STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 20,301–20,400 of 47,868
Zhou, G., Huo, E.-Z., Yuan, M., Zhou, P., Wang, R., Wang, K., Chen, Y., & He, X. (2020) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2020.2979481 · Cited by 25
Niermann, C. Y. N., Wagner, P., Ziegeldorf, A., & Wulff, H. (2020) · Journal of Family Studies · doi:10.1080/13229400.2020.1773901 · Cited by 30
Fernández, J., Rodríguez‐Vallejo, M., Martínez, J., Burguera, N., & Pinero, D. P. (2020) · European Journal of Ophthalmology · doi:10.1177/1120672120940202 · Cited by 22
Werner, C., Heldmann, P., Hummel, S., Bauknecht, L., Bauer, J. M., & Hauer, K. A. (2020) · Sensors · doi:10.3390/s20174866 · Cited by 31
Sigdel, T. K., Piehowski, P., Roy, S., Liberto, J. M., Hansen, J., Swensen, A., Zhao, R., Zhu, Y., Rashmi, P., Schroeder, A., et al. (2020) · Frontiers in Medicine · doi:10.3389/fmed.2020.00499 · Cited by 22
Patel, U., Pandey, M. K., Kannan, S., Samant, T. A., Gera, P. B., Mittal, N., Rane, S. U., Patil, A. J., Noronha, V., Joshi, A., et al. (2020) · British Journal of Cancer · doi:10.1038/s41416-020-01064-4 · Cited by 25
Lambert, C., Demirel, G. Y., Keller, T., Preijers, F. W. M. B., Psarra, K., Schiemann, M., Özcürümez, M. K., & Sack, U. (2020) · Frontiers in Immunology · doi:10.3389/fimmu.2020.02169 · Cited by 28
Accuracy evaluation of patient-specific 3D-printed aortic anatomy
Kaschwich, M., Horn, M., Matthiensen, S., Stahlberg, E., Behrendt, C., Matysiak, F., Bouchagiar, J., Dell, A. C., Ellebrecht, D. B., Bayer, A. U., et al. (2020) · Annals of Anatomy - Anatomischer Anzeiger · doi:10.1016/j.aanat.2020.151629 · Cited by 22
Pernot, P., & Savin, A. (2020) · The Journal of Chemical Physics · doi:10.1063/5.0006202 · Cited by 23
Gielis, W. P., Weinans, H., Nap, F. J., Roemer, F. W., & Foppen, W. (2020) · Journal of Personalized Medicine · doi:10.3390/jpm11010005 · Cited by 27
Mookiah, M. R. K., Hogg, S., MacGillivray, T., & Trucco, E. (2021) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2021.105969 · Cited by 26
Kottner, J., & Blume‐Peytavi, U. (2021) · International Wound Journal · doi:10.1111/iwj.13574 · Cited by 22
Goerke, S., Breitling, J., Korzowski, A., Paech, D., Zaiß, M., Schlemmer, H., Ladd, M. E., & Bachert, P. (2021) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28699 · Cited by 24
Barratt, G. K., Bellenger, C. R., Robertson, E. Y., Lane, J., & Crowther, R. G. (2021) · Sensors · doi:10.3390/s21072418 · Cited by 27
Arslan, J., Samarasinghe, G., Sowmya, A., Benke, K. K., Hodgson, L., Guymer, R. H., & Baird, P. N. (2021) · Translational Vision Science & Technology · doi:10.1167/tvst.10.8.2 · Cited by 24
Katô, H., Hidaka, N., Koga, M., Ogawa, N., Takahashi, S., Miyazaki, H., Nangaku, M., Makita, N., & Ito, N. (2021) · Journal of Bone and Mineral Metabolism · doi:10.1007/s00774-021-01258-7 · Cited by 22
Ottka, C., Vapalahti, K., Puurunen, J., Vahtera, L., & Lohi, H. (2021) · Veterinary Clinical Pathology · doi:10.1111/vcp.12954 · Cited by 25
Gossé, L. K., Wiesemann, F., Elwell, C. E., & Jones, E. J. H. (2021) · Infant Behavior and Development · doi:10.1016/j.infbeh.2021.101663 · Cited by 27
