaysian adult elite athletes.
Wong, J. E., Bk, P., Safii, N. S., Mohamad, M. I., Chan, K. Q., Tai, Ng, W. W., & Ismail, M. N. (2012) · PubMed · Cited by 31
The Role of Body Habitus in Predicting Cardiorespiratory Fitness: The FRIEND Registry
Baynard, T., Arena, R. A., MYERS, J. N., & Kaminsky, L. A. (2016) · International Journal of Sports Medicine · doi:10.1055/s-0042-110572 · Cited by 25
Lung volume reproducibility under ABC control and self‐sustained breath‐holding
Kaza, E., Dunlop, A., Panek, R., Collins, D. J., Orton, M. R., Symonds‐Tayler, R., Mcquaid, D., Scurr, E. D., Hansen, V. N., & Leach, M. O. (2017) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.12034 · Cited by 22
Interrater and Test‐Retest Reliability of the Beery Visual‐Motor Integration in Schoolchildren
Harvey, E. M., Leonard-Green, T. K., Mohan, K. M., Kulp, M. T., Davis, A. L., Miller, J. M., Twelker, J. D., Campus, I., & Dennis, L. K. (2017) · Optometry and Vision Science · doi:10.1097/opx.0000000000001068 · Cited by 22
Test–retest reliability of wrist joint position sense in healthy adults in a clinical setting
Pilbeam, C., & Hood-Moore, V. (2018) · Hand Therapy · doi:10.1177/1758998318770227 · Cited by 27
Trefán, L., Harris, C., Evans, S., Nuttall, D., Maguire, S., & Kemp, A. (2018) · Journal of Forensic and Legal Medicine · doi:10.1016/j.jflm.2018.07.015 · Cited by 23
Assessment of Image-Guided Interventions
Jannin, P., & Korb, W. (2008) · Springer eBooks · doi:10.1007/978-0-387-73858-1_18 · Cited by 22
O’Connell, A., Tibballs, J., & Coulthard, M. G. (1991) · Anaesthesia and Intensive Care · doi:10.1177/0310057x9101900323 · Cited by 22
Shih, A., Giguère, S., Vigani, A., Shih, R. S., Thuramalla, N. V., & Bandt, C. (2011) · Veterinary Anaesthesia and Analgesia · doi:10.1111/j.1467-2995.2011.00604.x · Cited by 22
Nielsen, R. G., Kruse-Andersen, S., & Husby, S. (2003) · Digestive Diseases and Sciences · doi:10.1023/a:1024703504585 · Cited by 22
Hertel Exophthalmometry without Orbital Rim Contact
Krátký, V., & Hurwitz, J. J. (1994) · Ophthalmology · doi:10.1016/s0161-6420(94)31235-8 · Cited by 22
Özdem, S., Akbas, H. S., Dönmez, L., & Gültekin, M. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.075 · Cited by 22
Rakhmanina, N. Y., Capparelli, E. V., van den Anker, J. N., Williams, K., Sever, J. L., Spiegel, H. M. L., & Soldin, S. J. (2007) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0b013e31803258ed · Cited by 22
Sureshkumar, P., Cumming, R. G., & Craig, J. C. (2006) · The Journal of Urology · doi:10.1016/s0022-5347(06)00339-9 · Cited by 22
Assessment of Local Differences in Intima-Media Thickness in the Human Common Carotid Artery
Willekes, C., Brands, P. J., Willigers, J. M., Hoeks, A. P. G., & Reneman, R. S. (1999) · Journal of Vascular Research · doi:10.1159/000025645 · Cited by 22
Wergel‐Kolmert, U., Ågehäll, A., Rosenberg, N., & Wohlfart, B. (2001) · Clinical Physiology · doi:10.1046/j.1365-2281.2001.00313.x · Cited by 28
Haney, M., Johansson, G., Häggmark, S., & Biber, B. (2001) · Acta Anaesthesiologica Scandinavica · doi:10.1034/j.1399-6576.2001.045006702.x · Cited by 22
Escalante, J. B., & Rosenfield, M. (2006) · Optometry · doi:10.1016/j.optm.2006.02.006 · Cited by 22
