STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 3,401–3,500 of 47,868
Six‐minute walk test in children and adolescents with cystic fibrosis
Cunha, M. T., Rozov, T., de Oliveira, R. C., & Jardim, J. R. (2006) · Pediatric Pulmonology · doi:10.1002/ppul.20308 · Cited by 133
Koktzoglou, I., & Li, D. (2006) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640600843413 · Cited by 122
Validation of the Arizona Activity Frequency Questionnaire using doubly labeled water
STATEN, L. K., TAREN, D. L., HOWELL, W. H., TOBAR, M., POEHLMAN, E. T., HILL, A., REID, P. M., & RITENBAUGH, C. (2001) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200111000-00024 · Cited by 117
Mu, J., Slevin, J. C., Qu, D., McCormick, S. M., & Adamson, S. L. (2008) · Reproductive Biology and Endocrinology · doi:10.1186/1477-7827-6-34 · Cited by 116
6-Minute walk distance in healthy North Africans older than 40 years: Influence of parity
Saad, H. B., PREFAUT, C. G., Tabka, Z., Mtir, A. H., Chemit, M., Hassaoune, R., Abid, T. B., Zara, K., Mercier, G., Zbidi, A., et al. (2008) · Respiratory Medicine · doi:10.1016/j.rmed.2008.07.023 · Cited by 132
Ruta, D. A., Garratt, A., CHADHA, Y. C., Flett, G. M. M., Hall, M. H., & Russell, I. T. (1995) · Quality of Life Research · doi:10.1007/bf00434381 · Cited by 116
Infratentorial atrophy on magnetic resonance imaging and disability in multiple sclerosis
Edwards, S. G. M., Gong, Q. Y., Liu, C., Zvartau, M. E., Jaspan, T., Roberts, N., & Blumhardt, L. D. (1999) · Brain · doi:10.1093/brain/122.2.291 · Cited by 126
Stauffer, M. E., Taylor, S. D., Watson, D. J., Peloso, P. M., & Morrison, A. (2011) · International Journal of Inflammation · doi:10.4061/2011/231926 · Cited by 115
Intraluminal abdominal aortic aneurysm thrombus is associated with disruption of wall integrity
Koole, D., Zandvoort, H. J. A., Schoneveld, A. H., Vink, A., Vos, J. A., van den Hoogen, L. L., de Vries, J. P. P. M., Pasterkamp, G., Moll, F. L., & van Herwaarden, J. A. (2012) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2012.07.003 · Cited by 127
NAGDYMAN, N., EWERT, P., PETERS, B., MIERA, O., FLECK, T., & BERGER, F. (2008) · Pediatric Anesthesia · doi:10.1111/j.1460-9592.2007.02365.x · Cited by 116
Lindner, E., & Pendley, B. D. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.11.022 · Cited by 135
Roeleveld, R. J., Marcus, J. T., Boonstra, A., Postmus, P. E., Marques, K. M., Bronzwaer, J. G. F., & Noordegraaf, A. V. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20338 · Cited by 116
A More Efficient Magnetic Resonance Imaging???Based Strategy for Measuring Quadriceps Muscle Volume
TRACY, B. L., IVEY, F. M., JEFFREY METTER, E., FLEG, J. L., SIEGEL, E. L., & HURLEY, B. F. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000053722.53302.d6 · Cited by 117
Vermehren, J., Kau, A., Gärtner, B. C., Göbel, R., Zeuzem, S., & Sarrazin, C. (2008) · Journal of Clinical Microbiology · doi:10.1128/jcm.00755-08 · Cited by 116