Kamran, R., Rodrigues, J. N., Dobbs, T. D., Wormald, J. C. R., Trickett, R. W., & Harrison, C. J. (2022) · Journal of Hand Surgery (European Volume) · doi:10.1177/17531934221087572 · Cited by 24
Development of a Prediction Model for Ascending Aortic Diameter Among Asymptomatic Individuals
Pirruccello, J. P., Lin, H., Khurshid, S. S., Nekoui, M., Weng, L.-C. C., Vasan, R. S., Isselbacher, E. M., Benjamin, E. J., Lubitz, S. A., Lindsay, M. E., et al. (2022) · JAMA · doi:10.1001/jama.2022.19701 · Cited by 24
Wąsowicz, M., Jerath, A., Bojko, B., Sharma, V. V., Pawliszyn, J. B., & McCluskey, S. A. (2011) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-011-9614-3 · Cited by 22
Agreement among measurements and estimations of glomerular filtration in children with cancer
Bernhardt, M. B., Moffett, B. S., Johnson, M. L., Tam, V. H., Thompson, P., & Garey, K. W. (2014) · Pediatric Blood & Cancer · doi:10.1002/pbc.25194 · Cited by 23
Prostate weight is the preferred measure of prostate size in radical prostatectomy cohorts
Hong, M. K. H., Yao, H. H., Rzetelski‐West, K., Namdarian, B., Pedersen, J., Peters, J. S., Hovens, C. M., & Corcoran, N. M. (2012) · British Journal of Urology · doi:10.1111/j.1464-410x.2012.11049.x · Cited by 22
Psychometric properties of a Norwegian version of Multiple Sclerosis Impact Scale (MSIS-29)
Smedal, T., Johansen, H. H., Myhr, K., & Strand, L. I. (2009) · Acta Neurologica Scandinavica · doi:10.1111/j.1600-0404.2009.01298.x · Cited by 23
The evaluation of a clinical scar scale for porcine burn scars
Wang, X., Kravchuk, O. Y., Liu, P.-Y., Kempf, M., van den Boogaard, C. J., Lau, P., Cuttle, L., Mill, J., & Kimble, R. M. (2009) · Burns · doi:10.1016/j.burns.2008.10.005 · Cited by 22
Bicarbonate kinetics and predicted energy expenditure in critically ill children
Sy, J., Gourishankar, A., Gordon, W. E., Griffin, D., Zurakowski, D., Roth, R. M., Coss‐Bu, J. A., Jefferson, L. S., Heird, W. C., & Castillo, L. (2008) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/88.2.340 · Cited by 24
Conaghan, P. G., Ejbjerg, B., Lassere, M. N., Bird, P., PETERFY, C. G., Emery, P., McQueen, F. M., Haavardsholm, E. A., O’Connor, P., Edmonds, J. P., et al. (2007) · PubMed · Cited by 22
Assessment of Acetabular Retroversion following Long Term Review of Salter's Osteotomy
Robb, C., Datta, A., Nayeemuddin, M., & Bache, C. E. (2009) · Hip International · doi:10.1177/112070000901900102 · Cited by 22
Evaluation of an ambulatory device, CID 102, in the diagnosis of obstructive sleep apnoea syndrome
Surell, C. V., Lemaigre, D., Leroy, M., Foucher, A., Hagenmuller, M. P., & Raffestin, B. (1995) · European Respiratory Journal · doi:10.1183/09031936.95.08050795 · Cited by 24
Kroll, C., Magera, M. J., Helgeson, J. K., Matern, D., & Rinaldo, P. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.11.2049 · Cited by 22
Comparison of Pulsed Wave and Color Doppler Myocardial Velocity Imaging in Healthy Dogs
Wess, G., Killich, M., & Hartmann, K. (2010) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.2009.0460.x · Cited by 22
Jacobs, M. A., Gültekin, D. H., & Kim, H. S. (2010) · Medical Physics · doi:10.1118/1.3475940 · Cited by 25
