In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 44,401–44,500 of 47,868
Emerging Methodology of Intraoperative Hemodynamic Monitoring Research
Fujimoto, Y., Alexander, B., Stark, B., & Cannesson, M. P. (2016) · Current anesthesiology reports · doi:10.1007/s40140-016-0176-3
Ultrasonography of the fetal face in the second and third trimester of pregnancy
de Jong-Pleij, E. (2013)
Energy utilisation of infants in Southern Brazil
Haisma, H. H. (2004)
Respiratory symptoms and lung function in pig farmers
Laasonen, K. (2006) · Tampere University Institutional Repository (Tampere University)
Gemiddeld Verschil Tussen Gepaarde Waarnemingen
Schouten, H. J. A. (1999) · Bohn Stafleu van Loghum eBooks · doi:10.1007/978-90-313-9661-0_5
Renal Arterial Blood Flow Quantification by Breath-held Phase-velocity Encoded MRI
Wallin, A. K. (2004) · UPT. Syiah Kuala University Library (Syiah Kuala University)
Monitoring of Cardiac Output and Its Derivatives
Giraud, R., & Bendjelid, K. (2016) · Springer eBooks · doi:10.1007/978-3-319-29430-8_2
8.2. Biopara-Milk: a whole cow simulation model for the prediction of rumen pH
Ambriz-Vilchis, V., Fawcett, R. H., Shaw, D. J., Macrae, A., & JESSOP, N. S. (2015) · Wageningen Academic Publishers eBooks · doi:10.3920/978-90-8686-815-5_35
Demystification of commonly used measurements in paediatrics
Bekhof, J. (2014) · University of Groningen research database (University of Groningen / Centre for Information Technology)
- Applications: Image Alignment
El-Baz, A. S., Gimel’farb, G., & Suri, J. S. (2015) · CRC Press eBooks · doi:10.1201/b19253-9
Gomez, E. P. (2012) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
Hardin, J. W., & Hilbe, J. M. (2012) · Chapman & Hall/CRC eBooks · doi:10.1201/b13880-7
Tulloh, R. M. R., Razavi, R., Johnson, R. I., Andriantsimiavona, R., Taylor, A. M., Baker, E. J., Muthurangu, V., Atkinson, D., Maxime Sermesant, B., & Miquel, M. E. (2016)
Jones, M. R., Blanch, P. B., & Rimes, J. R. (1993) · Respiratory Care · doi:10.1177/194336549303800807 · Cited by 1
MONITORING IN THE INTENSIVE CARE UNIT
Lewis, I. H., & O’Sullivan, B. (1994) · Anesthesiology Clinics of North America · doi:10.1016/s0889-8537(21)00709-4
Vallejo, B., & Juan, E. S. (2012) · TDX (Tesis Doctorals en Xarxa)
Reliability and Measurement Error
Newman, T. B., & Kohn, M. A. (2020) · Cambridge University Press eBooks · doi:10.1017/9781108500111.006
Metabolic interactions between alcohol, the liver and the gastrointestinal tract.
Campbell, S. (2002) · Enlighten: Theses (The University of Glasgow)
Investigation of the effects of diet and exercise on bone growth in young females.
