STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 8,801–8,900 of 47,868
Andersen, H. (1996) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(96)90109-4 · Cited by 56
Hope, M. D., de la Peña-Almaguer, E., Yang, P. C.-M., Liang, D. H., McConnell, M. V., & Rosenthal, D. N. (2003) · Journal of the American Society of Echocardiography · doi:10.1067/s0894-7317(03)00400-0 · Cited by 56
Beerbaum, P., Sarikouch, S., Laser, K., Greil, G., Burchert, W., & Körperich, H. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21655 · Cited by 56
Aerobic exercise physiology in a professional rugby union team
Scott, A., Roe, N., Coats, A. J. S., & Piepoli, M. F. (2003) · International Journal of Cardiology · doi:10.1016/s0167-5273(02)00211-5 · Cited by 56
Felbinger, T. W., Reuter, D. A., Eltzschig, H. K., Mörstedt, K., Gödje, O. L., & Goetz, A. E. (2002) · Journal of Clinical Anesthesia · doi:10.1016/s0952-8180(02)00363-x · Cited by 56
Lydakis, C., Momen, A., Blaha, C., Gugoff, S., Gray, K. S., Herr, M. D., Leuenberger, U. A., & Sinoway, L. I. (2008) · Journal of Human Hypertension · doi:10.1038/jhh.2008.4 · Cited by 61
A Simplified Approach to the Diagnosis of Elevated Intra-abdominal Pressure
Lee, S. L., Anderson, J. T., Kraut, E. J., Wisner, D. H., & Wolfe, B. M. (2002) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-200206000-00024 · Cited by 56
Braun, M., Meta, M. D., Schneider, P. F., & Reiners, C. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/8/020 · Cited by 56
Baillard, C., Sylvie, B., Toumelin, P. L., Farid, A. K., Riou, B., Michel, C., & Samama, C. M. (2004) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000100150.84698.8c · Cited by 56
Gankande, T. U., Wood, F. M., Edgar, D. W., Duke, J. M., DeJong, H. M., Henderson, A. E., & Wallace, H. J. (2013) · Burns · doi:10.1016/j.burns.2013.01.014 · Cited by 57
Tsushima, Y., Blomley, M. J. K., OKABE, K., Tsuchiya, K., AOKI, J., & Endo, K. (2001) · The Journal of Urology · doi:10.1097/00005392-200102000-00007 · Cited by 56
Repeatability of corneal parameters with Pentacam after laser in situ keratomileusis
Grewal, S. P. S., Jain, R., & Grewal, D. S. (2007) · Indian Journal of Ophthalmology · doi:10.4103/0301-4738.33819 · Cited by 56
The families of anorexia nervosa and cystic fibrosis patients
Blair, C., Freeman, C., & Cull, A. (1995) · Psychological Medicine · doi:10.1017/s0033291700037478 · Cited by 57
Evaluation of Respiratory Inductive Plethysmography in Controlled Ventilation
Neumann, P., Zinserling, J., Haase, C., Sydow, M., & Burchardi, H. (1998) · CHEST Journal · doi:10.1378/chest.113.2.443 · Cited by 56
Auleley, G.-R. (2001) · British journal of rheumatology · doi:10.1093/rheumatology/40.4.414 · Cited by 56
An improved concordance correlation coefficient
Liao, J. J. Z. (2003) · Pharmaceutical Statistics · doi:10.1002/pst.52 · Cited by 56
Herbots, L., Maes, F., D’hooge, J., Claus, P., Dymarkowski, S., Mertens, P., Mortelmans, L., Bijnens, B. H., Bogaert, J. G., Rademakers, F. E., et al. (2004) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2004.02.003 · Cited by 56
Herpin, D., & Ragot, S. (1997) · American Journal of Hypertension · doi:10.1016/s0895-7061(97)00115-5 · Cited by 56
Shors, S. M., Fung, C. W., François, C. J., Finn, J. P., & Fieno, D. S. (2004) · Radiology · doi:10.1148/radiol.2302021309 · Cited by 58
Visual Acuity, Crowding, and Stereo-Vision Are Linked in Children with and without Amblyopia
Greenwood, J. A., Tailor, V., Sloper, J. J., Simmers, A. J., Bex, P. J., & Dakin, S. C. (2012) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.12-10313 · Cited by 71
Reliability of three-dimensional gait analysis in cervical spondylotic myelopathy
Malone, A., Bolger, C., Keating, L., McEvoy, L., & Meldrum, D. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2010.07.019 · Cited by 65
Clinical comparison of the Keeler Pulsair 3000 with Goldmann applanation tonometry
Parker, V., Herrtage, J., & Sarkies, N. J. (2001) · British Journal of Ophthalmology · doi:10.1136/bjo.85.11.1303 · Cited by 56
Growth rate of corpus callosum in very premature infants.
