STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 9,101–9,200 of 47,868
Genovesi, D., Giorgetti, A., Gimelli, A., Kusch, A., D’Aragona, I., Casagranda, M., Cannizzaro, G., Giubbini, R., Bertagna, F., Fagioli, G., et al. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-011-1855-4 · Cited by 63
Validation of Clinical Measurement of Kyphosis With a Simple Instrument, the Arcometer
DʼOsualdo, F., Schierano, S., & Iannis, M. (1997) · Spine · doi:10.1097/00007632-199702150-00011 · Cited by 54
Liu, X., Shen, M., Huang, S., Leng, L., Zhu, D., & Lü, F. (2014) · PLoS ONE · doi:10.1371/journal.pone.0087996 · Cited by 57
Rapid automatic assessment of microvascular density in sidestream dark field images
Bezemer, R., Dobbe, J. G. G., Bartels, S. A., Boerma, E. C., Elbers, P., Heger, M., & İnce, C. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0824-1 · Cited by 61
Bekes, K., John, M. T., Zyriax, R., Schaller, H., & Hirsch, C. (2011) · Clinical Oral Investigations · doi:10.1007/s00784-010-0496-5 · Cited by 54
Smilowitz, J. T., Gho, D. S., Mirmiran, M., German, J. B., & Underwood, M. A. (2014) · Journal of Human Lactation · doi:10.1177/0890334413517941 · Cited by 57
Jahnke, C., Nagel, E. C., Gebker, R., Bornstedt, A., Schnackenburg, B., Kozerke, S., Fleck, E., & Paetsch, I. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20877 · Cited by 57
Reckefuß, N., Butz, T., Horstkotte, D., & Faber, L. (2010) · International journal of cardiac imaging · doi:10.1007/s10554-010-9716-y · Cited by 63
Clinimetric Properties of the de Morton Mobility Index in Healthy, Community-Dwelling Older Adults
Davenport, S. J., & de Morton, N. A. (2010) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2010.08.023 · Cited by 54
Noetzli, M., Ansermot, N., Dobrinas, M., & Eap, C. B. (2012) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2012.02.008 · Cited by 54
Comparison of wrist-type and arm-type 24-h blood pressure monitoring devices for ambulatory use
Komori, T., Eguchi, K., Hoshide, S., Williams, B., & Kario, K. (2013) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e32835d124f · Cited by 54
Elmahgoub, S., de Velde, A. V., Peersman, W., Cambier, D. C., & Calders, P. (2011) · Disability and Rehabilitation · doi:10.3109/09638288.2011.623757 · Cited by 66
Pedersen, M. B., Danielsen, A. V., Hamilton-Dutoit, S. J., Bendix, K., Nørgaard, P. H., Møller, M. B., Steiniche, T., & d’Amore, F. (2014) · Histopathology · doi:10.1111/his.12407 · Cited by 56
Hobbs, N. Z., Henley, S. M. D., Wild, E. J., Leung, K. K., Frost, C. D., Barker, R. A., Scahill, R. I., Barnes, J., Tabrizi, S. J., & Fox, N. C. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.06.003 · Cited by 54
Zijlstra, A., & Zijlstra, W. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2013.04.021 · Cited by 54
Andreotti, M., Pirillo, M. F., Guidotti, G., Ceffa, S., Paturzo, G., Germano, P., Luhanga, R., Chimwaza, D., Mancini, M. G., Marazzi, M. C., et al. (2009) · Journal of Clinical Virology · doi:10.1016/j.jcv.2009.11.006 · Cited by 54
Validation of a proposed WOMAC short form for patients with hip osteoarthritis
Bilbao, A., Quintana, J. M., Escobar, A., Hayas, C. L., & Orive, M. (2011) · Health and Quality of Life Outcomes · doi:10.1186/1477-7525-9-75 · Cited by 63
Fingleton, C., Dempsey, L., Smart, K. M., & Doody, C. (2014) · Journal of Manipulative and Physiological Therapeutics · doi:10.1016/j.jmpt.2013.12.006 · Cited by 57
Mylonas, I., Kazmi, M., Fuller, L., deKemp, R. A., Yam, Y., Chen, L., Beanlands, R. S., & Chow, B. J. W. (2012) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jes079 · Cited by 55