Marklund, M., Strömberg, E. A., Lærke, H. N., Knudsen, K. E. B., Kamal‐Eldin, A., Hooker, A. C., & Landberg, R. (2014) · Journal of Nutrition · doi:10.3945/jn.114.196220 · Cited by 25
Urinary NT-proBNP and ductal closure in preterm infants
Czernik, C., Metze, B. C., Müller, C., & Bührer, C. (2012) · Journal of Perinatology · doi:10.1038/jp.2012.86 · Cited by 22
Du, J., Xu, J., Wang, F., Guo, Y., Zhang, F., Wu, W., Zhang, Y., Chen, Q., Li, Y., & Cui, W. (2015) · Clinica Chimica Acta · doi:10.1016/j.cca.2015.02.022 · Cited by 22
Pawiński, T., Kunicki, P. K., Sobieszczanska-Malek, M., Gralak, B., & Szlaska, I. (2008) · Journal of Clinical Pharmacy and Therapeutics · doi:10.1111/j.1365-2710.2008.00973.x · Cited by 22
The reliability of clinical decisions based on the cervical vertebrae maturation staging method
Sohrabi, A., Ahari, S. B., Moslemzadeh, S. H., Rafighi, A., & Aghazadeh, Z. (2015) · European Journal of Orthodontics · doi:10.1093/ejo/cjv030 · Cited by 25
COSTA, A. D., Chalvidan, T., BELOUNAS, A., Messier, M., Viallet, M., Mansour, H., LAMAISON, D., DJIANE, P., & Isaaz, K. (2000) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2000.tb00171.x · Cited by 22
van Bussel, F. C. G., van Bussel, B. C. T., Hoeks, A. P. G., Roodt, J. O. ’., Henry, R. M. A., Ferreira, I., Vanmolkot, F. H. M., Schalkwijk, C. G., Stehouwer, C. D. A., & Reesink, K. D. (2015) · PLoS ONE · doi:10.1371/journal.pone.0115977 · Cited by 26
Hofman, H., Knaapen, P., Boellaard, R., Bondarenko, O., Götte, M., van Dockum, W. G., Visser, C. A., van Rossum, A. C., Lammertsma, A. A., & Visser, F. C. (2005) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2005.04.016 · Cited by 22
Feasibility of a RARE-based sequence for quantitative diffusion-weighted MRI of the spine
Raya, J. G., Dietrich, O., Birkenmaier, C., Sommer, J., Reiser, M. F., & Baur‐Melnyk, A. (2007) · European Radiology · doi:10.1007/s00330-007-0618-x · Cited by 22
Validation of bioimpedance estimates of cardiac output in preeclampsia
Scardo, J. A., Ellings, J. M., Vermillion, S. T., & Chauhan, S. P. (2000) · American Journal of Obstetrics and Gynecology · doi:10.1067/mob.2000.108892 · Cited by 22
Kinsella, S. M. (2006) · International Journal of Obstetric Anesthesia · doi:10.1016/j.ijoa.2006.03.010 · Cited by 22
Gladdish, S., Manawadu, D., BANYA, W. A. S., Cameron, J. D., Bulpitt, C. J., & Rajkumar, C. (2005) · Clinical Science · doi:10.1042/cs20040251 · Cited by 30
Azevedo, C. F., Hadlich, M. S., Petriz, J. L. F., Mendonça, L. A., Filho, J. N. M., & Rochitte, C. E. (2004) · Arquivos Brasileiros de Cardiologia · doi:10.1590/s0066-782x2004001400003 · Cited by 26
Undt, G., Murakami, K.-I., Clark, G. T., Ploder, O., Dem, A., Lang�, T., & Wiesinger, G. (2006) · Journal of Cranio-Maxillofacial Surgery · doi:10.1016/j.jcms.2005.12.005 · Cited by 22
Chhajed, P. N., Miedinger, D., Baty, F., Bernasconi, M., Heuss, L. T., Leuppi, J. D., & Tamm, M. (2009) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365510903450106 · Cited by 22
Brorsson, S., Nilsdotter, A., Hilliges, M., Sollerman, C., & Aurell, Y. (2008) · BMC Medical Imaging · doi:10.1186/1471-2342-8-6 · Cited by 23
Manual planimetric measurement of carotid plaque volume using three‐dimensional ultrasound imaging
