STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 44,601–44,700 of 47,868
Suzuki, A., Moniwa, Y., Ishii, K., Fujiwara, S., & Nagatomi, R. (2017) · Transactions of the JSME (in Japanese) · doi:10.1299/transjsme.16-00450
Parkinson, J. (2017) · DalSpace (Dalhousie University)
McKay, J. L. (2017) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/122523
The Microcirculation in Preterm Neonates
van Elteren, H. A. (2017) · EUR Research Repository (Erasmus University Rotterdam)
Reduced sampling protocols with Bayesian hierarchical analysis during minimal model of IVGTT
Agbaje, O. F., Luzio, S. D., Albarrak, A. I., Lunn, D. J., Owens, D. R., & Hovorka, R. (2003) · IFAC Proceedings Volumes · doi:10.1016/s1474-6670(17)33540-1
Roux, N., Sours, C., Lodermeier, J., Pasley, J. D., Wade, S., Miller, C. H. T., Galvagno, S. M., & Fang, R. (2016)
Aguirre, V. (2014) · OakTrust (Texas A&M University Libraries)
Phing, C. H., Saad, H. A., Yusof, B. N. M., & Taib, M. N. M. (2014) · Universiti Putra Malaysia Institutional Repository (Universiti Putra Malaysia)
First trimester fetal biparietal diameter and head circumference in Chinese population
Chen, M., Yang, X., ZHENG, Q., Ou, C., Lee, C. P., Lam, Y. H., & Tang, M. H. Y. (2017) · Journal of Gynecology & Neonatal Biology · doi:10.15436/2380-5595.17.1339
Extending the System Dynamics Toolbox to Address Policy Problems in Transportation and Health
Sabounchi, N. S. (2012) · VTechWorks (Virginia Tech)
Metso, T. (2002) · Työväentutkimus Vuosikirja
Estimation of VO2max from walk exercises with heart rate and accelerometer
정은지, 김경애, Hong, G., Sun, L. B., Choi, H., 박준성, Nho, H., & Doh, H. (2017) · Korean Journal of Sport Science · doi:10.24985/kjss.2017.28.1.37
Continuous glucose monitoring for optimising glycaemic performance in individuals without diabetes.
Thomas, F. (2017) · ORBi (University of Liège) · doi:10.26021/3044
Nuñez, P. A. S., & Camargo, J. M. R. (2013) · instname:Universidad Pontificia Bolivariana
Visual Acuity in Myopes with Standard and Reversed Contrast Optotypes
Ikaunieks, G., Petrova, A., Panke, K., & Krūmiņa, G. (2017) · Proceedings of the Latvian Academy of Sciences Section B Natural Exact and Applied Sciences · doi:10.1515/prolas-2017-0004
UNAM, F. I. |., Silva-Rodríguez, A., & Quezada, M. E. (2018) · doi:10.22402/j.rdipycs.unam.4.1.2018.180.13-19
DIABETES AND OBESITY: EVIDENCE FOR A CARDIOMYOPATHY
Ashrafi, R. (2016) · University of Liverpool · doi:10.17638/03003030
Davey, R. J. (2010) · UWA Profiles and Research Repository (UWA)
Condición física en la adolescencia: Physical fitness in adolescence
Porcel, F. B. O. (2008) · Dialnet (Universidad de la Rioja)
Henderson, F., Alho, R., Riches, P. E., & Picard, F. (2017) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2017.1333164
Miller, B. (2013) · OhioLink ETD Center (Ohio Library and Information Network)
Intraoperative measurement after excision of distal clavicle
Pickett, A. M., Kluk, M. W., Dickens, J. F., Kilcoyne, K. G., & Rue, J.-P. H. (2015) · Current Orthopaedic Practice · doi:10.1097/bco.0000000000000251
Structural and Vascular Changes Following Laser for Diabetic Macular Edema
Leontieva, E. (2016) · TSpace (University of Toronto)
Amundsen, B. H. (2008) · NORA - Norwegian Open Research Archives
Machine-Learning Applications to Gait Biomechanics using Inertial Sensor Signals
Santhiranayagam, B. K. (2016) · Victoria University Research Repository (Victoria University)
Assessment of Left Ventricular Function and Hemodynamics Using Three-dimensional Echocardiography
Shahgaldi, K. (2010) · DiVA (Digitala Vetenskapliga Arkivet)
Hsu, Y., Wu, Y., Ko, K., Hsu, H., & Huang, G. (2017) · Journal of the Chinese Medical Association · doi:10.1016/j.jcma.2017.05.008
ECG-derived respiration in atrial fibrillation
Pupo, D. S., & Rusconi, L. (2017) · Lund University Publications Student Papers (Lund University)
Management of rotator cuff pathology.