Arterial Pulse Cardiac Output Agreement With Thermodilution in Patients in Hyperdynamic Conditions
Rocca, G. D., Costa, M. G., Chiarandini, P., Bertossi, G., Lugano, M., Pompei, L., Coccia, C., Sainz‐Barriga, M., & Pietropaoli, P. (2008) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2008.02.021 · Cited by 54
Pinto, E. C. B., Severo, M., Correia, S., dos‐Santos‐Silva, I., Lopes, C. M. M., & Barros, H. (2009) · Maternal and Child Nutrition · doi:10.1111/j.1740-8709.2009.00199.x · Cited by 77
Ultrasound Estimates for Midline Epidural Punctures in the Obese Parturient
Sahota, J. S., Carvalho, J. C. A., Balki, M., Fanning, N., & Arzola, C. (2013) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31827f55f0 · Cited by 54
Pisi, R., Aiello, M., Tzani, P., Marangio, E., Olivieri, D., & Chetta, A. A. (2010) · Journal of Asthma · doi:10.3109/02770903.2010.485667 · Cited by 55
Sniff nasal inspiratory pressure in children with muscular, chest wall or lung disease
Fauroux, B., Aubertin, G., Cohen, E., Clément, A., & Lofaso, F. (2008) · European Respiratory Journal · doi:10.1183/09031936.00050708 · Cited by 58
A Novel Approach to Partition Central and Peripheral Airway Nitric Oxide
Paredi, P., Kharitonov, S. A., Meah, S., Barnes, P. J., & Usmani, O. S. (2013) · CHEST Journal · doi:10.1378/chest.13-0843 · Cited by 55
Soliman, O. I. I., Knaapen, P., Geleijnse, M. L., Dijkmans, P. A., Anwar, A. M., Nemes, A., Michels, M., VLETTER, W., Lammertsma, A. A., & ten Cate, F. J. (2007) · Heart · doi:10.1136/hrt.2006.110460 · Cited by 54
Cook, S., Chambers, E., & Coleman, J. H. (2009) · Clinical Rehabilitation · doi:10.1177/0269215508098898 · Cited by 54
Validation and Comparison of EuroQol and Short Form 6D in Chronic Prostatitis Patients
Zhao, F.-L., Yue, M., Yang, H., Wang, T., Wu, J., & Li, S. (2010) · Value in Health · doi:10.1111/j.1524-4733.2010.00728.x · Cited by 56
Polar Activity Watch 200: a new device to accurately assess energy expenditure
Brugniaux, J. V., Niva, A., Pulkkinen, I., Laukkanen, R. M. T., Richalet, J.-P., & Pichon, A. P. (2010) · British Journal of Sports Medicine · doi:10.1136/bjsm.2007.045575 · Cited by 54
MacIntyre, U. E., Venter, C., Vorster, H., & Steyn, H. (2001) · Public Health Nutrition · doi:10.1079/phn200039 · Cited by 55
Cotinine as a biomarker of tobacco exposure: Development of a HPLC method and comparison of matrices
Petersen, G. O., Leite, C. E., Chatkin, J. M., & Thiesen, F. V. (2010) · Journal of Separation Science · doi:10.1002/jssc.200900575 · Cited by 54
Cook, A., Laughlin, D., Moore, M., North, D., Wilkins, K., Wong, G., Wallace-Scroggs, A., & Halvorsen, L. (2009) · American Journal of Critical Care · doi:10.4037/ajcc2009626 · Cited by 58
Automated CT Scan Scores of Bronchiectasis and Air Trapping in Cystic Fibrosis
DeBoer, E. M., Swiercz, W. B., Heltshe, S. L., Anthony, M. M., Szefler, P., Klein, R., Strain, J. D., Brody, A. S., & Sagel, S. D. (2013) · CHEST Journal · doi:10.1378/chest.13-0588 · Cited by 57
Santini, F., Kawel‐Boehm, N., Greiser, A., Bremerich, J., & Bieri, O. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25402 · Cited by 54
Peršić, S., Milardovic, S., Mehulic, K., & Čelebić, A. (2011) · PubMed · Cited by 68
Torabi, H., Khoddami, S. M., Ansari, N. N., & Dabirmoghaddam, P. (2015) · Journal of Voice · doi:10.1016/j.jvoice.2015.08.002 · Cited by 62
Thermodilution and Fick Cardiac Outputs Differ: Impact on Pulmonary Hypertension Evaluation
Fares, W. H., Blanchard, S., Stouffer, G. A., Chang, P. P., Rosamond, W. D., Ford, H. J., & Aris, R. M. (2012) · Canadian Respiratory Journal · doi:10.1155/2012/261793 · Cited by 55
How to assess the quality of your analytical method?