Landry, A., Ainsworth, C. D., Blake, C., Spence, J. D., & Fenster, A. (2007) · Medical Physics · doi:10.1118/1.2715487 · Cited by 22
Johnson, D. E., El-Defrawy, S. R., Almeida, D. R. P., & Bell, C. M. (2009) · Canadian Journal of Ophthalmology · doi:10.3129/i09-106 · Cited by 22
Christoforidis, A., Badouraki, M., Katzos, G. S., & Athanassiou‐Metaxa, M. (2007) · Pediatric Radiology · doi:10.1007/s00247-007-0656-1 · Cited by 22
Chládek, J., Zimová, G., Martı́nková, J., & Tůma, I. (1999) · Fundamental and Clinical Pharmacology · doi:10.1111/j.1472-8206.1999.tb00011.x · Cited by 22
A comparison of two methods of dietary assessment in peritoneal dialysis patients
Griffiths, A., Russell, L. H., Breslin, M., Russell, G. I., & Davies, S. (1999) · Journal of Renal Nutrition · doi:10.1016/s1051-2276(99)90019-5 · Cited by 22
Hiromoto, K., Shimizu, H., Mine, T., Masuyama, T., & Ohyanagi, M. (2006) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2006.00121.x · Cited by 22
Chanson, P., Cailleux-Bounacer, A., Kuhn, J.-M., Weryha, G., Chabre, O., Borson-Chazot, F., Dubois, S., Vincent-Dejean, C., Brue, T., Fedou, C., et al. (2010) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-0295 · Cited by 22
Access Flow in Arteriovenous Accesses by Optodilutional and Ultrasound Dilution Methods
Tonelli, M. A., Klarenbach, S. W., Jindal, K., Harries, S., Zuidema, S., Caldwell, S., & Pannu, N. (2005) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2005.08.002 · Cited by 22
The reliability of the frequency‐volume chart in assessing lower urinary tract symptoms
Yap, T., Cromwell, D. A., Brown, C. T., Emberton, M., & van der Meulen, J. (2007) · British Journal of Urology · doi:10.1111/j.1464-410x.2007.06864.x · Cited by 22
Buckley, J., Sim, J., & Eston, R. G. (2009) · Ergonomics · doi:10.1080/00140130802707691 · Cited by 22
Statistical methods for bioimpedance analysis
Tronstad, C., & Pripp, A. H. (2014) · Journal of Electrical Bioimpedance · doi:10.5617/jeb.830 · Cited by 22
Brun, J. ‐., Ghanassia, É., Fédou, C., Bordenave, S., de Mauverger, É. R., & Mercier, J. G. (2010) · Acta Diabetologica · doi:10.1007/s00592-010-0232-2 · Cited by 24
Yokoo, E. M., Valente, J. G., Sichieri, R., & Silva, E. C. (2001) · Environmental Research · doi:10.1006/enrs.2001.4241 · Cited by 22
Diniz, A. L. D., Tomé, R. A. F., Debs, C. L., Carraro, R., Roever, L., & Pinto, R. D. M. C. (2009) · Radiologia Brasileira · doi:10.1590/s0100-39842009000600007 · Cited by 22
A survey of peri‐operative use of magnesium sulphate in adult cardiac surgery in the UK
Roscoe, A., & Ahmed, A. B. (2003) · Anaesthesia · doi:10.1046/j.1365-2044.2003.03082_1.x · Cited by 25
Krasinski, A., Chiu, B. C. Y., Fenster, A., & Párraga, G. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21709 · Cited by 25
Reiter, G., Reiter, U., Rienmüller, R., Гагарина, Н. В., & Ryabikin, A. (2003) · European Journal of Radiology · doi:10.1016/j.ejrad.2003.10.003 · Cited by 25
Pavlov, L., Gamble, G. D., & Reid, I. R. (2005) · Journal of Clinical Densitometry · doi:10.1385/jcd:8:4:379 · Cited by 22
Volumetric Analysis of Liver Metastases in Computed Tomography With the Fuzzy C-Means Algorithm
