Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 9,001–9,100 of 47,868
Alterations in Endothelial Cell Density After Photorefractive Keratectomy With Adjuvant Mitomycin
Diakonis, V. F., Pallikaris, A. I., Kymionis, G. D., & Markomanolakis, M. M. (2007) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2007.03.039 · Cited by 55
Bertoli, S., Petroni, M. L., Pagliato, E., Mora, S., Weber, G., Chiumello, G., & Testolin, G. (2005) · Journal of Pediatric Gastroenterology and Nutrition · doi:10.1097/01.mpg.0000153004.53610.0e · Cited by 66
Emerman, C. L., & Cydulka, R. K. (1996) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(96)70317-7 · Cited by 55
Bollmann, A., Husser, D., Stridh, M., SOERNMO, L., Majic, M., Klein, H., & Olsson, S. B. (2003) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540.8167.90305.x · Cited by 55
F e NO: Relationship to Exhalation Rates and Online versus Bag Collection in Healthy Adolescents
Kissoon, N. “., Duckworth, L. J., Blake, K., Murphy, S. P., TAYLOR, C. L., & Silkoff, P. E. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.2.9909124 · Cited by 55
Matthan, N. R., Raeini−Sarjaz, M., Lichtenstein, A. H., Ausman, L. M., & Jones, P. J. H. (2000) · Lipids · doi:10.1007/s11745-000-0616-9 · Cited by 63
Wang, Z., Heymsfield, S. B., Chen, Z., Zhu, S., & Pierson, R. N. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/9/013 · Cited by 55
mtDNA lineage analyses: Origins and migrations of Micronesians and Polynesians
Koji Lum, J., & Cann, R. L. (2000) · American Journal of Physical Anthropology · doi:10.1002/1096-8644(200010)113:2<151::aid-ajpa2>3.0.co;2-n · Cited by 111
Nebivolol improves coronary flow reserve in hypertensive patients without coronary heart disease
Galderisi, M., Cicala, S., D’Errico, A., DIVITIIS, O. D., & SIMONE, G. D. (2004) · Journal of Hypertension · doi:10.1097/00004872-200411000-00024 · Cited by 55
Karunanithi, M., & Feneley, M. P. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00566-5 · Cited by 55
Validation of "nine equivalents of nursing manpower use score" on an independent data sample
Rothen, H. U., Küng, V., Ryser, D. H., Zürcher, R. M., & Regli, B. (1999) · Intensive Care Medicine · doi:10.1007/s001340050910 · Cited by 55
Wingstrand, A., Lind, P., Haugegaard, J., Henriksen, S. A., Bille‐Hansen, V., & Sørensen, V. (1997) · Veterinary Parasitology · doi:10.1016/s0304-4017(97)00034-4 · Cited by 55
Hughes, M. L., Shekerdemian, L. S., Brizard, C. P., & Penny, D. J. (2004) · Heart · doi:10.1136/hrt.2003.016675 · Cited by 55
Relative Validity and Repeatability of a New Questionnaire on Physical Activity
Pols, M. A., Peeters, P. H. M., Ocké, M. C., Bueno-de-Mesquita, H. B., Slimani, N., Kemper, H. C. G., & Collette, H. J. A. (1997) · Preventive Medicine · doi:10.1006/pmed.1996.9995 · Cited by 55
Portable Exhaled Nitric Oxide as a Screening Tool for Asthma in Young Adults During Pollen Season
Κostikas, Κ., Papaioannou, A. Ι., Tanou, K., Koutsokera, A., Papala, M., & Gourgoulianis, K. I. (2007) · CHEST Journal · doi:10.1378/chest.07-1561 · Cited by 57
Bermejo, J., Antoranz, J. C., Yotti, R., Moreno, M., & Fernández, M. Á. G. (2001) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00349-0 · Cited by 55
Hospital Readmission Among Long-term Ventilator Patients
Douglas, S. L., Daly, B. J., Brennan, P. F., Gordon, N. H., & Uthis, P. (2001) · CHEST Journal · doi:10.1378/chest.120.4.1278 · Cited by 55