Verschuren, O. W., Takken, T., Ketelaar, M., Gorter, J. W., & Helders, P. J. M. (2007) · Pediatric Physical Therapy · doi:10.1097/pep.0b013e318036bfce · Cited by 119
Arch height change during sit‐to‐stand: an alternative for the navicular drop test
McPoil, T. G., Cornwall, M. W., Medoff, L., Vicenzino, B., Forsberg, K., & Hilz, D. (2008) · Journal of Foot and Ankle Research · doi:10.1186/1757-1146-1-3 · Cited by 116
Altman, D. G., & Royston, J. P. (1988) · Statistics in Medicine · doi:10.1002/sim.4780070602 · Cited by 112
Self-citationA comparison of self‐reported and measured height, weight and BMI in Australian adolescents
Wang, Z., Patterson, C. M., & Hills, A. P. (2002) · Australian and New Zealand Journal of Public Health · doi:10.1111/j.1467-842x.2002.tb00350.x · Cited by 132
Brouwer, S., Reneman, M. F., Dijkstra, P. U., Groothoff, J. W., Schellekens, J. M. H., & Göeken, L. N. H. (2003) · Journal of Occupational Rehabilitation · doi:10.1023/a:1026264519996 · Cited by 116
Portable measurement of maximum mouth pressures
Hamnegard, C., Wragg, S., Kyroussis, D., Aquilina, R., Moxham, J., & Green, M. (1994) · European Respiratory Journal · doi:10.1183/09031936.94.07020398 · Cited by 131
Method Comparison—A Different Approach
Pollock, M. A., Jefferson, S. G., Kane, J. W., Lomax, K., MacKinnon, G., & Winnard, C. B. (1992) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456329202900512 · Cited by 116
Martoglio, A.-M., Tom, B. D. M., Starkey, M. P., Corps, A. N., Charnock‐Jones, D. S., & Smith, S. K. (2000) · Molecular Medicine · doi:10.1007/bf03402191 · Cited by 131
Palka, P., Lange, A., Fleming, A., Fenn, L. N., Bouki, K. P., Shaw, T. R. D., Fox, K. A. A., McDicken, W. N., & Sutherland, G. R. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014977 · Cited by 116
Airway Wall Remodeling after Cessation of Exposure to Isocyanates in Sensitized Asthmatic Subjects
Saetta, M. P., Maestrelli, P., Turato, G., Mapp, C. E., Milani, G., Pivirotto, F., Fabbri, L. M., & Stefano, A. D. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.151.2.7842211 · Cited by 116
Retest Reliability of Recall Measures of Leisure-Time Physical Activity in Australian Adults
BOOTH, M. L., OWEN, N., BAUMAN, A. E., & GORE, C. J. (1996) · International Journal of Epidemiology · doi:10.1093/ije/25.1.153 · Cited by 116
Saeed, M., Bremerich, J., Wendland, M. F., Wyttenbach, R., Weinmann, H., & Higgins, C. B. (1999) · Radiology · doi:10.1148/radiology.213.1.r99se30247 · Cited by 116
Oger, E., Leroyer, C., Bressollette, L., Nonent, M., Moigne, E. L., Bizais, Y., Amiral, J., Grimaux, M., Clavier, J. B., Ill, P., et al. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.1.9710058 · Cited by 124
Arterial blood pressure monitoring in overweight critically ill patients: invasive or noninvasive?
