STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 3,601–3,700 of 47,868
Frydrychowicz, A. P., Markl, M., Hirtler, D., Harloff, A., Schlensak, C., Geiger, J., Stiller, B., & Arnold, R. (2011) · Investigative Radiology · doi:10.1097/rli.0b013e3182034fc2 · Cited by 131
Validation of the PDPAR as an Adolescent Diary: Effect of Accelerometer Cut Points
Anderson, C. B., Hagströmer, M., & Yngve, A. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000170073.57440.df · Cited by 140
Reproducibility of metabolite peak areas in 1H MRS of brain
Marshall, I., Wardlaw, J. M., Cannon, J., Slattery, J., & Sellar, R. J. (1996) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(95)02084-7 · Cited by 112
Agreement Between Bedside Blood and Plasma Glucose Measurement in the ICU Setting
Finkielman, J. D., Oyen, L. J., & Afessa, B. (2005) · CHEST Journal · doi:10.1378/chest.127.5.1749 · Cited by 112
Kwartz, A., Henson, D., Harper, R., Spencer, A., & McLeod, D. (2005) · Health Technology Assessment · doi:10.3310/hta9460 · Cited by 110
Itoh, K. (2003) · Annals of Nuclear Medicine · doi:10.1007/bf03006669 · Cited by 112
Capillary versus venous bedside blood glucose estimations
Boyd, R. (2005) · Emergency Medicine Journal · doi:10.1136/emj.2003.011619 · Cited by 112
Matthan, N. R., Ip, B. C., Resteghini, N. A., Ausman, L. M., & Lichtenstein, A. H. (2010) · Journal of Lipid Research · doi:10.1194/jlr.d007534 · Cited by 118
Allen, P. M., Radhakrishnan, H., & O'Leary, D. J. (2003) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2003.tb01625.x · Cited by 112
Daghini, E., Primak, A. N., Chade, A., Krier, J. D., Zhu, X.-Y., Ritman, E. L., McCollough, C. H., & Lerman, L. O. (2007) · Radiology · doi:10.1148/radiol.2432060655 · Cited by 112
Maceira, A. M., Cosín-Sales, J., Roughton, M., Prasad, S. K., & Pennell, D. J. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-29 · Cited by 114
A comparison of salivary testosterone measurement using immunoassays and tandem mass spectrometry
Welker, K. M., Lassetter, B., Brandes, C. M., Prasad, S., Koop, D. R., & Mehta, P. H. (2016) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2016.05.022 · Cited by 117
Belardinelli, R., Ciampani, N., Costantini, C., Blandini, A., & Purcaro, A. (1996) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)89153-9 · Cited by 113
Bloomer, T. N., Plein, S., Radjenovic, A., Higgins, D. M., Jones, T. R., Ridgway, J. P., & Sivananthan, M. U. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10019 · Cited by 118
Grude, M., Juergens, K. U., Wichter, T., Paul, M., Fallenberg, E. M., Müller, J. G., Heindel, W. L., Breithardt, G., & Fischbach, R. (2003) · Investigative Radiology · doi:10.1097/01.rli.0000077070.40713.76 · Cited by 124
Intraobserver and interobserver agreement in anal endosonography
Gold, D. M., Halligan, S., Kmiot, W. A., & Bartram, C. I. (1999) · British journal of surgery · doi:10.1046/j.1365-2168.1999.01032.x · Cited by 112
Greher, M., Retzl, G., Niel, P., Kamolz, L., Marhofer, P., & Kapral, S. (2002) · British Journal of Anaesthesia · doi:10.1093/bja/88.5.632 · Cited by 112
Real-time three-dimensional echocardiography for measurement of left ventricular volumes
Schmidt, M. A., Ohazama, C. J., Agyeman, K. O., Freidlin, R. Z., Jones, M., Laurienzo, J. M., Brenneman, C. L., Arai, A. E., von Ramm, O. T., & Panza, J. A. (1999) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)00591-3 · Cited by 112
Matias, C. N., Santos, D. A., Júdice, P. B., Magalhães, J. P., Minderico, C. S., Fields, D. A., Lukaski, H. C., Sardinha, L. B., & Silva, A. M. (2016) · Clinical Nutrition · doi:10.1016/j.clnu.2015.03.013 · Cited by 111
Estimating respiratory frequency from autoregressive spectral analysis of heart period.
