STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 8,201–8,300 of 47,868
Barlis, P., Dimopoulos, K., Tanigawa, J., Dzielicka, E., Ferrante, G., Furia, F. D., & Mario, C. D. (2009) · International Journal of Cardiology · doi:10.1016/j.ijcard.2008.11.204 · Cited by 59
Ljungquist, T., Harms‐Ringdahl, K., Nygren, Å., & Jensen, I. B. (1999) · Physiotherapy Research International · doi:10.1002/pri.167 · Cited by 63
Point Accuracy of Interstitial Continuous Glucose Monitoring During Exercise in Type 1 Diabetes
Yardley, J. E., Sigal, R. J., Kenny, G. P., Riddell, M. C., Lovblom, L. E., & Perkins, B. A. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0182 · Cited by 58
Human whole‐blood relaxometry at 1.5T: Assessment of diffusion and exchange models
Stefanovic, B., & Pike, G. B. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20218 · Cited by 59
Verhappen, M. H., Pouwels, P. J. W., Ljumanović, R., van der Putten, L., Knol, D. L., de Bree, R., & Castelijns, J. A. (2012) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2949 · Cited by 59
Errors in Quantitative Image Analysis due to Platform-Dependent Image Scaling
Chenevert, T. L., Malyarenko, D. I., Newitt, D. C., Li, X., Jayatilake, M. L., Tudorica, A., Fedorov, A., Kikinis, R., Liu, T. T., Muzi, M., et al. (2014) · Translational Oncology · doi:10.1593/tlo.13811 · Cited by 59
Infrared thermal imaging of the inner canthus of the eye as an estimator of body core temperature
Teunissen, L. P. J., & Daanen, H. A. M. (2011) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2011.554595 · Cited by 59
Study of Human Outdoor Walking with a Low-Cost GPS and Simple Spreadsheet Analysis
Faucheur, A. L., Abraham, P., Jaquinandi, V., Bouyé, P., Saumet, J. L., & Noury-Desvaux, B. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3180cc20c7 · Cited by 69
Anatomic consideration of caudal epidural space: A cadaver study
Aggarwal, A., Kaur, H., Batra, Y. K., Aggarwal, A. K., Subramanyam, R., & Sahni, D. (2009) · Clinical Anatomy · doi:10.1002/ca.20832 · Cited by 59
Testa, A. C., Timmerman, D., Belle, V. V., Fruscella, E., Holsbeke, C. V., Savelli, L., Ferrazzi, E. M., Leone, F. P. G., Marret, H., Tranquart, F., et al. (2009) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.7464 · Cited by 59
Andreasen, M. L., Langhoff, L., Jensen, T. S., & Albert, H. (2007) · Journal of Manipulative and Physiological Therapeutics · doi:10.1016/j.jmpt.2006.11.009 · Cited by 59
Clancy, J. P., Szczesniak, R. D., Ashlock, M. A., Ernst, S. E., Fan, L., Hornick, D. B., Karp, P. H., Khan, U., Lymp, J. F., Ostmann, A. J., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0073905 · Cited by 63
Storto, G., Cirillo, P. L., Vicario, M. L. E., Pellegrino, T., Sorrentino, A. R., Petretta, M., Galasso, G., Sanctis, V. D., Piscione, F., & Cuocolo, A. (2004) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2004.08.007 · Cited by 59
Zakeri, I., Adolph, A. L., Puyau, M. R., Vohra, F. A., & Butte, N. F. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00729.2009 · Cited by 63
Applanation tonometry: a comparison of the Perkins handheld and Goldmann slit lamp-mounted methods
Arora, R., Austin, M., & Bellamy, H. (2014) · Clinical ophthalmology · doi:10.2147/opth.s53544 · Cited by 62
O’Donnell, C., Hartwig, A., & Radhakrishnan, H. (2012) · Cornea · doi:10.1097/ico.0b013e31823f8e2f · Cited by 59
Ay, H., Arsava, E. M., Vangel, M. G., Oner, B., Zhu, M., Wu, O., Singhal, A. B., Koroshetz, W. J., & Sorensen, A. G. (2008) · Stroke · doi:10.1161/strokeaha.107.502104 · Cited by 60
Breast Volumetry Using a Three-Dimensional Surface Assessment Technique
Koch, M., Adamietz, B. R., Jud, S. M., Fasching, P. A., Haeberle, L., Karbacher, S., Veit, K., Schulz-Wendtland, R., Uder, M., Beckmann, M. W., et al. (2011) · Aesthetic Plastic Surgery · doi:10.1007/s00266-011-9708-x · Cited by 59
Assessment of water use for estimating exposure to tap water contaminants.
