STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 8,701–8,800 of 47,868
Reliability and validity of the 6-min walk test in adults and seniors with intellectual disabilities
Guerra-Balic, M., Oviedo, G. R., Javierre, C. F., Fortuño, J., Barnet-López, S., Méndez, O. A. N., Álamo, J., & Fernhall, B. (2015) · Research in Developmental Disabilities · doi:10.1016/j.ridd.2015.09.011 · Cited by 74
An assessment of the accuracy and consistency of human perception of weed cover
Andújar, D., Ribeiro, Á., Carmona, R., Fernández‐Quintanilla, C., & Dorado, J. (2010) · Weed Research · doi:10.1111/j.1365-3180.2010.00809.x · Cited by 56
Heritability of mandibular cephalometric variables in twins with completed craniofacial growth
Šidlauskas, M., Šalomskienė, L., Andriuškevičiūtė, I., Šidlauskienė, M., Labanauskas, Ž., Vasiliauskas, A., Kupčinskas, L., Juzėnas, S., & Šidlauskas, A. (2015) · European Journal of Orthodontics · doi:10.1093/ejo/cjv062 · Cited by 64
High-Resolution Ultrasound Imaging
Laschke, M. W., Körbel, C., Rudzitis‐Auth, J., Gashaw, I., Reinhardt, M., Hauff, P., Zollner, T. M., & Menger, M. D. (2009) · American Journal Of Pathology · doi:10.2353/ajpath.2010.090617 · Cited by 61
Rodrigues, J. N., Zhang, W., Scammell, B. E., Russell, P. G., Chakrabarti, I., Fullilove, S., Davidson, D., & Davis, T. R. C. (2015) · Journal of Hand Surgery (European Volume) · doi:10.1177/1753193415601350 · Cited by 65
OCT for optic disc evaluation in idiopathic intracranial hypertension
Skau, M., Miléa, D., Sander, B., Wegener, M., & Jensen, R. (2010) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-010-1527-2 · Cited by 56
Influence of Visual Field Testing Frequency on Detection of Glaucoma Progression With Trend Analyses
Nouri‐Mahdavi, K. (2011) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2011.224 · Cited by 56
Thermal response test and numerical analysis based on two models for ground-source heat pump system
Yu, X., Zhang, Y., Deng, N., Wang, J., Zhang, D., & Wang, J. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.07.074 · Cited by 56
Wideband enhancement of television images for people with visual impairments
Peli, E., Kim, J., Yitzhak Yitzhaky, B., Goldstein, R. B., & Woods, R. L. (2004) · Journal of the Optical Society of America A · doi:10.1364/josaa.21.000937 · Cited by 56
Rotsika, V., Ginieri-Coccossis, M., Vlassopoulos, M., Papaeleftheriou, E., Sakellariou, K. R., Anagnostopoulos, D., Kokkevi, A., & Skevington, S. M. (2011) · Quality of Life Research · doi:10.1007/s11136-011-9857-z · Cited by 70
Nerurkar, N. L., Mauck, R. L., & Elliott, D. M. (2011) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-011-0288-0 · Cited by 62
Test–retest reliability of quadriceps muscle function outcomes in patients with knee osteoarthritis
Staehli, S., Item‐Glatthorn, J. F., Casartelli, N. C., & Maffiuletti, N. A. (2010) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2010.07.006 · Cited by 62
Grubb, M., Carpenter, J., Crowe, J. A., Teoh, J. Y., Marlow, N., Ward, C., Mann, C., Sharkey, D., & Hayes‐Gill, B. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/5/881 · Cited by 58