Malm, S., Sagberg, E., Larsson, H. B. W., & Skjærpe, T. (2005) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2005.03.002 · Cited by 22
A reproducible and variable intensity cycling performance protocol for warm conditions
Marino, F. E., Kay, D., Cannon, J., Serwach, N., & Hilder, M. (2002) · Journal of science and medicine in sport · doi:10.1016/s1440-2440(02)80030-5 · Cited by 22
Accuracy and Precision of PIXImus Densitometry for Ex Vivo Mouse Long Bones
Franco, G. E. L., O’Neil, T. K., Litscher, S. J., Urban-Piette, M., & Blank, R. D. (2004) · Journal of Clinical Densitometry · doi:10.1385/jcd:7:3:326 · Cited by 22
NORMAN, S., Eager, R. A., Waran, N. K., JEFFERY, L., Schroter, R. C., & MARLIN, D. J. (2004) · Physiology & Behavior · doi:10.1016/j.physbeh.2004.09.007 · Cited by 24
Alveolar recruitment assessed by positron emission tomography during experimental acute lung injury
Richard, J., Bars, D. L., Costes, N., Brégeon, F., Tourvieille, C., Lavenne, F., Janier, M. F., Gimenez, G., & Guérin, C. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0331-2 · Cited by 22
Effects of corneal thickness on intraocular pressure measured with three different tonometers
Murase, H., Sawada, A., Mochizuki, K., & Yamamoto, T. (2009) · Japanese Journal of Ophthalmology · doi:10.1007/s10384-008-0621-z · Cited by 22
Lund, S. S., Petersen, M., Frandsen, M., Smidt, U., Parving, H., Vaag, A. A., & Jensen, T. J. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2009.133868 · Cited by 23
Real-time measurement of pulse wave velocity from arterial pressure waveforms
Ramsey, M. W., Stewart, W. R., & Jones, C. J. H. (1995) · Medical & Biological Engineering & Computing · doi:10.1007/bf02510780 · Cited by 22
Assessment of volume and leak measurements during CPAP using a neonatal lung model
Fischer, H. S., Roehr, C. C., Proquitté, H., Wauer, R. R., & Schmalisch, G. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/1/007 · Cited by 22
Manga, P., Singh, S. K., Brandis, S., & Friedman, B. M. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90370-g · Cited by 22
Dual sugar permeability testing in diarrheal disease
Haase, A., Kukuruzovic, R. H., Dunn, K., Bright, A., & Brewster, D. (2000) · The Journal of Pediatrics · doi:10.1016/s0022-3476(00)70107-7 · Cited by 27
Greenfield, M. L. V. H., Kuhn, J. E. “., & Wojtys, E. M. (1996) · The American Journal of Sports Medicine · doi:10.1177/036354659602400324 · Cited by 22
An evaluation of two activated clotting time monitors during cardiac surgery
Reich, D. L., Zahl, K., Perucho, M., & Thys, D. M. (1992) · Journal of Clinical Monitoring and Computing · doi:10.1007/bf01618085 · Cited by 22
Kim, J., Wang, Z., Gallagher, D., Kotler, D. P., Ma, K., & Heymsfield, S. B. (1999) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/014860719902300261 · Cited by 26
Koide, Y., Yotsukura, M., Yoshino, H., & Ishikawa, K. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)00702-5 · Cited by 22
A Comparison Between Systolic Aortic Root Pressure and Finger Blood Pressure
Philippe, E., Hébert, J., Coirault, C., Zamani, K., Lecarpentier, Y., & Chemla, D. (1998) · CHEST Journal · doi:10.1378/chest.113.6.1466 · Cited by 23
Evaluation of transcutaneous CO2 responses following acute changes in PaCO2 in healthy subjects