ANDERSON, N. G., Laurent, I., Cook, N., Woodward, L. J., & Inder, T. E. (2005) · PubMed · Cited by 56
Juergens, K. U., Seifarth, H., Range, F. T., Wienbeck, S., Wenker, M., Heindel, W. L., & Fischbach, R. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.2283 · Cited by 56
Analytical goals in therapeutic drug monitoring
Bowers, L. D. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.2.375 · Cited by 56
Scheffer, P. G., Bakker, S. J. L., Heine, R. J., & Teerlink, T. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.10.1904 · Cited by 59
T2 relaxation values in the developing preterm brain.
Counsell, S. J., Kennea, N. L., Herlihy, A. H., Allsop, J. M., Harrison, M. C., Cowan, F. M., Hajnal, J. V., Edwards, B., Edwards, A. D., & Rutherford, M. (2003) · Research Portal (King's College London) · Cited by 68
Bazzano, L. (2002) · American Journal of Epidemiology · doi:10.1093/aje/kwf003 · Cited by 56
Noninvasive measurement of midexpiratory flow indicates bronchoconstriction in allergic rats
Glaab, T., Hoymann, H.-G., Hohlfeld, J. M., Korolewitz, R., Hecht, M., Alarie, Y., Tschernig, T., Braun, A. C., Krug, N., & Fabel, H. (2002) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01121.2001 · Cited by 56
Changes in regional blood volume and blood flow during static handgrip
Stewart, J. M., Montgomery, L. D., Glover, J. L., & Medow, M. S. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00681.2006 · Cited by 60
Remmel, R. P., Kawle, S. P., Weller, D., & Fletcher, C. V. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.1.73 · Cited by 56
Electrodiagnosis of Carpal Tunnel Syndrome
Robinson, L. R. (2007) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/j.pmr.2007.07.008 · Cited by 56
Ratings of perceived exertion in braille: validity and reliability in production mode
Buckley, J. P., Eston, R. G., & Sim, J. (2000) · British Journal of Sports Medicine · doi:10.1136/bjsm.34.4.297 · Cited by 56
To clip or not to clip? Noseclips for spirometry
Chavasse, R. J. P. G., Johnson, P., Francis, J. M., Balfour-Lynn, I. M., Rosenthal, M., & Bush, A. (2003) · European Respiratory Journal · doi:10.1183/09031936.03.00048303 · Cited by 57
Walking speed on parquetry and carpet after stroke: effect of surface and retest reliability
Stephens, J. M., & Goldie, P. A. (1999) · Clinical Rehabilitation · doi:10.1191/026921599668553798 · Cited by 56
Agarwal, S. K., & Kumar, D. (2006) · CHEST Journal · doi:10.1378/chest.130.5.1454 · Cited by 60
Prediction of atrial fibrillation from surface ECG: review of methods and algorithms.
Poli, S., Barbaro, V., Bartolini, P., Calcagnini, G., & Censi, F. (2003) · PubMed · Cited by 56
Reproducibility of self-reported past body weight
Klipstein‐Grobusch, K., Kroke, A., & Boeing, H. (1998) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1600601 · Cited by 59
The use of live three-dimensional Doppler echocardiography in the measurement of cardiac output
Pemberton, J., Li, X., Karamlou, T., Sandquist, C. A., Thiele, K. E., Shen, I., Ungerleider, R. M., Kenny, A., & Sahn, D. J. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.10.046 · Cited by 56
Gastroesophageal pH step-up inaccurately locates proximal border of lower esophageal sphincter
Mattox, H. E., Richter, J. E., Sinclair, J. W., Price, J. E., & Case, L. D. (1992) · Digestive Diseases and Sciences · doi:10.1007/bf01296558 · Cited by 56
Weber, L. T., Hoecker, B., Armstrong, V. W., Oellerich, M., & Tönshoff, B. (2006) · Therapeutic Drug Monitoring · doi:10.1097/01.ftd.0000246766.12872.12 · Cited by 56
Pulsed Wave Doppler Measurement of Cardiac Output from the Right Ventricular Outflow Tract
Maslow, A. D., Comunale, M. E., Haering, J. M., & Watkins, J. (1996) · Anesthesia & Analgesia · doi:10.1097/00000539-199609000-00004 · Cited by 56
