STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 8,301–8,400 of 47,868
The Reliability of Self-Reported Alcohol Consumption in the Remote Past
Longnecker, M. P., Newcomb, P. A., Mittendorf, R. L., Greenberg, E. R., Clapp, R., Bogdan, G., Willett, W. C., & MacMahon, B. (1992) · Epidemiology · doi:10.1097/00001648-199211000-00014 · Cited by 59
Optimization of self‐reference thermometry using complex field estimation
Kuroda, K., Kokuryo, D., Kumamoto, E., Suzuki, K., Matsuoka, Y., & Keserci, B. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21016 · Cited by 59
Swanson, P. A., Holzmayer, V., Huang, S., Hay, P., Adebiyi, A., Rice, P. S., Abravaya, K., Thamm, S., Devare, S. G., & Hackett, J. (2006) · Journal of Virological Methods · doi:10.1016/j.jviromet.2006.06.010 · Cited by 59
Agreement of central venous saturation and mixed venous saturation in cardiac surgery patients
Sander, M., Spies, C., Foer, A., Weymann, L., Braun, J. P., Volk, T. J., Grubitzsch, H., & von Heymann, C. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0684-1 · Cited by 59
Assessment of Body Composition in Elderly: Accuracy of Bioelectrical Impedance Analysis
Bussolotto, M., Ceccon, A., Sergi, G., Giantin, V., Benincà, P., & Enzi, G. (1999) · Gerontology · doi:10.1159/000022053 · Cited by 62
Body Composition and Health Status among Children and Adolescents
Freedman, D. S., & Perry, G. S. (2000) · Preventive Medicine · doi:10.1006/pmed.1998.0480 · Cited by 73
Kusanovic, J. P., Nien, J. K., Gonçalves, L. F., Espinoza, J., Lee, W., Balasubramaniam, M., Soto, E., Erez, O., & Romero, R. J. (2008) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.5242 · Cited by 59
Musuamba, F. T., Rousseau, A., Bosmans, J., Sennesael, J. J., Cumps, J., Marquet, P., Wallemacq, P. E., & Verbeeck, R. K. (2009) · Clinical Pharmacokinetics · doi:10.2165/11318060-000000000-00000 · Cited by 59
Bethune, M. P., & Bell, R. J. (2003) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.885 · Cited by 59
Jaber, W. A., White, R. D., Kuzmiak, S. A., Boyle, J. M., Natale, A., Apperson-Hansen, C., Thomas, J. D., & Asher, C. R. (2004) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2003.10.052 · Cited by 59
Short‐term reproducibility of cystometry and pressure‐flow micturition studies in healthy women
Brostrøm, S., Jennum, P., & Lose, G. (2002) · Neurourology and Urodynamics · doi:10.1002/nau.10019 · Cited by 59
Pittman, S. D., Pillar, G., Berry, R. B., Malhotra, A., MacDonald, M., & White, D. P. (2006) · Sleep And Breathing · doi:10.1007/s11325-006-0058-x · Cited by 62
Jarlsäter, S., & Mattsson, E. (2003) · Advances in Physiotherapy · doi:10.1080/14038190310004385 · Cited by 59
Paredi, P., Loukides, S., Ward, S. P., Cramer, D., Spicer, M., Kharitonov, S. A., & Barnes, P. J. (1998) · Thorax · doi:10.1136/thx.53.9.775 · Cited by 63
Engblom, H., Hedström, E., Heiberg, E., Wagner, G. S., Pahlm, O., & Arheden, H. (2005) · American Heart Journal · doi:10.1016/j.ahj.2005.07.022 · Cited by 59
Pereira, W. C. D. A., Bridal, S. L., Coron, A., & Laugier, P. (2004) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1295410 · Cited by 59