Dodgson, K., Gedge, L., Murray, D. C., & Coldwell, M. C. (2009) · Journal of Receptors and Signal Transduction · doi:10.1080/10799890903079844 · Cited by 59
A comparison of two different techniques for early correction of Class III malocclusion
Seehra, J., Fleming, P. S., Mandall, N., & DiBiase, A. T. (2011) · The Angle Orthodontist · doi:10.2319/032011-197.1 · Cited by 56
Kopterides, P., Bonovas, S., Mavrou, I., Kostadima, E., Zakynthinos, E. G., & Armaganidis, A. (2009) · Shock · doi:10.1097/shk.0b013e31818bb8d8 · Cited by 56
Knobel, Z., Kellenberger, C. J., Kaiser, T., Albisetti, M., Bergsträßer, E., & Buechel, E. R. V. (2010) · International journal of cardiac imaging · doi:10.1007/s10554-010-9672-6 · Cited by 56
Comparison of Two Pain Assessment Tools in Nonverbal Critical Care Patients
Paulson-Conger, M., Leske, J. S., Maidl, C., Hanson, A. C., & Dziadulewicz, L. (2010) · Pain Management Nursing · doi:10.1016/j.pmn.2010.05.008 · Cited by 56
Validating Imaging Biomarkers of Cerebral Edema in Patients With Severe Ischemic Stroke
Yoo, A. J., Sheth, K. N., Kimberly, W. T., Chaudhry, Z. A., Elm, J., Jacobson, S., Davis, S. M., Donnan, G. A., Albers, G. W., Stern, B. J., et al. (2012) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2012.01.002 · Cited by 56
Soisson, V., Brailly‐Tabard, S., Empana, J. P., Féart, C., Ryan, J. L., Bertrand, M., Guiochon‐Mantel, A., & Scarabin, P. (2012) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2012.05.009 · Cited by 59
Measurement of Anterior Scleral Curvature Using Anterior Segment OCT
Choi, H. J., Lee, S. M., Lee, J. Y., Lee, S. Y., Kim, M. K., & Wee, W. R. (2014) · Optometry and Vision Science · doi:10.1097/opx.0000000000000298 · Cited by 56
Dennison, J. L., Stack, J., Beatty, S., & Nolan, J. M. (2013) · Experimental Eye Research · doi:10.1016/j.exer.2013.08.014 · Cited by 56
Blomberg, B. A., Thomassen, A., Takx, R. A. P., Vilstrup, M. H., Hess, S., Nielsen, A. L., Diederichsen, A. C. P., Mickley, H., Alavi, A. A., & Høilund‐Carlsen, P. F. (2013) · Journal of Nuclear Cardiology · doi:10.1007/s12350-013-9829-5 · Cited by 56
Gelsomino, S., Lorusso, R., Capecchi, I., Rostagno, C., Romagnoli, S., Billè, G., Cicco, G. D., Tetta, C., Stefàno, P., & Gensini, G. F. (2008) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2007.12.074 · Cited by 56
Wheelchair configuration and postural alignment in persons with spinal cord injury
Hastings, J. D., Fanucchi, E. R., & Burns, S. P. (2003) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2003.50036 · Cited by 56
van Heijst, A. F. J., van der Staak, F. H., Haan, A. F. D., Liem, K. D., Festen, C., Geven, W. B., & van de Bor, M. (2001) · ASAIO Journal · doi:10.1097/00002480-200107000-00015 · Cited by 56
Accuracy and Precision of EyeSys and Orbscan Systems on Calibrated Spherical Test Surfaces
González-Pérez, J., Cerviño, A., Giraldez, M. J., Parafita, M. Á., & Yebra‐Pimentel, E. (2004) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/01.icl.0000111749.04644.92 · Cited by 56
Lambrick, D., Faulkner, J., Rowlands, A. V., & Eston, R. G. (2009) · European Journal of Applied Physiology · doi:10.1007/s00421-009-1093-7 · Cited by 77
Sacré, P., Deconinck, E., Chiap, P., Crommen, J., Mansion, F., Rozet, E., Courselle, P., & Beer, J. O. D. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.07.029 · Cited by 56
