Biostability of micro‐photodiode arrays for subretinal implantation
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Micro-photodiode arrays based on semiconductor chip technology are being developed to replace degenerated photoreceptor cells in the retina. Electric current is generated in tiny micro-photodiodes and delivered to the adjacent tissue by micro-electrodes. One of the main requirements of a sub-retinal implantable device is long-term stability versus corrosion in vivo (biostability). Biostability of micro-photodiode arrays (MPDA) was investigated in vitro and in vivo. No significant damage was found on chips immersed for up to 21 months in saline solution. Under in vivo conditions, however, the silicon oxide passivation layer of the chip was dissolved within a period of about 6-12 months. Subsequently, the underlying silicon was corroded. In contrast, stimulation electrodes consisting of titanium nitride were well preserved both in vitro and in vivo. The deterioration of the electrical properties of the micro-photodiodes correlated with the morphological damage observed. Strategies aiming at the development of an improved biostable encapsulation of neurotechnological implants have to be investigated and will be discussed briefly.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“If parts of standard electronic processes were directly transferred for implant passivation, degradation during implantation deteriorated not only the insulation layer but also functional integrated structures within 1 year (Haemmerle et al., 2002)”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Haemmerle et al., 2002
Citations
Cites
Electrochemical Methods: Fundamentals and Applications
Bard, A. J., & Faulkner, L. R. (1980) · Cited by 22,847
Visual Perception Elicited by Electrical Stimulation of Retina in Blind Humans
Humayun, M. S. (1996) · Archives of Ophthalmology · doi:10.1001/archopht.1996.01100130038006 · Cited by 601 · cited 1×
“the neuronal network, survive for an extended period of time [1,2].”
BackgroundPattern electrical stimulation of the human retina
Humayun, M. S., de Juan Jr., E., Weiland, J. D., Dagnelie, G., Katona, S., Greenberg, R., & Suzuki, S. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00052-8 · Cited by 592 · cited 1×
“the neuronal network, survive for an extended period of time [1,2].”
BackgroundCan subretinal microphotodiodes successfully replace degenerated photoreceptors?
Zrenner, E., Stett, A., Weiss, S., Aramant, R. B., Guenther, E., Kohler, K., Miliczek, K.-D., Seiler, M. J., & Haemmerle, H. (1999) · Vision Research · doi:10.1016/s0042-6989(98)00312-5 · Cited by 290
Learning Retina Implants with Epiretinal Contacts
Eckmiller, R. (1997) · Ophthalmic Research · doi:10.1159/000268026 · Cited by 257 · cited 1×
“Only quite recently implants intended for functional stimulation of neurons in the retina have been developed and implanted into animal models [10–13,3,4].”
MethodSubretinal electrical stimulation of the rabbit retina
Chow, A. Y., & Chow, V. Y. (1997) · Neuroscience Letters · doi:10.1016/s0304-3940(97)00185-7 · Cited by 242 · cited 1×
“[5–8].”
Egert, U., Schlosshauer, B., Fennrich, S., Nisch, W., Fejtl, M., Knott, T., Müller, T., & Hämmerle, H. (1998) · Brain Research Protocols · doi:10.1016/s1385-299x(98)00013-0 · Cited by 241
Self-citationThe Development of Subretinal Microphotodiodes for Replacement of Degenerated Photoreceptors
Zrenner, E., Miliczek, K.-D., Gabel, V. P., Graf, H. G., Guenther, E., Haemmerle, H., Hoefflinger, B., Kohler, K., Nisch, W., Schubert, M., et al. (1997) · Ophthalmic Research · doi:10.1159/000268025 · Cited by 214 · cited 2×
“Prototype devices have already been implanted subretinally in animals between the neuronal layer and the pigment epithelium [3,4].”
BackgroundMethodSelf-citationBrummer, S. B., Robblee, L. S., & Hambrecht, F. T. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31628.x · Cited by 205 · cited 1×
“02mC/cm are in good agreement with the earlier reports of capacitance measurements on planar stimulation electrodes [15].”
ResultBiomaterials used in the posterior segment of the eye
Colthurst, M. J., Williams, R. L., Hiscott, P. S., & Grierson, I. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00220-3 · Cited by 162 · cited 1×
“[9].”
