STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 9,201–9,300 of 47,868
Borsa, P. A., Jacobson, J. A., Scibek, J. S., & Dover, G. C. (2005) · The American Journal of Sports Medicine · doi:10.1177/0363546504269940 · Cited by 54
Global myocardial blood flow and global flow reserve measurements by MRI and PET are comparable
Koskenvuo, J. W., Sakuma, H., Niemi, P., Toikka, J., Knuuti, J. M., Laine, H., Komu, M. E. S., Kormano, M., Saraste, M., & Hartiala, J. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1051 · Cited by 54
Impedance cardiography revisited
Cotter, G., Schachner, A., Sasson, L., Dekel, H., & Moshkovitz, Y. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/9/005 · Cited by 54
Orme, R., Pigott, D. W., & Mihm, F. G. (2004) · Anaesthesia · doi:10.1111/j.1365-2044.2004.03710.x · Cited by 54
Badia, Farré, R., Montserrat, J. M., Ballester, E., Hernandez, L., Rotger, M., Rodriguez‐Roisin, R., & Navajas, D. (1998) · European Respiratory Journal · doi:10.1183/09031936.98.11051128 · Cited by 55
White, S. A., & van den Broek, N. R. (2004) · Statistics in Medicine · doi:10.1002/sim.1804 · Cited by 59
Cannesson, M. P., Jacques, D., Pinsky, M. R., & Gorcsan, J. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01090.2005 · Cited by 54
Practical assessment of rotator cuff muscle volumes using shoulder MRI
Lehtinen, J., Tingart, M., Apreleva, M., Zurakowski, D., Palmer, W. E., & Warner, J. J. P. (2003) · Acta Orthopaedica Scandinavica · doi:10.1080/00016470310018270 · Cited by 54
Riedler, J., Gamper, A., Eder, W., & Oberfeld, G. (1998) · European Respiratory Journal · doi:10.1183/09031936.98.11020355 · Cited by 54
Katritsis, D. G., Ellenbogen, K. A., & Becker, A. E. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.05.029 · Cited by 54
Perel, R., Slaughter, R., & Strugnell, W. (2006) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640600737664 · Cited by 54
Variation in non-invasive measurements of vascular function in healthy volunteers during daytime
ter Avest, E., Holewijn, S., Stalenhoef, A. F. H., & Graaf, J. D. (2005) · Clinical Science · doi:10.1042/cs20040300 · Cited by 64
Accuracy of Real‐time Three‐dimensional Echocardiography for Quantifying Right Ventricular Volume
Schindera, S. T., Mehwald, P., Sahn, D. J., & Kececioglu, D. (2002) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2002.21.10.1069 · Cited by 54
Comparison of methods to quantitate 18F-FDG uptake with PET during experimental acute lung injury.
Chen, D. L., Mintun, M. A., & Schuster, D. P. (2004) · PubMed · Cited by 61
Estimation of end-expiratory lung volume variations by optoelectronic plethysmography
Dellacà, R. L., Aliverti, A., Pelosi, P., Carlesso, E., Chiumello, D., Pedotti, A., & Gattinoni, L. (2001) · Critical Care Medicine · doi:10.1097/00003246-200109000-00026 · Cited by 55
Flow cytometry counting of CD34+ cells in whole blood
Fornas, Ò., García‐López, J., & Pétriz, J. (2000) · Nature Medicine · doi:10.1038/77571 · Cited by 54
Influence of arrhythmias on gated SPECT myocardial perfusion and function quantification.