Young, C. C., Mark, J. B., White, W. D., DeBree, A., Vender, J. S., & Fleming, A. J. (1995) · The Journal of Clinical Monitoring · doi:10.1007/bf01617519 · Cited by 56
Screening and determination of melamine residues in tissue and body fluid samples
Wang, Z., Ma, X., Zhang, L., Yang, W., Gong, L., He, P., & Li, Z. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.01.004 · Cited by 56
Kobashi, H., Kamiya, K., Igarashi, A., Ishii, R., Sato, N., Wang, G., & Shimizu, K. (2012) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2011.11.026 · Cited by 56
Sawit, S. T., García‐Álvarez, A., Suri, B., Gaztañaga, J., Fernández‐Friera, L., Mirelis, J. G., D'Anca, M., Fuster, V., Sanz, J., & Garcia, M. J. (2012) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2011.10.028 · Cited by 60
Repeatability of renal arterial spin labelling MRI in healthy subjects
Cutajar, M., Thomas, D. L., Banks, T., Clark, C. A., Golay, X., & Gordon, I. (2012) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-011-0300-9 · Cited by 56
Elhan, A. H., Öztuna, D., Kutlay, Ş., Küçükdeveci, A. A., & Tennant, A. (2008) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-9-166 · Cited by 64
Poor sleep in organ transplant recipients: self‐reports and actigraphy
Reilly-Spong, M., Park, T., & Gross, C. R. (2013) · Clinical Transplantation · doi:10.1111/ctr.12255 · Cited by 59
Liou, T., Chan, W. P., Pan, L.-C., Lin, P.-W., Chou, P., & Chen, C. (2006) · International Journal of Obesity · doi:10.1038/sj.ijo.0803216 · Cited by 56
EMG Threshold Determination in Eight Lower Limb Muscles During Cycling Exercise: A Pilot Study
Hug, F., Laplaud, D., Lucía, A., & Grélot, L. (2006) · International Journal of Sports Medicine · doi:10.1055/s-2005-865787 · Cited by 60
Chuang, L.-L., Lin, K., Wu, C., Chang, C., Chen, H., Yin, H.-P., & Wang, L. (2012) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2012.08.212 · Cited by 56
Ruggeri, A., Scarpa, F., Luca, M., Meltendorf, C., & Schroeter, J. (2010) · British Journal of Ophthalmology · doi:10.1136/bjo.2009.166561 · Cited by 56
Li, Y., Yang, Z.-G., Chen, T.-W., Yu, J.-Q., Sun, J.-Y., & Chen, H.-J. (2010) · British Journal of Radiology · doi:10.1259/bjr/58020866 · Cited by 56
Moore, C. C., Jacob, S. T., Jacob, S. T., Pinkerton, R., Meya, D. B., Mayanja‐Kizza, H., Reynolds, S. J., & Scheld, W. M. (2007) · Clinical Infectious Diseases · doi:10.1086/524665 · Cited by 57
A Vertical VAS is a Valid Instrument for Monitoring Headache Pain Intensity
Lundqvist, C., Benth, J. Š., Grande, R., Aaseth, K., & Russell, M. (2009) · Cephalalgia · doi:10.1111/j.1468-2982.2008.01833.x · Cited by 61
Pre-radiotherapy FDG PET predicts radiation pneumonitis in lung cancer
Castillo, R., Pham, N. T. T., Ansari, S. J., Meshkov, D., Castillo, S., Li, M., Olanrewaju, A., Hobbs, B. P., Castillo, E. M., & Guerrero, T. M. (2014) · Radiation Oncology · doi:10.1186/1748-717x-9-74 · Cited by 56
Alison, J. A., Kenny, P., King, M. T., McKinley, S., Aitken, L. M., Leslie, G. D., & Elliott, D. (2012) · Physical Therapy · doi:10.2522/ptj.20110410 · Cited by 57
Improving the precision of QT measurements.