Yim, P. J., Vora, A. V., Raghavan, D., Prasad, R. S., McAuliffe, M., Ohman‐Strickland, P., & Nosher, J. L. (2006) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200603000-00008 · Cited by 22
Chikkalingaiah, K. B. M., Grant, N. D., Mangold, T. M., Cooke, C. R., & Wall, B. M. (2010) · The American Journal of the Medical Sciences · doi:10.1097/maj.0b013e3181c62279 · Cited by 22
Vargas, F., Gruson, D., Valentino, R., Bui, H. N., Salmi, L., Gilleron, V., Gbikpi-Benissan, G., Guénard, H. J.-P., & Hilbert, G. (2004) · Journal of Critical Care · doi:10.1016/j.jcrc.2004.07.009 · Cited by 22
Claudius, C., Skovgaard, L. T., & Viby-Mogensen, J. (2009) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2008.01866.x · Cited by 22
Merrill, R. D., Shamim, A. A., Labrique, A. B., Ali, H., Schulze, K. J., Rashid, M., Christian, P. S., & West, K. P. (2009) · Journal of Health Population and Nutrition · doi:10.3329/jhpn.v27i3.3384 · Cited by 22
Anxiety and worry when coping with cancer treatment: agreement between patient and proxy responses
Hermont, A. P., Scarpelli, A. C., Paiva, S. M., Auad, S. M., & Pordeus, I. A. (2014) · Quality of Life Research · doi:10.1007/s11136-014-0869-3 · Cited by 28
Barbosa-Cortés, L., Vera, H., Morán, S., Prado, M. D., & López-Alarcón, M. (2005) · Nutrition · doi:10.1016/j.nut.2004.05.027 · Cited by 22
Harloff, A., Brendecke, S. M., Simon, J., Assefa, D., Wallis, W., Helbing, T., Weber, J., Frydrychowicz, A. P., Vach, W., Weiller, C., et al. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23679 · Cited by 22
Blanchet, B., Taïeb, F., Conti, F., Abbas, H., Seydi, I., Harcouët, L., Dauphin, A., Calmus, Y., & Tod, M. M. (2008) · Liver Transplantation · doi:10.1002/lt.21607 · Cited by 22
Digital stereoscopic analysis of the optic disc
Sheen, N. J. L., Morgan, J. E., Poulsen, J. L., & North, R. V. (2004) · Ophthalmology · doi:10.1016/j.ophtha.2004.04.018 · Cited by 22
Baldelli, S., Crippa, A., Gabrieli, R., FIOCCHI, R., Perico, N., Merlini, S., Ottomano, C., & Cattaneo, D. (2006) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2006.08.013 · Cited by 22
Olmedilla‐Alonso, B., Granado‐Lorencio, F., & Blanco-Navarro, I. (2005) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2005.02.001 · Cited by 22
The Repeatability of Forced Expiratory Volume Measurements in Adults With Cystic Fibrosis
Stanbrook, M. B., Corey, M. L., & Tullis, D. E. (2004) · CHEST Journal · doi:10.1378/chest.125.1.150 · Cited by 22
Breath-holding test in subjects with near-fatal asthma. A new index for dyspnea perception
Nannini, L. J., ZAIETTA, G. A., Guerrera, A. J., Varela, J. A., Fernández, O., & Flores, D. M. (2006) · Respiratory Medicine · doi:10.1016/j.rmed.2006.05.013 · Cited by 22
Wolf, M., von Siebenthal, K., Keel, M., Dietz, V., Baenziger, O., & Bucher, H. U. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1463044 · Cited by 22
Jajda, H. M., Patel, K. G., Patel, S. R., Solanki, V. H., Patel, K. N., & Singh, S. (2013) · Journal of Food Science and Technology · doi:10.1007/s13197-013-1088-6 · Cited by 23
Dysinger, M., & King, L. E. (2012) · Journal of Immunological Methods · doi:10.1016/j.jim.2012.02.017 · Cited by 22
Dodson, J. L., Jerry-Fluker, J., Ng, D. K., Moxey‐Mims, M., Schwartz, G. J., Dharnidharka, V. R., Warady, B. A., & Furth, S. L. (2011) · The Journal of Urology · doi:10.1016/j.juro.2011.05.059 · Cited by 22