Araghi, A., Bander, J. J., & Guzman, J. A. (2006) · Critical Care · doi:10.1186/cc4896 · Cited by 115
Eisenkölbl, J., Kartasurya, M., & Widhalm, K. (2001) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1601184 · Cited by 115
Flatt, A. A., & Esco, M. R. (2013) · Journal of Human Kinetics · doi:10.2478/hukin-2013-0071 · Cited by 115
Bouvy, W. H., Geurts, L. J., Kuijf, H. J., Luijten, P. R., Kappelle, L. J., Biessels, G. J., & Zwanenburg, J. J. M. (2015) · NMR in Biomedicine · doi:10.1002/nbm.3306 · Cited by 115
Sun, B., & Zhang, Z. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2473697 · Cited by 115
Rud, E., Klotz, D., Rennesund, K., Baco, E., Berge, V., Lien, D., Svindland, A., Lundeby, E., Berg, R. E., Eri, L. M., et al. (2014) · British Journal of Urology · doi:10.1111/bju.12637 · Cited by 115
Luo, N., Wang, P., Thumboo, J., Lim, Y.-W., & Vrijhoef, H. J. (2014) · PharmacoEconomics · doi:10.1007/s40273-014-0142-1 · Cited by 122
Miyasaka, Y., Tsujimoto, S., Maeba, H., Yuasa, F., Takehana, K., Dote, K., & Iwasaka, T. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.03.009 · Cited by 115
Measurement error and minimum detectable change in 4-meter gait speed in older adults
Goldberg, A., & Niemiec, S. L. S. (2011) · Aging Clinical and Experimental Research · doi:10.1007/bf03325236 · Cited by 126
Goffinet, C., Chenot, F., Robert, A. R., Pouleur, A., de Waroux, J. L. P., Vancrayenest, D., Gérard, O., Pasquet, A., Gerber, B. L., & Vanoverschelde, J. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn511 · Cited by 115
Shi, Y., Qiyong, G., Xia, F., Dzyubak, B., Glaser, K. J., Li, Q., Li, J., & Ehman, R. L. (2014) · Radiology · doi:10.1148/radiol.14132592 · Cited by 118
Validade de peso e estatura informados e índice de massa corporal: estudo pró-saúde
da Fonseca, M. D. J. M., Faerstein, E., Chor, D., & Lopes, C. D. S. (2004) · Revista de Saúde Pública · doi:10.1590/s0034-89102004000300009 · Cited by 165
Bezodis, N. E., Salo, A., & Trewartha, G. (2010) · Sports Biomechanics · doi:10.1080/14763141.2010.538713 · Cited by 128
Steenholdt, C., Ainsworth, M. A., Tovey, M. G., Klausen, T. W., Thomsen, O. Ø., Brynskov, J., & Bendtzen, K. (2013) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0b013e31828d23c3 · Cited by 124
Sharifi, I., Goudarzi, S., & Khodabakhshi, M. B. (2018) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2018.12.005 · Cited by 125
Comparative analyses of SPI and SPEI as drought assessment tools in Tigray Region, Northern Ethiopia
Tefera, A. S., Ayoade, J. O., & Bello, N. J. (2019) · SN Applied Sciences · doi:10.1007/s42452-019-1326-2 · Cited by 134
Intra- and Interobserver Variability in CT Measurements in Oncology
McErlean, A., Panicek, D. M., Zabor, E. C., Moskowitz, C. S., Bitar, R., Motzer, R. J., Hricak, H., & Ginsberg, M. S. (2013) · Radiology · doi:10.1148/radiol.13122665 · Cited by 115
Badby, A. J., Mundy, P. D., Comfort, P., Lake, J. P., & McMahon, J. J. (2023) · Sensors · doi:10.3390/s23104820 · Cited by 115
Svensson, T., Madhawa, K., Nt, H., Chung, U., & Svensson, A. K. (2024) · Sleep Medicine · doi:10.1016/j.sleep.2024.01.020 · Cited by 139
Mahoney, J. J., Vreman, H. J., Stevenson, D. K., & Kessel, A. L. V. (1993) · Clinical Chemistry · doi:10.1093/clinchem/39.8.1693 · Cited by 115
Curasan PRP kit vs. PCCS PRP system
Weibrich, G., & Kleis, W. K. G. (2002) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2002.130413.x · Cited by 115
Boyd, N. F., Martin, L. J., Gunasekara, A., Melnichouk, O., Maudsley, G., Peressotti, C., Yaffe, M. J., & Minkin, S. (2009) · Cancer Epidemiology Biomarkers & Prevention · doi:10.1158/1055-9965.epi-09-0107 · Cited by 125
In Vivo Analysis of Ciliary Muscle Morphologic Changes with Accommodation and Axial Ametropia
Sheppard, A. L., & Davies, L. N. (2010) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.10-5787 · Cited by 136
Meldrum, D., Shouldice, C., Conroy, R. M., Jones, K., & Forward, M. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2013.07.130 · Cited by 142
Reproducibility of Measurements of Cerebral Infarct Volume on CT Scans