Nurmi-Lawton, J. (2004) · University of Surrey Open Research repository
Quantitative Analyse der Mikrozirkulation von Wunden mit OPS imaging
Langer, S., Born, F., Hatz, R. A., Harris, A. G., & Messmer, K. (2001) · Langenbecks Archiv für Chirurgie. Supplement · doi:10.1007/978-3-642-56698-1_114
Suzuki, M., Kirimoto, H., Inamura, A., Omori, Y., & Yamada, S. (2011) · IGI Global eBooks · doi:10.4018/978-1-60960-559-9.ch032
Skin Surface Roughness Measurement for Assessing Scaliness of Psoriasis Lesions
Hani, A. F. M., & Prakasa, E. (2014) · CRC Press eBooks · doi:10.1201/b16703-2
Assessing the Validity of Alternative Methods for Toxicity Testing
Chamberlain, M. P., Carr, G. J., Curren, R., & Bruner, L. H. (2004) · Informa Healthcare eBooks · doi:10.1201/9780203426272.ch48
Acute Kidney Injury: Definitions, Incidence, Diagnosis, and Outcome
Dillon, F., & Camporesi, E. M. (2016) · Springer eBooks · doi:10.1007/978-3-319-33429-5_2
The epidemiology of abdominal adiposity
Rolfe, E. D. L. (2012)
Structural and Molecular Imaging in Cancer Therapy Clinical Trials
Kurland, B. F., & Mankoff, D. A. (2012) · Chapman & Hall/CRC eBooks · doi:10.1201/b11800-28
An Intelligent Algorithm for Home Sleep Apnoea Test Device
Khandoker, A. H. (2011) · IGI Global eBooks · doi:10.4018/978-1-60960-818-7.ch516
Outcome measurement in paediatric physiotherapy
Leake, A. (2007) · Elsevier eBooks · doi:10.1016/b978-0-7506-8886-4.50007-3 · Cited by 1
Measuring mobility in persons with a lower-limb amputation
de Laat, F. A. J. (2013) · University of Groningen research database (University of Groningen / Centre for Information Technology)
Lee, R. C., Wang, Z., Heo, M., Ross, R. S., Janssen, I., & Heymsfield, S. B. (2001) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/73.5.994
Transcutaneous Carbon Dioxide And Oxygen Pressure In Laparoscopic Surgery
Nishiyama, T. (2014) · The Internet Journal of Anesthesiology
Surgery and Critical Care: Epidemiology and Public Health Approach
Cannesson, M. P., & Pearse, R. M. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9781107257115.002
Zhao, Y., Song, W., Zhang, F., Zhou, M., Zhang, W., Walsh, M. J., & Zhang, B. (2016) · Oncotarget · doi:10.18632/oncotarget.10734
Augusto, L., Perandini, B., Okuno, N. M., Hirai, D. M., Simões, H. G., Cyrino, E. S., & Nakamura, F. Y. (2007)
Body Wasting Among Tuberculosis Patients in Urban Uganda
Mupere, E. (2010) · OhioLink ETD Center (Ohio Library and Information Network)
- Methods for Triads of Proportions
Newcombe, R. G. (2012) · CRC Press eBooks · doi:10.1201/b12670-14
Nout, Y. S. (2006) · OhioLink ETD Center (Ohio Library and Information Network)
Methods for studies of diagnostic tests
Blume, J. D. (2016) · Wiley eBooks · doi:10.1002/9781118849712.ch9
Technical Note: A comparison of central and peripheral intraocular pressure using rebound
González‐Méijome, J. M., Fernandes, P. R. B., Jorge, J., Almeida, J. B., & Parafita, M. Á. (2007)
Exploration of distributional models for a novel intensity-dependent normalizationPreprint
Lama, N., Boracchi, P., & Biganzoli, E. M. (2006) · Collection of Biostatistics Research Archive
What Are We Measuring in the Vascular Patient?