Rivera, J. M., Vandervoort, P. M., Mele, D., Siu, S. C., Morris, E. L., Weyman, A. E., & Thomas, J. D. (1994) · American Heart Journal · doi:10.1016/0002-8703(94)90056-6 · Cited by 59
Skeletal muscle changes in patients with obstructive sleep apnoea syndrome
Sauleda, J., García-Palmer, F., Tarraga, S., Maimó, A., Palou, A., & Agustí, A. G. N. (2003) · Respiratory Medicine · doi:10.1016/s0954-6111(03)00034-9 · Cited by 66
Assessment of Fluid Status in Peritoneal Dialysis Patients
Konings, C. J. A. M., Kooman, J. P., Schonck, M. J. M., Cox-Reijven, P. L. M., Kreel, B. V., Gladziwa, U., Wirtz, J. J. J. M., GERLAG, P. G. G., Hoorntje, S. J., Wolters, J., et al. (2002) · Peritoneal Dialysis International · doi:10.1177/089686080202200607 · Cited by 62
Kühl, H. P., Papavasiliu, T. S., Beek, A. M., Hofman, M. B. M., Heusen, N. S., & van Rossum, A. C. (2004) · Radiology · doi:10.1148/radiol.2302021120 · Cited by 62
Estimation of the extent of osteonecrosis of the femoral head using MRI
Kim, Y., Ahn, J. H., Kang, H. S., & Kim, H. J. (1998) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.80b6.0800954 · Cited by 59
Ultrasonic assessment of cortical bone thickness in vitro and in vivo
Karjalainen, J., Riekkinen, O., Töyräs, J., Kröger, H., & Jurvelin, J. (2008) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.918 · Cited by 73
Schaefer, W. M., Lipke, C. S. A., Nowak, B., Kaiser, H.-J., Reinartz, P., Buecker, A., Krombach, G. A., Buell, U., & Kühl, H. P. (2004) · PubMed · Cited by 59
Short-wavelength Automated Perimetry Without Lens Density Testing
Sample, P. A., Martinez, G. A., & Weinreb, R. N. (1994) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)76578-x · Cited by 59
Urine collection from disposable nappies
Ahmad, T., Vickers, D. W., Campbell, S., Coulthard, M. G., & PEDLER, S. J. (1991) · The Lancet · doi:10.1016/0140-6736(91)91242-m · Cited by 59
Calcitonin promotes osteoclast survival in vitro
Selander, K. S., Härkönen, P. L., Valve, E. M., Mönkkönen, J., Hannuniemi, R., & Väänänen, H. K. (1996) · Molecular and Cellular Endocrinology · doi:10.1016/0303-7207(96)03870-1 · Cited by 65
Technical Standardization for Dual-Energy X-Ray Absorptiometry
THEWRITINGGROUPFORTHEISCDPO (2004) · Journal of Clinical Densitometry · doi:10.1385/jcd:7:1:27 · Cited by 66
Evaluating Correlation with Proper Bounds
Shih, W., & Huang, W. (1992) · Biometrics · doi:10.2307/2532712 · Cited by 59
Radke, P. W., Klues, H. G., Haager, P. K., Hoffmann, R., Kastrau, F., Reffelmann, T., Janssens, U., Dahl, J. V., & Hanrath, P. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00151-5 · Cited by 59
The reliability of stroke outcome measures
Gompertz, P., Pound, P., & Ebrahim, S. (1993) · Clinical Rehabilitation · doi:10.1177/026921559300700404 · Cited by 58
Fluorescent microspheres are superior to radioactive microspheres in chronic blood flow measurements
van Oosterhout, M. F. M., Prinzen, F. W., Sakurada, S., Glenny, R. W., & Hales, J. R. S. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.275.1.h110 · Cited by 59
Topical ascorbate decreases the incidence of corneal ulceration after experimental alkali burns.