Detection and size of pulmonary lesions: how accurate is MRI? A prospective comparison of CT and MRI
Heye, T. J., Ley, S., Heußel, C. P., Dienemann, H., Kauczor, H., Hosch, W., & Libicher, M. (2012) · Acta Radiologica · doi:10.1258/ar.2011.110445 · Cited by 55
Fruehauf, H., Goetze, O., Steingoetter, A., Kwiatek, M. A., Boesiger, P., Thumshirn, M., Schwizer, W., & Fried, M. (2007) · Neurogastroenterology & Motility · doi:10.1111/j.1365-2982.2007.00904.x · Cited by 57
Hinwood, A. L., Sim, M. R., de Klerk, N. H., Drummer, O. H., Gerostamoulos, J., & Bastone, E. B. (2002) · Environmental Research · doi:10.1006/enrs.2002.4339 · Cited by 55
Ambrosini, G., Mackerras, D., de Klerk, N., & Musk, A. (2003) · Public Health Nutrition · doi:10.1079/phn2002434 · Cited by 56
Henneman, M. M., Schuijf, J. D., Jukema, J. W., Lamb, H. J., Roos, A., Dibbets, P., Stokkel, M. P. M., van der Wall, E. E., & Bax, J. J. (2006) · Heart · doi:10.1136/hrt.2006.087874 · Cited by 55
A Simple and Reliable Method for Clinical Assessment of Odor Thresholds
Lötsch, J., Lange, C., & Hummel, T. (2004) · Chemical Senses · doi:10.1093/chemse/bjh034 · Cited by 66
A comparison of methods of assessment of dietary selenium intakes in Otago, New Zealand
Duffield‐Lillico, A. J., & Thomson, C. D. (1999) · British Journal Of Nutrition · doi:10.1017/s0007114599001282 · Cited by 55
Scioscia, M., Scioscia, F., Vimercati, A., Caradonna, F., Nardelli, C., Pinto, L. R., & Selvaggi, L. E. (2008) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.5253 · Cited by 61
Zechner, W., Watzak, G., Gahleitner, A., Busenlechner, D., Tepper, G., & Watzek, G. (2003) · PubMed · Cited by 55
Poole, S. G., Dooley, M. J., & Rischin, D. (2002) · Annals of Oncology · doi:10.1093/annonc/mdf236 · Cited by 55
Comparative analysis of long-term biofilm formation on metal and ceramic brackets
Lindel, I. D., Elter, C., Heuer, W., Heidenblut, T., Stiesch, M., Schwestka‐Polly, R., & Demling, A. P. (2011) · The Angle Orthodontist · doi:10.2319/102210-616.1 · Cited by 67
Hardy, J., Bélisle, S. J., Robitaille, D., Perrault, J., Roy, M., & Gagnon, L. (1996) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(96)70191-5 · Cited by 55
Dual-energy X-ray absorptiometry–based body volume measurement for 4-compartment body composition
Wilson, J. P., Mulligan, K., Fan, B., Sherman, J., Murphy, E. J., Tai, V., Powers, C., Marquez, L., Ruiz-Barros, V., & Shepherd, J. (2011) · American Journal of Clinical Nutrition · doi:10.3945/ajcn.111.019273 · Cited by 66
Bougault, V., Lonsdorfer‐Wolf, E., Charloux, A., Richard, R., Gény, B., & Oswald–Mammosser, M. (2005) · CHEST Journal · doi:10.1016/s0012-3692(15)34456-1 · Cited by 55
Lutz, A. M., Willmann, J. K., Pfammatter, T., Lachat, M. L., Wildermuth, S., Marinček, B., & Weishaupt, D. (2003) · Journal of Vascular Surgery · doi:10.1067/mva.2003.143 · Cited by 55
DeRyke, C. A., Kuti, J. L., & Nicolau, D. P. (2007) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/j.diagmicrobio.2007.01.004 · Cited by 55
Visser, F. W., Muntinga, J. H. J., Dierckx, R. A. J. O., & Navis, G. J. (2008) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.05501207 · Cited by 55
The relationship between marijuana initiation and dropping out of high school
Bray, J. W., Zarkin, G. A., Ringwalt, C., & Qi, J. (2000) · Health Economics · doi:10.1002/(sici)1099-1050(200001)9:1<9::aid-hec471>3.0.co;2-z · Cited by 189
