STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 3,301–3,400 of 47,868
Evaluation of a routine diagnostic fecal panel for dogs with diarrhea
Cave, N., Marks, S. L., Kass, P. H., Melli, A. C., & Brophy, M. A. (2002) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.2002.221.52 · Cited by 145
Verschuren, O. W., Takken, T., Ketelaar, M., Gorter, J. W., & Helders, P. J. M. (2006) · Physical Therapy · doi:10.1093/ptj/86.8.1107 · Cited by 133
Six‐minute walk test in obese children and adolescents: Reproducibility and validity
Morinder, G., Mattsson, E., Sollander, C., Marcus, C., & Larsson, U. E. (2008) · Physiotherapy Research International · doi:10.1002/pri.428 · Cited by 148
Østbye, T., Tyas, S. L., McDowell, I., & Koval, J. J. (1997) · Age and Ageing · doi:10.1093/ageing/26.2.99 · Cited by 119
The influence of scoring method on variability in results obtained with the comet assay
Azqueta, A., Meier, S., Priestley, C. C., Gützkow, K. B., Brunborg, G., Sallette, J., Soussaline, F. P., & Collins, A. R. (2011) · Mutagenesis · doi:10.1093/mutage/geq105 · Cited by 119
Detecting postoperative urinary retention with an ultrasound scanner
Rosseland, L. A., Stubhaug, A., & Breivik, H. (2002) · Acta Anaesthesiologica Scandinavica · doi:10.1034/j.1399-6576.2002.t01-1-460309.x · Cited by 119
Analysis of cover of the femoral head in normal and dysplastic hips
Dandachli, W., Kannan, V., Richards, R., Shah, Z., Hall-Craggs, M. A., & Witt, J. D. (2008) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.90b11.20073 · Cited by 119
Repeatability and reproducibility of macular thickness measurements with the Humphrey OCT system.
Muscat, S., Parks, S., Kemp, E., & Keating, D. (2002) · PubMed · Cited by 119
Hale, L. A., Pal, J., & Becker, I. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2008.02.027 · Cited by 118
Validity of inspiratory and expiratory methods of measuring gas exchange with a computerized system
Bassett, D. R., Howley, E. T., Thompson, D. L., King, G. A., Strath, S. J., McLaughlin, J. E., & Parr, B. B. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.1.218 · Cited by 118
Stapel, S. N., de Grooth, H.-J. S., Alimohamad, H., Elbers, P. W. G., Girbes, A. R. J., Weijs, P. J. M., & Oudemans-van Straaten, H. M. (2015) · Critical Care · doi:10.1186/s13054-015-1087-2 · Cited by 118
Reliability of Objectively Measured Sedentary Time and Physical Activity in Adults
Aadland, E., & Ylvisåker, E. (2015) · PLoS ONE · doi:10.1371/journal.pone.0133296 · Cited by 143
Fackrell, K., Hall, D. A., Barry, J. G., & Hoare, D. J. (2016) · Hearing Research · doi:10.1016/j.heares.2015.09.009 · Cited by 118
Havre, R. F., Elde, E., Gilja, O. H., Ødegaard, S., Eide, G. E., Matre, K., & Nesje, L. B. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.03.009 · Cited by 127
Venous blood lactate evaluation in equine neonatal intensive care
Castagnetti, C., Pirrone, A., Mariella, J., & Mari, G. (2009) · Theriogenology · doi:10.1016/j.theriogenology.2009.09.018 · Cited by 118
Praditpornsilpa, K., Townamchai, N., Chaiwatanarat, T., Tiranathanagul, K., Katawatin, P., Susantitaphong, P., Trakarnvanich, T., Kanjanabuch, T., Avihingsanon, Y., Tungsanga, K., et al. (2011) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfq815 · Cited by 118