Thayer, J. F., Sollers, J. J., Ruiz-Padial, E., & Vila, J. (2002) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2002.1032638 · Cited by 111
Lanatà, A., Scilingo, E. P., Nardini, E., Loriga, G., Paradiso, R., & De-Rossi, D. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2037614 · Cited by 111
The Computer-Vision Symptom Scale (CVSS17): Development and Initial Validation
González‐Pérez, M., García, R. S., Antona, B., Barrio, A. R., & González-Romero, E. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.13-13818 · Cited by 130
A holistic measurement model of movement competency in children
Rudd, J. R., Butson, M. L., Barnett, L. M., Farrow, D., Berry, J., Borkoles, E., & Polman, R. C. J. (2015) · Journal of Sports Sciences · doi:10.1080/02640414.2015.1061202 · Cited by 133
Wong, W. W., Hergenroeder, A. C., Stuff, J. E., Butte, N. F., Smith, E. O., & Ellis, K. J. (2002) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/76.2.384 · Cited by 124
Comparison of three hand dynamometers in relation to the accuracy and precision of the measurements
Amaral, J. F., Mancini, M., & Novo Júnior, J. M. (2012) · Brazilian Journal of Physical Therapy · doi:10.1590/s1413-35552012000300007 · Cited by 110
EL-Khuffash, A. F., Jain, A., Dragulescu, A., McNamara, P. J., & Mertens, L. (2012) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2012.07.016 · Cited by 111
Gaipa, G., Cazzaniga, G., Valsecchi, M. G., Panzer‐Grümayer, R., Buldini, B., Silvestri, D., Karawajew, L., Maglia, O., Ratei, R., Benetello, A., et al. (2012) · Haematologica · doi:10.3324/haematol.2011.060426 · Cited by 111
deiteren, A., camilleri, M., bharucha, A. E., burton, D., mckinzie, S., rao, A. S., & zinsmeister, A. R. (2010) · Neurogastroenterology & Motility · doi:10.1111/j.1365-2982.2009.01441.x · Cited by 111
McGee, W. T., Horswell, J. L., Calderon, J., Janvier, G., Severen, T. V., den Berghe, G. V., & Kozikowski, L. (2007) · Critical Care · doi:10.1186/cc6125 · Cited by 119
Deh, K., Nguyen, T. D., Eskreis‐Winkler, S., Prince, M. R., Spincemaille, P., Gauthier, S., Kovanlikaya, I., Zhang, Y., & Wang, Y. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24943 · Cited by 108
The effect of topical atropine on the choroidal thickness of healthy children
Zhang, Z., Zhou, Y., Xie, Z., Chen, T., Gu, Y., Lu, S., & Wu, Z. (2016) · Scientific Reports · doi:10.1038/srep34936 · Cited by 111
Chinoy, E. D., Cuellar, J. A., Jameson, J., & Markwald, R. R. (2022) · Nature and Science of Sleep · doi:10.2147/nss.s348795 · Cited by 130
Camparini, M., Cassinari, P., Ferrigno, L., & Macaluso, C. (2001) · PubMed · Cited by 111
Martell, J. M., Berkson, E. M., Berger, R. A., & Jacobs, J. J. (2003) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200306000-00020 · Cited by 111
The Effect of Posterior Capsule Opacification on Visual Function
Meacock, W. R., Spalton, D. J., Boyce, J. F., & Marshall, J. (2003) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.02-0634 · Cited by 111