Research works printed but not linked: 2
- Chow, 1993, Electrical stimulation of the rabbit retina with subretinal electrodes and high density microphotodiode array implants, Invest Ophtalmol Vis Sci (Suppl), 34, 835
- Chow, 1998, Retinal and cortical potentials induced by subretinally implanted microphotodiode arrays, Invest Ophthalmol Vis Sci (Suppl), 39, 565
Cited by
Small-scale systems for in vivo drug delivery
LaVan, D. A., McGuire, T., & Langer, R. (2003) · Nature Biotechnology · doi:10.1038/nbt876 · Cited by 1,304
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
“If parts of standard electronic processes were directly transferred for implant passivation, degradation during implantation deteriorated not only the insulation layer but also functional integrated structures within 1 year (Haemmerle et al., 2002).”
MethodNeural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655
Biocompatibility and biofouling of MEMS drug delivery devices
Voskerician, G., Shive, M. S., Shawgo, R. S., Recum, H. V., Anderson, J. M., Cima, M. J., & Langer, R. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00565-3 · Cited by 558
“Others have reported on the potential corrosion in vivo of a silicon oxide passivating layer occurring as early as 1 month in a sensor array, reducing the overall biocompatibility of the device over time [18,21,22].”
BackgroundControl of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
“(73) Beyond the removal of the as-fabricated silicon oxide surface layer within 12 months of implantation, Hämmerle and colleagues also observed progressive corrosion of their underlying silicon substrate.”
BackgroundDesign of a high-resolution optoelectronic retinal prosthesis
Palanker, D., Vankov, A., Huie, P., & Baccus, S. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/012 · Cited by 334
“Limits are imposed by maximal charge density on Pt, TiN and IrO x electrodes. electrodes in the array are separated by the three radii of the electrode (the cross-talk limit), the maximal pixel density can be then calculated as n = 1 9r 2 0 .”
BackgroundResultInfluentialMolinari, V., Giordano, C., Antonietti, M., & Esposito, D. (2014) · Journal of the American Chemical Society · doi:10.1021/ja4119412 · Cited by 230
Biomaterials‐Based Electronics: Polymers and Interfaces for Biology and Medicine
Muskovich, M., & Bettinger, C. J. (2012) · Advanced Healthcare Materials · doi:10.1002/adhm.201200071 · Cited by 182
Winslow, B. D., Christensen, M. B., Yang, W.-K., Solzbacher, F., & Tresco, P. A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.05.050 · Cited by 171
“The current study demonstrates that a major difference in surface chemistry of implanted planar microelectrode arrays does not significantly change the foreign body response, indicating that the previously reported foreign body response (FBR) to SiMEAs was not due to changing composition or decomposition of the silico…”
Plasma‐enhanced chemical vapor deposited silicon carbide as an implantable dielectric coating
Cogan, S. F., Edell, D. J., Guzelian, A. A., Ping Liu, Y., & Edell, R. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10152 · Cited by 169
Materials for microfabricated implantable devices: a review
Scholten, K., & Meng, E. (2015) · Lab on a Chip · doi:10.1039/c5lc00809c · Cited by 161
Nitrogen-rich transition metal nitrides
Salamat, A., Hector, A. L., Kroll, P., & McMillan, P. F. (2013) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2013.01.010 · Cited by 162
Sputtered Iridium Oxide Films as Charge Injection Material for Functional Electrostimulation
Slavcheva, E., Vitushinsky, R., Mokwa, W., & Schnakenberg, U. (2004) · Journal of The Electrochemical Society · doi:10.1149/1.1747881 · Cited by 154
Xiao, X., Wang, J., Liu, C., Carlisle, J. A., Mech, B., Greenberg, R., Guven, D., Freda, R., Humayun, M. S., Weiland, J., et al. (2006) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30448 · Cited by 140
The Future of Neuroimplantable Devices: A Materials Science and Regulatory Perspective
Obidin, N., Tasnim, F., & Dagdeviren, C. (2020) · Advanced Materials · doi:10.1002/adma.201901482 · Cited by 126
Qiu, G., Thakur, A., Xu, C., Ng, S., Lee, Y., & Wu, C. L. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201806761 · Cited by 126
Microsystem technologies for implantable applications