Shimokura, G. H., Savitz, D. A., & Symanski, E. (1998) · Environmental Health Perspectives · doi:10.1289/ehp.9810655 · Cited by 54
Description and Validation of a Test to Evaluate Sustained Silent Reading
Ramulu, P. Y., Swenor, B. K., Jefferys, J. L., & Rubin, G. S. (2012) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.12-10617 · Cited by 59
Ramírez, E., Valencia, M. E., Bourges, H., Espinosa, T. Z., Moya-Camarena, S. Y., Salazar, G., & Alemán-Mateo, H. (2012) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2012.89 · Cited by 70
Ambriz-Vilchis, V., JESSOP, N. S., Fawcett, R. H., Shaw, D. J., & Macrae, A. (2015) · Journal of Dairy Science · doi:10.3168/jds.2014-8565 · Cited by 59
Berghaus, L. J., Giguère, S., Guldbech, K., Warner, E., Ugorji, U., & Berghaus, R. D. (2015) · Journal of Clinical Microbiology · doi:10.1128/jcm.02673-14 · Cited by 59
Contralateral Elbow Radiographs Can Reliably Diagnose Radial Head Implant Overlengthening
Athwal, G. S., Rouleau, D. M., MacDermid, J. C., & King, G. J. W. (2011) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.j.01244 · Cited by 59
Godang, K., Qvigstad, E., Voldner, N., Isaksen, G. A., Frøslie, K. F., Nøtthellen, J., Henriksen, T., & Bollerslev, J. (2010) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2010.01.121 · Cited by 67
Maxwell, S. L., & Gove, N. E. (2007) · The Journal of the Acoustical Society of America · doi:10.1121/1.2799500 · Cited by 59
Ilea, D. E., Duffy, C., Kavanagh, L. N., Stanton, A. V., & Whelan, P. F. (2012) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2013.2547 · Cited by 66
Schindler, T. H., Zhang, X.-L., Prior, J. O., Cadenas, J. G., Dahlbom, M. L., Sayre, J. W., & Schelbert, H. R. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-007-0378-5 · Cited by 62
Robach, P., Calbet, J. A. L., Thomsen, J. J., Boushel, R., Mollard, P., Rasmussen, P. V., & Lundby, C. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002996 · Cited by 61
Reliability of heart rate variability measures at rest and during light exercise in children
Winsley, R. J., Armstrong, N., Bywater, K., & Fawkner, S. G. (2003) · British Journal of Sports Medicine · doi:10.1136/bjsm.37.6.550 · Cited by 61
Hirai, T., Kitajima, M., Nakamura, H., Okuda, T., Sasao, A., Shigematsu, Y., Utsunomiya, D., Oda, S., Uetani, H., Morioka, M., et al. (2011) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2725 · Cited by 59
Okamura, T., Gonzalo, N., Gutiérrez‐Chico, J. L., Serruys, P. W. J. C., Bruining, N., de Winter, S., Dijkstra, J., Commossaris, K., van Geuns, R., van Soest, G., et al. (2010) · EuroIntervention · doi:10.4244/eijv6i1a62 · Cited by 59
Is it time to confine Snellen charts to the annals of history?