Simplified Resting Metabolic Rate—Predicting Formulas for Normal‐Sized and Obese Individuals
Livingston, E. H., & Kohlstadt, I. (2005) · Obesity Research · doi:10.1038/oby.2005.149 · Cited by 120
Hyperalgesia in a human model of acute inflammatory pain: a methodological study
Pedersen, J. L., & Kehlet, H. (1998) · Pain · doi:10.1016/s0304-3959(97)00160-7 · Cited by 123
Reliability Study of Measurements for Lymphedema in Breast Cancer Patients
Chen, Y.-W. R., Tsai, H.-J., Hung, H.-C., & Tsauo, J. (2008) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e31815b6199 · Cited by 113
Schwarz, C., Mitterbauer, C., Boczula, M., Maca, T., Funovics, M. A., Heinze, G., Lorenz, M., Kovařík, J., & Oberbauer, R. W. (2003) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(03)00786-8 · Cited by 111
Newgard, C. D. (2006) · Academic Emergency Medicine · doi:10.1197/j.aem.2005.09.011 · Cited by 118
DAVIES, L. C., FRANCIS, D. P., JURÁK, P., KÁRA, T., PIEPOLI, M., & COATS, A. J. S. (1999) · Clinical Science · doi:10.1042/cs0970515 · Cited by 112
Faucher, M., Poiraudeau, S., Lefèvre‐Colau, M., Rannou, F., Fermanian, J., & Revel, M. (2004) · Joint Bone Spine · doi:10.1016/s1297-319x(03)00112-x · Cited by 125
Shlipak, M. G., Lyons, W. L., Go, A. S., Chou, T. M., Evans, G. T., & Browner, W. S. (1999) · JAMA · doi:10.1001/jama.281.8.714 · Cited by 111
Periodontal disease and perinatal outcomes: a case‐control study
Bassani, D. G., Olinto, M. T. A., & Kreiger, N. (2006) · Journal Of Clinical Periodontology · doi:10.1111/j.1600-051x.2006.01012.x · Cited by 138
Patel, J., Marks, K. A., Roberts, I. G., Azzopardi, D., & Edwards, A. D. (1998) · Pediatric Research · doi:10.1203/00006450-199801000-00006 · Cited by 111
The multiple sclerosis functional composite: different practice effects in the three test components
Solari, A., Radice, D., Manneschi, L., Motti, L., & Montanari, E. (2004) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2004.09.033 · Cited by 126
Grotle, M., Vøllestad, N. K., & Brox, J. I. (2006) · The Clinical Journal of Pain · doi:10.1097/01.ajp.0000208243.33498.cb · Cited by 112
Madsen, R. K., Jensen, T. S., Pope, M. H., Sørensen, J. S., & Bendix, T. (2008) · Spine · doi:10.1097/brs.0b013e31815e395f · Cited by 113
Imaging the Urethral Sphincter With Three-Dimensional Ultrasound
Athanasiou, S., Khullar, V., Boos, K., Salvatore, S., & Cardozo, L. (1999) · Obstetrics and Gynecology · doi:10.1016/s0029-7844(99)00247-1 · Cited by 111
Reliability of Measuring Forward Head Posture in a Clinical Setting
Garrett, T. R., Youdas, J. W., & Madson, T. J. (1993) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.1993.17.3.155 · Cited by 111
The heat/capsaicin sensitization model: A methodologic study
Dirks, J., Petersen, K. L., & Dahl, J. B. (2003) · Journal of Pain · doi:10.1054/jpai.2003.10 · Cited by 111
Comparison of Body Composition Analysis Methods in Clinical Routine
