STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 8,101–8,200 of 47,868
Prognostic value of left atrial strain in patients with moderate asymptomatic mitral regurgitation
Cameli, M., Pastore, M. C., Righini, F. M., Mandoli, G. E., D’Ascenzi, F., Lisi, M., Nistor, D., Sparla, S., Curci, V., Tommaso, C. D., et al. (2019) · International journal of cardiac imaging · doi:10.1007/s10554-019-01598-6 · Cited by 67
Hill, M., Hána, V., Velíková, M., Pařízek, A., Kolátorová, L., Vítků, J., Škodová, T., Šimková, M., Šimják, P., Kancheva, R. L., et al. (2019) · Physiological Research · doi:10.33549/physiolres.934124 · Cited by 61
Georgiou, M., Kane, T., Tanna, P., Bouzia, Z., Singh, N., Kalitzeos, A. A., Strauss, R. W., Fujinami, K., & Michaelides, M. (2019) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2019.11.008 · Cited by 62
Bär, J., Boumasmoud, M., Kouyos, R. D., Zinkernagel, A. S., & Vulin, C. (2020) · Scientific Reports · doi:10.1038/s41598-020-72979-4 · Cited by 66
What are the Most Important Statistical Ideas of the Past 50 Years?
Gelman, A., & Vehtari, A. (2021) · Journal of the American Statistical Association · doi:10.1080/01621459.2021.1938081 · Cited by 87
Griebel, A., Bennett, L. T., Culvenor, D. S., Newnham, G. J., & Arndt, S. K. (2015) · Remote Sensing of Environment · doi:10.1016/j.rse.2015.06.014 · Cited by 60
Chest wall kinematics and respiratory muscle action in walking healthy humans
Sanna, A., Bertoli, F., Misuri, G., Gigliotti, F., Iandelli, I., Mancini, M., Duranti, R., Ambrosino, N., & Scano, G. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.3.938 · Cited by 63
Puchades‐Roman, L., Palmer, R. M. J., Palmer, P. J., Howe, L. C., Ide, M., & Wilson, R. F. (2000) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2000.tb00109.x · Cited by 60
Farb, A. A., Devereux, R. B., & Kligfield, P. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90636-4 · Cited by 65
Evaluation of biometric methods for measuring the anterior chamber depth in the non-contact mode
Meinhardt, B., Stachs, O., Stave, J., Beck, R., & Guthoff, R. F. (2005) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-005-0103-7 · Cited by 60
Zethelius, B., Hales, C. N., Lithell, H. O., & Berne, C. (2004) · Diabetes Care · doi:10.2337/diacare.27.6.1433 · Cited by 60
Fakler, U., Pauli, C., Balling, G., Lorenz, H.-P., Eicken, A., Hennig, M., & Hess, J. (2006) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2006.07.038 · Cited by 60
Kyle, U. G., Genton, L., Mentha, G., Nicod, L., Slosman, D. O., & Pichard, C. (2001) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/014860710102500245 · Cited by 60
Rowland, D. G., & Gutgesell, H. P. (1994) · The American Journal of Cardiology · doi:10.1016/0002-9149(94)90503-7 · Cited by 60
Steer, J. A., Papini, R., Wilson, A. P. R., McGrouther, D. A., & Parkhouse, N. (1996) · Burns · doi:10.1016/0305-4179(95)00116-6 · Cited by 60
Sartorial eloquence: does it exist in the paediatrician-patient relationship?
Barrett, T. G., & Booth, I. W. (1994) · BMJ · doi:10.1136/bmj.309.6970.1710 · Cited by 64
Iodine status of New Zealand residents as assessed by urinary iodide excretion and thyroid hormones
Thomson, C. D., Colls, A., Conaglen, J. V., Macormack, M., Stiles, M. K., & Mann, J. I. (1997) · British Journal Of Nutrition · doi:10.1079/bjn19970208 · Cited by 60
Automated detection of sleep disordered breathing using a nasal pressure monitoring device
Grover, S. S., & Pittman, S. D. (2008) · Sleep And Breathing · doi:10.1007/s11325-008-0181-y · Cited by 68
Bradley, P. A., Mortimore, I. L., & Douglas, N. J. (1995) · Thorax · doi:10.1136/thx.50.11.1201 · Cited by 60
Yaman, C., Jesacher, K., & Pölz, W. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(03)01070-6 · Cited by 60
Ribeiro, A. C., JUHLIN‐DANNFELT, A., Brodin, L., Holmgren, A., & Jorfeldt, L. (1998) · American Heart Journal · doi:10.1016/s0002-8703(98)70048-1 · Cited by 60
Corneal power measurements with the Pentacam Scheimpflug camera after myopic excimer laser surgery
Savini, G., Barboni, P., Profazio, V., Zanini, M., & Hoffer, K. J. (2008) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2008.01.012 · Cited by 60
Moilanen, P., Talmant, M., Nicholson, P., Cheng, S., TIMONEN, J., & Laugier, P. (2007) · The Journal of the Acoustical Society of America · doi:10.1121/1.2769619 · Cited by 60
Effect of Angular Error on Tissue Doppler Velocities and Strain
Storaa, C., Åberg, P., Lind, B., & Brodin, L. (2003) · Echocardiography · doi:10.1046/j.1540-8175.2003.01135.x · Cited by 60
Rudat, V., Dietz, A., Conradt, C., Weber, K., & Flentje, M. P. (1997) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(97)01933-6 · Cited by 60
Comparison of two Hologic DXA systems (QDR 1000 and QDR 4500/A).