Lovie‐Kitchin, J. E. (2015) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12252 · Cited by 59
Estimation of hemodynamic parameters from seismocardiogram
Tavakolian, K., Blaber, A. P., Ngai, B., & Kamińska, B. (2010) · Computing in cardiology · Cited by 59
Lichtwark, G. A., Cresswell, A. G., & Newsham‐West, R. (2013) · Journal of Experimental Biology · doi:10.1242/jeb.094219 · Cited by 59
Schaap, M., van Walsum, T., Neefjes, L. A., Metz, C. E., Capuano, E., de Bruijne, M., & Niessen, W. J. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2160556 · Cited by 63
Pelvimetry revisited: Analyzing cephalopelvic disproportion
Lenhard, M., Johnson, T. R. C., Weckbach, S., Nikolaou, K., Friese, K., & Hasbargen, U. (2009) · European Journal of Radiology · doi:10.1016/j.ejrad.2009.04.042 · Cited by 59
Kammersgaard, T. S., Malmkvist, J., & Pedersen, L. J. (2013) · animal · doi:10.1017/s1751731113001778 · Cited by 63
Validity of the Actical for estimating free-living physical activity
Crouter, S. E., DellaValle, D. M., Horton, M., Haas, J. D., Frongillo, E. A., & Bassett, D. R. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1758-2 · Cited by 59
Comparison of Cardiac Troponin I Immunoassays Variably Affected by Circulating Autoantibodies
Eriksson, S., Ilva, T., Becker, C., Lund, J., Porela, P., Pulkki, K. J., Voipio‐Pulkki, L., & Pettersson, K. S. I. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2004.040089 · Cited by 59
Influence of fogging lenses and cycloplegia on open‐field automatic refraction
Queirós, A., González‐Méijome, J. M., & Jorge, J. (2008) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2008.00579.x · Cited by 59
Waaijer, A., van der Schaaf, I. C., Velthuis, B. K., Quist, M. J., van Osch, M. J. P., Vonken, E.-J. P. A., van Leeuwen, M. S., & Prokop, M. (2007) · PubMed · Cited by 61
Kingdon, E., Knight, C. J., Dustan, K., Irwin, A. G., Thomas, M., Powis, S. H., Burns, A., Hilson, A. J. W., & Black, C. M. (2002) · British journal of rheumatology · doi:10.1093/rheumatology/keg023 · Cited by 61
SRIVATHSAN, K., GAMI, A. S., BARRETT, R., MONAHAN, K., PACKER, D. L., & ASIRVATHAM, S. J. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00961.x · Cited by 59
Hoppe, U. C., Vanderheyden, M., Sievert, H., Brandt, M. C., Tobar, R., Wijns, W. C., & Rozenman, Y. (2009) · Heart · doi:10.1136/hrt.2008.153486 · Cited by 66
Heart rate detection from an electronic weighing scale
González-Landaeta, R., Casas, Ó., & Pallas-Areny, R. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/8/009 · Cited by 71
Teo, K. S. L., Dundon, B. K., Molaee, P., Williams, K., Carbone, A., Brown, M., Worthley, M. I., DISNEY, P. J. S., Sanders, P., & Worthley, S. G. (2008) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-10-55 · Cited by 63
Pellacani, G., Ulrich, M., Casari, A., Prow, T. W., Cannillo, F., Benati, E., Losi, A., Cesinaro, A. M., Longo, C., Argenziano, G., et al. (2015) · Journal of the European Academy of Dermatology and Venereology · doi:10.1111/jdv.13215 · Cited by 59
Oliveira, S., Cohen, R., van Walsum, M., van Dongen, G. A. M. S., Elias, S. G., van Diest, P. J., Mali, W. P. T. M., & Henegouwen, P. M. P. V. B. E. (2012) · EJNMMI Research · doi:10.1186/2191-219x-2-50 · Cited by 59
Alf, M., Wyss, M. T., Buck, A., Weber, B., Schibli, R., & Krämer, S. D. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.107474 · Cited by 59