Nichols, K. J., Dorbala, S., DePuey, E. G., Yao, S., Sharma, A., & Rozanski, A. (1999) · PubMed · Cited by 54
Schwammenthal, E., Chen, C., Giesler, M., Sagie, A., Guerrero, J., de Prada, J. A. V., Hombach, V., Weyman, A. E., & Levine, R. A. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00428-9 · Cited by 54
Clinical significance of airway responsiveness in children of low birthweight
Chan, K. N., Elliman, A., Bryan, E. M., & Silverman, M. (1989) · Pediatric Pulmonology · doi:10.1002/ppul.1950070411 · Cited by 54
Tang, H., Vasselli, J. R., Wu, E. X., Boozer, C. N., & Gallagher, D. (2002) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.0527.2001 · Cited by 56
Lukaski, H. C., Marchello, M. J., Hall, C. B., Schafer, D. M., & Siders, W. A. (1999) · Nutrition · doi:10.1016/s0899-9007(99)00154-9 · Cited by 63
Determinants of variability of protein content, volume and pH of exhaled breath condensate
Bloemen, K., Lissens, G., Desager, K., & Schoeters, G. E. R. (2006) · Respiratory Medicine · doi:10.1016/j.rmed.2006.10.008 · Cited by 54
Haude, M., Caspari, G., Baumgart, D., Brennecke, R., Meyer, J. ̈., & Erbel, R. M. (1996) · Circulation · doi:10.1161/01.cir.94.3.286 · Cited by 54
Pickett, B. R., & Buell, J. C. (1992) · The American Journal of Cardiology · doi:10.1016/0002-9149(92)91235-v · Cited by 56
LIU, W. H. D., & Aitkenhead, A. R. (1991) · British Journal of Anaesthesia · doi:10.1093/bja/67.6.768 · Cited by 54
Oscillometric Blood Pressure Measurements by Different Devices Are Not Interchangeable
Kaufmann, M., Pargger, H., & Drop, L. J. (1996) · Anesthesia & Analgesia · doi:10.1097/00000539-199602000-00029 · Cited by 54
Evaluation of the FACScount, TRAx CD4 and Dynabeads methods for CD4 lymphocyte determination
Lyamuya, E., Kagoma, C., Mbena, E., Urassa, W. K., Pallangyo, K., Mhalu, F. S., & Biberfeld, G. (1996) · Journal of Immunological Methods · doi:10.1016/0022-1759(96)00094-4 · Cited by 54
PEAT, J. K., Salome, C. M., Bauman, A. E., Toelle, B. G., Wachinger, S. L., & Woolcock, A. J. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/144.2.338 · Cited by 54
Continuous thermodilution cardiac output measurement in sheep
Yelderman, M., Quinn, M. D., McKown, R. C., Eberhart, R. C., & Dollar, M. L. (1992) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)34783-x · Cited by 54
Cogill, J. L., Taylor, P. J., Westley, I. S., Morris, R. G., Lynch, S. V., & Johnson, A. G. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.9.1942 · Cited by 54
Reporting Statistical Information in Medical Journal Articles
Cummings, P., & Rivara, F. P. (2003) · Archives of Pediatrics and Adolescent Medicine · doi:10.1001/archpedi.157.4.321 · Cited by 57
Wickramasinghe, V. P., Lamabadusuriya, S. P., Cleghorn, G. J., & Davies, P. S. W. (2008) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602835 · Cited by 53
Wrist-worn accelerometers in assessment of energy expenditure during intensive training
Kinnunen, H., Tanskanen, M., Kyröläinen, H., & Westerterp, K. R. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/11/1841 · Cited by 53
Evans, D. S., Snitker, S., Wu, S.-H., Mody, A., Njajou, O. T., Perlis, M. L., Gehrman, P. R., Shuldiner, A. R., & Hsueh, W.-C. (2011) · SLEEP · doi:10.1093/sleep/34.5.661 · Cited by 53