Abe, H., Caracciolo, G., Kheradvar, A., Pedrizzetti, G., Khandheria, B. K., Narula, J., & Sengupta, P. P. (2013) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jet049 · Cited by 118
Pouleur, A., de Waroux, J.-B. L. P., Pasquet, A., Gerber, B. L., Gérard, O., Allain, P., & Vanoverschelde, J. (2007) · Heart · doi:10.1136/hrt.2007.123711 · Cited by 121
Holland, T. K., Cutner, A., Saridogan, E., Mavrelos, D., Pateman, K., & Jurkovic, D. (2013) · BMC Women's Health · doi:10.1186/1472-6874-13-43 · Cited by 120
Gradmark, A., Rydh, A., Renström, F., Rolfe, E. D. L., Sleigh, A., Nordström, P., Brage, S., & Franks, P. W. (2010) · British Journal Of Nutrition · doi:10.1017/s0007114510000796 · Cited by 119
Bradley, J., Simpson, E. L., Poliakov, I., Matthews, J. N. S., Olivier, P. L., Adamson, A., & Foster, E. (2016) · Nutrients · doi:10.3390/nu8060358 · Cited by 135
Testicular growth and development in puberty
Koskenniemi, J. J., Virtanen, H. E., & Toppari, J. (2017) · Current Opinion in Endocrinology Diabetes and Obesity · doi:10.1097/med.0000000000000339 · Cited by 132
Nosrati, M., & Tavassolian, N. (2017) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2017.2721407 · Cited by 126
Kloss, F. R., Offermanns, V., & Kloss‐Brandstätter, A. (2018) · Clinical Oral Implants Research · doi:10.1111/clr.13380 · Cited by 119
Bogataj, Š., Pajek, M., Hadžić, V., Andrašić, S., Padulo, J., & Trajković, N. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17103708 · Cited by 168
Mühlen, J. M., Stang, J., Lykke Skovgaard, E., Judice, P. B., Molina-Garcia, P., Johnston, W., Sardinha, L. B., Ortega, F. B., Caulfield, B., Bloch, W., et al. (2021) · British Journal of Sports Medicine · doi:10.1136/bjsports-2020-103148 · Cited by 116
Rahnenführer, J., Bin, R. D., Benner, A., Ambrogi, F., Lusa, L., Boulesteix, A., Migliavacca, E., Binder, H., Michiels, S., Sauerbrei, W., et al. (2023) · BMC Medicine · doi:10.1186/s12916-023-02858-y · Cited by 166
Quality of life on admission to the intensive care: can we query the relatives?
Hofhuis, J. G. M., Hautvast, J. L. A., Schrijvers, G., & Bakker, J. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1763-6 · Cited by 122
Estimation of Birth Weight by Two-Dimensional Ultrasonography: A Critical Appraisal of Its Accuracy
Scioscia, M., Vimercati, A., Ceci, O., Vicino, M., & Selvaggi, L. E. (2008) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000296656.81143.e6 · Cited by 119
Gopal, A. S., Schnellbaecher, M. J., Shen, Z., Boxt, L. M., Katz, J., & King, D. L. (1997) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(97)70045-2 · Cited by 118
Balzano, G., Stefanelli, F., IORIO, C., Felice, A. D., Melillo, E., Martucci, M., & Melillo, G. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.5.9810105 · Cited by 118
Ejbjerg, B., Vestergaard, A., Jacobsen, S., Thomsen, H. S., & Østergaard, M. (2005) · Arthritis & Rheumatism · doi:10.1002/art.21207 · Cited by 118
Jarvis, M., Primatesta, P., Erens, B., Feyerabend, C., & Bryant, A. (2003) · Nicotine & Tobacco Research · doi:10.1080/14622200307204 · Cited by 121
Comparison between two measures of delay discounting in smokers.