Assessment of the carotid artery by MRI at 3T: A study on reproducibility
Dehnavi, R. A., Doornbos, J., Tamsma, J. T., Stuber, M., Putter, H., van der Geest, R. J., Lamb, H. J., & Roos, A. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20904 · Cited by 65
Fountoulakis, K. Ν., Iacovides, A., Kleanthous, S., Samolis, S., Gougoulias, K., Kaprinis, G., & Bech, P. (2003) · BMC Psychiatry · doi:10.1186/1471-244x-3-21 · Cited by 67
Pre-analytical effects of pneumatic tube transport on impedance platelet aggregometry
Bolliger, D., Seeberger, M. D., Tanaka, K. A., Dell‐Kuster, S., Gregor, M., Zenklusen, U., Grapow, M. T. R., Tsakiris, D. A., & Filipovic, M. (2009) · Platelets · doi:10.1080/09537100903236462 · Cited by 61
Rener-Sitar, K., John, M. T., Bandyopadhyay, D., Howell, M. J., & Schiffman, E. L. (2014) · Health and Quality of Life Outcomes · doi:10.1186/1477-7525-12-10 · Cited by 59
Ghatwary, T., Karthikesalingam, A., Patterson, B. O., Hinchliffe, R. J., Morgan, R., Loftus, I. M., Salem, A., THOMPSON, M. M., & Holt, P. (2012) · Journal of Endovascular Therapy · doi:10.1583/11-3731mr.1 · Cited by 60
de Meijer, V. E., Sant, H. P. V., Spronk, S., Kusters, F. J., & den Hoed, P. T. (2008) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2008.03.010 · Cited by 65
Dental age estimation of living persons: Comparison of MRI with OPG
Baumann, P., Widek, T., Merkens, H., Boldt, J., Petrovič, A., Urschler, M., Kirnbauer, B., Jakse, N., & Scheurer, E. (2015) · Forensic Science International · doi:10.1016/j.forsciint.2015.06.001 · Cited by 59
Evaluation of four portable blood glucose meters in diabetic and non-diabetic dogs and cats
Kang, M., Kim, D., Jeong, I., Choi, G.-C., & Park, H. (2015) · Veterinary Quarterly · doi:10.1080/01652176.2015.1092617 · Cited by 70
Buchheit, M., Solano, R., & Millet, G. P. (2007) · Pediatric Exercise Science · doi:10.1123/pes.19.2.192 · Cited by 76
A meta-analysis of the validity of FFQ targeted to adolescents
Tabacchi, G., Filippi, A. R., Amodio, E., Jemni, M., Bianco, A., Firenze, A., & Mammina, C. (2015) · Public Health Nutrition · doi:10.1017/s1368980015002505 · Cited by 59
Travin, M. I., Henzlova, M. J., van Eck‐Smit, B. L. F., Jain, D., Carrió, I., Folks, R. D., Garcia, E. V., Jacobson, A. F., & Verberne, H. J. (2016) · Journal of Nuclear Cardiology · doi:10.1007/s12350-015-0336-8 · Cited by 59
Wilson, A., Hides, J. A., Blizzard, L., Callisaya, M. L., Cooper, A. J., Srikanth, V. K., & Winzenberg, T. M. (2016) · Manual Therapy · doi:10.1016/j.math.2016.01.004 · Cited by 59
Zhao, J., Chen, Z., Zhou, Z., Ding, L., & Zhou, X. (2012) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2012.00793.x · Cited by 59
Computer-Vision-Guided Human Pulse Rate Estimation: A Review
Sikdar, A., Behera, S. K., & Dogra, D. P. (2016) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2016.2551778 · Cited by 65
Impact of percutaneous mitral valve repair using the MitraClip system on tricuspid regurgitation
Frangieh, A. H., Gruner, C., Mikulicic, F., Attinger‐Toller, A., Tanner, F. C., Taramasso, M., Corti, R., Grünenfelder, J., Lüsche, T. F., Ruschitzka, F. T., et al. (2016) · EuroIntervention · doi:10.4244/eijv11i14a320 · Cited by 59
Towards best practice in physical and physiological employment standards
