STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 8,901–9,000 of 47,868
Inter- and intrarater reliability of the Waterlow pressure sore risk scale: A systematic review
Kottner, J., Dassen, T. W. N., & Tannen, A. (2008) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2008.09.010 · Cited by 63
Reliability and validity of a new physical activity questionnaire for India
Anjana, R. M., Sudha, V., Lakshmipriya, N., Subhashini, S., Pradeepa, R., Geetha, L., Bai, M. R., Gayathri, R., Deepa, M., Ranjit Unnikrishnan, I., et al. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0196-2 · Cited by 60
Carlson, S. K., Classic, K. L., Hadac, E. M., Bender, C. E., Kemp, B. J., Lowe, V. J., Hoskin, T. L., & Russell, S. J. (2006) · Molecular Imaging and Biology · doi:10.1007/s11307-006-0058-z · Cited by 55
Neyestani, T. R., Gharavi, & Kalayi (2007) · International Journal for Vitamin and Nutrition Research · doi:10.1024/0300-9831.77.5.341 · Cited by 55
Hikihara, Y., Tanaka, C., Oshima, Y., Ohkawara, K., Ishikawa‐Takata, K., & Tanaka, S. (2014) · PLoS ONE · doi:10.1371/journal.pone.0094940 · Cited by 60
Lytrivi, I. D., Lai, W. W., Ko, H. H., Nielsen, J. C., Parness, I. A., & Srivastava, S. (2005) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2005.03.029 · Cited by 61
Short-Form 12 or Short-Form 36 to measure quality-of-life changes in dialysis patients?
Loosman, W. L., Hoekstra, T., van Dijk, S., Terwee, C. B., Honig, A., Siegert, C. E. H., & Dekker, F. W. (2015) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfv066 · Cited by 56
Effect of endocervical inflammation on days to conception in dairy cows
Deguillaume, L., Geffré, A., Desquilbet, L., Dizien, A., Thoumire, S., Vornière, C., Constant, F., Fournier, R., & Chastant‐Maillard, S. (2012) · Journal of Dairy Science · doi:10.3168/jds.2011-4602 · Cited by 55
Arcand, J., Floras, J. S., Azevedo, E., Mak, S. S., Newton, G. E., & Allard, J. P. (2010) · American Journal of Clinical Nutrition · doi:10.3945/ajcn.110.004457 · Cited by 55
Barcode lateral flow immunochromatographic strip for prostate acid phosphatase determination
Fang, C., Chen, Z., Li, L., & Xia, J.-H. (2011) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2011.08.008 · Cited by 55
on behalf of the Sloane Project Steering Group, Thomas, J. S. J., Evans, A. J., Macartney, J., Pinder, S. E., Hanby, A. M., Ellis, I. O., Kearins, O., Roberts, T. E., Clements, K., et al. (2010) · British Journal of Cancer · doi:10.1038/sj.bjc.6605513 · Cited by 62
Şahin, A., Başmak, H., & Yıldırım, N. (2008) · Journal of Glaucoma · doi:10.1097/ijg.0b013e31806ab33e · Cited by 55
Scheimpflug analysis of corneal power changes after myopic excimer laser surgery
Savini, G., Hoffer, K. J., Carbonelli, M., & Barboni, P. (2013) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2012.12.031 · Cited by 55
Harris, A. G., Sinitsina, I., & Messmer, K. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00475.2001 · Cited by 71
Chagunda, M. G. G., & Yan, T. (2011) · Animal Feed Science and Technology · doi:10.1016/j.anifeedsci.2011.02.005 · Cited by 65
Brichler, S., Gal, F. L., Butt, A., Chevret, S., & Gordien, E. (2013) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2013.01.025 · Cited by 57
Gjesdal, O., Vartdal, T., Hopp, E., Lunde, K., Brunvand, H., Smith, H., & Edvardsen, T. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2009.04.023 · Cited by 55