Aortic distensibility in children with the Marfan syndrome
Savolainen, A., Keto, P. E., Hekali, P. E., Nisula, L., Kaitila, I., Viitasalo, M. T., Poutanen, V.-P., Standertskjöld-Nordenstam, C.-G., & Kupari, M. M. (1992) · The American Journal of Cardiology · doi:10.1016/0002-9149(92)90215-k · Cited by 56
The utility of methacholine airway responsiveness measurements in evaluating anti-asthma drugs☆☆☆★★★
Inman, M. D., Hamilton, A. L., Kerstjens, H. A. M., Watson, R. M., & O’Byrne, P. M. (1998) · Journal of Allergy and Clinical Immunology · doi:10.1016/s0091-6749(98)70246-5 · Cited by 56
Stoddard, M. F., Prince, C. R., Ammash, N. M., GOAD, J., & Vogel, R. L. (1993) · American Heart Journal · doi:10.1016/0002-8703(93)90712-i · Cited by 56
Anie, K. A., Jones, P., Hilton, S. R., & ANDERSON, H. R. (1996) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(95)00583-8 · Cited by 56
The Fetal Doppler Mechanical PR Interval: A Validation Study
Glickstein, J. S., Buyon, J. P., Kim, M., & FRIEDMAN, D. M. (2003) · Fetal Diagnosis and Therapy · doi:10.1159/000074256 · Cited by 56
Latronico, N., Beindorf, A., Rasulo, F. A., Febbrari, P., Stefini, R., Cornali, C., & Candiani, A. (2000) · Neurosurgery · doi:10.1097/00006123-200005000-00021 · Cited by 62
Mayer, P., Meurice, J., Philip-Joet, F., Cornette, A., Rakotonanahary, D., Meslier, N., Pepin, J., Levy, P., & Veale, D. (1998) · European Respiratory Journal · doi:10.1183/09031936.98.12040770 · Cited by 57
Acharya, A. B., Bustani, P., Phillips, J. D., Taub, N. A., & Beattie, R. M. (1998) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/fn.78.2.f138 · Cited by 56
Han, T. S., & Lean, M. E. J. (1998) · British Journal of Nutrition · doi:10.1017/s0007114598001809 · Cited by 57
The euglycemic hyperinsulinemic clamp examination: variability and reproducibility
L. Bokemark, A. F. (2000) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365510050185010 · Cited by 56
Belfort, M. A., Tooke‐Miller, C., Varner, M. W., Saade, G., Grünewald, C., Nisell, H., & Herd, J. A. (2000) · Hypertension in Pregnancy · doi:10.1081/prg-100101995 · Cited by 56
Reproducibility of Fetal Lung Volume Measurements With 3‐Dimensional Ultrasonography
Sabogal, J. C., Becker, E., Bega, G., Komwilaisak, R., Berghella, V., Weiner, S., & Tolosa, J. E. (2004) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2004.23.3.347 · Cited by 56
Haemodynamic dose-efficacy of levosimendan in healthy volunteers
Lilleberg, J., NIEMINEN, M., Sundberg, S., Häyhä, M., & Akkila, J. (1994) · European Journal of Clinical Pharmacology · doi:10.1007/bf02570507 · Cited by 56
Mallouhi, A., Schocke, M., Judmaier, W., Wolf, C., Dessl, A., Czermak, B. V., Waldenberger, P., & Jaschke, W. R. (2002) · Radiology · doi:10.1148/radiol.2231010858 · Cited by 56
Evaluation of a symmetrically disposed Pitot tube flowmeter for measuring gas flow during exercise
Pórszász, J., Barstow, T. J., & Wasserman, K. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2659 · Cited by 56
Camplejohn, R. S., Macartney, J. C., & Morris, R. W. (1989) · Cytometry · doi:10.1002/cyto.990100408 · Cited by 56
Bijur, P. E., Shah, P. D., & Esses, D. (2016) · Emergency Medicine Journal · doi:10.1136/emermed-2015-205122 · Cited by 55
Naycheva, L., Schatz, A., Röck, T., Willmann, G., Messias, A., Bartz-Schmidt, K. U., Zrenner, E., & Gekeler, F. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.12-9612 · Cited by 55
Koide, Y., Yotsukura, M., Ando, H., Aoki, S., Suzuki, T., Sakata, K., Ootomo, E., & Yoshino, H. (2008) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2008.04.065 · Cited by 55
Wetter, A., Lipponer, C., Nensa, F., Heusch, P., Rubben, H., Altenbernd, J., Schlosser, T. W., Bockisch, A., Pöppel, T. D., Lauenstein, T. C., et al. (2013) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-013-2560-2 · Cited by 59