Pfister, R. R., Paterson, C. A., & Hayes, S. A. (1978) · PubMed · Cited by 65
Retinal vessel measurement: comparison between observer and computer driven methods
Newsom, R., Sullivan, P. M., Rassam, S., Jagoe, R., & KOHNER, E. M. (1992) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/bf00176292 · Cited by 59
Tang, S. T., Chen, J.-S., Wen, F.-H., Chou, W.-C., Chang, J. W.-C., Hsieh, C.-H., & Chen, C. H. (2019) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2018.7106 · Cited by 58
Black, L. J., Anderson, D. R., Clarke, M. W., Ponsonby, A., Lucas, R. M., & Ausimmune Investigator Group (2015) · PLoS ONE · doi:10.1371/journal.pone.0135478 · Cited by 67
New species of Cercopithecoides from Haasgat, North West Province, South Africa
McKee, J. K., von Mayer, A., & Kuykendall, K. L. (2010) · Journal of Human Evolution · doi:10.1016/j.jhevol.2010.08.002 · Cited by 58
Haggerty, C. M., Suever, J. D., Pulenthiran, A., Mejia-Spiegeler, A., Wehner, G. J., Jing, L., Charnigo, R. J., Fornwalt, B. K., & Fogel, M. A. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-017-0410-2 · Cited by 60
Rahimi, H., Twilt, M., Herlin, T., Spiegel, L. R., Pedersen, T. K., Küseler, A., & Stoustrup, P. B. (2018) · Pediatric Rheumatology · doi:10.1186/s12969-018-0259-4 · Cited by 58
Accuracy and reliability of a low-cost, handheld 3D imaging system for child anthropometry
Conkle, J., Suchdev, P. S., Alexander, E. J., Flores‐Ayala, R. C., Ramakrishnan, U., & Martorell, R. (2018) · PLoS ONE · doi:10.1371/journal.pone.0205320 · Cited by 62
Wang, Z., Zeng, Y., She, W., Luo, X., & Cai, L. (2018) · International Journal of Surgery · doi:10.1016/j.ijsu.2018.10.045 · Cited by 58
Deep learning reconstruction for cardiac magnetic resonance fingerprinting T1 and T2 mapping
Hamilton, J., Currey, D., Rajagopalan, S., & Seiberlich, N. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28568 · Cited by 58
Backhaus, S. J., Metschies, G., Billing, M., Schmidt-Rimpler, J., Kowallick, J. T., Gertz, R. J., Lapinskas, T., Pieske‐Kraigher, E., Pieske, B. M., Lotz, J., et al. (2021) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-021-00740-5 · Cited by 61
de Rijk, M. G., Slotegraaf, A. I., Brouwer-Brolsma, E. M., Perenboom, C. W. M., Feskens, E. J. M., & de Vries, J. H. M. (2021) · British Journal Of Nutrition · doi:10.1017/s0007114521004499 · Cited by 73
Vincent, S. J., Vincent, R. A., Shields, D., & Lee, G. A. (2011) · Clinical and Experimental Ophthalmology · doi:10.1111/j.1442-9071.2011.02670.x · Cited by 58
Sekiyama, J. Y., Camargo, C. Z., Andrade, L. E. C., & Kayser, C. (2013) · Arthritis Care & Research · doi:10.1002/acr.22054 · Cited by 58
Predicting maximal aerobic speed through set distance time-trials
Bellenger, C. R., FULLER, J. T., Nelson, M. J., Hartland, M., Buckley, J. D., & Debenedictis, T. A. (2015) · European Journal of Applied Physiology · doi:10.1007/s00421-015-3233-6 · Cited by 66
Chen, F. L., Hsiung, M. C., Nanda, N. C., Hsieh, K., & Chou, M. C. (2006) · Echocardiography · doi:10.1111/j.1540-8175.2006.00277.x · Cited by 58
The Use of Pedometers in Stroke Survivors: Are They Feasible and How Well Do They Detect Steps?