Validation of an Off‐Eye Contact Lens Shack‐Hartmann Wavefront Aberrometer
Kollbaum, P. S., Jansen, M. E., Thibos, L. N., & Bradley, A. (2008) · Optometry and Vision Science · doi:10.1097/opx.0b013e318185280e · Cited by 55
Phillips, R. A., Hood, S. G., Jacobson, B., West, M., Wan, L., & May, C. N. (2012) · Critical Care Research and Practice · doi:10.1155/2012/621496 · Cited by 61
Cooper, R. F., Langlo, C. S., Dubra, A., & Carroll, J. (2013) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12070 · Cited by 58
Evidence of an Early Physical Activity Reduction in Chronic Obstructive Pulmonary Disease Patients
Gouzi, F., PREFAUT, C. G., Abdellaoui, A., Vuillemin, A., Molinari, N., Ninot, G., Caris, G., & Hayot, M. (2011) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2011.05.012 · Cited by 61
Daily energy expenditure, physical activity, and weight loss in Parkinson's disease patients
Delikanaki-Skaribas, E., Trail, M., Wong, W. W., & Lai, E. C. (2008) · Movement Disorders · doi:10.1002/mds.22372 · Cited by 56
Anastasakis, A., McAnany, J. J., Fishman, G. A., & Seiple, W. (2010) · Eye · doi:10.1038/eye.2010.158 · Cited by 55
Tuuli, M. G., Houser, M. V., Odibo, L., Huster, K., Macones, G. A., & Odibo, A. O. (2010) · Placenta · doi:10.1016/j.placenta.2009.12.018 · Cited by 55
Mori, Y., Shiota, T., Jones, M., Wanitkun, S., Irvine, T., Li, X., Delabays, A., Pandian, N. G., & Sahn, D. J. (1999) · Circulation · doi:10.1161/01.cir.99.12.1611 · Cited by 55
An evaluation of the acidogenic potential of asthma inhalers
Tootla, R. G. H., Toumba, K. J., & Duggal, M. S. (2004) · Archives of Oral Biology · doi:10.1016/j.archoralbio.2003.11.006 · Cited by 55
Validation and Cross Cultural Adaptation of the Italian Version of the Harris Hip Score
Dettoni, F., Pellegrino, P., Russa, M. R. L., Bonasia, D. E., Blonna, D., Bruzzone, M., Castoldi, F., & Rossi, R. (2014) · Hip International · doi:10.5301/hipint.5000184 · Cited by 57
Respiratory rate assessments using a dual-accelerometer device
Lapi, S., Lavorini, F., Borgioli, G., Calzolai, M., Masotti, L. F., Pistolesi, M., & Fontana, G. A. (2013) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2013.11.003 · Cited by 55
Muscle architecture and EMG activity changes during isotonic and isokinetic eccentric exercises
Guilhem, G., Cornu, C., & Guével, A. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-1894-3 · Cited by 70
Ben-Shabat, E., Palit, M., Fini, N. A., Brooks, C. T., Winter, A., & Holland, A. E. (2013) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2013.06.026 · Cited by 58
Rutledge, J. M., Bush, A., Shekerdemian, L. S., Schulze‐Neick, I., Penny, D. J., Cai, S., & Li, J. (2010) · American Heart Journal · doi:10.1016/j.ahj.2010.04.003 · Cited by 55
Caliendo, A. M., Ingersoll, J., Fox-Canale, A. M., Pargman, S., Bythwood, T., Hayden, M. K., Bremer, J. W., & Lurain, N. S. (2007) · Journal of Clinical Microbiology · doi:10.1128/jcm.02558-06 · Cited by 55
Uebel, K., Pusch, K., Gedrich, K., Schneider, K.-T. M., Hauner, H., & Bader, B. (2014) · BMC Pregnancy and Childbirth · doi:10.1186/1471-2393-14-138 · Cited by 65
Medeiros, F. S. R., Sapienza, M. T., Prado, E. D. S., Agena, F., Shimizu, M. H. M., Lemos, F. B. C., Buchpiguel, C. A., Ianhez, L. E., & David‐Neto, E. (2008) · Transplant International · doi:10.1111/j.1432-2277.2008.00799.x · Cited by 66