Darpö, B., Fossa, A. A., Couderc, J., Zhou, M., Schreyer, A., Ticktin, M., & Zapesochny, A. (2011) · PubMed · Cited by 60
Estimation of Daily Human Intake of Food Flavonoids
Mullie, P., Clarys, P., Deriemaeker, P., & Hebbelinck, M. (2007) · Plant Foods for Human Nutrition · doi:10.1007/s11130-007-0047-7 · Cited by 56
Okubo, H., Murakami, K., Sasaki, S., Kim, M. K., Hirota, N., Notsu, A., Fukui, M., & Date, C. (2010) · Public Health Nutrition · doi:10.1017/s1368980009993211 · Cited by 58
Extrinsic and intrinsic risk factors associated with injuries in young dancers aged 8–16 years
Steinberg, N., Siev‐Ner, I., Peleg, S., Dar, G., Masharawi, Y., Zeev, A., & Hershkovitz, I. (2012) · Journal of Sports Sciences · doi:10.1080/02640414.2011.647705 · Cited by 56
The craniofacial characteristics of osteogenesis imperfecta patients
Chang, P.-C., Lin, S.-Y., & Hsu, K. (2006) · European Journal of Orthodontics · doi:10.1093/ejo/cjl035 · Cited by 56
The intra- and inter-rater reliability of X-ray radiological measurements for patellar instability
Smith, T. O., Cogan, A., Patel, S., Shakokani, M., Toms, A. P., & Donell, S. T. (2012) · The Knee · doi:10.1016/j.knee.2012.05.011 · Cited by 60
Donadio, C., Halim, A. B., Caprio, F., Grassi, G., Khedr, B., & Mazzantini, M. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/6/s43 · Cited by 64
Ponzini, R., Vergara, C., Rizzo, G., Veneziani, A., Roghi, A., Vanzulli, A., Parodi, O., & Redaelli, A. C. L. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2046484 · Cited by 66
Mattsson, T. O., Knudsen, J. L., Lauritsen, J., Brixen, K., & Herrstedt, J. (2013) · BMJ Quality & Safety · doi:10.1136/bmjqs-2012-001219 · Cited by 67
Miller, W. C., Deathe, A. B., & Harris, J. E. (2004) · Clinical Rehabilitation · doi:10.1191/0269215504cr728oa · Cited by 61
Mok, É., Letellier, G., Cuisset, J., Denjean, A., Gottrand, F., & Hankard, R. (2010) · Clinical Nutrition · doi:10.1016/j.clnu.2010.03.011 · Cited by 60
Assessment of left ventricular function by GPs using pocket-sized ultrasound
Mjølstad, O. C., Snare, S. R., Folkvord, L., Helland, F., Grimsmo, A., Torp, H. G., Haraldseth, O., & Haugen, B. O. (2012) · Family Practice · doi:10.1093/fampra/cms009 · Cited by 56
Desch, S., Engelhardt, H., Meissner, J., Eitel, I., Sareban, M., Fuernau, G. F., de Waha, S., Grothoff, M., Gutberlet, M., Schuler, G. C., et al. (2011) · International journal of cardiac imaging · doi:10.1007/s10554-011-9802-9 · Cited by 56
Mueller, S., Durango, E., Dietrich, C., Seitz, H. K., Kunz, C. U., Pomier–Layrargues, G., Duarte-Rojo, Beaton, Elkhashab, & Myers (2013) · Hepatic Medicine Evidence and Research · doi:10.2147/hmer.s45234 · Cited by 65
McNamara, H., Barclay, P., & Sharma, V. (2014) · British Journal of Anaesthesia · doi:10.1093/bja/aeu162 · Cited by 56
Klooster, R. V. ’., de Koning, P. J. H., Dehnavi, R. A., Tamsma, J. T., Roos, A., Reiber, J. H. C., & van der Geest, R. J. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22809 · Cited by 56
Reproducibility of ultrasound and magnetic resonance imaging measurements of tendon size
Brushøj, C., Henriksen, B. M., Albrecht‐Beste, E., Hölmich, P., Larsen, K., & Nielsen, M. B. (2006) · Acta Radiologica · doi:10.1080/02841850600854936 · Cited by 56
Comparison of Broselow tape measurements versus physician estimations of pediatric weights
Rosenberg, M., Greenberger, S., Rawal, A., Latimer-Pierson, J., & Thundiyil, J. G. (2010) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2009.12.002 · Cited by 57
Park, J. H., Yoon, J. W., Shin, Y. H., Jee, H. M., Wee, Y. S., Chang, S. J., Sim, J. H., Yum, H. Y., & Han, M. Y. (2011) · Korean Journal of Pediatrics · doi:10.3345/kjp.2011.54.2.64 · Cited by 74