Carroll, S. L., Greig, C. A., Lewis, S. J., McMurdo, M. E. T., Sniehotta, F. F., Johnston, M., Johnston, D. W., Scopes, J., & Mead, G. E. (2012) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2011.08.047 · Cited by 72
Application of Ultrasound for Bone Age Estimation in Clinical Practice
Khan, K., Miller, B. S., Hoggard, E., Somani, A., & Sarafoglou, K. (2008) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2008.08.018 · Cited by 58
Effects of Fish Oil Supplementation on Markers of the Metabolic Syndrome
Pedersen, M. H., Mølgaard, C., Hellgren, L. I., & Lauritzen, L. (2010) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2010.04.001 · Cited by 62
Foster, B. J., Gao, T., Mackie, A. S., Zemel, B. S., Ali, H., Platt, R. W., & Colan, S. D. (2012) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2012.11.018 · Cited by 68
Fleming, P. S., Lee, R. T., Marinho, V. C., & Johal, A. (2013) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2013.03.012 · Cited by 58
The EPICure study: Comparison of pediatric spirometry in community and laboratory settings
Kirkby, J. C., Welsh, L., Lum, S., Fawke, J., Rowell, V., Thomas, S., Marlow, N., & Stocks, J. (2008) · Pediatric Pulmonology · doi:10.1002/ppul.20950 · Cited by 58
Gankande, T. U., Duke, J. M., Danielsen, P. L., DeJong, H. M., Wood, F. M., & Wallace, H. J. (2014) · Burns · doi:10.1016/j.burns.2014.01.025 · Cited by 58
Nightingale, C. M., Rudnicka, A. R., Owen, C. G., Donin, A. S., Newton, S. L., Furness, C. A., Howard, E. L., Gillings, R. D., Wells, J. C. K., Cook, D. G., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0076426 · Cited by 57
Rocchi, G., Bertini, M., Biffi, M., Ziacchi, M., Biagini, E., Gallelli, I., Martignani, C., Cervi, E., Ferlito, M., Rapezzi, C., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn483 · Cited by 58
Mallat, J., Lazkani, A., Lemyze, M., Pepy, F., Meddour, M., Gasan, G., Temime, J., Vangrunderbeeck, N., Tronchon, L., & Thévenin, D. (2015) · Medicine · doi:10.1097/md.0000000000000415 · Cited by 58
The impact of freezing and toasting on the glycaemic response of white bread
Burton, P., & Lightowler, H. J. (2007) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602746 · Cited by 68
A Modified ETDRS Visual Acuity Chart for European‐Wide Use
Plainis, S., Tzatzala, P., ORPHANOS, Y., & Tsilimbaris, M. K. (2007) · Optometry and Vision Science · doi:10.1097/opx.0b013e3180dc9a60 · Cited by 58
Zimmer, F., Zöllner, F. G., Hoeger, S., Klotz, S., Tsagogiorgas, C., Krämer, B. K., & Schad, L. R. (2013) · PLoS ONE · doi:10.1371/journal.pone.0053849 · Cited by 58
Sambuceti, G., Brignone, M., Marini, C., Massollo, M., Fiz, F., Morbelli, S. D., Buschiazzo, A., Campi, C., Piva, R., Massone, A. M., et al. (2012) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-012-2141-9 · Cited by 65
Green, D. W., Mogekwu, N. I., Scher, D. M., Handler, S., Chalmers, P. N., & Widmann, R. F. (2009) · Journal of Pediatric Orthopaedics · doi:10.1097/bpo.0b013e3181aa20cd · Cited by 58
Determination of creatinine in urine by tandem mass spectrometry
Húšková, R., Chrastina, P., Adam, T., & Schneiderka, P. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.07.007 · Cited by 58
The Relationship between Better-Eye and Integrated Visual Field Mean Deviation and Visual Disability