Barthe, N., Braillon, P. M., Ducassou, D., & Basse‐Cathalinat, B. (1997) · British Journal of Radiology · doi:10.1259/bjr.70.835.9245885 · Cited by 60
Teutelink, A., Muhs, B. E., Vincken, K. L., Bartels, L. W., Cornelissen, S. A., van Herwaarden, J. A., Prokop, M., Moll, F. L., & Verhagen, H. J. M. (2007) · Journal of Endovascular Therapy · doi:10.1583/06-1976.1 · Cited by 60
Impact of lung volume on MR signal intensity changes of the lung parenchyma
Bankier, A. A., O’Donnell, C. R., Mai, V. M., Storey, P., Maertelaer, V. D., Edelman, R. R., & Chen, Q. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20198 · Cited by 60
Three-dimensional ultrasound biomicroscopy for xenograft growth analysis
Cheung, A., Brown, A. S., Hastie, L. A., Cucevic, V., Roy, M. M., Lacefield, J. C., Fenster, A., & Foster, F. S. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2005.03.003 · Cited by 60
Monitoring Left Ventricular Function in Adults Receiving Anthracycline-Containing Chemotherapy
Belham, M., Kruger, A. R., Mepham, S., Faganello, G., & Pritchard, C. W. (2006) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2006.09.007 · Cited by 60
Measurement of vessel wall strain using cine phase contrast MRI
Wedding, K. L., Draney, M. T., Herfkens, R. J., Zarins, C. K., Taylor, C. A., & Pelc, N. J. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10077 · Cited by 60
Impedance cardiographyThe impact of new technology
Critchley, L. A. H. (1998) · Anaesthesia · doi:10.1046/j.1365-2044.1998.437-az0550.x · Cited by 60
Teh, H. S., Ang, E. S., Wong, W. C., Tan, S. B., Tan, A. G. S., Chng, S. M., Lin, M. B. K., & Goh, J. S. K. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.181.2.1810441 · Cited by 61
Ruel, M. T., Dewey, K., Martínez, C., Flores, R., & Brown, K. (1997) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/65.2.439 · Cited by 64
Histopathological correlation of corneal diseases with optical coherence tomography
Wirbelauer, C., Winkler, J., Bastian, G. O., Häberle, H., & Pham, D. T. (2002) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-002-0518-3 · Cited by 62
Pressure-volume-based single-beat estimations cannot predict left ventricular contractility in vivo
Kjørstad, K. E., Korvald, C., & Myrmel, T. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00638.2001 · Cited by 70
Theisen, C., van Wagensveld, A., Timmesfeld, N., Efe, T., Heyse, T. J., Fuchs‐Winkelmann, S., & Schofer, M. D. (2010) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-11-135 · Cited by 76
Fors, H., Gelander, L., Bjarnason, R. G., Albertsson-Wikland, K. G., & Bosaeus, I. G. (2002) · Acta Paediatrica · doi:10.1080/08035250213215 · Cited by 60
Fraser, A. G., Rosalki, S. B., Gamble, G. D., & Pounder, R. E. (1995) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.1995.tb04561.x · Cited by 60
Multilaboratory Comparison of Hepatitis C Virus Viral Load Assays