Edwards-Jackson, N., Kerr, S., Tieu, H., Ananworanich, J., Hammer, S., Ruxrungtham, K., Phanuphak, P., Avihingsanon, A., & for the HIV-NAT 006 Study Team (2011) · HIV Medicine · doi:10.1111/j.1468-1293.2011.00916.x · Cited by 53
Waldmeier, S., Grunt, S., Delgado‐Eckert, E., Latzin, P., Steinlin, M. I., Fuhrer, K., & Frey, U. (2013) · Experimental Brain Research · doi:10.1007/s00221-013-3504-6 · Cited by 55
Mars, G. M. J., Kempen, G. I. J. M., Post, M. W. M., Proot, I. M., Mesters, I., & van Eijk, J. T. M. (2009) · Quality of Life Research · doi:10.1007/s11136-009-9537-4 · Cited by 53
Rago, V., Brito, J., Figueiredo, P., Ermidis, G., Barreira, D., & Rebelo, A. (2020) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000002987 · Cited by 38
Optimising Sample Preparation and Calibrations in EDXRF for Quantitative Soil Analysis
Croffie, M. E. T., Williams, P. N., Fenton, O. S., Fenelon, A., Metzger, K., & Daly, K. (2020) · Agronomy · doi:10.3390/agronomy10091309 · Cited by 63
When can the Bland & Altman limits of agreement method be used and when it should not be used
Taffé, P. (2021) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2021.04.004 · Cited by 60
Winkel, D. J., Suryanarayana, V. R., Ali, A. M., Görich, J., Buß, S. J., Mendoza, A., Schwemmer, C., Sharma, P., Schoepf, U. J., & Rapaka, S. (2022) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeab119 · Cited by 51
Nemes, R., Lengyel, S., Nagy, G., Hampton, D. R., Gray, M., Renew, J. R., TASSONYI, E., Fülesdi, B., & Brull, S. J. (2021) · Anesthesiology · doi:10.1097/aln.0000000000003896 · Cited by 53
Mazefsky, C. A., Conner, C. M., Breitenfeldt, K. E., Leezenbaum, N. B., Chen, Q., Bylsma, L. M., & Pilkonis, P. A. (2021) · Journal of Clinical Child & Adolescent Psychology · doi:10.1080/15374416.2021.1955372 · Cited by 61
Velasco, C., da Cruz, G. J. L., Lavín, B., Hua, A. X., Fotaki, A., Botnar, R. M., & Prieto, C. (2021) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29091 · Cited by 53
Shi, D., Hang, J., Neufeld, J., Zhao, S., & House, J. D. (2022) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2022.104601 · Cited by 59
Improved cattle behaviour monitoring by combining Ultra-Wideband location and accelerometer data
Benaissa, S., Tuyttens, F., Plets, D., MARTENS, L. C., Vandaele, L., Joseph, W., & Sonck, B. (2023) · animal · doi:10.1016/j.animal.2023.100730 · Cited by 62
Challenges and best practices in omics benchmarking
Brooks, T. G., Lahens, N. F., Mrčela, A., & Grant, G. R. (2024) · Nature Reviews Genetics · doi:10.1038/s41576-023-00679-6 · Cited by 77
Comparison between Clinical and Digital Soft Tissue Measurements
Schneider, D., Ender, A., Truninger, T. C., Leutert, C., Sahrmann, P., Roos, M., & Schmidlin, P. R. (2013) · Journal of Esthetic and Restorative Dentistry · doi:10.1111/jerd.12084 · Cited by 53
Fruehauf, H., Menne, D., Kwiatek, M. A., Forras‐Kaufman, Z., Kaufman, E., Goetze, O., Fried, M., Schwizer, W., & Fox, M. (2011) · Neurogastroenterology & Motility · doi:10.1111/j.1365-2982.2011.01743.x · Cited by 54
Plesch, W., & van den Besselaar, A. M. H. P. (2007) · International Journal of Laboratory Hematology · doi:10.1111/j.1751-553x.2007.00998.x · Cited by 53