Epstein, L. H., Richards, J. B., Saad, F. G., Paluch, R. A., Roemmich, J. N., & Lerman, C. (2003) · Experimental and Clinical Psychopharmacology · doi:10.1037/1064-1297.11.2.131 · Cited by 119
Jeremias, A., Filardo, S. D., Whitbourn, R., Kernoff, R. S., Yeung, A. C., Fitzgerald, P. J., & Yock, P. G. (2000) · Circulation · doi:10.1161/01.cir.101.3.318 · Cited by 118
The PAM-RL ambulatory device for detection of periodic leg movements: a validation study
Sforza, E. A., Mathis, J., & Claudio, B. (2005) · Sleep Medicine · doi:10.1016/j.sleep.2005.01.004 · Cited by 126
Novel Insulin Sensitivity Index Derived from Oral Glucose Tolerance Test
Soonthornpun, S., Setasuban, W., Thamprasit, A., Chayanunnukul, W., Rattarasarn, C., & Geater, A. (2003) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2002-021127 · Cited by 119
Lintsi, M., Kaarma, H., & Kull, I. (2004) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2004.00534.x · Cited by 120
Three-dimensional imaging of orthodontic models: a pilot study
Asquith, J., Gillgrass, T., & Mossey, P. A. (2007) · European Journal of Orthodontics · doi:10.1093/ejo/cjm044 · Cited by 118
Wentholt, I. M., Vollebregt, M. A., Hart, A. A., Hoekstra, J. B., & DeVries, J. H. (2005) · Diabetes Care · doi:10.2337/diacare.28.12.2871 · Cited by 118
Fukuda, S., Gillinov, A. M., Song, J., Daimon, M., Kongsaerepong, V., Thomas, J. D., & Shiota, T. (2006) · American Heart Journal · doi:10.1016/j.ahj.2006.07.027 · Cited by 118
Stock, C. (2001) · Health Promotion International · doi:10.1093/heapro/16.2.145 · Cited by 117
Dwyer, G., Hardy, L. L., Peat, J. K., & Baur, L. A. (2011) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-8-86 · Cited by 129
Bioelectrical impedance for monitoring the efficacy of lymphoedema treatment programmes
Cornish, B., Bunce, I., Ward, L. C., Jones, L. C., & Thomas, B. J. (1996) · Breast Cancer Research and Treatment · doi:10.1007/bf01806671 · Cited by 118
Cai, W., Kassarjian, A., Bredella, M. A., Harris, G. J., Yoshida, H., Mautner, V. F., Wenzel, R., & Plotkin, S. R. (2009) · Radiology · doi:10.1148/radiol.2503080700 · Cited by 119
Emery, C. A., Cassidy, J. D., Klassen, T. P., Rosychuk, R. J., & Rowe, B. H. (2005) · Physical Therapy · doi:10.1093/ptj/85.6.502 · Cited by 119
Development Standards for Health Measures
McDowell, I., & Jenkinson, C. (1996) · Journal of Health Services Research & Policy · doi:10.1177/135581969600100410 · Cited by 120
Validation of salivary oxytocin and vasopressin as biomarkers in domestic dogs
MacLean, E. L., Gesquiere, L. R., Gee, N., Levy, K., Martin, W. L., & Carter, C. S. (2018) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2017.08.033 · Cited by 117
Translation in Arabic, adaptation and validation of the SF-36 Health Survey for use in Tunisia
Guermazi, M., Allouch, C., Yahia, M., Huissa, T. B. A., Ghorbel, S., Dammak, J., M’rad, M. F., & Elleuch, M. H. (2012) · Annals of Physical and Rehabilitation Medicine · doi:10.1016/j.rehab.2012.05.003 · Cited by 130
Martin, K. E., Helvie, M. A., Zhou, C., Roubidoux, M. A., Bailey, J. E., Paramagul, C., Blane, C. E., Klein, K. A., Sonnad, S. S., & Chan, H. (2006) · Radiology · doi:10.1148/radiol.2402041947 · Cited by 117
Puetz, T. W., MORLEY, C. A., & Herring, M. P. (2013) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2013.836 · Cited by 137