Transcutaneous Carbon Dioxide Monitoring and Capnography During Pediatric Polysomnography
Kirk, V. G., Batuyong, E. D., & Bohn, S. G. (2006) · SLEEP · doi:10.1093/sleep/29.12.1601 · Cited by 55
A Standardized Digital Photography System with Computerized Eyelid Measurement Analysis
Coombes, A., Sethi, C. S., Kirkpatrick, W. N. A., Waterhouse, N., Kelly, M. H., & Joshi, N. (2007) · Plastic & Reconstructive Surgery · doi:10.1097/01.prs.0000270315.53241.10 · Cited by 55
Hayano, J., Sakata, S., Okada, A., Mukai, S., & Fujinami, T. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00429-4 · Cited by 55
Home blood pressure normalcy: The Didima study
Stergiou, G. S., Thomopoulou, G. C., Skeva, I. I., & Mountokalakis, T. D. (2000) · American Journal of Hypertension · doi:10.1016/s0895-7061(99)00266-6 · Cited by 51
A Method for the Standardized Offline Collection of Exhaled Nitric Oxide
Silkoff, P. E., Stevens, A. D., Pak, J., Bucher‐Bartelson, B., & Martin, R. J. (1999) · CHEST Journal · doi:10.1378/chest.116.3.754 · Cited by 55
Transesophageal Echocardiography in Myocardial Revascularization
Bergquist, B. D., Leung, J. M., & Bellows, W. H. (1996) · Anesthesia & Analgesia · doi:10.1097/00000539-199606000-00006 · Cited by 55
Estimating Mean Glomerular Volume Using Two Arbitrary Parallel Sections
Najafian, B., Basgen, J. M., & Mauer, M. S. (2002) · Journal of the American Society of Nephrology · doi:10.1097/01.asn.0000033381.53882.25 · Cited by 55
A new doppler method for quantification of volumetric flow: In vivo validation using color doppler
Kim, W. Y., Poulsen, J. K., Terp, K., & Staalsen, N.-H. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00435-1 · Cited by 55
WATSON, S., WENZEL, R., DIMATTEO, C., Meier, B., & Lüscher, T. F. (1998) · American Journal of Hypertension · doi:10.1016/s0895-7061(98)00188-5 · Cited by 60
Triedman, J. K., & Saul, J. P. (1994) · The Journal of Clinical Monitoring · doi:10.1007/bf01651461 · Cited by 55
Egbagbe, E. E., Pavord, I. D., Wilding, P., Coon, J. T., & Tattersfield, A. (1997) · Thorax · doi:10.1136/thx.52.3.239 · Cited by 55
Mario, C. D., Haase, J., den Boer, A., Reiber, J. H. C., & Serruys, P. W. J. C. (1992) · American Heart Journal · doi:10.1016/0002-8703(92)90398-f · Cited by 55
Manometry of esophageal varices: Comparison of an endoscopic balloon technique with needle puncture
Gertsch, P., Fischer, G., Kleber, G., Wheatley, A. M., Geigenberger, G., & Sauerbruch, T. (1993) · Gastroenterology · doi:10.1016/0016-5085(93)90962-c · Cited by 55
Nakatani, S., Garcia, M. J., Firstenberg, M. S., Rodríguez, L., Grimm, R. A., Greenberg, N. L., McCarthy, P. M., Vandervoort, P. M., & Thomas, J. D. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00263-6 · Cited by 55
Two- and Three-Dimensional CT Ventriculography
Mochizuki, T., Murase, K., Higashino, H., Koyama, Y., Doi, M., Miyagawa, M., Nakata, S., Shimizu, K., & Ikezoe, J. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.174.1.1740203 · Cited by 55
Nielsen, B. M., Dencker, M., Ward, L., Linden, C., Thorsson, O., Karlsson, M. K., & Heitmann, B. L. (2007) · Diabetes, Obesity and Metabolism · doi:10.1111/j.1463-1326.2006.00634.x · Cited by 54
Step count accuracy and reliability of two activity tracking devices in people after stroke