Park, S., Kim, Y., Choi, J., Pak, H., Kim, Y., & Shim, W. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2009.12.019 · Cited by 55
Hovorka, R., Nodale, M., Haidar, A., & Wilinska, M. E. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0185 · Cited by 61
Comparison of Physician‐Based and Patient‐Based Criteria for the Diagnosis of Fibromyalgia
Wolfe, F., Fitzcharles, M., Goldenberg, D. L., Häuser, W., Katz, R. L., Mease, P. J., Russell, A. S., Jon Russell, I., & Walitt, B. (2016) · Arthritis Care & Research · doi:10.1002/acr.22742 · Cited by 36
Tobler-Ammann, B., de Bruin, E. D., Fluet, M.-C., Lambercy, O., de Bie, R. A., & Knols, R. H. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0116-y · Cited by 55
FastVentricle: Cardiac Segmentation with ENet
Lieman-Sifry, J., Lê, M., Lau, F., Sall, S., & Golden, D. I. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-59448-4_13 · Cited by 66
Lai, C. T., Gardner, H., & Geddes, D. T. (2018) · Nutrients · doi:10.3390/nu10091218 · Cited by 55
Dimairo, M., Coates, E., Pallmann, P., Todd, S., Julious, S. A., Jaki, T., Wason, J., Mander, A. P., Weir, C. J., Koenig, F., et al. (2018) · BMC Medicine · doi:10.1186/s12916-018-1196-2 · Cited by 56
Self-citationZheng, S., Chang, W., Xu, W., Xu, Y., & Fu, L. (2019) · Frontiers in Chemistry · doi:10.3389/fchem.2019.00035 · Cited by 56
The stability of blood Eosinophils in chronic obstructive pulmonary disease
Long, G., Southworth, T. W., Kolsum, U., Donaldson, G. C., Wedzicha, J. A., Brightling, C. E., & Singh, D. (2020) · Respiratory Research · doi:10.1186/s12931-020-1279-4 · Cited by 55
A Novel Quantitative Index of Meibomian Gland Dysfunction, the Meibomian Gland Tortuosity
Lin, X., Fu, Y., Li, L., Chen, C., Chen, X., Mao, Y., Lian, H., Yang, W., & Dai, Q. (2020) · Translational Vision Science & Technology · doi:10.1167/tvst.9.9.34 · Cited by 55
SonoPODography: A new diagnostic technique for visualizing superficial endometriosis
Leonardi, M., Robledo, K. P., Espada, M., Vanza, K., & Condous, G. S. (2020) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2020.08.051 · Cited by 61
Hardcastle, S. J., Castuera, R. J., Maxwell‐Smith, C., Bulsara, M. K., & Hince, D. (2020) · PLoS ONE · doi:10.1371/journal.pone.0240967 · Cited by 62
Park, D., Choi, M.-K., Park, Y. K., Park, C. Y., & Shin, M. (2022) · Nutrition Research and Practice · doi:10.4162/nrp.2022.16.2.272 · Cited by 64
Hang, J., Shi, D., Neufeld, J., Bett, K. E., & House, J. D. (2022) · LWT · doi:10.1016/j.lwt.2022.113669 · Cited by 65
Maximal strength measurement: A critical evaluation of common methods—a narrative review
Warneke, K., Wagner, C., Keiner, M., Hillebrecht, M., Schiemann, S., Behm, D. G., Wallot, S., & WIRTH, K. J. (2023) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2023.1105201 · Cited by 71
Ott, C., Haetinger, S., Schneider, M. P., Pauschinger, M., & Schmieder, R. E. (2012) · The Journal of Clinical Hypertension · doi:10.1111/j.1751-7176.2012.00682.x · Cited by 55
Jepsen, J. R., Laursen, L. H., Hagert, C.-G., Kreiner, S., & Larsen, A. I. (2006) · BMC Neurology · doi:10.1186/1471-2377-6-8 · Cited by 56
Renal function assessment in older adults
Maanen, A. C. D., Jansen, P. A. F., Proost, J. H., Egberts, T. C. G., van Zuilen, A. D., van der Stap, D., & van Marum, R. J. (2013) · British Journal of Clinical Pharmacology · doi:10.1111/bcp.12199 · Cited by 63
Ismail, A. K., Ghafar, M. A. A., Shamsuddin, N. S. A., Roslan, N. A. M., Kaharuddin, H., & Muhamad, N. A. N. (2015) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2015.02.043 · Cited by 61
Improved Method for Calculating Hepatic Steatosis Using the Hepatorenal Index