Koelemay, M. J. W. (2005) · Elsevier eBooks · doi:10.1016/b978-0-7216-9426-9.50010-8
Rohlwink, U. K. (2009) · Open University of Cape Town (University of Cape Town)
Nutritional needs in critically ill children
Cotting, J., Chaparro, C. J., & Depeyre, J. L. (2012)
Lee, H. J., Ahn, S.-M., Ryu, J. A., & Park, T.-S. (2016) · The Journal of the Korean Orthopaedic Association · doi:10.4055/jkoa.2016.51.4.315
Experience from a Screening Study in Northern Sweden
Wanhainen, A. (2004) · Cited by 1
Funatsu, N., Kawata, R., FUNATSU, H., Oshita, S., & Sakabe, T. (1996) · THE JOURNAL OF JAPAN SOCIETY FOR CLINICAL ANESTHESIA · doi:10.2199/jjsca.16.360
Kreuk, A. M. D., Zevenbergen, A., Oostveen, J. W. V., Schuurhuis, G. J., Huijgens, P. C., & Jonkhoff, A. R. (2001)
Øvrehus, K. A., & Dey, D. (2016) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2016.07.001
Koepp, M. J. (1999) · UCL Discovery (University College London)
Lúcia, C., Bote, A., Fonseca, A. A., Patiño, J. P., Monsalve, A., & Gómez, E. (2012) · Dialnet (Universidad de la Rioja)
van Berkel, A., Rao, J. U., Pellegata, N. S., Küsters, B., Piscaer, I., Plantinga, T. S., Langenhuijsen, J. F., Vriens, D., Gotthardt, M., & Timmers, H. J. L. M. (2015)
Invasive hemodynamic monitoring systems
Marik, P. E. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9781107257115.016
Knafo, J., Thelen, T. H., Verdier, D., Creppy, L., Tournier, C., & Fabre, T. (2016) · Revue de Chirurgie Orthopédique et Traumatologique · doi:10.1016/j.rcot.2016.06.002
Multifrequent work rate forcings in the assessment of oxygen uptake kinetics
Jarvis, D. R. (1999) · SHURA (Sheffield Hallam University Research Archive) (Sheffield Hallam University)
Influence of training and exercise on fat fraction in quantitative muscular MRI
Kaspar, S., Reinhardt, J., Gloor, M., Stippich, C., Fischer, D., & Fischmann, A. (2013)
Diagnosis and Treatment of Unconjugated Hyperbilirubinemia
Schreuder, A. B. (2014) · University of Groningen research database (University of Groningen / Centre for Information Technology)
do Nascimento, M. C., Abreu, C. L. D. C., Costa, R. N., de Moura, W. C., & Delgado, I. F. (2016) · REVISTA DO INSTITUTO ADOLFO LUTZ · doi:10.53393/rial.2015.v74.33487
MYOCARDIAL STRAIN MEASUREMENTS WITH MRI USING FEATURE TRACKING
Victoria, M. K. (2016) · NORA - Norwegian Open Research Archives
The Effect of Noise Exposure on Auditory Threshold, Otoacoustic Emissions, and Electrocochleography
Lake, A. B. (2016) · The Scholarship East Carolina University's Institutional Repository (East Carolina University)
Winter, M. G., Pike, J. D., & Dillard, T. A. (1997) · Respiratory Care · doi:10.1177/002013249704201003
Maalen-Johansen, I. K. (2016) · NVA (Nasjonalt vitenarkiv)
Diagnostische Genauigkeit neuer tragbarer Echokardiographiegeräte mit Doppler und Harmonic Imaging—
Knebel, F., Eddicks, S., Sanad, W., Walde, T., Baumann, G., & Borges, A. C. (2005) · Intensivmedizin und Notfallmedizin · doi:10.1007/s00390-005-0607-8
MRI Visualization and Mathematical Modeling of Local Drug Delivery
Giers, M. B. (2013)
Hypochondroplasia : clinical and molecular spectrum and response to growth hormone therapy.