Schaffer, S. D., Holzapfel, S. D., Fulk, G., & Bosch, P. R. (2017) · Physiotherapy Theory and Practice · doi:10.1080/09593985.2017.1354412 · Cited by 54
Napolitano, R., Donadono, V., Ohuma, E. O., Knight, C. L., Wanyonyi, S. Z., Kemp, B., Norris, T., & Papageorghiou, A. T. (2016) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.15956 · Cited by 54
Ng, D. K., Chan, C.-H., Chan, E. Y.-T., Kwok, K., Chow, P.-Y., Lau, W.-F., & Ho, J. C. (2005) · American Journal of Infection Control · doi:10.1016/j.ajic.2005.01.003 · Cited by 54
Tamura, S., Nishii, T., Shiomi, T., Yamazaki, Y., Murase, K., Yoshikawa, H., & Sugano, N. (2012) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2012.03.015 · Cited by 56
Measurement of limb volume: Laser scanning versus volume displacement
McKinnon, J. G., Wong, V., TEMPLE, W. J., Galbraith, C., Ferry, P., Clynch, G., & Clynch, C. (2007) · Journal of Surgical Oncology · doi:10.1002/jso.20790 · Cited by 54
Reproducibility and validity of an FFQ developed for adults in Nanjing, China
Ye, Q., Hong, X., Wang, Z., Yang, H., Chen, X., Zhou, H., Wang, C., Lai, Y., Sun, L., & Xu, F. (2016) · British Journal Of Nutrition · doi:10.1017/s0007114515005334 · Cited by 54
Marshall, S. J., Livingstone, K. M., Celis-Morales, C. A., Forster, H., Fallaize, R., O’Donovan, C. B., Woolhead, C., Marsaux, C. F. M., Macready, A. L., Navas‐Carretero, S., et al. (2016) · Journal of Nutrition · doi:10.3945/jn.115.225078 · Cited by 57
TerraceM: A MATLAB® tool to analyze marine and lacustrine terraces using high-resolution topography
Jara‐Muñoz, J., Melnick, D., & Strecker, M. R. (2015) · Geosphere · doi:10.1130/ges01208.1 · Cited by 54
Evaluating Upper-Body Strength and Power From a Single Test: The Ballistic Push-up
Wang, R., Hoffman, J. R., Sadres, E., Bartolomei, S., Muddle, T. W. D., Fukuda, D. H., & Stout, J. R. (2017) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001832 · Cited by 55
Can gray values be converted to Hounsfield units? A systematic review
Eguren, M., Holguin, A., Diaz, K. T., Vidalón, J. A., Liñán-Durán, C., Pachêco‐Pereira, C., & Lagravère, M. O. (2021) · Dentomaxillofacial Radiology · doi:10.1259/dmfr.20210140 · Cited by 59
Lázaro, A., Lázaro, M., Villarino, R., & Girbau, D. (2021) · IEEE Access · doi:10.1109/access.2021.3105390 · Cited by 54
Ohno, Y., Takenaka, D., Yoshikawa, T., Yui, M., Koyama, H., Yamamoto, K., Hamabuchi, N., Shigemura, C., Watanabe, A., Ueda, T., et al. (2021) · Radiology · doi:10.1148/radiol.211254 · Cited by 54
Acoustic Screening for Obstructive Sleep Apnea in Home Environments Based on Deep Neural Networks
Romero, H. E., Ma, N., Brown, G. J., & Hill, E. A. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3154719 · Cited by 65
Determinants and reference values for blood volume and total hemoglobin mass in women and men
Oberholzer, L., Montero, D., Robach, P., Siebenmann, C., Ryrsø, C. K., Bonne, T. C., Andersen, A. B., Bejder, J., Karlsen, T., Edvardsen, E., et al. (2023) · American Journal of Hematology · doi:10.1002/ajh.27162 · Cited by 61
Tekïn, M., Yurdal, M. O., Toraman, Ç., Korkmaz, G., & Uysal, İ. (2025) · BMC Medical Education · doi:10.1186/s12909-025-07241-4 · Cited by 65
Cadenas‐Sánchez, C., Alcántara-Moral, F., Sánchez‐Delgado, G., Mora-González, J., Martínez‐Téllez, B., Herrador‐Colmenero, M., Jiménez‐Pavón, D., Femia, P., Ruiz, J. R., & Ortega, F. B. (2014) · PubMed · doi:10.3305/nh.2014.30.6.7859 · Cited by 67