Reproducibility and validity of a diet quality index for children assessed using a FFQ
Huybrechts, I., Vereecken, C. A., Bacquer, D. D., Vandevijvere, S., Oyen, H. J. V., Maes, L., Vanhauwaert, E., Temme, L., Backer, G. D., & Henauw, S. D. (2010) · British Journal Of Nutrition · doi:10.1017/s0007114510000231 · Cited by 133
Sadda, S. R., Joeres, S., Wu, Z., Updike, P. G., Romano, P. W., Collins, A. T., & Walsh, A. C. (2007) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.06-0554 · Cited by 117
Kihara, T., Gillinov, A. M., Takasaki, K., Fukuda, S., Song, J., Shiota, M., & Shiota, T. (2009) · Echocardiography · doi:10.1111/j.1540-8175.2009.00904.x · Cited by 117
Testicular function in a birth cohort of young men
Hart, R. J., Doherty, D. A., McLachlan, R. I., Walls, M. L., Keelan, J. A., Dickinson, J. E., Skakkebaek, N. E., Norman, R. J., & Handelsman, D. J. (2015) · Human Reproduction · doi:10.1093/humrep/dev244 · Cited by 116
A New Equation to Estimate Muscle Mass from Creatinine and Cystatin C
Kim, S.-W., Jung, H.-W., Kim, C.-H., Kim, K.-I., Chin, H. J., & Lee, H. (2016) · PLOS ONE · doi:10.1371/journal.pone.0148495 · Cited by 116
Marventano, S., Mistretta, A., Platania, A., Galvano, F., & Grosso, G. (2016) · International Journal of Food Sciences and Nutrition · doi:10.1080/09637486.2016.1198893 · Cited by 117
A review of the design and validation of web- and computer-based 24-h dietary recall tools
Timon, C., van den Barg, R., Blain, R. J., Kehoe, L., Evans, K., Walton, J., Flynn, A., & Gibney, E. R. (2016) · Nutrition Research Reviews · doi:10.1017/s0954422416000172 · Cited by 130
Ambrosini, G. L., Hurworth, M., Giglia, R., Trapp, G., & Strauss, P. (2018) · Nutrition Journal · doi:10.1186/s12937-018-0315-4 · Cited by 120
Ultrasonography for chairside evaluation of periodontal structures: A pilot study
Tattan, M., Sinjab, K. H., Lee, E., Arnett, M. C., Oh, T., Wang, H., Chan, H., & Kripfgans, O. D. (2020) · Journal of Periodontology · doi:10.1002/jper.19-0342 · Cited by 127
Review of Validity and Reliability of Garmin Activity Trackers
Evenson, K. R., & Spade, C. L. (2020) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2019-0035 · Cited by 139
Galán‐Rioja, M. Á., González‐Mohíno, F., Poole, D. C., & González‐Ravé, J. M. (2020) · Sports Medicine · doi:10.1007/s40279-020-01314-8 · Cited by 144
Lehrer, H. M., Yao, Z., Krafty, R. T., Evans, M. A., Buysse, D. J., Kravitz, H. M., Matthews, K. A., Gold, E. B., Harlow, S. D., Samuelsson, L. B., et al. (2022) · SLEEP Advances · doi:10.1093/sleepadvances/zpac001 · Cited by 156
Berg, K. M., Bray, J., Ng, K.-C., Liley, H. G., Greif, R., Carlson, J. N., Morley, P. T., Drennan, I. R., Smyth, M. A., Scholefield, B. R., et al. (2023) · Resuscitation · doi:10.1016/j.resuscitation.2023.109992 · Cited by 134
Mukherjee, S., Yadav, R., Yung, I., Zajdel, D. P., & Oken, B. S. (2011) · Clinical Neurophysiology · doi:10.1016/j.clinph.2011.02.032 · Cited by 118
Frauenrath, T., Hezel, F., Renz, W., d'Orth, T. D. G., Dieringer, M. A., von Knobelsdorff‐Brenkenhoff, F., Prothmann, M., Schulz‐Menger, J., & Niendorf, T. (2010) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-12-67 · Cited by 117