Receveur, R. A. M., Lindemans, F. W., & de Rooij, N. F. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/5/r02 · Cited by 142
“The materials include silicon [7, 18, 154], silicon dioxide [18, 51, 133, 154], silicon nitride [18, 51, 133], silicon carbide [294], titanium nitride [154], poly-silicon [193–196], parylene [74, 131], epoxy [10, 74, 131], polyimide [3, 10, 13, 17, 131], polyester [3], silicon rubber [3, 9, 131], gold [131], platinum…”
Caldwell, R., Street, M. G., Sharma, R., Takmakov, P., Baker, B., & Rieth, L. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2019.119731 · Cited by 100
Outer Retinal Degeneration: An Electronic Retinal Prosthesis as a Treatment Strategy
Loewenstein, J. I. (2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.4.587 · Cited by 102
Ultrananocrystalline diamond-CMOS device integration route for high acuity retinal prostheses
Ahnood, A., Escudie, M., Cicione, R., Abeyrathne, C. D., Ganesan, K., Fox, K. E., Garrett, D. J., Stacey, A. D., Apollo, N. V., Lichter, S. G., et al. (2015) · Biomedical Microdevices · doi:10.1007/s10544-015-9952-y · Cited by 90
“Conventional ASIC silicon devices without a suitable biocompatible and hermetic coating are not a viable device beyond short term, acute implantation experiments (Hämmerle et al. 2002) due to their tendency to leach toxic elements as well as degradation of the device overtime.”
BackgroundAchieving long-term stability of thin-film electrodes for neurostimulation
Oldroyd, P., & Malliaras, G. G. (2021) · Acta Biomaterialia · doi:10.1016/j.actbio.2021.05.004 · Cited by 99
“However, this method does not capture some of the degradation mechanisms that occur in vivo, such as the effects of proteins, thus resulting in dramatic differences in reported failure times [66].”
MethodIn vitro stability study of organosilane self-assemble monolayers and multilayers
Wang, A., Tang, H., Cao, T., Salley, S. O., & Ng, K. Y. S. (2005) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2005.05.008 · Cited by 87
The development of neural stimulators: a review of preclinical safety and efficacy studies
Shepherd, R. K., Villalobos, J., Burns, O., & Nayagam, D. A. X. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aac43c · Cited by 86
Stein, B. (2003) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2003.10.034 · Cited by 82
Bionic vision: system architectures – a review
Guenther, T., Lovell, N. H., & Suaning, G. J. (2012) · Expert Review of Medical Devices · doi:10.1586/erd.11.58 · Cited by 76
Selective Hydrogenation of Phenol
Kong, X., Gong, Y., Mao, S., & Wang, Y. (2018) · ChemNanoMat · doi:10.1002/cnma.201800031 · Cited by 83
Physiological Challenges for Intracortical Electrodes
Groothuis, J., Ramsey, N. F., Ramakers, G. M. J., & Plasse, G. (2013) · Brain stimulation · doi:10.1016/j.brs.2013.07.001 · Cited by 86
“Despite some concern regarding the use of silicon implants [47], silicon-based implants such as Michigan and Utah arrays appear not to exacerbate the FBR.”
Retrospective lifetime estimation of failed and explanted diamond-like carbon coated hip joint balls
Hauert, R., Falub, C. V., Thorwarth, G., Thorwarth, K., Affolter, C., Stiefel, M., Podleska, L. E., & Taeger, G. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.04.016 · Cited by 73
“[16] reported that micro-photodiode arrays (MPDA) immersed for up to 21 months in saline solution showed no significant damage.”
BackgroundNovel interfaces for light directed neuronal stimulation: advances and challenges
Bareket, L., & Hanein, Y. (2014) · International Journal of Nanomedicine · doi:10.2147/ijn.s51193 · Cited by 76
“Biocompatibility and stability of the device in a biological environment is important to allow long-term in vitro investigations and clearly for retinal prosthetic application.(10,39,41) Primarily, understanding the chronic effects of light is”
Heim, M., Yvert, B., & Kuhn, A. (2011) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2011.10.001 · Cited by 88
“…metal electrode is separated from the electrolyte by a dielectric material (TiN, Ta2O5) allowing charge to be injected into the tissue strictly by capacitive action (Hämmerle et al., 2002; Janders et al., 1996; Merrill et al., 2005; Norlin et al., 2005; Rose et al., 1985; Walter and Heimann, 2000).”