Topić, E., Nikolac, N., Panteghini, M., Theodorsson, E., Salvagno, G. L., Miler, M., Šimundić, A.-M., Infusino, I., Nordin, G., & Westgard, S. A. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0869 · Cited by 67
Securities Exchange Commission
Laguna, R. P. (2009) · Dialnet (Universidad de la Rioja) · Cited by 53
Alvarado-Serrano, C., Luna-Lozano, P. S., & Pallas-Areny, R. (2016) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.02.002 · Cited by 57
Rétory, Y., Niedzialkowski, P., de Picciotto, C., Bonay, M., & Petitjean, M. (2016) · PLoS ONE · doi:10.1371/journal.pone.0151983 · Cited by 66
Davies, J. M., Bailey, M. A., Griffin, K. J., & Scott, D. J. A. (2012) · Vascular · doi:10.1258/vasc.2011.ra0054 · Cited by 61
Vassbakk-Brovold, K., Kersten, C., Fegran, L., Mjåland, O., Mjåland, S., Seiler, S., & Berntsen, S. (2016) · BMC Sports Science Medicine and Rehabilitation · doi:10.1186/s13102-016-0035-z · Cited by 59
A new device to measure upper limb circumferences: validity and reliability.
Devoogdt, N., Lemkens, H., Geraerts, I., Nuland, I. V., Flour, M., Coremans, T., Christiaens, M.-R., & Kampen, M. V. D. (2010) · PubMed · Cited by 54
Carkeet, A., & Goh, Y. T. (2016) · Statistical Methods in Medical Research · doi:10.1177/0962280216665419 · Cited by 55
Diffusion-Weighted Imaging for Differentiating Uterine Leiomyosarcoma From Degenerated Leiomyoma
Li, H., Liu, J., Qiang, J., Zhang, H., Zhang, G., & Ma, F. (2016) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0000000000000565 · Cited by 54
Reinhardt, M., Piaggi, P., DeMers, B., Trinidad, C., & Krakoff, J. A. (2016) · Obesity · doi:10.1002/oby.21722 · Cited by 59
Validity and test–retest reliability of a novel simple back extensor muscle strength test
Harding, A. T., Weeks, B. K., Horan, S. A., Little, A., Watson, S. L., & Beck, B. R. (2017) · SAGE Open Medicine · doi:10.1177/2050312116688842 · Cited by 60
Koster, R. A., Veenhof, H., Botma, R., Hoekstra, A. T., Berger, S. P., Bakker, S. J. L., Alffenaar, J. C., & Touw, D. J. (2017) · Bioanalysis · doi:10.4155/bio-2016-0296 · Cited by 54
Validation of the VERT wearable jump monitor device in elite youth volleyball players
Borges, T. O., Moreira, A., Bacchi, R., Finotti, R. L., Ramos, M. C., Lopes, C. R., & Aoki, M. S. (2017) · Biology of Sport · doi:10.5114/biolsport.2017.66000 · Cited by 70
Jagoš, H., Pils, K., Haller, M., Wassermann, C., Chhatwal, C., Rafolt, D., & Rattay, F. (2017) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2017.1320434 · Cited by 62
Hallisey, E. J., Tai, E. W., Berens, A. S., Wilt, G. E., Peipins, L. A., Lewis, B. E., Graham, S., Flanagan, B. E., & Lunsford, N. B. (2017) · International Journal of Health Geographics · doi:10.1186/s12942-017-0102-z · Cited by 59
Mogensen, C. B., Wittenhoff, L., Fruerhøj, G., & Hansen, S. (2018) · BMC Pediatrics · doi:10.1186/s12887-018-0994-1 · Cited by 54
Transvaginal three‐dimensional ultrasound assessment of Sylvian fissures at 18–30 weeks' gestation