Cannesson, M. P., Slieker, J. C., Desebbe, O., Bauer, C., Chiari, P. C., Hénaine, R., & Lehot, J. (2008) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000297291.01615.5c · Cited by 118
Pu, M., Vandervoort, P. M., Griffin, B. P., Leung, D. Y., Stewart, W. J., Cosgrove, D. M., & Thomas, J. D. (1995) · Circulation · doi:10.1161/01.cir.92.8.2169 · Cited by 117
Cingolani, H. E., Plastino, J. A. M., Escudero, E. M., Mangal, B., Brown, J., & Pérez, N. G. (2006) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2006.05.005 · Cited by 125
Voice handicap index in Swedish
Ohlsson, A., & Dotevall, H. (2009) · Logopedics Phoniatrics Vocology · doi:10.1080/14015430902839185 · Cited by 131
Fok, T. F., So, H. K., Wong, E., Ng, P. C., Chang, A., Lau, J., Chow, C. B., & Lee, W. H. (2003) · Archives of Disease in Childhood - Fetal and Neonatal Edition · doi:10.1136/fn.88.3.f229 · Cited by 117
Comparison of manual and automatic CPAP titration in patients with sleep apnea/hypopnea syndrome.
Lloberes, P., Ballester, E., Montserrat, J. M., Botifoll, E., Ramirez, A., Reolid, A., Gistau, C., & Rodriguez-Roisin, R. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.154.6.8970366 · Cited by 117
Guinhouya, C. B., Hubert, H., Soubrier, S., Vilhelm, C., Lemdani, M., & Durocher, A. (2006) · Obesity · doi:10.1038/oby.2006.89 · Cited by 117
Ravaud, P., Auleley, G.-R., Chastang, C., Rousselin, B., Paolozzi, L., Amor, B., & Dougados, M. (1996) · Rheumatology · doi:10.1093/rheumatology/35.8.761 · Cited by 117
Bross, R., Ball, R. O., & Pencharz, P. B. (1998) · Journal of Nutrition · doi:10.1093/jn/128.11.1913 · Cited by 117
Bolotin, H. H., Sievänen, H. T., Grashuis, J. L., Kuiper, J. W., & Järvinen, T. L. N. (2001) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2001.16.2.417 · Cited by 133
Espersen, K., Jensen, E. W., Rosenborg, D., Thomsen, J. K., Eliasen, K., Olsen, N. V., & Kanstrup, I.-L. (1995) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1995.tb04051.x · Cited by 117
Fowler, P., Fuller, M., Glasbey, C., Foster, M., Cameron, G., McNeill, G., & Maughan, R. J. (1991) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/54.1.18 · Cited by 117
Aortic compliance measurements using doppler ultrasound: In vivo biochemical correlates
Lehmann, E. D., Hopkins, K. D., & Gosling, R. G. (1993) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(93)90087-5 · Cited by 129
The effects of bisphosphonates on the resorption cycle of isolated osteoclasts
Selander, K. S., Lehenkari, P. P., & V��n�nen, H. K. (1994) · Calcified Tissue International · doi:10.1007/bf00299317 · Cited by 123
Bensimhon, D. R., Leifer, E. S., Ellis, S. J., Fleg, J. L., Keteyian, S. J., Piña, I. L., Kitzman, D. W., McKelvie, R. S., Kraus, W. E., Forman, D. E., et al. (2008) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2008.04.047 · Cited by 116
Home Self Blood Pressure Measurement in General Practice The SMART Study
Chatellier, G. (1996) · American Journal of Hypertension · doi:10.1016/0895-7061(96)00018-0 · Cited by 116
Mazze, R. S., Strock, E., Borgman, S., Wesley, D., Stout, P., & Racchini, J. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0041 · Cited by 116
Cheng, K. K. F., Wong, E. M. C., Ling, W. M., Chan, C. W. H., & Thompson, D. R. (2008) · Journal of Pain and Symptom Management · doi:10.1016/j.jpainsymman.2007.12.019 · Cited by 125