Erselcan, T., Candan, F., Saruhan, S., & Ayca, T. (2000) · Annals of Nutrition and Metabolism · doi:10.1159/000046691 · Cited by 134
Comparison of Two Clinical Bleb Grading Systems
Wells, A. P., Ashraff, N., Hall, R. C., & Purdie, G. (2006) · Ophthalmology · doi:10.1016/j.ophtha.2005.06.037 · Cited by 111
Reinders, A., Cuckson, A. C., Lee, J. T. M., & Shennan, A. H. (2005) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2005.00617.x · Cited by 111
Validity of Transdermal Alcohol Monitoring: Fixed and Self‐Regulated Dosing
Sakai, J. T., Mikulich‐Gilbertson, S. K., Long, R. J., & Crowley, T. J. (2006) · Alcoholism: Clinical and Experimental Research · doi:10.1111/j.1530-0277.2006.00004.x · Cited by 111
Gender differences in wall shear–mediated brachial artery vasoconstriction and vasodilation
Levenson, J. A., Pessana, F., Gariépy, J., Armentano, R. L., & Simon, A. C. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01604-7 · Cited by 111
TUNEL assay and SCSA determine different aspects of sperm DNA damage
Henkel, R., Hoogendijk, C. F., Bouic, P. J., & Kruger, T. F. (2010) · Andrologia · doi:10.1111/j.1439-0272.2009.01002.x · Cited by 120
Bel‐Serrat, S., Mouratidou, T., Pala, V. M., Huybrechts, I., Börnhorst, C., Fernández-Alvira, J. M., Hadjigeorgiou, C., Eiben, G., Hebestreit, A., Lissner, L., et al. (2013) · Public Health Nutrition · doi:10.1017/s1368980012005368 · Cited by 135
Plein, S., Kozerke, S., Sürder, D., Lüscher, T. F., Greenwood, J. P., Boesiger, P., & Schwitter, J. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn297 · Cited by 123
Brock, C., Young, H. E., O'Reilly, S. M., Matthews, J. C., Osman, S., Evans, H. S., Newlands, E. S., & Price, P. (2000) · British Journal of Cancer · doi:10.1054/bjoc.1999.0971 · Cited by 113
Yuan, C., Lin, E., Millard, J., & Hwang, J. (1999) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(98)00162-3 · Cited by 111
Quantification of free water transport in peritoneal dialysis
Smit, W., Struijk, D. G., Ho-dac-Pannekeet, M. M., & Krediet, R. T. (2004) · Kidney International · doi:10.1111/j.1523-1755.2004.00815.x · Cited by 118
Schütz, E., Svinarov, D. A., Shipkova, M., Niedmann, P.-D., Armstrong, V. W., Wieland, E., & Oellerich, M. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.10.2158 · Cited by 111
Nicotine impairs endothelium‐dependent dilatation in human veins in vivo
Chalon, S., Moreno, H., Benowitz, N., Hoffman, B. B., & Blaschke, T. F. (2000) · Clinical pharmacology and therapy · doi:10.1067/mcp.2000.105153 · Cited by 121
Dirksen, M. S., Bax, J. J., Roos, A., Jukema, J. W., van der Geest, R. J., Geleijns, K., Boersma, E. H., van der Wall, E. E., & Lamb, H. J. (2002) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)02789-3 · Cited by 111
Cowburn, A. S., Holgate, S. T., & Sampson, A. P. (1999) · The Journal of Immunology · doi:10.4049/jimmunol.163.1.456 · Cited by 121
Ramsay, S., & Gomersall, C. D. (2002) · Anaesthesia · doi:10.1046/j.1365-2044.2002.265813.x · Cited by 111