Buczinski, S., Doré, E., Boulay, G., & Francoz, D. (2014) · Veterinary Clinical Pathology · doi:10.1111/vcp.12185 · Cited by 22
Test?Retest Reliability of the Sunnaas ADL Index
Bathen, T. (2001) · Scandinavian Journal of Occupational Therapy · doi:10.1080/110381201750464494 · Cited by 22
PIIANP and HELIXII diurnal variation
Quintana, D. J., Garnero, P., Huebner, J. L., Tabassi, N. C.-B., & Kraus, V. B. (2008) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2008.03.006 · Cited by 22
Schminke, U., Lorenz, L., Kirsch, M., von Sarnowski, B., Khaw, A. V., Kessler, C., & Dressel, A. (2009) · Journal of Neuroimaging · doi:10.1111/j.1552-6569.2008.00321.x · Cited by 22
Simón, R., Ni, Q., WILLEMS, R., Hartley, J., Daum, D. R., Lang, D. J., Ward, K. J., & Gill, J. S. (2003) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2003.00331.x · Cited by 22
Williams, J., McDonough, M. A., Hilliard, M. W., Williams, A. L., Cuniowski, P. C., & Gonzalez, M. G. (2009) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2009.00505.x · Cited by 22
Riedijk, M. A., Voortman, G. J., & van Goudoever, J. B. (2005) · Pediatric Research · doi:10.1203/01.pdr.0000181374.73234.80 · Cited by 22
Design and Validation of a Comprehensive Fecal Incontinence Questionnaire
Macmillan, A. K., Merrie, A. E. H., Marshall, R. J., & Parry, B. R. (2008) · Diseases of the Colon & Rectum · doi:10.1007/s10350-008-9301-9 · Cited by 22
Clapperton, A. T., Coward, W. A., & Bluck, L. J. C. (2002) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.815 · Cited by 22
Jin, R., Donaghue, K., Fairchild, J., Chan, A., & Silink, M. (2001) · Journal of Paediatrics and Child Health · doi:10.1046/j.1440-1754.2001.00752.x · Cited by 24
Reliability of bladder volume measurement with BladderScan® in paediatric patients
GENNARO, M. D., Capitanucci, M. L., Ciommo, V. M. D., Adorisio, O. D., Mosiello, G., Orazi, C., & Tubaro, A. (2006) · Scandinavian Journal of Urology and Nephrology · doi:10.1080/00365590600679137 · Cited by 22
Validation of Primary CD4 Gating as an Affordable Strategy for Absolute CD4 Counting in Cambodia
Lynen, L., Teav, S., Vereecken, C., Munter, P. D., An, S., Jacques, G., & Kestens, L. (2006) · JAIDS Journal of Acquired Immune Deficiency Syndromes · doi:10.1097/01.qai.0000242447.82403.c2 · Cited by 22
Cameli, M., Lisi, M., Mondillo, S., Padeletti, M., Ballo, P., Bigio, E., Marchetti, L., & Biagioli, B. (2011) · Journal of Critical Care · doi:10.1016/j.jcrc.2010.11.011 · Cited by 22
Accuracy of Real-Time Single- and Multi-Beat 3-D Speckle Tracking Echocardiography In Vitro
Hjertaas, J. J., Fosså, H., Dybdahl, G. L., Grüner, R., Lunde, P., & Matre, K. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2013.01.010 · Cited by 22
Bedside Hemoglobinometry in Hemodialysis Patients: Lessons from Point-of-Care Testing
Agarwal, R., & Heinz, T. (2001) · ASAIO Journal · doi:10.1097/00002480-200105000-00016 · Cited by 22
Sénat, M., Quarello, E., Levaillant, J. M., Buonumano, A., Boulvain, M., & Frydman, R. (2006) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.2835 · Cited by 22
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.