Oda, S., Utsunomiya, D., Funama, Y., Awai, K., Katahira, K., Nakaura, T., Yanaga, Y., Namimoto, T., & Yamashita, Y. (2011) · Academic Radiology · doi:10.1016/j.acra.2011.03.007 · Cited by 55
Relationship between ciliary sulcus diameter and anterior chamber diameter and corneal diameter
Kawamorita, T., Uozato, H., Kamiya, K., & Shimizu, K. (2010) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2009.11.017 · Cited by 55
Jensen, T., Schou, S., Gundersen, H. J. G., Forman, J. L., Terheyden, H., & Holmstrup, P. (2012) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2012.02438.x · Cited by 55
Vaughan, K., & Miller, W. C. (2012) · Disability and Rehabilitation · doi:10.3109/09638288.2012.690498 · Cited by 62
Andreini, D., Pontone, G., Bartorelli, A. L., Trabattoni, D., Mushtaq, S., Bertella, E., Annoni, A. D., Formenti, A., Cortinovis, S., Montorsi, P., et al. (2009) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2009.01.343 · Cited by 55
Measuring Continuity of Care in Diabetes Mellitus: An Experience-Based Measure
Gulliford, M. C., Naithani, S., & Morgan, M. (2006) · The Annals of Family Medicine · doi:10.1370/afm.578 · Cited by 66
Giannattasio, C., Salvi, P., Valbusa, F., Kearney‐Schwartz, A., Capra, A., Amigoni, M., Failla, M., Boffi, L., Madotto, F., Benetos, A., et al. (2008) · Hypertension · doi:10.1161/hypertensionaha.108.116509 · Cited by 63
Mulhern, B. J., & Meadows, K. (2014) · Health and Quality of Life Outcomes · doi:10.1186/1477-7525-12-42 · Cited by 56
Paelinck, B. P., Herck, P. L. V., Rodrigus, I. E. R., Claeys, M. J., Laborde, J., Parizel, P. M., Vrints, C. J., & Bosmans, J. M. (2011) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2011.02.348 · Cited by 55
Validation of a smartphone-based measurement tool for the quantification of level walking
Furrer, M., Bichsel, L., Niederer, M., Baur, H., & Schmid, S. (2015) · Gait & Posture · doi:10.1016/j.gaitpost.2015.06.003 · Cited by 55
Pillow, J. J., Ljungberg, H., Hülskamp, G., & Stocks, J. (2004) · European Respiratory Journal · doi:10.1183/09031936.04.00091504 · Cited by 55
Eston, R. G., Evans, H., Faulkner, J., Lambrick, D., Al-Rahamneh, H. Q., & Parfitt, G. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-012-2326-8 · Cited by 70
Measuring Activity Levels at an Acute Stroke Ward: Comparing Observations to a Device
Kramer, S. F., Cumming, T. B., Churilov, L. P., & Bernhardt, J. (2013) · BioMed Research International · doi:10.1155/2013/460482 · Cited by 66
Kiadaliri, A., Eliasson, B., & Gerdtham, U. (2015) · Health and Quality of Life Outcomes · doi:10.1186/s12955-015-0344-z · Cited by 56
Seevaratnam, R., Patel, B. P., & Hamadeh, M. J. (2009) · The Journal of Biochemistry · doi:10.1093/jb/mvp037 · Cited by 55
Keil, S., Behrendt, F. F., Stanzel, S. F., Sühling, M., Koch, A. H., Bubenzer, J., Mühlenbruch, G., Mahnken, A. H., Günther, R. W., & Das, M. (2008) · European Radiology · doi:10.1007/s00330-008-1050-6 · Cited by 55
Reduction of biofilm on orthodontic brackets with the use of a polytetrafluoroethylene coating
Demling, A. P., Elter, C., Heidenblut, T., Bach, F.-W., Hahn, A., Schwestka‐Polly, R., Stiesch, M., & Heuer, W. (2010) · European Journal of Orthodontics · doi:10.1093/ejo/cjp142 · Cited by 66