Karthikeyan, S. (2026) · Warwick Research Archive Portal (University of Warwick) · doi:10.82444/warw.33741127 · Cited by 1
de Boer, S., & Bron, M. (2011) · Cited by 1
Concussion assessment reliability
Broglio, S. P. (2006)
Crawford, C. G., & Martin, J. D. (2017) · Antarctica A Keystone in a Changing World · doi:10.3133/ofr20171056
INFORMATION SOCIETY TECHNOLOGIES (IST) PROGRAMME
Papadelis, C. L., Lekka, I., Maglaveras, N., & Maglavera, S. (2004) · Cited by 1
Gonçalves, F. A., Amorim, F. H. R., Zangalli, C. E. S., de Vasconcellos, J. P. C., & Costa, V. P. (2017) · Modeling and Artificial Intelligence in Ophthalmology · doi:10.35119/maio.v1i3.37
The LORELIA Residual Test: A New Outlier Identification Test for Method Comparison Studies
Rauch, G. (2009) · State and University Library Bremen
Physiological and Physical Analysis in Anorexia Nervosa (AN) in-patients
Alberti, M. (2012)
Neto, A. S., Martin, F., Rossi, B., Dal, R., Amarante, M., & Rossi, M. (2011)
Telles, R. W. (2007) · Americanae (AECID Library)
A new instrument for recording the spine contourograph
Hein, V. (2003) · DOAJ (DOAJ: Directory of Open Access Journals)
Redmond, L. C. (2017) · Cited by 1
Ambrosino, N., Vitacca, M., Barbano, L., Porta, R., & Bianchi, L. N. C. (2005)
Statistical analysis of method comparison studies
Carstensen, B. (2013)
systemfor measurementofenergy expenditure in sick preterminfants
Fleming, P. (1992)
McFarland, A. M. S., & Millican, J. (2012)
Modeling Cardiac Function With Particle Image Velocimetry
Westerdale, J. (2015)
Elias, L. S. D. T., Guinsburg, R., Peres, C. A., Balda, R. D. C. X., & dos Santos, A. M. N. (2008)
Ribeiro, M. A. D. S., Fiori, H. H., Luz, J. H., Piva, J. P., Ribeiro, N. M. E., & Fiori, R. M. (2011)
Samuel, T., van Dyk, D., Lombard, C. J., & Dyer, R. A. (2017) · Southern African Journal of Anaesthesia and Analgesia · doi:10.1080/22201181.2017.1349360
Control of Oral Anticoagulant Therapy Using EDTA Plasma
Al‐Bayaa, I. M. (2011)
Properties and Optimization of Respiratory Navigator Gating for Spiral Cine DENSE Cardiac MRI
Hamlet, S. M. (2017) · UKnowledge (University of Kentucky) · doi:10.13023/etd.2017.349
천승철 (2011) · YUHSpace (Yonsei University Medical Library)
Eason, E. L., & Toye, B. W. (2003) · Journal of Sexual & Reproductive Medicine · doi:10.4172/1488-5069.1000061
Estabilidade no desempenho de três diferentes técnicas de salto vertical
Carvalho, R. F., Rubini, E. D. C., & Cabral, L. F. (2015) · Caderno de Educação Física e Esporte · doi:10.36453/2318-5104.2014.v12.n2.p21
Strength of Tuberculin Used in the Mantoux Test: Does It Make a Difference?
Mathew, J. L. (2017) · The Indian Journal of Pediatrics · doi:10.1007/s12098-017-2451-9
Aytar, A., Tüzün, E. H., & Eker, L. (2017) · Türk fizyoterapi ve rehabilitasyon dergisi · doi:10.21653/tfrd.336346
Evaluation of computerised programs for the diagnosis and treatment of binocular anomalies
Lin, W. Y. (2016) · Research Explorer (The University of Manchester)
Kadle, R. L., & Phoon, C. K. L. (2017) · World Journal of Cardiology · doi:10.4330/wjc.v9.i8.693
Wang, S., & Lin, A. T. (2006) · The Journal of Urology · doi:10.1016/s0022-5347(06)00579-9
Robinson, S., O'Brien, M. W., & Kimmerly, D. S. (2018) · The FASEB Journal · doi:10.1096/fasebj.2018.32.1_supplement.724.8
The effects of energy availability on bone metabolism and health
Papageorgiou, M. (2016) · Nottingham Trent University's Institutional Repository (Nottingham Trent Repository)
Tugault-Lafleur, C. N., Black, J., & Barr, S. I. (2017) · Advances in Nutrition · doi:10.3945/an.117.015685
Wemmelund, K. B., Ringgård, V. K., Vistisen, S. T., Hyldebrandt, J. A., Sloth, E., & Juhl‐Olsen, P. (2017) · Intensive Care Medicine Experimental · doi:10.1186/s40635-017-0158-x
Capillary blood sampling: are the results comparable to venous sampling in health and disease
Lightbody, T. O. (2017) · University of Birmingham Institutional Research Archive (University of Birmingham) · Cited by 2
A Biomechanical Model of Human Upper Limb for Objective Stroke Rehabilitation Assessment
Ang, W. S. (2017) · KiltHub Repository · doi:10.1184/r1/6714527.v1