Krishnaswamy, A., Parashar, A., Agarwal, S., Modi, D. K., Poddar, K. L., Svensson, L. G., Roselli, E. E., Schoenhagen, P., Tuzcu, E. M., & Kapadia, S. R. (2014) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.25488 · Cited by 54
Minnesota Leisure Time Activity Questionnaire and Doubly Labeled Water in Adolescents
Slinde, F., Arvidsson, D., Sjöberg, A., & N, L. R.-H. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000093608.95629.85 · Cited by 63
Khankirawatana, B., Khankirawatana, S., Lof, J., & Porter, T. R. (2002) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2002.122080 · Cited by 53
Transcutaneous bilirubinometry with the Bilicheck® in very premature newborns
Willems, W. A., Berg, L., de Wit, H., & Molendijk, A. (2004) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767050400013818 · Cited by 53
Azzi, S., Steunou, V., Rousseau, A., Rossignol, S., Thibaud, N., Danton, F., Jule, M. L., Gicquel, C., Bouc, Y. L., & Netchine, I. (2011) · Human Mutation · doi:10.1002/humu.21403 · Cited by 64
Kardos, A., Rudas, L., Simon, J., Gingl, Z., & Csanády, M. (1997) · Clinical Autonomic Research · doi:10.1007/bf02308842 · Cited by 54
Kirby, M., Svenningsen, S., Ahmed, H., Wheatley, A., Etemad‐Rezai, R., Paterson, N. A. M., & Párraga, G. (2011) · Academic Radiology · doi:10.1016/j.acra.2011.03.005 · Cited by 53
Last menstrual period provides the best estimate of gestation length for women in rural Guatemala
Neufeld, L. M., Haas, J. D., Grajeda, R., & Martorell, R. (2006) · Paediatric and Perinatal Epidemiology · doi:10.1111/j.1365-3016.2006.00741.x · Cited by 53
Evaluation of the Mercy TAPE: Performance Against the Standard for Pediatric Weight Estimation
Abdel‐Rahman, S. M., Paul, I. M., James, L. P., & Lewandowski, A. (2013) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2013.02.021 · Cited by 56
Z-Score Comparability of Bone Mineral Density Reference Databases for Children
Kocks, J. W. H., Ward, K. A., Zulf Mughal, M., Moncayo, R., Adams, J. E., & Högler, W. (2010) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-0677 · Cited by 56
New Specific Equation to Estimate Resting Energy Expenditure in Severely Obese Patients
Horie, L. M., González, M. C., Torrinhas, R. S., Cecconello, I., & Waitzberg, D. L. (2011) · Obesity · doi:10.1038/oby.2010.326 · Cited by 64
Silva, D., Ponte, C., Hacker, M. A., & Antas, P. R. Z. (2013) · Acta Tropica · doi:10.1016/j.actatropica.2013.04.002 · Cited by 53
Singh, A., Juneja, R., Mehta, Y. B., & Trehan, N. K. (2002) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/jcan.2002.31063 · Cited by 53
Koley, B. L., & Dey, D. (2013) · Measurement · doi:10.1016/j.measurement.2013.03.016 · Cited by 57
Gagneux‐Brunon, A., Delanaye, P., Maillard, N., Fresard, A., Basset, T., Alamartine, É., Lucht, F., Pottel, H., & Mariat, C. (2013) · AIDS · doi:10.1097/qad.0b013e32835fac30 · Cited by 58
Measuring the Glomerular Filtration Rate in Obese Individuals without Overt Kidney Disease
Friedman, A. N., Strother, R. M., Quinney, S. K., Hall, S. D., Perkins, S. M., Brizendine, E. J., Inman, M. M., Gómez, G. A., Shihabi, Z. K., Moe, S. M., et al. (2010) · Nephron Clinical Practice · doi:10.1159/000317203 · Cited by 61
Ditor, D. S., Kamath, M. V., MacDonald, M. J., Bugaresti, J., McCartney, N., & Hicks, A. L. (2005) · Clinical Autonomic Research · doi:10.1007/s10286-005-0293-4 · Cited by 67