Ramaswami, U. (2001) · OpenGrey (Institut de l'Information Scientifique et Technique)
Perez, M. (2016) · The University of Queensland · doi:10.14264/uql.2016.523
Ultrasound fetal weight estimation in twin pregnancy
Dimassi, K., Hammemi, A., Karoui, A., Triki, A., & Gara, M. F. (2015) · Perinatal Journal · doi:10.2399/prn.15.0232007
S. K. de Visser B.Eng. (Med.)yz, J. C. Bowden B.Sc.yz, E. Wentrup-Byrne Ph.D.yz,
Rintoul, L., Bostrom, T. E., & Momot, K. I. (2008)
Performance of dried blood spot (DBS) PUNCHER and dried blood spots to measure HIV-1 viral load
Anoumou, D., Salou, M., Ehlan, A., Konou, A. A., Ouro‐médéli, A., Dossim, S., & Ali-Edje, K. (2016) · African Journal of Microbiology Research · doi:10.5897/ajmr2016.8217
The KIMONO-study: on the development of renal injury in children with a solitary functioning kidney
Westland, R. (2014) · Digital Academic REpository of VU University Amsterdam (Vrije Universiteit Amsterdam)
Equipment Accuracy of radial artery blood pressure determi- nation with the Vasotrac TM
Belani, K. G., Buckley, J. J., & Poliac, M. O. (1999)
Klinkhammer‐Schalke, M., Steinger, B., & Lorenz, W. (2008)
Saleh, M. G. (2012) · Open University of Cape Town (University of Cape Town)
3D printed microfluidic device for point-of-care anemia diagnosis
Plevniak, K. (2016) · K-State Research Exchange (Kansas State University)
Accuracy of Commercial Fitness Trackers During High-Intensity Functional Training
Wessel, P. (2016) · TopSCHOLAR (Western Kentucky University)
Determine the mechanical properties of articular cartilage using indentation testing
Chen, X. (2025) · Library, Museums and Press - UDSpace (University of Delaware) · doi:10.58088/q3rh-4474
End user evaluation of DG-PT L Rec, a human recombinant thromboplastin in liquid formulation
Segarra, N., Huguet, J., & Fernández-Forner, B. (2016) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0000000000000604
Reilly, K. A. (2020) · OpenGrey (Institut de l'Information Scientifique et Technique) · doi:10.24384/qdkk-xx26
Patterson, A. C. (2012) · UWSpace (University of Waterloo) · Cited by 1
Performance Evaluation of the MyT4 Technology for Determining ART Eligibility
Sitoe, N. E., Macamo, R., Meggi, B., Tobaiwa, O., Loquiha, O., Bollinger, T., Vojnov, L., & Jani, I. V. (2016) · PLoS ONE · doi:10.1371/journal.pone.0165163
A method to detect tortuosity of vessel using non imaging ultrasound approach in carotid structure
Patil, R. B., & Krishnamoorthy, P. M. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591496
Reilly, J. J., Odame, I., McColl, J., McAllister, P., Gibson, B. E. S., & Wharton, B. A. (1993) · Proceedings of The Nutrition Society · doi:10.1079/pns19930060
Pinna, G. D., Maestri, R., Rovere, M. T. L., & Mortara, A. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1996.646258
Krutinin, G. G., Velkov, V. V., & Klychnikova, E. V. (2016) · Laboratory Service · doi:10.17116/labs20165474-81
Abstracts of Original Communications (University of Aberdeen, Aberdeen, UK. 23–24 July 2002)
Brown, T. J., Avenell, A., Broom, J. I., Smith, W. C. S., Jung, R. T., Campbell, M. K., & Grant, A. M. (2002) · Proceedings of The Nutrition Society · doi:10.1017/s0029665102000289
Detection Of Bursts Of Microneurographic Activity And Estimation Of Burst Parameters
Shiavi, R. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1991.684027
A novel method for tracking of muscle thickness changes in ultrasound image sequences
Chen, X., Guo, Y., Yi, W., & Li, Q. (2012) · International Conference on Computerized Healthcare (ICCH) · doi:10.1109/icch.2012.6724474
Reclaiming the periphery: Kinetic perimetry in patients with glaucoma
Mönter, V. M. (2016) · City Research Online (City University London)
Abderahman, H. N. (2016) · uO Research (University of Ottawa) · doi:10.20381/ruor-272
Kühl, J. T., Kristensen, T. S., Thomsen, A. F., Hindsø, L., Hansen, K. L., Nielsen, O. W., Kelbæk, H., & Kofoed, K. F. (2016) · Data in Brief · doi:10.1016/j.dib.2016.10.032
Miniati, M., Calugi, S., & Mariani, G. (2015)
Kim, C.-M., Lee, C.-H., Choi, Y. A., Kim, B.-C., Jung, D., & Shin, M. (2016) · Archives of Gerontology and Geriatrics · doi:10.1016/j.archger.2016.10.016
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.