Activation-induced T-cell death and immune dysfunction after implantation of left-ventricular assist de vice
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Cardiac transplantation is a limited option for end-stage heart failure because of the shortage of donor organs. Left-ventricular assist devices (LVADs) are currently under investigation as permanent therapy for end-stage heart failure, but long-term successful device implantation is limited because of a high rate of serious infections. To examine the relation between LVAD-related infection and host immunity, we investigated immune responses in LVAD recipients. METHODS: We compared the rate of candidal infection in 78 patients with New York Heart Association class IV heart failure who received either an LVAD (n=40) or medical management (controls, n=38). Fluorochrome-labelled monoclonal antibodies were used in analyses of T-cell phenotype. Analysis of T-cell function included intradermal responses to recall antigens and proliferative responses after stimulation by phytohaemagglutinin, monoclonal antibodies to CD3, and mixed lymphocyte culture. We measured T-cell apoptosis in vivo by annexin V binding, and confirmed the result by assessment of DNA fragmentation. Activation-induced T-cell death was measured after T-cell stimulation with antibodies to CD3. All immunological tests were done at least 1 month after LVAD implantation. Between-group comparisons were by Kaplan-Meier actuarial analysis and Student's t test. FINDINGS: By 3 months after implantation of LVAD, the risk of developing candidal infection was 28% in LVAD recipients, compared with 3% in controls (p=0.003). LVAD recipients had cutaneous anergy to recall antigens and lower (<70%) T-cell proliferative responses than controls after activation via the T-cell receptor complex (p<0.001). T cells from LVAD recipients had higher surface expression of CD95 (Fas) (p<0.001) and a higher rate of spontaneous apoptosis (p<0.001) than controls. Moreover, after stimulation with antibodies to CD3, CD4 T-cell death increased by 3.2-fold in LVAD recipients compared with only 1.2-fold in controls (p<0.05). INTERPRETATION: LVAD implantation results in an aberrant state of T-cell activation, heightened susceptibility of CD4 T cells to activation-induced cell death, progressive defects in cellular immunity, and increased risk of opportunistic infection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vermes, I., Haanen, C., Steffens-Nakken, H., & Reutellingsperger, C. (1995) · Journal of Immunological Methods · doi:10.1016/0022-1759(95)00072-i · Cited by 5,410
Effects of Enalapril on Mortality in Severe Congestive Heart Failure
The Consensus Trial Study Group* (1987) · New England Journal of Medicine · doi:10.1056/nejm198706043162301 · Cited by 5,121
HIV-1 Dynamics in Vivo: Virion Clearance Rate, Infected Cell Life-Span, and Viral Generation Time
Perelson, A. S., Neumann, A. U., Markowitz, M., Leonard, J. M., & Ho, D. D. (1996) · Science · doi:10.1126/science.271.5255.1582 · Cited by 3,531
Koopman, G., Reutelingsperger, C., Kuijten, G., Keehnen, R., Pals, S., & van Oers, M. (1994) · Blood · doi:10.1182/blood.v84.5.1415.1415 · Cited by 2,681
Pantaleo, G., Graziosi, C., Demarest, J. F., Butini, L., Montroni, M., Fox, C. H., Orenstein, J. M., Kotler, D. P., & Fauci, A. S. (1993) · Nature · doi:10.1038/362355a0 · Cited by 1,808
Fas(CD95)/FasL interactions required for programmed cell death after T-cell activation
Ju, S.-T., Panka, D. J., Cui, H., Ettinger, R., EI-Khatib, M., Sherr, D. H., Stanger, B. Z., & Marshak-Rothstein, A. (1995) · Nature · doi:10.1038/373444a0 · Cited by 1,499
Groux, H., Torpier, G., Monté, D., Mouton, Y., Capron, A., & Ameisen, J. C. (1992) · The Journal of experimental medicine · doi:10.1084/jem.175.2.331 · Cited by 881
Prevalence and mortality rate of congestive heart failure in the United States
Schocken, D. D., Arrieta, M. I., Leaverton, P. E., & Ross, E. A. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90094-4 · Cited by 817