Gentamicin pharmacokinetics in old age and frailty
Hilmer, S. N., Tran, K., Rubie, P., Wright, J., Gnjidic, D., Mitchell, S. J., Matthews, S. T., & Carroll, P. R. (2011) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.2010.03825.x · Cited by 66
Deegan, T., Owen, R., Holt, T., Fielding, A. L., Biggs, J., Parfitt, M., Coates, A., & Roberts, L. (2014) · Journal of Medical Imaging and Radiation Oncology · doi:10.1111/1754-9485.12197 · Cited by 54
Effects of sex and age on regional prefrontal brain volume in two human cohorts
Cowell, P. E., Sluming, V. A., Wilkinson, I. D., Cezayirli, E., Romanowski, C. A. J., Webb, J. A., Keller, S. S., Mayes, A., & Roberts, N. (2007) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2006.05281.x · Cited by 54
Semiautomatic Volumetric Tumor Segmentation for Hepatocellular Carcinoma
Tacher, V., Lin, M., Chao, M., Gjesteby, L., Bhagat, N., Mahammedi, A., Ardon, R., Mory, B., & Geschwind, J.-F. H. (2013) · Academic Radiology · doi:10.1016/j.acra.2012.11.009 · Cited by 57
On the validity of blood flow measurement using colored microspheres
Hodeige, D., Pauw, M. D., Eechaute, W., Weyne, J., & Heyndrickx, G. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.276.4.h1150 · Cited by 54
Joyce, R., Kuziene, V., Zou, X., Wang, X., Pullen, F. S., & Loo, R. L. (2015) · Amino Acids · doi:10.1007/s00726-015-2076-0 · Cited by 56
Measurement of Focal Ground-glass Opacity Diameters on CT Images
Kakinuma, R., Ashizawa, K., Kuriyama, K., Fukushima, A., Ishikawa, H. T., Kamiya, H., Koizumi, N., Maruyama, Y., Minami, K., Nitta, N., et al. (2012) · Academic Radiology · doi:10.1016/j.acra.2011.12.002 · Cited by 54
T1 bias in chemical shift‐encoded liver fat‐fraction: Role of the flip angle
Kühn, J., Jahn, C., Hernando, D., Siegmund, W., Hadlich, S., Mayerle, J. V., Pfannmöller, J. P., Langner, S., & Reeder, S. B. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24457 · Cited by 54
Narrative skills following early confirmation of permanent childhood hearing impairment
Worsfold, S., Mahon, M., Yuen, H. M., & Kennedy, C. (2010) · Developmental Medicine & Child Neurology · doi:10.1111/j.1469-8749.2010.03641.x · Cited by 54
Guzzetta, N. A., Monitz, H. G., Fernandez, J. D., Fazlollah, T. M., Knežević, A., & Miller, B. E. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181e13470 · Cited by 54
Kliger, M., Stahl, S., Haddad, M., Suzan, E., Adler, R., & Eisenberg, E. (2014) · Pain Practice · doi:10.1111/papr.12216 · Cited by 66
Rossi, A., Zoico, E., Goodpaster, B. H., Sepe, A., Di Francesco, V., Fantin, F., Pizzini, F., Corzato, F., Vitali, A., Micciolo, R., et al. (2010) · Obesity · doi:10.1038/oby.2010.48 · Cited by 54
Rapid, high-resolution quantitative magnetization transfer MRI of the human spinal cord
Smith, A. K., Dortch, R. D., Dethrage, L. M., & Smith, S. A. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.03.005 · Cited by 54
A new rebound tonometer for home monitoring of intraocular pressure
Rosentreter, A., Jablonski, K. S., Mellein, A. C., Gaki, S., Hueber, A., & Dietlein, T. S. (2011) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-011-1785-7 · Cited by 54
South Asian men have different patterns of coronary artery disease when compared with European men
Tillin, T., Dhutia, H., Chambers, J. C., Malik, I. S., Coady, E., Mayet, J., Wright, A., Kooner, J. S., Shore, A. C., Thom, S., et al. (2007) · International Journal of Cardiology · doi:10.1016/j.ijcard.2007.07.129 · Cited by 54