Poon, L. C., Sahota, D. S., Chaemsaithong, P., Nakamura, T. K., Machida, M., Naruse, K., Wah, Y. M. I., Leung, T. Y., & Pooh, R. K. (2018) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.20172 · Cited by 54
Smith, C., Chillrud, S. N., Jack, D. W., Kinney, P. L., Yang, Q., & Layton, A. M. (2019) · Journal of Occupational and Environmental Medicine · doi:10.1097/jom.0000000000001537 · Cited by 61
Bijl, R. C., Valensise, H. C. C., Novelli, G. P., Vasapollo, B., Wilkinson, I. B., Thilaganathan, B., Stöhr, E. J., Lees, C. C., van der Marel, C. D., Cornette, J. M. J., et al. (2019) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.20231 · Cited by 59
A standard operating procedure for King’s ALS clinical staging
Balendra, R., Khleifat, A. A., Fang, T., & Al‐Chalabi, A. (2019) · Amyotrophic Lateral Sclerosis and Frontotemporal Degeneration · doi:10.1080/21678421.2018.1556696 · Cited by 61
Braganza, M., Shaw, J., Solverson, K., Vis, D. C., Janovcik, J., Varughese, R. A., Thakrar, M. V., Hirani, N., Helmersen, D., & Weatherald, J. C. (2019) · CHEST Journal · doi:10.1016/j.chest.2019.01.035 · Cited by 54
Kim, J. E., Kim, H. O., Bae, K., Choi, D. S., & Nickel, D. M. (2019) · European Radiology · doi:10.1007/s00330-018-5947-4 · Cited by 61
Wochatz, M., Tilgner, N., Mueller, S., Rabe, S., Eichler, S., John, M., Völler, H., & Mayer, F. (2019) · Gait & Posture · doi:10.1016/j.gaitpost.2019.03.020 · Cited by 64
Wu, J., Xin, J., Yang, X., Sun, J., Xu, D., Zheng, N., & Yuan, C. (2019) · Medical Physics · doi:10.1002/mp.13739 · Cited by 59
The Learning Curve for Shared Decision-making in Symptomatic Aortic Stenosis
Coylewright, M. J., O’Neill, E. S., Sherman, A. E., Gerling, M. J., Adam, K., Xu, K., Grande, S. W., Dauerman, H. L., Dodge, S. E., Sobti, N. K., et al. (2020) · JAMA Cardiology · doi:10.1001/jamacardio.2019.5719 · Cited by 57
Ryan, E. H., Joseph, D. P., Ryan, C. M., Forbes, N. J. K., Yonekawa, Y., Mittra, R. A., Parke, D. W., Ringeisen, A., Emerson, G. G., Shah, G. K., et al. (2020) · Ophthalmology Retina · doi:10.1016/j.oret.2020.02.014 · Cited by 59
Parkinson, B., Gogna, R., Robb, C., Thompson, P., & Spalding, T. (2015) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-015-3683-8 · Cited by 56
Rohling, R. G., & Bíró, P. (1999) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009950425204 · Cited by 54
Izatt, M. T., Bateman, G. R., & Adam, C. J. (2012) · Scoliosis · doi:10.1186/1748-7161-7-14 · Cited by 54
Accuracy and reproducibility of the TonoVet®rebound tonometer in birds of prey
Reuter, A. R., Müller, K., Arndt, G., & Eule, J. C. (2010) · Veterinary Ophthalmology · doi:10.1111/j.1463-5224.2010.00817.x · Cited by 54
Validity and reproducibility of the Jamar dynamometer in children aged 4 – 11 years
van den Beld, W. A., van der Sanden, G. A. C., Sengers, R. C. A., Verbeek, A. L. M., & Gabreëls, F. J. M. (2006) · Disability and Rehabilitation · doi:10.1080/09638280600631047 · Cited by 74
Accuracy of duplex sonography before carotid endarterectomy — A comparison with angiography
Hansen, F., Bergqvist, D., Lindblad, B., Lindh, M., Mätzsch, T., & Länne, T. (1996) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/s1078-5884(96)80252-8 · Cited by 54