Arora, K. S., Boland, M. V., Friedman, D. S., Jefferys, J. L., West, S. K., & Ramulu, P. Y. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2013.07.020 · Cited by 65
Quality of Life Before Intensive Care Using EQ-5D: Patient Versus Proxy Responses*
Dinglas, V. D., Gifford, J. M., Husain, N., Colantuoni, E., & Needham, D. M. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e318265f340 · Cited by 64
Touboul, P., Vicaut, É., Labreuche, J., Belliard, J. P., Cohen, S., Kownator, S., & Pithois-Merli, I. (2004) · Cerebrovascular Diseases · doi:10.1159/000081913 · Cited by 58
Twenty-four Hour and Spot Urine Metabolic Evaluations: Correlations Versus Agreements
Hong, Y. H., Dublin, N., Razack, A. H. A., Mohd, M. A., & Husain, R. (2009) · Urology · doi:10.1016/j.urology.2009.08.061 · Cited by 62
Comparison of horizontal corneal diameter measurements using Galilei, EyeSys and Orbscan II systems
Salouti, R., Nowroozzadeh, M. H., Zamani, M., Ghoreyshi, M., & Salouti, R. (2009) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2009.00407.x · Cited by 58
Ragot, S., Genes, N., Vaur, L., & Herpin, D. (2000) · American Journal of Hypertension · doi:10.1016/s0895-7061(99)00258-7 · Cited by 58
The Usefulness of Waveform Score from the Ocular Response Analyzer
Lam, A. K. C., Chen, D., & Tse, J. S.-H. (2010) · Optometry and Vision Science · doi:10.1097/opx.0b013e3181d1d940 · Cited by 58
Grill, E., Mansmann, U., Cieza, A., & Stucki, G. (2007) · Acta Dermato Venereologica · doi:10.2340/16501977-0016 · Cited by 64
Wang, J.-S., Abboud, R. T., & Wang, L.-M. (2006) · CHEST Journal · doi:10.1378/chest.129.4.863 · Cited by 58
Pilcer, G., Vanderbist, F., & Amighi, K. (2008) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2008.02.014 · Cited by 58
Hawthorne, G. (2009) · Value in Health · doi:10.1111/j.1524-4733.2009.00526.x · Cited by 64
Intra- and inter-observer reliability of the Trunk Impairment Scale for children with cerebral palsy
Sæther, R., & Jørgensen, L. (2010) · Research in Developmental Disabilities · doi:10.1016/j.ridd.2010.11.007 · Cited by 68
Groh, G., Levy, P. T., Holland, M. R., Murphy, J. J., Sekarski, T. J., Myers, C., Hartman, D. P., Roiger, R. D., & Singh, G. K. (2013) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2013.09.016 · Cited by 58
Rothe, J. H., Grieser, C., Lehmkuhl, L., Schnapauff, D., Fernández, C. M. P., Maurer, M. H., Mußler, A., Hamm, B., Denecke, T., & Steffen, I. G. (2012) · European Journal of Radiology · doi:10.1016/j.ejrad.2012.05.018 · Cited by 58
Montalbán, R., ALIO, J. L., Javaloy, J., & Pinero, D. P. (2012) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2012.10.033 · Cited by 58
Isaksson, H., Töyräs, J., Hakulinen, M. A., Aula, A. S., Tamminen, I. S., Julkunen, P., Kröger, H., & Jurvelin, J. S. (2010) · Osteoporosis International · doi:10.1007/s00198-010-1219-0 · Cited by 68
Universal GFR determination based on two time points during plasma iohexol disappearance
Ng, D. K., Schwartz, G. J., Jacobson, L. P., Palella, F. J., Margolick, J. B., Warady, B. A., Furth, S. L., & Muñoz, Á. (2011) · Kidney International · doi:10.1038/ki.2011.155 · Cited by 58
EL-Ashry, M. F., Hegde, V., James, P. P., & Pagliarini, S. (2008) · Current Eye Research · doi:10.1080/02713680802323140 · Cited by 58
Roldan, L. J., Alén, J. F., Gómez, P. A., Lobato, R. D., Ramos, A., Munarriz, P. M., & Lagares, A. (2012) · Journal of neurosurgery · doi:10.3171/2012.8.jns12100 · Cited by 64