Cheminant, M., Derrieux, C., Touzart, A., Schmit, S. L., Grenier, A., Trinquand, A., Delfau‐Larue, M., Lhermitte, L., Thiéblemont, C., Ribrag, V., et al. (2015) · Haematologica · doi:10.3324/haematol.2015.134957 · Cited by 56
Ishida, M., Kitagawa, K., Ichihara, T., Natsume, T., Nakayama, R., Nagasawa, N., Kubooka, M., Ito, T., Uno, M., Goto, Y., et al. (2016) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2016.01.008 · Cited by 56
Mair, B., Drillich, M., Klein-Jöbstl, D., Kanz, P., Borchardt, S., Meyer, L., Schwendenwein, I., & Iwersen, M. (2016) · BMC Veterinary Research · doi:10.1186/s12917-016-0662-3 · Cited by 71
Assays for measurement of TNF antagonists in practice
Casteele, N. V. (2016) · Frontline Gastroenterology · doi:10.1136/flgastro-2016-100692 · Cited by 58
Yang, X.-X., Critchley, L. A. H., & Joynt, G. M. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181ff475e · Cited by 57
Dabrh, A. M. A., Ospina, N. S., Nofal, A. A., Farah, W. H., Barrionuevo, P., Sarigianni, M., Mohabbat, A. B., Benkhadra, K., Leon, B. G. C., Gionfriddo, M. R., et al. (2016) · Endocrine Practice · doi:10.4158/ep15922.ra · Cited by 65
Ekström, K., Lehtonen, J. Y. A., Hänninen, H., Kandolin, R. M., Kivistö, S., & Kupari, M. M. (2016) · Journal of the American Heart Association · doi:10.1161/jaha.115.003040 · Cited by 56
Breathing and Snoring Sound Characteristics during Sleep in Adults
Levartovsky, A., Dafna, E., Zigel, Y., & Tarasiuk, A. (2016) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.5588 · Cited by 56
Weinschenk, S. W., Beise, R. D., & Lorenz, J. (2016) · European Journal of Applied Physiology · doi:10.1007/s00421-016-3401-3 · Cited by 62
Li, G., Zheng, X., Gu, H., Li, X., Yuan, W. A., Chang, S., Fan, J., Calimente, H., & Hu, J. (2016) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25351 · Cited by 59
Should the diagnosis of COPD be based on a single spirometry test?
Schermer, T. R., Robberts, B., Crockett, A. J., Thoonen, B. P. A., Lucas, A. E. M., Grootens, J., Smeele, I. J. M., Thamrin, C., & Reddel, H. K. (2016) · npj Primary Care Respiratory Medicine · doi:10.1038/npjpcrm.2016.59 · Cited by 57
A Longitudinal Study of Physical Fitness in Elite Junior Tennis Players
Kramer, T., Huijgen, B. C. H., Elferink-Gemser, M. T., & Visscher, C. (2016) · Pediatric Exercise Science · doi:10.1123/pes.2016-0022 · Cited by 56
Cloud Computing-Based Non-Invasive Glucose Monitoring for Diabetic Care
Pai, P. P., Sanki, P. K., Sahoo, S. K., De, A., Bhattacharya, S., & Banerjee, S. (2017) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2017.2724012 · Cited by 63
Validation of equations for pleural effusion volume estimation by ultrasonography
Hassan, M., Rizk, R., Essam, H., & Abouelnour, A. F. (2017) · Journal of Ultrasound · doi:10.1007/s40477-017-0266-1 · Cited by 56
A multicentre verification study of the QuantiFERON®-TB Gold Plus assay
Pieterman, E. D., Lung, F. G. L., Verbon, A., Bax, H. I., Ang, C. W., Berkhout, J., Blaauw, G. J., Brandenburg, A., van Burgel, N. D., Claessen, A. M. E., et al. (2017) · Tuberculosis · doi:10.1016/j.tube.2017.11.014 · Cited by 58
Rahman, H., Ahmed, M. U., & Begum, S. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2908349 · Cited by 60
Aoun, C., Daher, R. B., Osta, N. E., Papazian, T., & Khabbaz, L. R. (2019) · PLoS ONE · doi:10.1371/journal.pone.0218541 · Cited by 65
Du, C., Li, B., Li, Y., Xu, M., & Yao, R. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106349 · Cited by 58
Real-life inhaler adherence and technique: Time to get smarter!