Petersen, S. R., Andérson, G. S., Tipton, M., Docherty, D., Graham, T. E., Sharkey, B. J., & Taylor, N. A. S. (2016) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2016-0003 · Cited by 71
Silveira, R. P., Stergiou, P., Carpes, F. P., Castro, F. A. D. S., Katz, L., & Stefanyshyn, D. J. (2016) · Sports Biomechanics · doi:10.1080/14763141.2016.1213875 · Cited by 59
Krautbauer, S., Büchler, C., & Liebisch, G. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b02596 · Cited by 59
Leach, R. J., Forrester, S., Mears, A. C., & Roberts, J. R. (2017) · Measurement · doi:10.1016/j.measurement.2017.08.009 · Cited by 59
Methods for the field evaluation of quantitative G6PD diagnostics: a review
Ley, B., Bancone, G., von Seidlein, L., Thriemer, K., Richards, J. S., Domingo, G. J., & Price, R. N. (2017) · Malaria Journal · doi:10.1186/s12936-017-2017-3 · Cited by 52
Nightingale, T. E., Williams, S., Thompson, D., & Bilzon, J. (2017) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0590-z · Cited by 62
Araya-Salas, M., Smith-Vidaurre, G., & Webster, M. (2019) · Bioacoustics · doi:10.1080/09524622.2017.1396498 · Cited by 60
Shiraishi, Y., Katsumata, Y., Sadahiro, T., Azuma, K., Akita, K., Isobe, S., Yashima, F., Miyamoto, K., Nishiyama, T., Tamura, Y., et al. (2018) · Journal of the American Heart Association · doi:10.1161/jaha.117.006612 · Cited by 64
Classification of pressure ulcer tissues with 3D convolutional neural network
García-Zapirain, B., Elmogy, M. M., El-Baz, A. S., & Elmaghraby, A. S. (2018) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-018-1835-y · Cited by 67
Raj-Koziak, D., Gos, E., Świerniak, W., Rajchel, J. J., Karpiesz, L., Niedziałek, I., Włodarczyk, E. A., Skarżyńśki, H., & Skarzynski, P. H. (2018) · Audiology and Neurotology · doi:10.1159/000494021 · Cited by 64
Zrenner, M., Gradl, S., Jensen, U. J., Ullrich, M., & Eskofier, B. M. (2018) · Sensors · doi:10.3390/s18124194 · Cited by 67
Pathogenic TERT promoter variants in telomere diseases
Gutierrez-Rodrigues, F., Donaires, F. S., Pinto, A., Vicente, A., Dillon, L. W., Clé, D. V., Santana, B. A., Pirooznia, M., Ibanez, M. D. P. F., Townsley, D. M., et al. (2019) · Genetics in Medicine · doi:10.1038/s41436-018-0385-x · Cited by 61
Lee, S. M., Lee, J., Lee, G., Choe, J., Do, K., Kim, N., & Seo, J. B. (2019) · Korean Journal of Radiology · doi:10.3348/kjr.2018.0249 · Cited by 62
WearBreathing: Real World Respiratory Rate Monitoring Using Smartwatches
Liaqat, D., Abdalla, M., Abed-Esfahani, P., Gabel, M., Son, T., Wu, R., Gershon, A., Rudzicz, F., & Lara, E. D. (2019) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3328927 · Cited by 58
Moimas, S., Salton, F., Kośmider, B., Ring, N., Volpe, M. C., Bahmed, K., Braga, L., Rehman, M., Vodret, S., Graziani, M. L., et al. (2019) · ERJ Open Research · doi:10.1183/23120541.00138-2019 · Cited by 72
Middlebrook, N., Heneghan, N. R., Evans, D. W., Rushton, A., & Falla, D. (2020) · PLoS ONE · doi:10.1371/journal.pone.0233521 · Cited by 74
Jiang, Y., Hernandez, V., Venture, G., Kulić, D., & Chen, B. K. (2021) · Sensors · doi:10.3390/s21041499 · Cited by 59
Midena, E., Torresin, T., Velotta, E., Pilotto, E., Parrozzani, R., & Frizziero, L. (2021) · Frontiers in Immunology · doi:10.3389/fimmu.2021.613051 · Cited by 60
Chest CT Measures of Muscle and Adipose Tissue in COPD