Matsuoka, S., Kurihara, Y., Yagihashi, K., Hoshino, M., & Nakajima, Y. (2008) · Radiology · doi:10.1148/radiol.2491071650 · Cited by 123
Fayad, F., Lefèvre‐Colau, M., Gautheron, V., Macé, Y., Fermanian, J., Mayoux-Benhamou, A., Rören, A., Rannou, F., Roby-Brami, A., Revel, M., et al. (2008) · Manual Therapy · doi:10.1016/j.math.2008.01.013 · Cited by 128
Detection Rate, Location, and Size of Pulmonary Nodules in Trimodality PET/CT-MR
Stolzmann, P., Veit‐Haibach, P., Chuck, N. C., Rossi, C., Frauenfelder, T., Alkadhi, H., von Schulthess, G. K., & Boss, A. (2012) · Investigative Radiology · doi:10.1097/rli.0b013e31826f2de9 · Cited by 110
Thickness of softened human enamel removed by toothbrush abrasion: an in vitro study
Voronets, J., & Lussi, A. (2009) · Clinical Oral Investigations · doi:10.1007/s00784-009-0288-y · Cited by 110
Gordon, M. A., Kankwatira, A. M. K., Mwafulirwa, G., Walsh, A. L., Hopkins, M. J., Parry, C. M., Faragher, E. B., Zijlstra, E. E., Heyderman, R. S., & Molyneux, M. E. (2010) · Clinical Infectious Diseases · doi:10.1086/651080 · Cited by 111
Reliability of Handgrip Strength Test in Basketball Players
Gerodimos, V. (2012) · Journal of Human Kinetics · doi:10.2478/v10078-012-0003-y · Cited by 115
Noninvasive method to estimate anaerobic threshold in individuals with type 2 diabetes
Sales, M. M., Campbell, C. S. G., Morais, P. K., Ernesto, C., Soares-Caldeira, L. F., Russo, P., Motta, D. F., Moreira, S. R., Nakamura, F. Y., & Simões, H. G. (2011) · Diabetology & Metabolic Syndrome · doi:10.1186/1758-5996-3-1 · Cited by 110
Barg, A., Amendola, R. L., Henninger, H. B., Kapron, A. L., Saltzman, C. L., & Anderson, A. E. (2015) · Foot & Ankle International · doi:10.1177/1071100715591091 · Cited by 111
Donath, L., Faude, O., Lichtenstein, E., Nüesch, C., & Mündermann, A. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0115-z · Cited by 110
Reliability and Validity of the PAQ ‐C Questionnaire to Assess Physical Activity in Children
Benítez‐Porres, J., Fernández, I. L., Raya, J. F., Carnero, S. Á., Alvero‐Cruz, J. R., & Carnero, E. Á. (2016) · Journal of School Health · doi:10.1111/josh.12418 · Cited by 143
Repeated testing for the assessment of individual response to exercise training
Hecksteden, A., Pitsch, W., Rosenberger, F., & Meyer, T. (2018) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00896.2017 · Cited by 109
A new conception of visual aesthetic sensitivity
Corradi, G. B., Chuquichambi, E. G., Barrada, J. R., Clemente, A., & Nadal, M. (2019) · British Journal of Psychology · doi:10.1111/bjop.12427 · Cited by 128
Kop, W. J., Krantz, D. S., Howell, R. H., Ferguson, M. A., Papademetriou, V., Lu, D., Popma, J. J., Quigley, J. F., Vernalis, M., & Gottdiener, J. S. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01136-6 · Cited by 113
Key factors in the subjective and objective assessment of conjunctival erythema.