Pereira, L. M., Dias, J. M., Mazuquin, B., Castanhas, L. G., Menacho, M. D. O., & Cardoso, J. R. (2013) · Brazilian Journal of Physical Therapy · doi:10.1590/s1413-35552012005000091 · Cited by 55
Planken, R. N., Keuter, X. H. A., Hoeks, A. P. G., Kooman, J. P., SANDE, F. M. V. D., Kessels, A. G. H., Leiner, T., & Tordoir, J. H. M. (2005) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfi340 · Cited by 55
Boldt, J., Kumle, B., Suttner, S., & Haisch, G. (2001) · Acta Anaesthesiologica Scandinavica · doi:10.1034/j.1399-6576.2001.450210.x · Cited by 55
RetractedDevelopment, dimensions, reliability and validity of the novel Manchester COPD fatigue scale
Al-shair, K., Kolsum, U., Berry, P., Smith, J. A., Caress, A., Singh, D., & Vestbo, J. (2009) · Thorax · doi:10.1136/thx.2009.118109 · Cited by 56
Hau, S., Papastefanou, V. P., Shah, S., Sagoo, M. S., Restori, M., & Cohen, V. M. L. (2014) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2014-305218 · Cited by 55
Read, J. C. A., Georgiou, R., Brash, C., Yazdani, P., Whittaker, R. G., Trevelyan, A. J., & Serrano‐Pedraza, I. (2015) · Journal of Vision · doi:10.1167/15.1.5 · Cited by 62
T1 at 1.5T and 3T compared with conventional T2* at 1.5T for cardiac siderosis
Alam, M. H., Auger, D., Smith, G. C., He, T., Vassiliou, V. S., Baksi, A. J., Wage, R., Drivas, P., Feng, Y., Firmin, D. N., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0207-0 · Cited by 58
Boer, P., & Moss, S. J. (2015) · Research in Developmental Disabilities · doi:10.1016/j.ridd.2015.10.022 · Cited by 55
Pulse Oximetry Overestimates Oxygen Saturation in COPD
Amalakanti, S., & Pentakota, M. R. (2015) · Respiratory Care · doi:10.4187/respcare.04435 · Cited by 66
Huck, C. J., Bronas, U. G., Williamson, E. B., Draheim, C. C., Duprez, D. A., & Dengel, D. R. (2007) · PubMed Central · Cited by 66
Richmond, S. A., Kang, J., Doyle–Baker, P. K., Nettel‐Aguirre, A., & Emery, C. A. (2015) · Clinical Journal of Sport Medicine · doi:10.1097/jsm.0000000000000261 · Cited by 78
Technique of Area Measurement of Epithelial Defects
Mukerji, N., Vajpayee, R. B., & Sharma, N. (2003) · Cornea · doi:10.1097/00003226-200308000-00012 · Cited by 55
Ball, T., Joy, E. A., Goh, T. L., Hannon, J. C., Gren, L. H., & Shaw, J. M. (2014) · Primary Health Care Research & Development · doi:10.1017/s1463423613000479 · Cited by 58
Fiat Lux: the effect of illuminance on acuity testing
Tidbury, L. P., Czanner, G., & Newsham, D. (2016) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-016-3329-7 · Cited by 55
van Lieshout, R., Reijneveld, E. A. E., Berg, S., Haerkens, G. M., Koenders, N., de Leeuw, A. J., van Oorsouw, R., Paap, D., Scheffer, E., Weterings, S., et al. (2016) · Europe PMC (PubMed Central) · Cited by 65
Comparison of 3 T and 1.5 T for T2* magnetic resonance of tissue iron
Alam, M. H., Auger, D., McGill, L., Smith, G. C., He, T., İzgi, C., Baksi, A. J., Wage, R., Drivas, P., Firmin, D. N., et al. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-016-0259-9 · Cited by 55
Tsikas, D., Rothmann, S., Schneider, J. Y., Gutzki, F., Beckmann, B., & Frölich, J. C. (2016) · Analytical Biochemistry · doi:10.1016/j.ab.2016.08.009 · Cited by 55
Wang, W., Liu, L., Chang, X., Jia, Z., Zhao, J., & Xu, W. (2016) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-016-1283-5 · Cited by 62