BackgroundManufacturing, assembling and packaging of miniaturized neural implants
Stieglitz, T. (2010) · Microsystem Technologies · doi:10.1007/s00542-009-0988-x · Cited by 79
“However, the appropriate deposition technique and combination layers of silicon oxide and silicon nitride proved to be stable ( Haemmerle et al. 2002 ).”
BackgroundSiC protective coating for photovoltaic retinal prosthesis
Lei, X., Kane, S., Cogan, S., Lorach, H., Galambos, L., Huie, P., Mathieson, K., Kamins, T., Harris, J., & Palanker, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046016 · Cited by 66
“Low temperature (395 °C) LPCVD silicon oxide (SiO2) implanted sub-retinally in rabbits was found to dissolve after 6–12 months [23].”
BackgroundVillalobos, J., Nayagam, D. A. X., Allen, P. J., McKelvie, P., Luu, C. D., Ayton, L. N., Freemantle, A. L., McPhedran, M., Basa, M., McGowan, C. C., et al. (2013) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.12-10843 · Cited by 63
Cortical stimulation mapping using epidurally implanted thin-film microelectrode arrays
Molina-Luna, K., Buitrago, M. M., Hertler, B., Schubring-Giese, M., Haiss, F., Nisch, W., Schulz, J. B., & Luft, A. R. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.10.025 · Cited by 74
Self-citationA review of in vivo animal studies in retinal prosthesis research
Bertschinger, D. R., Beknazar, E., Simonutti, M., Safran, A. B., Sahel, J., Rosolen, S. G., Picaud, S. A., & Salzmann, J. (2008) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-008-0891-7 · Cited by 68
“The species involved include rats (n=6) [26, 29, 76, 80, 81, 96], rabbits (n=14) [33, 36, 42, 72, 73, 90, 94, 95, 102, 103, 105, 106, 116, 121], cats (n=18) [18, 19, 21–23, 30, 32, 43, 78, 79, 82, 93, 98, 99, 101, 114, 117, 120], dogs (n=4) [16, 39, 40, 66], sheep (n=1) [51] and pigs/minipigs (n=9) [34, 42, 49, 59, 69…”
BackgroundLet There Be Light—Optoprobes for Neural Implants
Alt, M. T., Fiedler, E., Rudmann, L., Ordonez, J. S., Ruther, P., & Stieglitz, T. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2577518 · Cited by 68
“Promising results have been achieved using thin films of diamond-like carbon (DLC), ultrananocrystalline diamond (UNCD) [332], [333], siliconcarbide (SiC) [334], siliconoxide ðSiOxÞ [170], [335] or siliconnitride ðSixNyÞ [331], [336].”
BackgroundDowling, J. (2005) · Expert Review of Medical Devices · doi:10.1586/17434440.2.1.73 · Cited by 58
The chemistry of organo silanetriols
Pietschnig, R., & Spirk, S. (2016) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2016.03.010 · Cited by 57
Electrical Stimulation and Cellular Behaviors in Electric Field in Biomedical Research
Meng, S., Rouabhia, M., & Zhang, Z. (2021) · Materials · doi:10.3390/ma15010165 · Cited by 60
“Precious metals such as silver is often selected due to the relative ease in fabrication; however, they are very unstable over time [105].”