Robotic treadmill training improves cardiovascular function in spinal cord injury patients
Turiel, M., Sitia, S., Cicala, S., Magagnin, V., Bo, I., Porta, A., Caiani, E. G., Ricci, C., Licari, V., Colonna, V. D. G., et al. (2010) · International Journal of Cardiology · doi:10.1016/j.ijcard.2010.02.010 · Cited by 57
Sleep-Wake Evaluation from Whole-Night Non-Contact Audio Recordings of Breathing Sounds
Dafna, E., Tarasiuk, A., & Zigel, Y. (2015) · PLoS ONE · doi:10.1371/journal.pone.0117382 · Cited by 60
Dick, R., Penzel, T., Fietze, I., Partinen, M., Hein, H., & Schulz, J. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/12/005 · Cited by 53
Salouti, R., Nowroozzadeh, M. H., Zamani, M., Ghoreyshi, M., & Salouti, R. (2010) · Optometry · doi:10.1016/j.optm.2010.07.025 · Cited by 53
da Silva, D. R. P., Ribeiro, A. S., Pavão, F. H., Ronque, Ê. R. V., Avelar, A., Silva, A. M., & Cyrino, E. S. (2013) · Revista da Associação Médica Brasileira · doi:10.1016/j.ramb.2013.03.006 · Cited by 64
Validity of the two-parameter model in estimating the anaerobic work capacity
Dekerle, J., Brickley, G., Hammond, A. J. P., PRINGLE, J. S. M., & Carter, H. (2005) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0074-8 · Cited by 53
Carroll, R. J., Delaigle, A., & Hall, P. (2011) · Journal of the American Statistical Association · doi:10.1198/jasa.2011.tm10355 · Cited by 53
A new rapid home test for faecal calprotectin in ulcerative colitis
Elkjær, M., Burisch, J. M., Hansen, V. V., Kristensen, B. D., JENSEN, J. ‐. S., & Munkholm, P. (2009) · Alimentary Pharmacology & Therapeutics · doi:10.1111/j.1365-2036.2009.04164.x · Cited by 56
Maniar, R. L., Hochman, D. J., Wirtzfeld, D. A., McKay, A. M., Yaffe, C. S., Yip, B., SILVERMAN, R. E., & Park, J. (2014) · Annals of Surgical Oncology · doi:10.1245/s10434-014-3741-3 · Cited by 53
Chung, M., Wang, D., Rizzo, A. M., Gachette, D., Delnord, M., Parambi, R. J., Kang, C., & Brugge, D. (2015) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph120302765 · Cited by 53
Use of automated home blood pressure monitoring in pregnancy: Is it safe?
Lo, C., Taylor, R. S., Gamble, G. D., McCowan, L. M. E., & North, R. A. (2002) · American Journal of Obstetrics and Gynecology · doi:10.1067/mob.2002.126847 · Cited by 53
Aasen, G., Fagertun, H., & Halse, J. (2006) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365510600898214 · Cited by 61
Li, X., Shiota, T., Delabays, A., Teien, D. E., Zhou, X., Sinclair, B. G., Pandian, N. G., & Sahn, D. J. (1999) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(99)70099-4 · Cited by 53
In vivo analysis of physiological 3D blood flow of cerebral veins
Schuchardt, F. F., Schroeder, L., Anastasopoulos, C., Markl, M., Bäuerle, J., Hennemuth, A., Drexl, J., Valdueza, J. M., Mader, I., & Harloff, A. (2015) · European Radiology · doi:10.1007/s00330-014-3587-x · Cited by 53
Quantitative Measures of Modic Changes in Lumbar Spine Magnetic Resonance Imaging
Wang, Y., Videman, T., Niemeläinen, R., & Battié, M. C. (2011) · Spine · doi:10.1097/brs.0b013e3181ecf283 · Cited by 53
Vasseljen, O., Fladmark, A. M., Westad, C., & Torp, H. G. (2007) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2007.07.013 · Cited by 61