van der Worp, H. B., Claus, S. P., Bär, P. R., Ramos, L. M. P., Algra, A., van Gijn, J., & Kappelle, L. J. (2001) · Stroke · doi:10.1161/01.str.32.2.424 · Cited by 115
Simulating pasture growth rates in Australian and New Zealand grazing systems
Cullen, B. R., Eckard, R., Callow, M. N., Johnson, I. R., Chapman, D. F., Rawnsley, R., Garcia, S. C., White, T., & Snow, V. O. (2008) · Australian Journal of Agricultural Research · doi:10.1071/ar07371 · Cited by 115
Lee, W. R., Roach, M., Michalski, J. M., Moran, B. J., & BEYER, D. C. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02950-4 · Cited by 115
Aortic Stenosis: Comparative Evaluation of 16–Detector Row CT and Echocardiography
Alkadhi, H., Wildermuth, S., Plass, A., Béttex, D., Baumert, B., Leschka, S., Desbiolles, L. M., Marinček, B., & Boehm, T. (2006) · Radiology · doi:10.1148/radiol.2393050458 · Cited by 115
Wang, T., Wang, M., Fung, J. W., Yip, G. W., Zhang, Y., Ho, P. P. Y., Tse, D. M. K., Yu, C., & Sanderson, J. E. (2006) · International Journal of Cardiology · doi:10.1016/j.ijcard.2006.01.051 · Cited by 115
MacIntyre, U. E., Venter, C., & Vorster, H. (2001) · Public Health Nutrition · doi:10.1079/phn200041 · Cited by 137
Cardim, N. M., Oliveira, A. G., Longo, S., Ferreira, T. C., Pereira, A., dos Reis, R. P., & Correia, J. M. (2003) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2003.13 · Cited by 124
McMahon, A. D. (2003) · Pharmacoepidemiology and Drug Safety · doi:10.1002/pds.883 · Cited by 114
Haberer, J. E., Cook, A. D., Walker, A. S., Ngambi, M., Ferrier, A., Mulenga, V., Kityo, C. M., Thomason, M. J., Kabamba, D., Chintu, C., et al. (2011) · PLoS ONE · doi:10.1371/journal.pone.0018505 · Cited by 139
Patient centred assessment of quality of life for patients with four common conditions.
Ruta, D. A., Garratt, A., & Russell, I. T. (1999) · BMJ Quality & Safety · doi:10.1136/qshc.8.1.22 · Cited by 130
Evaluation of 2 new optical biometry devices and comparison with the current gold standard biometer
Chen, Y., Hirnschall, N. D., & Findl, O. (2011) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2010.10.041 · Cited by 115
Clairotte, C., Retout, S., Potier, L., Roussel, R., & Escoubet, B. (2009) · Diabetes Care · doi:10.2337/dc08-2230 · Cited by 137
Assessment of published reliability studies for cervical spine range-of-motion measurement tools
Jordan, K. P. (2000) · Journal of Manipulative and Physiological Therapeutics · doi:10.1016/s0161-4754(00)90248-3 · Cited by 117
Factors affecting a mother's recall of her baby's birth weight
Tate, A. R., Dezateux, C., Cole, T. J., & Davidson, L. (2005) · International Journal of Epidemiology · doi:10.1093/ije/dyi029 · Cited by 115
Validity, Practical Utility, and Reliability of the activPAL™ in Preschool Children
DAVIES, G., REILLY, J. J., MCGOWAN, A. J., DALL, P. M., GRANAT, M. H., & PATON, J. Y. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31823b1dc7 · Cited by 116
Ibaraki, M., Miura, S., Shimosegawa, E., Sugawara, S., Mizuta, T., Ishikawa, A., & Amano, M. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.044008 · Cited by 115
A common reference frame for describing rotation of the distal femur
Victor, J. M. K., Doninck, D. V., Labey, L., Glabbeek, F. V., Parizel, P. M., & Bellemans, J. (2009) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.91b5.21827 · Cited by 115
Schoenberg, S. O., Rieger, J., Weber, C. H., Michaely, H. J., Waggershauser, T., Ittrich, C., Dietrich, O., & Reiser, M. F. (2005) · Radiology · doi:10.1148/radiol.2352031693 · Cited by 115
Langendonk, J. G. (1998) · Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.83.5.1706 · Cited by 117
Induced sputum to assess airway inflammation: a study of reproducibility
Spanevello, A., Migliori, G. B., Sharara, A. M., BALLARDlNI, L., BRIDGE, P., PISATT, P., Neri, M., & Ind, P. W. (1997) · Clinical & Experimental Allergy · doi:10.1111/j.1365-2222.1997.tb01150.x · Cited by 115
Left ventricular volume estimation for real-time three-dimensional echocardiography
Corsi, C., Saracino, G., Sarti, A., & Lamberti, C. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.804418 · Cited by 115
Jet and ultrasonic nebuliser output: use of a new method for direct measurement of aerosol output.