BackgroundWu, Y., Peng, Y., Bohra, H., Zou, J., Ranjan, V., Zhang, Y., Zhang, Q., & Wang, M. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b19631 · Cited by 55
Vision rehabilitation in the case of blindness
Veraart, C., Duret, F., Brelén, M., Oozeer, M., & Delbeke, J. (2004) · Expert Review of Medical Devices · doi:10.1586/17434440.1.1.139 · Cited by 57
Hauert, R., Thorwarth, G., Müller, U., Stiefel, M., Falub, C. V., Thorwarth, K., & Joyce, T. J. (2012) · Diamond and Related Materials · doi:10.1016/j.diamond.2012.02.001 · Cited by 48
Corrosion-resistant metal layers from a CMOS process for bioelectronic applications
Birkholz, M., Ehwald, K. ‐., Wolansky, D., Costina, I., Kaynak, C. B., Fröhlich, M., Beyer, H., Kapp, A., & Lisdat, F. (2009) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2009.09.075 · Cited by 45
Subretinal implantation and testing of polyimide film electrodes in cats
Sachs, H. G., Schanze, T., Wilms, M., Rentzos, A., Brunner, U., Gekeler, F., & Hesse, L. (2004) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-004-1049-x · Cited by 49
“These requirements are satisfactorily fulfilled by the platinized titanium nitrite electrodes on a polyimide film used in our experiments [15, 30].”
BackgroundSelf-citationEreifej, E. S., Smith, C. S., Meade, S. M., Chen, K., Feng, H., & Capadona, J. R. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201704420 · Cited by 52
BioMEMS for biosensors and closed-loop drug delivery
Coffel, J., & Nuxoll, E. E. (2018) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2018.01.030 · Cited by 46
“, 2005)) and their common deposition techniques are prone to producing pinholes (Hämmerle et al., 2002; Schmitt et al., 1999) which may be too small to matter in air-based insulating conditions, but which prove fatal to the underlying silicon when immersed in physiological liquids for an extended period.”
BackgroundUltrathin TiN Membranes as a Technology Platform for CMOS‐Integrated MEMS and BioMEMS Devices
Birkholz, M., Ehwald, K. ‐., Kulse, P., Drews, J., Fröhlich, M., Haak, U., Kaynak, M., Matthus, E., Schulz, K., & Wolansky, D. (2011) · Advanced Functional Materials · doi:10.1002/adfm.201002062 · Cited by 44
Nanbakhsh, K., Idil, A. S., Lamont, C. A., Dücső, C., Akgun, Ö. C., Horváth, D., Tóth, K., Meszéna, D., Ulbert, I., Mazza, F., et al. (2025) · Nature Communications · doi:10.1038/s41467-024-55298-4 · Cited by 52
Nanostructured Coatings for Improved Charge Delivery to Neurons
Kozai, T. D. Y., Alba, N. A., Zhang, H., Kotov, N. A., Gaunt, R. A., & Cui, X. T. (2014) · Springer eBooks · doi:10.1007/978-1-4899-8038-0_4 · Cited by 48
“Sputtered titanium nitride (TiN) microelectrodes have demonstrated good biocompatibility and relatively high charge injection capacities, which has made them the preferred electrode material for many stimulation electrode applications [117, 156, 166–168].”
BackgroundRoom Temperature Growth of Epitaxial Titanium Nitride Films by Pulsed Laser Deposition
Rasic, D., Sachan, R., Chisholm, M. F., Prater, J. T., & Narayan, J. (2017) · Crystal Growth & Design · doi:10.1021/acs.cgd.7b01278 · Cited by 39
In Vivo Biostability of CVD Silicon Oxide and Silicon Nitride Films
Maloney, J. M., Lipka, S. A., & Baldwin, S. P. (2005) · MRS Proceedings · doi:10.1557/proc-872-j14.3 · Cited by 47
“5 μm silicon oxide film deposited by LPCVD at a temperature of 395°C with tetraethylorthosilicate (TEOS) as a precursor gas [2].”
MethodSubretinal electrode implantation in the P23H rat for chronic stimulations
Salzmann, J. (2006) · British Journal of Ophthalmology · doi:10.1136/bjo.2005.089110 · Cited by 38
“techniques have been used in rabbits [9], minipigs [ 29 ] and cats [30].”
MethodFlexible neural interfaces for brain implants—the pursuit of thinness and high density
Araki, T., Bongartz, L. M., Kaiju, T., Takemoto, A., Tsuruta, S., Uemura, T., & Sekitani, T. (2020) · Flexible and Printed Electronics · doi:10.1088/2058-8585/abc3ca · Cited by 42
Immobilization of polysaccharides on a fluorinated silicon surface
Wang, A., Cao, T., Tang, H., Liang, X., Black, C., Salley, S. O., McAllister, J. P., Auner, G. W., & Ng, K. Y. S. (2006) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2005.11.016 · Cited by 40
Caldwell, R., Mandal, H., Sharma, R., Solzbacher, F., Tathireddy, P., & Rieth, L. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa69d3 · Cited by 36
“Materials used for this application include SiO2 or SiNx [10, 11], polyimide [12, 13], silicone [14], and parylene C [15–17].”