Weiss, R. A. (1993) · Science · doi:10.1126/science.8493571 · Cited by 680
Cell dysfunction and depletion in AIDS: the programmed cell death hypothesis
Claude Ameisen, J., & Capron, A. (1991) · Immunology Today · doi:10.1016/0167-5699(91)90092-8 · Cited by 530
Katsikis, P. D., Wunderlich, E. S., Smith, C. A., Herzenberg, L. A., & Herzenberg, L. A. (1995) · The Journal of experimental medicine · doi:10.1084/jem.181.6.2029 · Cited by 421
Tilly, J. L., & Hsueh, A. J. W. (1993) · Journal of Cellular Physiology · doi:10.1002/jcp.1041540310 · Cited by 340
Activation of coagulation and fibrinolytic pathways in patients with left ventricular assist devices
Spanier, T., Oz, M., Levin, H., Weinberg, A., Stamatis, K., Stern, D., Rose, E., & Schmidt, A. M. (1996) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(96)70111-3 · Cited by 158
Self-citationItescu, S., Tung, T., Burke, E. M., Weinberg, A. D., Moazami, N., Artrip, J. H., Suciu‐Foca, N., Rose, E. A., Öz, M. C., & Michler, R. E. (1998) · Circulation · doi:10.1161/01.cir.98.8.786 · Cited by 152
Self-citationInfectious Complications in Left Ventricular Assist Device Recipients
Fischer, S. A., Trenholme, G. M., Costanzo, M. R., & Piccione, W. J. (1997) · Clinical Infectious Diseases · doi:10.1093/clinids/24.1.18 · Cited by 123
Brunner, T., Yoo, N. J., LaFace, D., Ware, C. F., & Green, D. R. (1996) · International Immunology · doi:10.1093/intimm/8.7.1017 · Cited by 121
Severe sepsis in cardiac surgical patients
Michalopoulos, A. S., Stavridis, G. T., & Geroulanos, S. (2002) · The European Journal of Surgery · doi:10.1080/110241598750004670 · Cited by 60
The immunology of primary HIV infection: which immune responses control HIV replication?
Safrit, J. T., & Koup, R. A. (1995) · Current Opinion in Immunology · doi:10.1016/0952-7915(95)80088-3 · Cited by 59
Evaluation of bioprosthetic valve-associated thrombus in ventricular assist device patients.
Wagner, W. R., Johnson, P. C., Kormos, R. L., et al. (1993) · Circulation · doi:10.1161/01.cir.88.5.2023 · Cited by 57
Holman, W. L., Murrah, C. P., Ferguson, E. R., Bourge, R. C., McGiffin, D. C., & Kirklin, J. K. (1996) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(95)01021-1 · Cited by 52
Current Concepts of Thrombosis and Infection in Artificial Organs
Didisheim, P. (1994) · ASAIO Journal · doi:10.1097/00002480-199404000-00020 · Cited by 31
Cited by
A Fully Magnetically Levitated Left Ventricular Assist Device — Final Report
Mehra, M. R., Uriel, N., Naka, Y., Cleveland, J. C., Yuzefpolskaya, M., Salerno, C. T., Walsh, M. N., Milano, C. A., Patel, C. B., Hutchins, S. W., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1900486 · Cited by 1,312
Nonvalvular Cardiovascular Device–Related Infections
Baddour, L. M., Bettmann, M. A., Bolger, A. F., Epstein, A. E., Ferrieri, P., Gerber, M. A., Gewitz, M. H., Jacobs, A. K., Levison, M. E., Newburger, J. W., et al. (2003) · Circulation · doi:10.1161/01.cir.0000093201.57771.47 · Cited by 496
NKILA lncRNA promotes tumor immune evasion by sensitizing T cells to activation-induced cell death
Huang, D., Chen, J., Yang, L., Ouyang, Q., Li, J., Lao, L., Zhao, J., Liu, J., Lu, Y., Xing, Y., et al. (2018) · Nature Immunology · doi:10.1038/s41590-018-0207-y · Cited by 448
Bader, F., Manla, Y., Atallah, B., & Starling, R. C. (2021) · Heart Failure Reviews · doi:10.1007/s10741-020-10008-2 · Cited by 259
Biocompatibility of implants: lymphocyte/macrophage interactions
Anderson, J. M., & McNally, A. K. (2011) · Seminars in Immunopathology · doi:10.1007/s00281-011-0244-1 · Cited by 226
Metadata
- Authors
- Ankersmit, H. J., Tugudea, S., Spanier, T., Weinberg, A. D., Artrip, J. H., Burke, E. M., Flannery, M., Mancini, D., Rose, E. A., Edwards, N. M., Oz, M. C., & Itescu, S.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1999-08
- Volume
- 354
- Issue
- 9178
- Pages
- 550-555
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2077907010
- Cited by
- 194
- References
- 21
- FWCI
- 12.96
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.