Chakravarthy, M., Patil, T., Jayaprakash, K., Kalligudd, P., Prabhakumar, D., & Jawali, V. (2007) · Annals of Cardiac Anaesthesia · doi:10.4103/0971-9784.37937 · Cited by 54
Bolte, A. C., Dekker, G., van Eyck, J., van Schijndel, R. J. M. S., & van Geijn, H. P. (2000) · Hypertension in Pregnancy · doi:10.1081/prg-100101987 · Cited by 54
Respiratory mechanics and arterial blood gases during and after laparoscopic cholecystectomy
Iwasaka, H., Miyakawa, H., Yamamoto, H., Kitano, T., Taniguchi, K., & Honda, N. (1996) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03011253 · Cited by 54
The accuracy and precision of four infrared aural canal thermometers during cardiac surgery
Imamura, M., Matsukawa, T., Ozaki, M., Sessler, D. I., NISHIYAMA, T., & Kumazawa, T. (1998) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1998.tb05281.x · Cited by 54
Measurement and interpretation of QT dispersion
Batchvarov, V. N., & Malík, M. (2000) · Progress in Cardiovascular Diseases · doi:10.1053/pcad.2000.0420325 · Cited by 54
Reeves, M. M., Capra, S. M., Bauer, J. D., Davies, P., & Battistutta, D. (2005) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602114 · Cited by 58
Peripheral Refraction in Normal Infant Rhesus Monkeys
Hung, L., Ramamirtham, R., Huang, J., Qiao-Grider, Y., & Smith, E. L., III (2008) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.07-1493 · Cited by 54
Matecki, S., Topin, N., Hayot, M., Rivier, F., Échenne, B., PREFAUT, C. G., & Ramonatxo, M. (2001) · Neuromuscular Disorders · doi:10.1016/s0960-8966(00)00179-6 · Cited by 56
Post, M. W. M., Lieshout, G. V., Seelen, H. A. M., Snoek, G. J., IJzerman, M. J., & Pons, C. (2006) · Spinal Cord · doi:10.1038/sj.sc.3101937 · Cited by 54
RELIABILITY OF KNEE AND ANKLE STRENGTH MEASURES IN AN OLDER ADULT POPULATION
Ordway, N. R., Hand, N., Briggs, G., & Ploutz‐Snyder, L. L. (2006) · The Journal of Strength and Conditioning Research · doi:10.1519/00124278-200602000-00013 · Cited by 54
Cepeda, M. S., Africano, J. M., Polo, R., Alcalá, R., & Carr, D. B. (2003) · Pain · doi:10.1016/j.pain.2003.09.006 · Cited by 54
Precision of recumbent anthropometry
Williamson, D. F., Kahn, H. S., Worthman, C. M., Burnette, J. C., & Russell, C. M. (1993) · American Journal of Human Biology · doi:10.1002/ajhb.1310050205 · Cited by 58
Rule, A. D. (2007) · Current Opinion in Nephrology & Hypertension · doi:10.1097/mnh.0b013e328057de8b · Cited by 60
Martínez-de-la-Casa, J. M., Jiménez-Santos, M., Saenz-Frances, F., Matilla-Rodero, M., Mendez-Hernandez, C. D., Herrero‐Vanrell, R., & Garcia-Sanchez, J. (2009) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.2009.01774.x · Cited by 54
Aliwalas, L. L., Noble, L., Nesbitt, K., Fallah, S., Shah, V. S., & Shah, P. S. (2004) · Journal of Perinatology · doi:10.1038/sj.jp.7211202 · Cited by 54
Improvement in cardiac sympathetic nerve activity in responders to resynchronization therapy