Caliendo, A. M., Valsamakis, A., Zhou, Y., Yen‐Lieberman, B., Andersen, J., Young, S. A., Ferreira‐Gonzalez, A., Tsongalis, G. J., Pyles, R., Bremer, J. W., et al. (2006) · Journal of Clinical Microbiology · doi:10.1128/jcm.44.5.1726-1732.2006 · Cited by 60
Tuğrul, M., Çamcı, E., Pembeci, K., Al-Darsani, A., & Telci, L. (2004) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2004.05.022 · Cited by 60
Quittan, M., Wiesinger, G. F., Crevenna, R., Nuhr, M. J., Posch, M., Hülsmann, M., Müller, D., Pacher, R., & Fialka-Moser, V. (2001) · Journal of Rehabilitation Medicine · doi:10.1080/165019701750300654 · Cited by 57
Dumville, J. C., Panerai, R. B., Lennard, N., Naylor, A. R., & Evans, D. H. (1998) · Stroke · doi:10.1161/01.str.29.5.968 · Cited by 60
Gosselink, R., Wagenaar, R. C., & Decramer, M. (1996) · Thorax · doi:10.1136/thx.51.6.601 · Cited by 61
Isbell, D. C., Meyer, C. H., Rogers, W., Epstein, F. H., DiMaria, J. M., Harthun, N. L., Wang, H., & Kramer, C. M. (2006) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640600843330 · Cited by 62
Localization and quantification of mitral valve prolapse using three-dimensional echocardiography
Delabays, A., Jeanrenaud, X., CHASSOT, P., VONSEGESSER, L., & KAPPENBERGER, L. J. (2004) · European Journal of Echocardiography · doi:10.1016/j.euje.2004.03.007 · Cited by 60
Volume estimation of extensor muscles of the lower leg based on MR imaging
Lund, H., Christensen, L., Savnik, A., Boesen, J., Danneskiold‐Samsøe, B., & Bliddal, H. (2002) · European Radiology · doi:10.1007/s00330-002-1334-1 · Cited by 60
Rose, B. S., Flatt, W. P., Martin, R. J., & Lewis, R. D. (1998) · Journal of Nutrition · doi:10.1093/jn/128.2.246 · Cited by 60
Sohlström, A., Wahlund, L., & Forsum, E. (1993) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/58.6.830 · Cited by 61
Ambulatory blood pressure monitoring in elderly patients with isolated systolic hypertension
Thijs, L., Amery, A. K. P. C., Clement, D. L., Cox, J., Cort, P. D., Fagard, R. H., Fowler, G., Guo, C., Mancia, G., Marín, R., et al. (1992) · Journal of Hypertension · doi:10.1097/00004872-199207000-00014 · Cited by 60
Surface EMG measurements during fMRI at 3T: Accurate EMG recordings after artifact correction
van Duinen, H., Zijdewind, I., Hoogduin, H. M., & Maurits, N. M. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.04.003 · Cited by 61
Hackstein, N., Bauer, J., Hauck, E. W., Ludwig, M., Krämer, H., & Rau, W. S. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.181.1.1810147 · Cited by 60
Prediction of general practice workload from census based social deprivation scores.
Ben-Shlomo, Y., White, I., & McKeigue, P. M. (1992) · Journal of Epidemiology and Community Health · doi:10.1136/jech.46.5.532 · Cited by 60
Coronary artery calcium volume scores on electron beam tomography in 12,936 asymptomatic adults
Nasir, K., Raggi, P., Rumberger, J. A., Braunstein, J. B., Post, W. S., Budoff, M. J., & Blumenthal, R. S. (2004) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2004.01.043 · Cited by 66
Radionuclide left ventricular ejection fraction: a comparison of three methods.