MethodSachs, H. G., Schanze, T., Brunner, U., Sailer, H., & Wiesenack, C. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/008 · Cited by 36
Self-citationBiocompatible ultrananocrystalline diamond coatings for implantable medical devices
Auciello, O. H., Gurman, P., Guglielmotti, M. B., Olmedo, D. G., Berra, A., & Saravia, M. (2014) · MRS Bulletin · doi:10.1557/mrs.2014.134 · Cited by 37
Popov, M. N., Bochkarev, A. S., Razumovskiy, V. I., Puschnig, P., & Spitaler, J. (2017) · Acta Materialia · doi:10.1016/j.actamat.2017.11.005 · Cited by 31
Technology modules from micro‐ and nano‐electronics for the life sciences
Birkholz, M., Mai, A., Wenger, C., Meliani, C., & Scholz, R. (2015) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1367 · Cited by 34
Diamond encapsulated photovoltaics for transdermal power delivery
Ahnood, A., Fox, K. E., Apollo, N. V., Lohrmann, A., Garrett, D. J., Nayagam, D. A. X., Karle, T. J., Stacey, A. D., Abberton, K. M., Morrison, W. A., et al. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.10.022 · Cited by 33
Implantation and testing of subretinal film electrodes in domestic pigs
Schanze, T., Sachs, H. G., Wiesenack, C., Brunner, U., & Sailer, H. (2005) · Experimental Eye Research · doi:10.1016/j.exer.2005.07.007 · Cited by 33
Self-citationMicroassembly and micropackaging of implantable systems
Schüettler, M., & Stieglitz, T. (2013) · Elsevier eBooks · doi:10.1533/9780857096289.1.108 · Cited by 39
Ceyssens, F., Carmona, M. B., Kil, D., Deprez, M., Tooten, E., Nuttin, B., Takeoka, A., Balschun, D., Kraft, M. D., & Puers, R. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.12.030 · Cited by 31
Optical energy transfer for intraocular microsystems studied in rabbits
Laube, T., Brockmann, C., Buß, R., Lau, C., Höck, K., Stawski, N., Stieglitz, T., Richter, H. A., & Schilling, H. (2004) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-004-0909-8 · Cited by 28
“Other insulating materials that are used in subretinal devices for a visual prosthesis are silicon nitrate [10] (which should, correctly, be referred to as silicon nitride) and a silicon oxide passivation layer [5].”
BackgroundCaldwell, R., Sharma, R., Takmakov, P. A., Street, M. G., Solzbacher, F., Tathireddy, P., & Rieth, L. W. (2017) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2017.10.002 · Cited by 30
Kunushpayeva, Z., Rapikov, A., Akhmetova, A., Sultangaziyev, A., Dossym, D., & Bukasov, R. (2020) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2020.100355 · Cited by 27
Tiwari, A., Talwekar, R. H., & Verma, M. L. (2021) · Journal of Electronic Materials · doi:10.1007/s11664-021-08814-x · Cited by 26
An active microphotodiode array of oscillating pixels for retinal stimulation
Ziegler, D., Linderholm, P., Mazza, M., Ferazzutti, S., Bertrand, D., Ionescu, A. M., & Renaud, P. (2003) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2003.09.040 · Cited by 31
“Several materials [20–22] have been evaluated in vitro and in vivo, and several production techniques have been tried, such as thin film poly-silicon [23], back-side etching of silicon [24] and spin coated polymers [25], but it remains an open question what materials should be used for the casing as well as the electr…”
BackgroundZhu, M., Jiang, Z., & Jing, W. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2005.02.036 · Cited by 25
Uji, A., Matsuo, T., Uchida, T., Shimamura, K., & Ohtsuki, H. (2006) · Artificial Organs · doi:10.1111/j.1525-1594.2006.00286.x · Cited by 24
A new fabrication method of low stress PECVD SiNx layers for biomedical applications
Wei, J., Ong, P. L., Tay, F. E. H., & Iliescu, C. (2007) · Thin Solid Films · doi:10.1016/j.tsf.2007.07.051 · Cited by 24
Disruptive visions: Biosurgery
Satava, R. M., & Wolf, R. K. (2003) · Surgical Endoscopy · doi:10.1007/s00464-003-8168-z · Cited by 23
“However there are reports of implanting microchips and microarrays into the retina (artificial retina) [3] or brain (for control of robotic arms) [6] of animals.”