Budge, L. P., Shaffer, K. M., Moorman, J. R., Lake, D. E., Ferguson, J., & Mangrum, J. M. (2008) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-008-9281-7 · Cited by 126
Kwee, T. C., Takahara, T., Luijten, P. R., & Nievelstein, R. A. J. (2009) · European Journal of Radiology · doi:10.1016/j.ejrad.2009.03.026 · Cited by 125
Microdamage: A cell transducing mechanism based on ruptured osteocyte processes
Hazenberg, J. G., Freeley, M., Foran, E., Lee, T. C., & Taylor, D. M. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.06.006 · Cited by 135
Arterial Pressure Variation and Goal-Directed Fluid Therapy
Cannesson, M. P. (2009) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2009.10.008 · Cited by 124
Minimum detectable change for single-leg-stance-time in older adults
Goldberg, A., Casby, A., & Wasielewski, M. (2011) · Gait & Posture · doi:10.1016/j.gaitpost.2011.02.020 · Cited by 116
Normal biventricular function, volumes, and mass in children aged 8 to 17 years
Robbers‐Visser, D., Boersma, E., & Helbing, W. A. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21662 · Cited by 118
Evaluation of the catheter positioning for neurally adjusted ventilatory assist
Barwing, J., Ambold, M., Linden, N., Quintel, M., & Moerer, O. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1587-0 · Cited by 116
Reference Values of Impulse Oscillometric Lung Function Indices in Adults of Advanced Age
Schulz, H., Flexeder, C., Behr, J., Heier, M., Holle, R., Huber, R. M., Jörres, R. A., Nowak, D., Peters, A., Wichmann, H. ‐., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0063366 · Cited by 118
Gaspar, T., Adawi, S., Sachner, R., Asmer, I., Ganaeem, M., Rubinshtein, R., & Shiran, A. (2012) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2012.05.001 · Cited by 116
Energy expenditure in critically ill children
Hardy, C. M., LeLeiko, N. S., Dallal, G. E., Roubenoff, R., Snelling, L. K., & Dwyer, J. T. (2007) · Pediatric Critical Care Medicine · doi:10.1097/01.pcc.0000262802.81164.03 · Cited by 116
Specific food structures supress appetite through reduced gastric emptying rate
Mackie, A. R., Rafiee, H., Malcolm, P., Salt, L., & van Aken, G. (2013) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.00060.2013 · Cited by 116
Comparing the UK EQ-5D-3L and English EQ-5D-5L Value Sets
Mulhern, B., Feng, Y., Shah, K., Janssen, M. F., Herdman, M., van Hout, B., & Devlin, N. (2018) · PharmacoEconomics · doi:10.1007/s40273-018-0628-3 · Cited by 112
Suijkerbuijk, S., Nap, H. H., Cornelisse, L., IJsselsteijn, W. A., de Kort, Y. A. W., & Minkman, M. M. N. (2019) · Journal of Alzheimer s Disease · doi:10.3233/jad-190050 · Cited by 151
Parallel Valuation of the EQ-5D-3L and EQ-5D-5L by Time Trade-Off in Hungary
Rencz, F., Brodszky, V., Gulàcsi, L., Golicki, D., Ruzsa, G., Pickard, A. S., Law, E. H., & Péntek, M. (2020) · Value in Health · doi:10.1016/j.jval.2020.03.019 · Cited by 117
Umair, M., Chalabianloo, N., Sas, C., & Ersoy, C. (2021) · IEEE Access · doi:10.1109/access.2021.3052131 · Cited by 135
Kizilbash, A. M., Heinle, S. K., & Grayburn, P. A. (1998) · Circulation · doi:10.1161/01.cir.97.5.461 · Cited by 117
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.