Vandermeulen, E., Lammertyn, E. J., Verleden, S. E., Ruttens, D., Bellon, H., Ricciardi, M., Somers, J., Bracke, K. R., den Eynde, K. V., Tousseyn, T., et al. (2016) · Transplant International · doi:10.1111/tri.12882 · Cited by 55
Bissinger, O., Probst, F., Wolff, K., Jeschke, A., Weitz, J., Deppe, H., & Kolk, A. (2017) · Journal Of Clinical Periodontology · doi:10.1111/jcpe.12693 · Cited by 67
Koepke, N., Zwahlen, M., Wells, J. C. K., Bender, N., Henneberg, M., Rühli, F. J., & Staub, K. (2017) · PeerJ · doi:10.7717/peerj.2980 · Cited by 60
Nerve regeneration by human corneal stromal keratocytes and stromal fibroblasts
Yam, G. H., Williams, G. P., Setiawan, M., Yusoff, N. Z. B. M., Lee, X.-W., Htoon, H. M., Zhou, L., Fuest, M., & Mehta, J. S. (2017) · Scientific Reports · doi:10.1038/srep45396 · Cited by 59
Costello, N., Deighton, K., Dyson, J., Mckenna, J., & Jones, B. (2017) · European Journal of Sport Science · doi:10.1080/17461391.2017.1337815 · Cited by 53
Comparison of Incremental Intermittent and Time Trial Testing in Age-Group Swimmers
Zacca, R., Azevedo, R. M. S., Silveira, R. P., Vilas‐Boas, J. P., Pyne, D. B., Castro, F. A. D. S., & Fernandes, R. J. (2017) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000002087 · Cited by 55
Busch, T., Sangen, A., Vanpoucke, F. J., & Wieringen, A. V. (2017) · Behavior Research Methods · doi:10.3758/s13428-017-0960-0 · Cited by 67
Yanagawa, M., Kusumoto, M., Johkoh, T., Noguchi, M., Minami, Y., Sakai, F., Asamura, H., Tomiyama, N., Awai, K., Minami, M., et al. (2017) · Clinical Lung Cancer · doi:10.1016/j.cllc.2017.12.005 · Cited by 55
Murias, J. M., Pogliaghi, S., & Paterson, D. H. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00143 · Cited by 74
Furness, J. W., Schram, B. L., Cox, A., Anderson, S. L., & Keogh, J. (2018) · PeerJ · doi:10.7717/peerj.4431 · Cited by 57
Evaluation of a short food frequency questionnaire for dietary intake assessment among children
Vilela, S., Severo, M., Moreira, T., Ramos, E., & Lopes, C. M. M. (2018) · European Journal of Clinical Nutrition · doi:10.1038/s41430-018-0200-4 · Cited by 71
Chelu, R. G., Horowitz, M., Suchá, D., Kardys, I., Ingremeau, D., Vasanawala, S. S., Nieman, K., Paul, J., & Hsiao, A. (2018) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-018-0702-z · Cited by 63
Precision and Accuracy of a Direct-Reading Miniaturized Monitor in PM2.5 Exposure Assessment
Borghi, F., Spinazzè, A., Campagnolo, D., Rovelli, S., Cattaneo, A., & Cavallo, D. M. (2018) · Sensors · doi:10.3390/s18093089 · Cited by 59
Kobayashi, S., Yuan, X., Sasaki, S., Osawa, Y., Hirata, T., Abe, Y., Takayama, M., Arai, Y., Masui, Y., & Ishizaki, T. (2018) · Public Health Nutrition · doi:10.1017/s1368980018002331 · Cited by 55
Non-Contact, Simple Neonatal Monitoring by Photoplethysmography
Cobos-Torres, J.-C., Abderrahim, M., & Martínez-Orgado, J. A. (2018) · Sensors · doi:10.3390/s18124362 · Cited by 57
Ablation Lesion Characterization in Scarred Substrate Assessed Using Cardiac Magnetic Resonance
Tao, S., Guttman, M. A., Fink, S., Elahi, H., Patil, K. D., Ashikaga, H., Kolandaivelu, A., Berger, R. D., Halushka, M. K., Schmidt, E. J., et al. (2018) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2018.11.001 · Cited by 55
In-Ear Pulse Rate Measurement: A Valid Alternative to Heart Rate Derived from Electrocardiography?