van Swijndregt, A. D. M., The, S. H. K., Gussenhoven, E. J., Lancée, C. T., Rijsterborgh, H., de Groot, E., van der Steen, A. F. W., Bom, N., & Ackerstaff, R. G. A. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(96)00130-5 · Cited by 54
Comparison of Three Measures of the Ankle-Brachial Blood Pressure Index in a General Population
Cheng-Rui, P. A. N., Staessen, J. A., Li, Y., & Wang, J. (2007) · Hypertension Research · doi:10.1291/hypres.30.555 · Cited by 56
Emerging trends in minimally invasive haemodynamic monitoring and optimization of fluid therapy
Benington, S., Ferris, P., & Nirmalan, M. (2009) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e3283308e50 · Cited by 59
Technical note: Evaluation of a new system for measuring feeding behavior of dairy cows
Büchel, S., & Sundrum, A. (2014) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2014.06.010 · Cited by 62
Gómez-Simón, A., Navarro‐Núñez, L., Pérez‐Ceballos, E., Lozano, M. L., Candela, M., Cascales, A., Martı́nez, C., Corral, J., Vicente, V., & Rivera, J. (2007) · Transfusion and Apheresis Science · doi:10.1016/j.transci.2007.01.010 · Cited by 54
Krämer, N., Löfström, C., Vigre, H., Hoorfar, J., Bunge, C., & Malorny, B. (2010) · International Journal of Food Microbiology · doi:10.1016/j.ijfoodmicro.2010.08.026 · Cited by 54
Plontke, S. K., Bauer, M., & Meisner, C. (2007) · Otology & Neurotology · doi:10.1097/mao.0b013e31811515ae · Cited by 60
Moreira, S. R., Arsa, G., Oliveira, H. B., Lima, L., Campbell, C. S. G., & Simões, H. G. (2008) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e31816eb47c · Cited by 61
Pu, D., Zhou, Q., Zhang, M., Peng, Q., Zeng, S., & Xu, G. (2010) · Prenatal Diagnosis · doi:10.1002/pd.2611 · Cited by 54
Buijsen, J., van den Bogaard, J., Janssen, M. H. M., Bakers, F. C. H., Engelsman, S., Öllers, M., Beets‐Tan, R. G. H., Nap, M., Beets, G. L., Lambin, P., et al. (2011) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2010.11.018 · Cited by 54
Jonsdottir, I. H., Hägg, D. A., Glise, K., & Ekman, R. (2009) · PLoS ONE · doi:10.1371/journal.pone.0007659 · Cited by 54
Greutmann, M., Tobler, D., Biaggi, P., Mah, M. L., Crean, A. M., Oechslin, E. N., & Silversides, C. K. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.06.013 · Cited by 59
Francis, D. P., Coats, A. J. S., & Gibson, D. G. (1999) · International Journal of Cardiology · doi:10.1016/s0167-5273(99)00028-5 · Cited by 54
Estimating unmeasured anions in critically ill patients: Anion‐gap, base‐deficit, and strong‐ion‐gap
Story, D., Poustie, S., & Bellomo, R. (2002) · Anaesthesia · doi:10.1046/j.1365-2044.2002.02782_2.x · Cited by 54
Thomas, D. E., Yousef, Z. R., & Fraser, A. G. (2009) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfp086 · Cited by 54
Bourne, R., Rosser, D. A., Sukudom, P., Dineen, B., Laidlaw, D. A. H., Johnson, G. J., & Murdoch, I. (2003) · Eye · doi:10.1038/sj.eye.6700500 · Cited by 54
Aboyans, V., Lacroix, P., Lebourdon, A., Preux, P., Ferrières, J., & Laskar, M. (2003) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(02)00584-x · Cited by 61
Schallenberg, M., Bangre, V., Steuhl, K., Kremmer, S., & Selbach, J. M. (2010) · Journal of Refractive Surgery · doi:10.3928/1081597x-20100121-09 · Cited by 54
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.