Hains, A. D. B., Al-Khawaja, I., Hinge, D., Lahiri, A., & Raftery, E. B. (1987) · Heart · doi:10.1136/hrt.57.3.242 · Cited by 60
Taylor, R. W., & Goulding, A. (1998) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1600575 · Cited by 60
Samra, J. S., Frayn, K. N., Giddings, J. A., Clark, M. L., & Macdonald, I. A. (1995) · Clinical Physiology · doi:10.1111/j.1475-097x.1995.tb00515.x · Cited by 60
Lee, D., Fuisz, A., Fan, P., Hsu, T., Liu, C.-P., & Chiang, H.-T. (2001) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2001.113647 · Cited by 60
Kiely, J., Delahunty, C., Matthews, S., & McNicholas, W. (1996) · European Respiratory Journal · doi:10.1183/09031936.96.09112360 · Cited by 60
Chen, C., Rodríguez, L., Lethor, J. P., Levine, R. A., Semigran, M. J., Fifer, M. A., Weyman, A. E., & Thomas, J. D. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90645-9 · Cited by 60
Flanagan, J. G., Wild, J. M., & Trope, G. E. (1993) · Ophthalmology · doi:10.1016/s0161-6420(13)31551-6 · Cited by 69
Urate production by human heart
Huizer, T. (1989) · Journal of Molecular and Cellular Cardiology · doi:10.1016/0022-2828(89)90610-x · Cited by 60
GABRIELCZYK, M. R., & BUIST, R. J. (1988) · Anaesthesia · doi:10.1111/j.1365-2044.1988.tb09025.x · Cited by 59
Validation of a Photoplethysmographic Heart Rate Monitor: Polar OH1
Hermand, E., Cassirame, J., Ennequin, G., & Hue, O. (2019) · International Journal of Sports Medicine · doi:10.1055/a-0875-4033 · Cited by 59
Sifakakis, I., Papaioannou, W., Papadimitriou, A., Kloukos, D., Papageorgiou, S. N., & Eliades, T. (2018) · Progress in Orthodontics · doi:10.1186/s40510-018-0230-4 · Cited by 59
Development and validity of the DyNaChron questionnaire for chronic nasal dysfunction
Kacha, S., Guillemin, F., & Jankowski, R. (2012) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-011-1690-z · Cited by 59
Moon, J. R., Stout, J. R., Smith-Ryan, A. E., Kendall, K. L., Fukuda, D. H., Cramer, J. T., & Moon, S. E. (2013) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2012.163 · Cited by 59
Gusmer, R. J., Bosch, T. A., Watkins, A. N., Ostrem, J. D., & Dengel, D. R. (2014) · The Open Sports Medicine Journal · doi:10.2174/1874387001408010011 · Cited by 59
Kauffmann, C., Douane, F., Thérasse, É., Lessard, S., Elkouri, S., Gilbert, P., Beaudoin, N., Pfister, M., Blair, J.-F., & Soulez, G. (2015) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2014.12.019 · Cited by 59
Banik, S. D. (2011) · Annals of Human Biology · doi:10.3109/03014460.2011.616227 · Cited by 59
Wong, J., Sridharan, S., Berdeprado, J., Vilar, E., Viljoen, A., Wellsted, D. M., & Farrington, K. (2016) · Kidney International · doi:10.1016/j.kint.2015.12.042 · Cited by 59
Bilateral Asymmetry in the Human Pelvis
Kurki, H. K. (2017) · The Anatomical Record · doi:10.1002/ar.23546 · Cited by 59
O'Brien, B., Schoenhagen, P., Kapadia, S. R., Svensson, L. G., Rodríguez, L., Griffin, B. P., Tuzcu, E. M., & Desai, M. Y. (2011) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.111.964916 · Cited by 60
Accuracy of P0.1 measurements performed by ICU ventilators: a bench study
Beloncle, F., Piquilloud, L., Olivier, P., Vuillermoz, A., Yvin, É., Mercat, A., & Richard, J.-C. (2019) · Annals of Intensive Care · doi:10.1186/s13613-019-0576-x · Cited by 59
Heinen, R., Steenwijk, M. D., Barkhof, F., Biesbroek, J. M., van der Flier, W. M., Kuijf, H. J., Prins, N. D., Vrenken, H., Biessels, G. J., de Bresser, J., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-52966-0 · Cited by 68
Flegal, K. M., Graubard, B. I., & Ioannidis, J. P. A. (2019) · International Journal of Obesity · doi:10.1038/s41366-019-0499-5 · Cited by 64
A comparison of cine CMR imaging at 0.55 T and 1.5 T
Bandettini, W. P., Shanbhag, S. M., Mancini, C., McGuirt, D. R., Kellman, P., Xue, H., Henry, J. L., Lowery, M., Thein, S. L., Chen, M. Y., et al. (2020) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-020-00618-y · Cited by 59
Assessment of inactivation procedures for SARS-CoV-2
Auerswald, H., Yann, S., Dul, S., In, S., Dussart, P., Martin, N. J., Karlsson, E. A., & Garcia-Rivera, J. A. (2021) · Journal of General Virology · doi:10.1099/jgv.0.001539 · Cited by 62