Fuke, S., Miyamoto, K., Ohira, H., OHIRA, M., Odajima, N., & Nishimura, M. (2008) · Respirology · doi:10.1111/j.1440-1843.2008.01442.x · Cited by 22
Sekimoto, M., Fukui, M., & Fujita, K. (1997) · Anaesthesia · doi:10.1111/j.1365-2044.1997.249-az0389.x · Cited by 22
Influence of duration and hour of recording on spectral measurements of heart rate variability
Fauchier, L., Babuty, D., Autret, M. L., Poret, P., Cosnay, P., & Fauchier, J. P. (1998) · Journal of the Autonomic Nervous System · doi:10.1016/s0165-1838(98)00110-6 · Cited by 25
Diagnose depressie niet zo betrouwbaar te stellen
Terluin, B., van Hout, H. P. J., van Marwijk, H., Adèr, H. J., van der Meer, K., de Haan, M., & van Dyck, R. (2004) · Huisarts en Wetenschap · doi:10.1007/bf03084039 · Cited by 22
Buffington, C. W., & Nystrom, E. U. M. (2004) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000105923.09732.93 · Cited by 22
Wright, G. A., McDade, M., Martin, W., & Hutton, I. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/8/402 · Cited by 22
Analysis of canine and feline haemograms using the VetScan HMT analyser
Dewhurst, E. C., Crawford, E., Cue, S. M., Dodkin, S. J., German, A. J., & Papasouliotis, K. (2003) · Journal of Small Animal Practice · doi:10.1111/j.1748-5827.2003.tb00103.x · Cited by 22
Forrester, J. E., Sheehan, H. M. B., & Joffe, T. H. (2008) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2007.12.003 · Cited by 28
YLINEN, J. J., Teittinen, I., Kainulainen, V., Kautiainen, H., Vehmaskoski, K., & HÄKKINEN, A. H. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/9/003 · Cited by 22
Paliotti, R., Ciulla, M. M., Hennig, M., Tang, R., Bond, M. G., Mancia, G., Magrini, F., & Zanchetti, A. (2005) · Journal of Hypertension · doi:10.1097/01.hjh.0000170383.31085.14 · Cited by 23
MAIA, B., Engelson, E. S., Wang, J., & Kotler, D. P. (2005) · Clinical Nutrition · doi:10.1016/j.clnu.2005.06.012 · Cited by 22
Effects of acute myocardial ischemia on QT dispersion by Dipyridamole stress echocardiography
Carluccio, E., Biagioli, P., Bentivoglio, M., Mariotti, M., Politano, M., Savino, K., Sardone, M., Locati, E. H., & Ambrosio, G. (2003) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)03230-7 · Cited by 22
Müller, H., Burri, H., Shah, D. C., & Lerch, R. A. (2007) · Echocardiography · doi:10.1111/j.1540-8175.2007.00495.x · Cited by 22
Trunk anthropometry of Hong Kong Chinese infants
Fok, T. F., Hon, K. E., Wong, E. Y. L., Ng, P. C., So, H., Lau, J. T. F., Chow, C. B., & Lee, W. H. (2005) · Early Human Development · doi:10.1016/j.earlhumdev.2005.06.002 · Cited by 22
Tan, L. T., Warren, J., Freestone, G., & Jones, B. (1996) · British Journal of Radiology · doi:10.1259/0007-1285-69-826-953 · Cited by 22
Amirhamzeh, M. M. R., Dean, D. A., Jia, C.-X., Cabreriza, S. E., Yano, O. J., Burkhoff, D., & Spotnitz, H. M. (1996) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(96)00377-3 · Cited by 22
Stok, W. J., Stringer, R. C. O., & Karemaker, J. M. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.6.2266 · Cited by 24
Peake, M. J., Mazzachi, B. C., Fudge, A., & Bais, R. (2001) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456320103800511 · Cited by 22
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.