Dennis, J., Stenton, S., Beach, J. R., Avery, A. J., Walters, E. H., & Hendrick, D. J. (1990) · Thorax · doi:10.1136/thx.45.10.728 · Cited by 115
One-Step Enzyme-Linked Immunosorbent Assay (ELISA) for Plasma Fatty Acid-Binding Protein
Wodzig, K. W. H., Pelsers, M. M. A. L., van der Vusse, G. J., Roos, W., & Glatz, J. F. C. (1997) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456329703400307 · Cited by 115
Intramyocardial Transplantation of Autologous Myoblasts
Pouzet, B., Vilquin, J., Hagège, A. A., Scorsin, M., Messas, E., Fiszman, M. Y., Schwartz, K., & Menasché, P. (2000) · Circulation · doi:10.1161/01.cir.102.suppl_3.iii-210 · Cited by 115
Pandia, K., Inan, O. T., Kovacs, G. T. A., & Giovangrandi, L. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/10/1643 · Cited by 114
Park, J.-H., Park, Y. S., Kim, Y. J., Lee, I. S., Kim, J. H., Lee, J.-H., Choi, S. W., Jeong, J.-O., & Seong, I.-W. (2010) · Journal of Cardiovascular Ultrasound · doi:10.4250/jcu.2010.18.4.121 · Cited by 114
A meta‐analysis of the accuracy and precision of the ultrasonic cardiac output monitor (USCOM)
Chong, S. W., & Peyton, P. J. (2012) · Anaesthesia · doi:10.1111/j.1365-2044.2012.07311.x · Cited by 118
de Visser, S. K., Bowden, J. C., Wentrup-Byrne, E., Rintoul, L., Bostrom, T., Pope, J. M., & Momot, K. I. (2008) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2007.09.015 · Cited by 114
Xie, X., Zhang, X., Fu, J., Wang, H., Jonas, J. B., Peng, X., Tian, G., Xian, J., Ritch, R. H., Li, L., et al. (2013) · Critical Care · doi:10.1186/cc12841 · Cited by 114
Heye, T. J., Davenport, M. S., Horvath, J. J., Feuerlein, S., Breault, S. R., Bashir, M. R., Merkle, E. M., & Boll, D. T. (2012) · Radiology · doi:10.1148/radiol.12120278 · Cited by 114
Bandyopadhyay, A. (2014) · Biology of Sport · doi:10.5604/20831862.1127283 · Cited by 122
Optical Vibrocardiography: A Novel Tool for the Optical Monitoring of Cardiac Activity
Morbiducci, U., Scalise, L., Melis, M. D., & Grigioni, M. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9202-9 · Cited by 115
Length Determination in Midshaft Clavicle Fractures: Validation of Measurement
Smekal, V., Deml, C., Irenberger, A., Niederwanger, C., Lutz, M., Blauth, M., & Krappinger, D. (2008) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0b013e318178d97d · Cited by 114
Tsantis, S., Kagadis, G. C., Katsanos, K. H., Karnabatidis, D., Bourantas, G. C., & Nikiforidis, G. C. (2011) · Medical Physics · doi:10.1118/1.3673067 · Cited by 124
Seibold, L. K., Mandava, N., & Kahook, M. Y. (2010) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2010.06.024 · Cited by 114
Keřkovský, M., Bednařík, J., Dušek, L., Šprláková‐Puková, A., Urbánek, I., Mechl, M., Válek, V., & Kadaňka, Z. (2011) · Spine · doi:10.1097/brs.0b013e31820e6c35 · Cited by 127
Landberg, R., Åman, P., Friberg, L. E., Vessby, B. O., Adlercreutz, H., & Kamal‐Eldin, A. (2008) · American Journal of Clinical Nutrition · doi:10.3945/ajcn.2008.26709 · Cited by 116