Díaz, A. A., Zhou, L., Young, T., McDonald, M., Harmouche, R., Ross, J. C., Estépar, R. S. J., Wouters, E. F. �., Coxson, H. O., MacNee, W., et al. (2014) · Academic Radiology · doi:10.1016/j.acra.2014.05.013 · Cited by 66
Dimeski, G., & Barnett, R. J. (2005) · Critical Care and Resuscitation · doi:10.1016/s1441-2772(23)01564-8 · Cited by 59
Wilson, M. J., Boyd, S. Y. N., Lisagor, P. G., Rubal, B. J., & Cohen, D. J. (2000) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(00)01256-x · Cited by 59
Kien, C. L., & Ugrasbul, F. (2004) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/80.4.876 · Cited by 66
Regional and overall ventilation inhomogeneities in preterm and term-born infants
Riedel, T., Kyburz, M., Latzin, P., Thamrin, C., & Frey, U. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1299-x · Cited by 66
Validation of the BodyGem™ hand-held calorimeter
Melanson, E. L., Coelho, L. B., Tran, Z. V., Haugen, H. A., Kearney, J. T., & Hill, J. O. (2004) · International Journal of Obesity · doi:10.1038/sj.ijo.0802643 · Cited by 62
MMP-2 and MMP-9 levels in peripheral blood after subarachnoid hemorrhage
Horstmann, S., Su, Y., Koziol, J. A., Meyding‐Lamadé, U., Nagel, S., & Wagner, S. (2006) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2006.09.005 · Cited by 59
Buechel, E. R. V., DiBernardo, S., Bauersfeld, U., & Berger, F. F. (2005) · International journal of cardiac imaging · doi:10.1007/s10554-004-4017-y · Cited by 59
Comparison of Five Bilevel Pressure Ventilators in Patients with Chronic Ventilatory Failure
Vitacca, M., Barbano, L., D’Anna, S. E., Porta, R., Bianchi, L. N. C., & Ambrosino, N. (2002) · CHEST Journal · doi:10.1378/chest.122.6.2105 · Cited by 73
Is axillary temperature an appropriate surrogate for core temperature?
Lodha, R., Mukerji, N., Sinha, N., Pandey, R. M., & Jain, Y. K. (2000) · The Indian Journal of Pediatrics · doi:10.1007/bf02758482 · Cited by 59
Laplaud, D., Hug, F., & Grélot, L. (2005) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2005.04.002 · Cited by 76
Soares, B. P., Dankbaar, J. W., Bredno, J., Cheng, S., Bhogal, S. S., Dillon, W. P., & Wintermark, M. (2009) · Neuroradiology · doi:10.1007/s00234-009-0516-9 · Cited by 59
Sexual dimorphism in the energy content of weight change
Pietrobelli, A., Allison, D. B., Heshka, S., Heo, M., Wang, Z., Bertkau, A., Laferrère, B., Rosenbaum, M., Aloia, J. F., Pi-Sunyer, F., et al. (2002) · International Journal of Obesity · doi:10.1038/sj.ijo.0802065 · Cited by 60
A Mathematical Model to Describe Fat Oxidation Kinetics during Graded Exercise
CHENEVIÈRE, X., MALATESTA, D., PETERS, E. M., & BORRANI, F. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31819e2f91 · Cited by 60
Root coverage assessment: validity and reproducibility of an image analysis system
Kerner, S. P., Etienne, D. H., Malet, J., Mora, F., Monnet‐Corti, V., & Bouchard, P. (2007) · Journal Of Clinical Periodontology · doi:10.1111/j.1600-051x.2007.01137.x · Cited by 59
Krombach, G. A., Kühl, H. P., Bücker, A., Mahnken, A. H., Spüntrup, E., Lipke, C. S. A., Schröder, J. W., & Günther, R. W. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10428 · Cited by 59
Prieto, L. M., Ferrer, A., Palop, J., Doménech, J., Llusar, R., & Rojas, R. (2007) · Respiratory Medicine · doi:10.1016/j.rmed.2007.02.023 · Cited by 59
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.