Shiralkar, K. G., Johnson, S. I., Bluth, E. I., Marshall, R. H., Dornelles, A. C., & Gulotta, P. M. (2015) · Journal of Ultrasound in Medicine · doi:10.7863/ultra.34.6.1051 · Cited by 58
McKibben, R. A., Zhao, D., Lutsey, P. L., Schneider, A. L. C., Güallar, E., Mosley, T. H., & Michos, E. D. (2015) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2015-1711 · Cited by 57
Miszkiewicz, J. J., & Mahoney, P. (2015) · The Anatomical Record · doi:10.1002/ar.23285 · Cited by 63
Transcutaneous electromyography of the diaphragm: A cardio-respiratory monitor for preterm infants
Kraaijenga, J. V., Hutten, G. J., de Jongh, F. H., & van Kaam, A. H. (2014) · Pediatric Pulmonology · doi:10.1002/ppul.23116 · Cited by 55
A kinematic method to detect foot contact during running for all foot strike patterns
Milner, C. E., & Paquette, M. R. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.07.036 · Cited by 55
Greig, J. E., Thurtle, N., Cooney, L., Ariti, C. A., Ahmed, A. O., Ashagre, T., Ayela, A., Chukwumalu, K., Criado-Perez, A., Gómez-Restrepo, C., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0093716 · Cited by 60
A comparison of MR based segmentation methods for measuring brain atrophy progression
de Bresser, J., Portegies, M., Leemans, A., Biessels, G. J., Kappelle, L. J., & Viergever, M. A. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.09.060 · Cited by 56
Guo, Y., Yang, Z., Ning, G., Rao, L., Li, D., Pen, Y., Zhang, T., Wu, Y., Zhang, X., & Wang, Q. (2009) · Radiology · doi:10.1148/radiol.2522081714 · Cited by 55
Shanks, M., Delgado, V., Ng, A. C. T., van der Kley, F., Schuijf, J. D., Boersma, E. H., de Veire, N. R. L. V., Nucifora, G., Bertini, M., Roos, A., et al. (2010) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2010.06.116 · Cited by 55
Measuring Refraction in Adults in Epidemiological Studies
Krantz, E. M. (2010) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2009.349 · Cited by 55
Stadlbauer, A., van der Riet, W., Crelier, G. R., & Salomonowitz, E. K. (2009) · European Journal of Radiology · doi:10.1016/j.ejrad.2009.06.009 · Cited by 55
Armstrong, R. A., Ellis, W., Hamilton, R. L., Mackenzie, I. R. A., Hedreen, J., Gearing, M., Montine, T., Vonsattel, J.-P., Head, E., Lieberman, A. P., et al. (2010) · Journal of Neural Transmission · doi:10.1007/s00702-009-0350-6 · Cited by 55
A comparison of four self-report scales of pain intensity in 6- to 8-year-old children
Sánchez‐Rodríguez, E., Miró, J., & Castarlenas, E. (2012) · Pain · doi:10.1016/j.pain.2012.05.007 · Cited by 59
Estimation of pain intensity in emergency medicine: A validation study
Daoust, R., Beaulieu, P., Manzini, C., Chauny, J., & Lavigne, G. J. (2008) · Pain · doi:10.1016/j.pain.2008.02.007 · Cited by 62
Evaluation of activity monitors in manual wheelchair users with paraplegia
Hiremath, S. V., & Ding, D. (2011) · Journal of Spinal Cord Medicine · doi:10.1179/107902610x12911165975142 · Cited by 64
Furlan, J. C., Fehlings, M. G., Massicotte, E. M., Aarabi, B., Vaccaro, A. R., Bono, C. M., Madrazo, I., Villanueva, C., Grauer, J. N., & Mikulis, D. J. (2007) · Spine · doi:10.1097/brs.0b013e318145a91c · Cited by 55
Berkenbosch, J. W., & Tobias, J. D. (2002) · Critical Care Medicine · doi:10.1097/00003246-200205000-00011 · Cited by 55
Transcutaneous Bilirubin After Phototherapy in Term and Preterm Infants
Grabenhenrich, J., Grabenhenrich, L., Bührer, C., & Berns, M. (2014) · PEDIATRICS · doi:10.1542/peds.2014-1677 · Cited by 55
Right ventricular systolic function and cardiac resynchronization therapy
Burri, H., Domenichini, G., Sunthorn, H., Fleury, E., Stettler, C., Foulkes, I., & Shah, D. C. (2009) · EP Europace · doi:10.1093/europace/eup401 · Cited by 55
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.