Sánchez-Cano, A. I., Orduna, E., Segura, F. J., FUENTE, C. L. D. L., Cuenca, N., Abecia, E., & Pinilla, I. (2014) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2014.05.035 · Cited by 114
Lohman, M., Tallroth, K., Kettunen, J. A., & Marttinen, M. T. (2009) · Metabolism · doi:10.1016/j.metabol.2009.05.023 · Cited by 139
Body mass index and cognitive function: the potential for reverse causation
Suemoto, C. K., Gilsanz, P., Mayeda, E. R., & Glymour, M. M. (2015) · International Journal of Obesity · doi:10.1038/ijo.2015.83 · Cited by 131
Reproducibility of the Nicotine Metabolite Ratio in Cigarette Smokers
St.Helen, G., Novalen, M., Heitjan, D. F., Dempsey, D., Jacob, P., Aziziyeh, A., Wing, V. C., George, T. P., Tyndale, R. F., & Benowitz, N. L. (2012) · Cancer Epidemiology, Biomarkers & Prevention · doi:10.1158/1055-9965.epi-12-0236 · Cited by 113
Soliman, O. I. I., Kirschbaum, S. W., van Dalen, B. M., van der Zwaan, H. B., Delavary, B. M., Vletter, W. B., van Geuns, R., ten Cate, F. J., & Geleijnse, M. L. (2008) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2008.04.062 · Cited by 114
Lieshout, E. M. M. V., Boer, A. S. D., Meuffels, D. E., den Hoed, P. T., van der Vlies, C. H., Tuinebreijer, W. E., & Verhofstad, M. H. J. (2017) · BMJ Open · doi:10.1136/bmjopen-2016-012884 · Cited by 118
Standardized Approach for ROI-Based Measurements of Proton Density Fat Fraction and R2* in the Liver
Campo, C. A., Hernando, D., Schubert, T., Bookwalter, C. A., Pay, A. J. V., & Reeder, S. B. (2017) · American Journal of Roentgenology · doi:10.2214/ajr.17.17812 · Cited by 112
Influence of Coronary Calcium on Diagnostic Performance of Machine Learning CT-FFR
Tesche, C., Otani, K., Cecco, C. N. D., Coenen, A., Geer, J. D., Kruk, M. B. P., Kim, Y., Albrecht, M. H., Baumann, S., Renker, M., et al. (2019) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2019.06.027 · Cited by 117
Cano‐Barbacil, C., Radinger, J., Argudo, M., Rubio‐Gracia, F., Vila‐Gispert, A., & García‐Berthou, E. (2020) · Scientific Reports · doi:10.1038/s41598-020-75974-x · Cited by 138
AngioNet: a convolutional neural network for vessel segmentation in X-ray angiography
Iyer, K., Najarian, C., Fattah, A., Arthurs, C. J., Soroushmehr, S. M. R., Subban, V., Sankardas, M. A., Nadakuditi, R. R., Nallamothu, B. K., & Figueroa, C. A. (2021) · Scientific Reports · doi:10.1038/s41598-021-97355-8 · Cited by 132
Valbuena, V. S. M., Barbaro, R. P., Claar, D., Valley, T. S., Dickson, R. P., Gay, S. E., Sjoding, M. W., & Iwashyna, T. J. (2022) · Chest · doi:10.1016/j.chest.2021.09.025 · Cited by 119
Clinical Validation of a Virtual Planner for Coronary Interventions Based on Coronary CT Angiography
Sonck, J., Nagumo, S., Nørgaard, B. L., Otake, H., Ko, B. S. H., Zhang, J., Mizukami, T., Mæng, M., Andreini, D., Takahashi, Y., et al. (2022) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2022.02.003 · Cited by 114
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.