Passler, S., Müller, N., & Senner, V. (2019) · Sensors · doi:10.3390/s19173641 · Cited by 67
Kositsky, A., GONÇALVES, B. A. M., Stenroth, L., Barrett, R., Diamond, L. E., & Saxby, D. J. (2019) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2019.09.013 · Cited by 59
Zhu, K., Lv, T., Qin, T., Huang, Y., Wang, L., & Liu, B. (2019) · Chemical Communications · doi:10.1039/c9cc08015e · Cited by 55
Baeshen, A., Wyss, P. O., Henning, A., Tuura, R., Piccirelli, M., Kollias, S. S., & Michels, L. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26921 · Cited by 57
Fan, C., Fu, G., Noia, A. D., Smit, M., Rietjens, J. H. H., Ferrare, R. A., Burton, S. P., Li, Z., & Hasekamp, O. (2019) · Remote Sensing · doi:10.3390/rs11232877 · Cited by 59
Mariottoni, E. B., Jammal, A. A., Urata, C. N., Berchuck, S. I., Thompson, A. C., Estrela, T., & Medeiros, F. A. (2020) · Scientific Reports · doi:10.1038/s41598-019-57196-y · Cited by 58
Breda, S. J., van der Vlist, A. C., de Vos, R., Krestin, G. P., & Oei, E. H. G. (2020) · European Radiology · doi:10.1007/s00330-020-06952-0 · Cited by 62
Page, M. J., Moher, D., Fidler, F. M., Higgins, J. P. T., Brennan, S., Haddaway, N., Hamilton, D. G., Kanukula, R., Karunananthan, S., Maxwell, L. J., et al. (2021) · Systematic Reviews · doi:10.1186/s13643-021-01670-0 · Cited by 64
Abbott, J. H., Fritz, J. M., McCane, B., Shultz, B. B., Herbison, P., Lyons, B., Stefanko, G., & Walsh, R. M. (2006) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-7-45 · Cited by 55
Chuang, M. L., Beaudin, R. A., Riley, M. F., Mooney, M. G., Manning, W. J., Douglas, P. S., & Hibberd, M. G. (2000) · International journal of cardiac imaging · doi:10.1023/a:1026540809758 · Cited by 63
Mager, D. R., Wykes, L., Roberts, E. A., Ball, R. O., & Pencharz, P. B. (2006) · Journal of Nutrition · doi:10.1093/jn/136.1.133 · Cited by 60
Formula-Derived Prediction of the Glomerular Filtration Rate from Plasma Creatinine Concentration
Kemperman, F. A. W., Krediet, R. T., & Arisz, L. (2002) · The Nephron journals/Nephron journals · doi:10.1159/000065012 · Cited by 55
Piccoli, A., Codognotto, M., Pascoli, L. D., Boffo, G., & Caregaro, L. (2005) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607105029003148 · Cited by 64
Lai, K. N., Lai, K. B., Szeto, C., Ho, K. K. L., Poon, P., Lam, C. W. K., & Leung, J. C. K. (1997) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(97)90122-0 · Cited by 55
de Boorder, M. J., Hendrikse, J., & van der Grond, J. (2004) · Stroke · doi:10.1161/01.str.0000128530.75424.63 · Cited by 55
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.