Adell, E., Wehmhörner, S., & Rydwik, E. (2012) · Journal of Geriatric Physical Therapy · doi:10.1519/jpt.0b013e318264b8ed · Cited by 66
Benhamou, M., Baron, G., Dalichampt, M., Boutron, I., Alami, S., Rannou, F., Ravaud, P., & Poiraudeau, S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0053886 · Cited by 59
New method to measure and improve consistency of baroreflex sensitivity values
Bernardi, L., Barbieri, G. D., Rosengård‐Bärlund, M., Mäkinen, V., Porta, C. D., & Groop, P. (2010) · Clinical Autonomic Research · doi:10.1007/s10286-010-0079-1 · Cited by 61
Region-Based Endocardium Tracking on Real-Time Three-Dimensional Ultrasound
Duan, Q., Angelini, E. D., Herz, S. L., Ingrassia, C. M., Costa, K. D., Holmes, J. W., Homma, S., & Laine, A. F. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.08.012 · Cited by 57
Validation of Pattern-Recognition Monitors in Children Using Doubly Labeled Water
CALABRÓ, M. A., STEWART, J. M., & WELK, G. J. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31828579c3 · Cited by 53
Reproducibility of high-resolution MRI for the middle cerebral artery plaque at 3T
Yang, W., Huang, B., Liu, X., Liu, H., Li, P., & Zhu, W. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2013.10.003 · Cited by 53
Rupp, F., Axmann, D., Ziegler, C., & Geis‐Gerstorfer, J. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10198 · Cited by 53
Maigne, J.-Y., Lapeyre, E., Morvan, G., & Chatellier, G. (2003) · Spine · doi:10.1097/01.brs.0000065569.76853.e9 · Cited by 53
Transcranial Magnetic Cortical Stimulation Relieves Central Pain
Canavero, S., Bonicalzi, V., Dotta, M., Vighetti, S., Asteggiano, G., & Cocito, D. (2002) · Stereotactic and Functional Neurosurgery · doi:10.1159/000068965 · Cited by 59
Gregory, C. O., Yu, C., & Singh, R. H. (2007) · Genetics in Medicine · doi:10.1097/gim.0b013e318159a355 · Cited by 53
Assessing and minimizing the effects of noise and motion in clinical DTI at 3 T
Tijssen, R. H. N., Jansen, J. F. A., & Backes, W. H. (2009) · Human Brain Mapping · doi:10.1002/hbm.20695 · Cited by 54
Ley, S., Eichhorn, J., Ley‐Zaporozhan, J., Ulmer, H. E., Schenk, J., Kauczor, H., & Arnold, R. (2007) · Pediatric Radiology · doi:10.1007/s00247-007-0414-4 · Cited by 53
Computed Tomography Perfusion Using First Pass Methods for Lung Nodule Characterization
Sitartchouk, I., Roberts, H. C., Pereira, A. M. B., Bayanati, H., Waddell, T. K., & Roberts, T. P. L. (2008) · Investigative Radiology · doi:10.1097/rli.0b013e3181690148 · Cited by 53
Sardanelli, F., Quarenghi, M., Leo, G. D., Boccaccini, L., & Schiavi, A. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21292 · Cited by 53
Cleary, J., Daniells, S., Okely, A. D., Batterham, M. J., & Nicholls, J. (2007) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2007.10.004 · Cited by 61
Ultrasonic Characterization of the Pulmonary Venous Wall
Cabrera, J. Á., Sánchez‐Quintana, D., Farré, J., Navarro, F., Campal, J. M. R., Cabestrero, F., Anderson, R. H., & Ho, S. Y. (2002) · Circulation · doi:10.1161/01.cir.0000026397.78200.c4 · Cited by 53
Wong, W. W., Roberts, S. B., Racette, S. B., Das, S. K., Redman, L. M., Rochon, J., Bhapkar, M. V., Clarke, L. L., & Kraus, W. E. (2014) · Journal of Nutrition · doi:10.3945/jn.113.187823 · Cited by 62
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.