Chrystyn, H., Audibert, R., Keller, M., Quaglia, B., Vecellio, L., & Roche, N. (2019) · Respiratory Medicine · doi:10.1016/j.rmed.2019.09.008 · Cited by 62
Hafizah, Y. N., Ang, L. C., Yap, F., Nik, W. N. N. W., Cheah, W. L., Talib, R. A., Jumuddin, F. A., Koh, D., Lee, J. A. C., Essau, C. A., et al. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16234722 · Cited by 65
Reliability and validity analyzes of Kinect V2 based measurement system for shoulder motions
Çubukçu, B., Yüzgeç, U., Zileli, R., & Zileli, A. (2019) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2019.10.017 · Cited by 66
Blood eosinophil count as predictor of asthma exacerbation. A meta‐analysis
Mallah, N., Rodriguez‐Segade, S., González‐Barcala, F. J., & Takkouche, B. (2020) · Pediatric Allergy and Immunology · doi:10.1111/pai.13403 · Cited by 63
Tack, A., Preim, B., & Zachow, S. (2021) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2021.106080 · Cited by 69
Mascherini, G., Catelan, D., Pellegrini-Giampietro, D. E., Petri, C., Scaletti, C., & Gulisano, M. (2021) · PLoS ONE · doi:10.1371/journal.pone.0252395 · Cited by 66
Relationship of Health-Related Quality of Life to Symptom Severity in Diabetes Mellitus
Gulliford, M. C., & Mahabir, D. (1999) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(99)00053-0 · Cited by 57
Evaluation of absolute quantitation by nonlinear regression in probe-based real-time PCR
Goll, R., Olsen, T., Cui, G., & Florholmen, J. (2006) · BMC Bioinformatics · doi:10.1186/1471-2105-7-107 · Cited by 57
Schimrigk, S., Bellenberg, B., Schlüter, M., Stieltjes, B., Drescher, R., Rexilius, J., Lukas, C., Hahn, H. K., Przuntek, H., & Köster, O. (2007) · PubMed Central · Cited by 67
Calculating the direct costs of urinary incontinence: a new test instrument
Dowell, Bryant, Moore, K. H., & Simons (1999) · British Journal of Urology · doi:10.1046/j.1464-410x.1999.00993.x · Cited by 56
Arcot, J., Shrestha, A. K., & Gusanov, U. (2002) · Food Control · doi:10.1016/s0956-7135(02)00018-x · Cited by 67
Buchholz, A. C., McGillivray, C. F., & Pencharz, P. B. (2003) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(02)04950-x · Cited by 63
Kato, M., Saito, M., Fukuda, S., Kato, C., Ohara, S., Hamada, S., Nagashima, R., Obara, K., Suzuki, M., Honda, H., et al. (2004) · Journal of Gastroenterology · doi:10.1007/s00535-003-1357-7 · Cited by 56
The Response to Visual Form Deprivation Differs with Age in Marmosets
Troilo, D., & Nickla, D. L. (2005) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.04-1422 · Cited by 59
Siervo, M., Faber, P., Gibney, E. R., Lobley, G. E., Elia, M., Stubbs, R. J., & Johnstone, A. M. (2010) · International Journal of Obesity · doi:10.1038/ijo.2010.9 · Cited by 63
A Comparison of Footprint Indexes Calculated from Ink and Electronic Footprints
Urry, S. R., & Wearing, S. C. (2001) · Journal of the American Podiatric Medical Association · doi:10.7547/87507315-91-4-203 · Cited by 56
Investigation of voiding dysfunction in a population-based sample of children aged 3 to 9 years
Mota, D. M., Victora, C. G., & Hallal, P. C. (2005) · Jornal de Pediatria · doi:10.1590/s0021-75572005000400009 · Cited by 56
Fillipas, S., Cicuttini, F., Holland, A. E., & Cherry, C. L. (2010) · Journal of the Association of Nurses in AIDS Care · doi:10.1016/j.jana.2009.11.003 · Cited by 64
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.