PAPAS, E. B. (2000) · PubMed · Cited by 110
Hwang, J. C., Chan, J. W. K., Chang, S., & Smith, R. T. (2006) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.05-1027 · Cited by 116
Validity of Self-Reported Measures of Workplace Sitting Time and Breaks in Sitting Time
CLARK, B. K., THORP, A. A., A.H. WINKLER, E., GARDINER, P. A., HEALY, G. N., OWEN, N., & DUNSTAN, D. W. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31821820a2 · Cited by 109
The reliability of knee joint position testing using electrogoniometry
Piriyaprasarth, P., Morris, M. E., Winter, A., & Bialocerkowski, A. (2008) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-9-6 · Cited by 110
Rotational Malalignment of the Tibia Following Reamed Intramedullary Nail Fixation
Puloski, S. K. T., Romano, C., Buckley, R., & Powell, J. (2004) · Journal of Orthopaedic Trauma · doi:10.1097/00005131-200408000-00001 · Cited by 110
Chen, F. K., Yeoh, J., Rahman, W., Patel, P. J., Tufail, A., & da Cruz, L. (2012) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.11-8771 · Cited by 110
The relationship of intraocular pressure to intracranial pressure
Lashutka, M. K., Chandra, A. B., Murray, H. N., Phillips, G. S., & Hiestand, B. C. (2004) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2003.12.006 · Cited by 119
Gietema, H. A., Wang, Y., Xu, D., van Klaveren, R. J., de Koning, H. J., Scholten, E. T., Verschakelen, J., Kohl, G., Oudkerk, M., & Prokop, M. (2006) · Radiology · doi:10.1148/radiol.2411050860 · Cited by 110
Determining Gestational Age in a Low-resource Setting: Validity of Last Menstrual Period
Darmstadt, G. L., Rosenberg, R. E., Ahmed, A. N. U., Ahmed, S., Saha, S. K., Chowdhury, M. A., Black, R. E., & Santosham, M. (2009) · Journal of Health, Population and Nutrition · doi:10.3329/jhpn.v27i3.3375 · Cited by 110
Three-dimensional ultrasound device for rapid determination of bladder volume
Marks, L. S., Dorey, F. J., Macairan, M. L., Park, C., & deKernion, J. B. (1997) · Urology · doi:10.1016/s0090-4295(97)00293-8 · Cited by 110
Gosselink, A. T. M., Blanksma, P. K., Crijns, H. J. G. M., Gelder, I. C. V., de Kam, P., Hillege, H. L., Niemeijer, M. G., Lie, K. I., & MEIJLER, F. L. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00340-1 · Cited by 110
Individual Smallest Detectable Difference in Bone Mineral Density Measurements
Ravaud, P., Reny, J., Giraudeau, B., Porcher, R., Dougados, M., & Roux, C. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.8.1449 · Cited by 110
High inter-tester reliability of the new mobility score in patients with hip fracture
Kristensen, M. T., Bandholm, T., Foss, N. B., Ekdahl, C. S., & Kehlet, H. (2008) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-0217 · Cited by 111
Guermazi, M., Poiraudeau, S., Yahia, M., Mezganni, M., Fermanian, J., Elleuch, M. H., & Revel, M. (2004) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2004.02.006 · Cited by 124
Measurement of visceral adipose tissue by DXA combined with anthropometry in obese humans
Bertin, É., Marcus, C. D., Ruiz, J., Eschard, J.-P., & Leuténegger, M. (2000) · International Journal of Obesity · doi:10.1038/sj.ijo.0801121 · Cited by 131
Thumboo, J., Chew, L.-H., & Soh, C.-H. (2001) · Osteoarthritis and Cartilage · doi:10.1053/joca.2000.0410 · Cited by 124
The Reliability and Validity of McMonnies Dry Eye Index
Nichols, K. K., Nichols, J. J., & Mitchell, G. L. (2004) · Cornea · doi:10.1097/00003226-200405000-00010 · Cited by 130
Ability of Different Physical Activity Monitors to Detect Movement During Treadmill Walking
Leenders, N. Y., Nelson, T. E., & Sherman, W. M. (2003) · International Journal of Sports Medicine · doi:10.1055/s-2003-37196 · Cited by 110
Sievers, B., Elliott, M. D., Hurwitz, L. M., Albert, T. S. E., Klem, I., Rehwald, W. G., Parker, M. A., Judd, R. M., & Kim, R. J. (2007) · Circulation · doi:10.1161/circulationaha.106.635409 · Cited by 110
Hart, E. C., Joyner, M. J., Wallin, B. G., Karlsson, T., Curry, T. B., & Charkoudian, N. (2010) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00924.2009 · Cited by 111
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.