Sarker, S., Rudd, A. G., Douiri, A., & Wolfe, C. D. A. (2012) · Stroke · doi:10.1161/strokeaha.111.645234 · Cited by 58
Jansen, J. F. A., Kooi, M. E., Kessels, A. G. H., Nicolay, K., & Backes, W. H. (2007) · Investigative Radiology · doi:10.1097/01.rli.0000262757.10271.e5 · Cited by 60
Validation of a multi-sensor activity monitor for assessing sleep in children and adolescents
Sorić, M., Turkalj, M., Kučić, D., Marušić, I., Plavec, D., & Mišigoj‐Duraković, M. (2012) · Sleep Medicine · doi:10.1016/j.sleep.2012.11.003 · Cited by 65
The Effect of Optical Defocus on the Test–Retest Variability of Visual Acuity Measurements
Rosser, D. A., Murdoch, I., & Cousens, S. (2004) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.03-1320 · Cited by 58
A computed method for noninvasive MRI assessment of pulmonary arterial hypertension
Lankhaar, J., Noordegraaf, A. V., & Marcus, J. T. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00225.2004 · Cited by 58
A new method for measurement of gas exchange during anaesthesia using an extractable marker gas
Peyton, P. J., Robinson, G. J. B., Terry, D., & Junor, P. A. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/1/001 · Cited by 58
Intra-day and inter-day reliability of heart rate variability measurement
Cipryan, L., & Litschmannová, M. (2012) · Journal of Sports Sciences · doi:10.1080/02640414.2012.721931 · Cited by 70
McNair, P. J., Colvin, M., & Reid, D. A. (2010) · Arthritis Care & Research · doi:10.1002/acr.20368 · Cited by 58
Bley, T. A., Johnson, K. M., François, C. J., Reeder, S. B., Schiebler, M. L., Landgraf, B. R., Consigny, D. W., Grist, T. M., & Wieben, O. E. (2011) · Radiology · doi:10.1148/radiol.11101175 · Cited by 58
Youdas, J. W., Hollman, J. H., Aalbers, M. J., Ahrenholz, H. N., Aten, R. A., & Cremers, J. J. (2006) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2006.09.012 · Cited by 58
Blomqvist, S., Wester, A., Sundelin, G., & Rehn, B. (2011) · Physiotherapy · doi:10.1016/j.physio.2011.05.006 · Cited by 58
Takase, B., Goto, T., Hamabe, A., Uehata, A., Kuroda, K., Satomura, K., Ohsuzu, F., & Kurita, A. (2003) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001599 · Cited by 64
Prashar, A., Guggenheim, J. A., Erichsen, J. T., Hocking, P. M., & Morgan, J. E. (2007) · Experimental Eye Research · doi:10.1016/j.exer.2007.07.010 · Cited by 58
Age-related resistance to skeletal muscle fatigue is preserved during ischemia
Chung, L. H., Callahan, D. M., & Kent‐Braun, J. A. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00320.2007 · Cited by 66
On the physical and stochastic representation of an indicator dilution curve as a gamma variate
Mischi, M., den Boer, J. A., & Korsten, H. H. M. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/3/001 · Cited by 58
Subcutaneous Thigh Fat Assessment: A Comparison of Skinfold Calipers and Ultrasound Imaging
Selkow, N. M., Pietrosimone, B. G., & SALIBA, S. A. (2011) · Journal of Athletic Training · doi:10.4085/1062-6050-46.1.50 · Cited by 63
Larson, E., Aiello, A. E., Gomez-Duarte, C., Lin, S. X., Lee, L., Della‐Latta, P., & Lindhardt, C. (2003) · Food Microbiology · doi:10.1016/s0740-0020(03)00041-8 · Cited by 74
Khalil, A. A., D’Antonio, F., Dias, T., Cooper, D., & Thilaganathan, B. (2013) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.13253 · Cited by 63
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.