Burri, H., Sunthorn, H., Somsen, A., Fleury, E., Stettler, C., Shah, D. C., & Righetti, A. (2008) · EP Europace · doi:10.1093/europace/eun017 · Cited by 54
Accuracy of base excess—An in vitro evaluation of the Van Slyke equation
Morgan, T. J., Clark, C., & Endre, Z. H. (2000) · Critical Care Medicine · doi:10.1097/00003246-200008000-00041 · Cited by 54
Use of accelerometers for detecting foot-ground contact time during running
Purcell, B., Channells, J., James, D. A., & Barrett, R. (2005) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.638389 · Cited by 69
van Hoek, I., Vandermeulen, E., Duchateau, L., Lefebvre, H., Croubels, S., Peremans, K., Polis, I., & Daminet, S. (2007) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.2007.tb03048.x · Cited by 54
Comparison of intrathoracic and intra-abdominal measurements of central venous pressure
Joynt, G. M., Gomersall, C. D., Buckley, T., Oh, T. E., Young, R. J., & Freebairn, R. (1996) · The Lancet · doi:10.1016/s0140-6736(96)90611-x · Cited by 54
Barthez, P. Y., Hornof, W. J., Cowgill, L. D., Neal, L. A., & Mickel, P. (1998) · Veterinary Radiology & Ultrasound · doi:10.1111/j.1740-8261.1998.tb01636.x · Cited by 56
Cross-sectional Sample of Peripheral Refraction in Four Meridians in Myopes and Emmetropes
Ehsaei, A., Mallen, E. A. H., Chisholm, C. M., & Pacey, I. E. (2011) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.11-7635 · Cited by 64
Papaioannou, T., Stamatelopoulos, K. S., GIALAFOS, E. J., Vlachopoulos, C. V., Karatzis, E. N., Nanas, J. N., & Lekakis, J. P. (2004) · Journal of Clinical Monitoring and Computing · doi:10.1023/b:jocm.0000032809.71793.b8 · Cited by 65
The Utility of Early End-Tidal Capnography in Monitoring Ventilation Status After Severe Injury
Warner, K. J., Cuschieri, J., Garland, B. T., Carlbom, D., Baker, D., Copass, M. K., Jurkovich, G. J., & Bulger, E. M. (2009) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e3181957a25 · Cited by 61
Kim, J., Rietdyk, S., & Breur, G. J. (2008) · American Journal of Veterinary Research · doi:10.2460/ajvr.69.9.1116 · Cited by 67
Hol, A. T., Eng, J. J., Miller, W. C., Sproule, S., & Krassioukov, A. V. (2007) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2006.12.044 · Cited by 62
Delfino, J. G., Bhasin, M., Cole, R., Eisner, R. L., Merlino, J., León, A. R., & Oshinski, J. N. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20641 · Cited by 56
IJzerman, M. J., Baardman, G., Hof, M. A. V. '., Boom, H. B. K., Hermens, H. J., & Veltink, P. H. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90054-0 · Cited by 58
Rodríguez-Capote, K., Kim, K., Paes, B. A., Turner, D., & Grey, V. (2008) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2008.09.108 · Cited by 54
Rovas, L., Sladkevicius, P., Strobel, E., & Valentin, L. (2005) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.1884 · Cited by 54
Coupé, V. M. H., Veenhof, C., van Tulder, M. W., Dekker, J., Bijlsma, J. W. J., & van den Ende, C. H. M. (2006) · Annals of the Rheumatic Diseases · doi:10.1136/ard.2006.054478 · Cited by 60
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.