The use of diet diaries in clinical dentistry
Arheiam, A. A. (2017) · University of Liverpool · doi:10.17638/03008005
Ambulatory assessment of motor performance after stroke
van Meulen, F. (2017) · doi:10.3990/1.9789036543811
Beyond the tissue: the relationship between structure, function, and pain in Achilles tendinopathy
Auliffe, S. M. (2017) · University of Limerick Institutional Repository (University of Limerick) · doi:10.34961/7905
The Effects of Digital Story Communication on Health Literacy Indicators in the Mining Industry
Shannon, H. A. (2017) · Queensland University of Technology · doi:10.5204/thesis.eprints.107546
The development and validation of a custom built device for assessing frontal knee joint laxity
Ismail, S. A., Simić, M., Clarke, J., Lopes, T. J. A., & Pappas, E. (2017) · The Knee · doi:10.1016/j.knee.2017.08.053
Three-dimensional Quantitative Magnetic Resonance Imaging of Carotid Atherosclerotic Plaque
Yuan, J. (2017) · Apollo (University of Cambridge) · doi:10.17863/cam.13652
Poveda-Pagán, E. J., García, I. C., Lozano, A. S., Segura, J., & Lozano-Quijada, C. (2017) · Fisioterapia · doi:10.1016/j.ft.2017.07.003
Reliability of Javal’s Rule Based on Dioptric Power Matrix
Yu, D.-S., Cho, H. G., Kim, S.-Y., Kim, H.-S., & Moon, B.-Y. (2017) · Journal of Korean Ophthalmic Optics Society · doi:10.14479/jkoos.2017.22.3.253
Meng, X., Zang, G., Li, R., Fan, L., Liu, J., & Wang, Z. (2017) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000304
Norgett, Y. (2015) · Anglia Ruskin Research Online (Anglia Ruskin University) · Cited by 1
Magnetic Resonance Imaging of Myocardial Deformation and Scarring in Coronary Artery Disease.
Kihlberg, J. (2017) · Linköping University medical dissertations · doi:10.3384/diss.diva-143028
A Novel Approach to Assess Performance of Glucometer: Error Grid Analysis
Kumavat, V., Rojekar, M. V., Panot, J., & Adhe-Rojekar, A. (2017) · Point of Care The Journal of Near-Patient Testing & Technology · doi:10.1097/poc.0000000000000150
Okatsu, Y., YAMAGISHI, N., HATATE, K., & Devkota, B. (2017) · Polish Journal of Veterinary Sciences · doi:10.1515/pjvs-2017-0064
Developing an Alternative Methodology for Measuring Regional Skeletal Muscle Blood Flow
Polonsky, M. S. (2017) · Scholars' Bank (University of Oregon)
Psychometric evidence of body composition as a multidimensional trait in college students
Hart, P. D., & Health Demographics, H. (2017) · International Journal of Physical Education Fitness and Sports · doi:10.26524/ijpefs1741
Foot, ankle and lower limb somatosensory dysfunction in stroke
Gorst, T. (2017) · PEARL (University of Plymouth) · doi:10.24382/591
Individualisation of mycophenolate mofetil therapy
van Hest, R. M., & Reinier, M. (2007)
7 Beoordelen van de methodologische kwaliteit van een meetinstrument
Terwee, C. B., Beurskens, S., & Wittink, H. M. (2012) · Bohn Stafleu van Loghum eBooks · doi:10.1007/978-90-313-9223-0_7
Malaguti, C., Albuquerque, V. S., & Corso, S. D. (2017) · COPD Journal of Chronic Obstructive Pulmonary Disease · doi:10.1080/15412555.2017.1412415
Padwal, R. S., Townsend, R. R., Trudeau, L., Hamilton, P. G., & Gelfer, M. (2014)
Influence of elbow angle on the reliability and validity of bioelectrical impedance analysis
Pettitt, R. W., Mehrhoff, J. B., Mandeville, D. S., Pettitt, C. D., & Murray, S. R. (2017) · Journal of Sports Medicine and Therapy · doi:10.29328/journal.jsmt.1001019 · Cited by 1
Obst, S. J. (2016) · Griffith Research Online · doi:10.25904/1912/2543
McDaniely, G., Mitchelly, K. L., Charlesz, C., & Krausy, V. B. (2010)
THE NOVEL MOBILE DEVICE APPLICATION OF CAPSTESIA AIMED TO DEFINE THE NEED FOR FLUID THERAPY
Перфильев, Р. С., Skripkin, Y. V., Ovezov, A. M., & Likhvantsev, V. V. (2017) · Messenger of Anesthesiology and Resuscitation · doi:10.21292/2078-5658-2017-14-6-52-56
How valid are predictive equations to estimate resting energy expenditure in obese elderly
Koopman, J., & Ruigrok, E. (2012)
Verkerk, G. J. Q., Wolf, M., Louwers, A., Meester‐Delver, A., & Nollet, F. (2007) · Data Archiving and Networked Services (DANS)
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.