Jung, M. H., Namkoong, K., Lee, Y., Koh, Y. J., Eom, K., Jang, H., Jung, W., Bae, J., & Park, J. (2021) · Scientific Reports · doi:10.1038/s41598-020-79667-3 · Cited by 64
Wess, G., Bauer, A., & Kopp, A. (2021) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.16089 · Cited by 59
Bennett, J. P., Liu, Y. E., Quon, B. K., Kelly, N. N., Wong, M. C., Kennedy, S. F., Chow, D. C., Garber, A. K., Weiss, E. J., Heymsfield, S. B., et al. (2021) · Clinical Nutrition · doi:10.1016/j.clnu.2021.11.031 · Cited by 64
Analyzing Dataset Annotation Quality Management in the Wild
Klie, J.-C., de Castilho, R. E., & Gurevych, I. (2024) · Computational Linguistics · doi:10.1162/coli_a_00516 · Cited by 139
Feng, Q., Bešević, J., Conroy, M. C., Omiyale, W., Lacey, B., & Allen, N. E. (2024) · Clinical Nutrition ESPEN · doi:10.1016/j.clnesp.2024.06.040 · Cited by 70
Barber, L. A., Barrett, R., & Lichtwark, G. A. (2011) · Journal of Anatomy · doi:10.1111/j.1469-7580.2011.01365.x · Cited by 62
Probst, M., Goris, M., Vandereycken, W., & Coppenolle, H. V. (2001) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/73.2.190 · Cited by 59
Jacobi, D., Perrin, A., Grosman, N., Doré, M., Normand, S., Oppert, J., & Simon, C. (2007) · Obesity · doi:10.1038/oby.2007.605 · Cited by 59
Reliability of and comparisons among three variations of the alternating cover test
Rainey, B. B., Schroeder, T. L., Goss, D. A., & Grosvenor, T. P. (1998) · Ophthalmic and Physiological Optics · doi:10.1016/s0275-5408(98)00002-7 · Cited by 59
Opolskiene, G., Sladkevicius, P., & Valentin, L. (2010) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.8871 · Cited by 59
Relative validity of adolescent dietary patterns: a comparison of a FFQ and 3 d food record
Ambrosini, G. L., O’Sullivan, T. A., de Klerk, N. H., Mori, T. A., Beilin, L. J., & Oddy, W. H. (2011) · British Journal Of Nutrition · doi:10.1017/s0007114510004137 · Cited by 68
Yamada, A., Luis, S. A., Sathianathan, D., Khandheria, B. K., Cafaro, J., Hamilton-Craig, C. R., Platts, D. G., Haseler, L. J., Burstow, D. J., & Chan, J. H. (2014) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.04.016 · Cited by 59
Knowles, J. W., Assimes, T. L., Tsao, P. S., Natali, A., Mari, A., Quertermous, T., Reaven, G. M., & Abbasi, F. (2013) · Metabolism · doi:10.1016/j.metabol.2012.10.002 · Cited by 60
Rauch, R., Welisch, E., Lansdell, N., Burrill, E., Jones, J., Robinson, T., Bock, D. E., Clarson, C. L., Filler, G., & Norozi, K. (2012) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-012-9412-7 · Cited by 62
Patel, P. J., Chen, F. K., da Cruz, L., & Tufail, A. (2009) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.08-1697 · Cited by 63
Interexaminer Repeatability of a New, Modified Prentice Card Compared with Established Phoria Tests
WONG, E. P. F., Fricke, T., & Dinardo, C. (2002) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2002.tb01486.x · Cited by 59
Lehmann, S., Hoofnagle, A., Hochstrasser, D., Brede, C., Glueckmann, M., Cocho, J. A., Ceglarek, U., Lenz, C., Vialaret, J., Scherl, A., et al. (2013) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm-2012-0723 · Cited by 59
Weintraub, A., Blau, H., Mussaffi, H., Picard, E., Bentur, L., Kerem, E., Stankiewicz, H., & Wilschanski, M. A. (2009) · Journal of Pediatric Gastroenterology and Nutrition · doi:10.1097/mpg.0b013e318180af4f · Cited by 59
Huschka, M. M., Mandrekar, S. J., Schaefer, P., Jett, J. R., & Sloan, J. A. (2007) · Cancer · doi:10.1002/cncr.22444 · Cited by 59
Lyons, J. G., Heeren, T., Stuver, S. O., & Fredman, L. (2014) · Journal of Aging and Health · doi:10.1177/0898264314556987 · Cited by 69
Rat, A., Pouchot, J., Coste, J., Baumann, C., Spitz, E., Retel-Rude, N., Baumann, M., Quintrec, J.-S. G.-L., Dumont‐Fischer, D., & Guillemin, F. (2006) · Joint Bone Spine · doi:10.1016/j.jbspin.2006.01.027 · Cited by 67
Automatic hippocampal segmentation in temporal lobe epilepsy: Impact of developmental abnormalities
Kim, H., Marie Chupin, A., Olivier Colliot, A., Bernhardt, B. C., Bernasconi, N., & Bernasconi, A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.11.040 · Cited by 66
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.