BackgroundFeasibility of Neural Stimulation With Floating-Light-Activated Microelectrical Stimulators
Abdo, A., & Şahin, M. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2114882 · Cited by 24
“Biostability of these photodiode arrays was tested for subretinal implants in vivo [42].”
BackgroundAdvances in Penetrating Multichannel Microelectrodes Based on the Utah Array Platform
Leber, M., Körner, J., Reiche, C. F., Yin, M., Bhandari, R., Franklin, R. K., Negi, S., & Solzbacher, F. (2019) · Advances in experimental medicine and biology · doi:10.1007/978-981-13-2050-7_1 · Cited by 24
Soft, wireless and subdermally implantable recording and neuromodulation tools
Cai, L., & Gutruf, P. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abe805 · Cited by 24
“Conversely, the motion of organs and corrosive nature of biofluids [149] affect the implanted devices and cause structural damage [166–168], material corrosion [169, 170], electrical shorting [171] and ionic contamination [166].”
Short-and long-term neural biocompatibility of heparin coated sapphire implants
Wang, A., McAllister, J. P., Finlayson, P. G., Li, J., Brabant, K., Tang, H., Black, C., Cao, T., Liang, X., Salley, S. O., et al. (2006) · Materials Science and Engineering C · doi:10.1016/j.msec.2006.05.011 · Cited by 22
Lifetime engineering of bioelectronic implants with mechanically reliable thin film encapsulations
Niemiec, M., & Kim, K. (2023) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ad0b19 · Cited by 32
“Like alumina, low-temperature CVD silicon dioxide (SiO 2 ) is highly biocompatible, but degrades significantly in vivo [222], and is therefore often used in conjunction with silicon nitride (SiN) in the form of an oxide-nitride-oxide trilayer [223].”
Advanced Technologies and the Future of Medicine and Surgery
Satava, R. M. (2008) · Yonsei Medical Journal · doi:10.3349/ymj.2008.49.6.873 · Cited by 21
“Ophthalmologists are implanting the first generation of artificial retinas into patients.(7) This implies a future where surgeons will be asked to implant more artificial "parts", to either replace or enhance human function.”
BackgroundPerspectives on: Materials Aspects for Retinal Prostheses
Scholz, C. (2007) · Journal of Bioactive and Compatible Polymers · doi:10.1177/0883911507082160 · Cited by 21
“Although, microphotodiode arrays are completely stable in phosphate buffered saline solution for at least 21 months at room temperature, they degrade rather rapidly when implanted in the subretinal space [106,113].”
Chen, Y., Tsai, C.-Y., Lee, C., & Lin, I. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.01.014 · Cited by 21
“However, silicon is soluble in human fluids over a long period of time, as a result of galvanic erosion and electrochemical reactions [10].”
BackgroundBirkholz, M., Ehwald, K. ‐., Basmer, T., Kulse, P., Reich, C., Drews, J., Genschow, D., Haak, U., Marschmeyer, S., Matthus, E., et al. (2013) · Journal of Applied Physics · doi:10.1063/1.4811351 · Cited by 22
Wang, A., Liang, X., McAllister, J. P., Li, J., Brabant, K., Black, C., Finlayson, P. G., Cao, T., Tang, H., Salley, S. O., et al. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31034 · Cited by 16
Huang, H., Huang, H.-M., Lin, M.-C., Zhang, W., Sun, Y.-S., Kai, W., & Liaw, P. K. (2014) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2014.01.098 · Cited by 19
Pd/TiN nanocomposite catalysts for selective hydrogenation of phenol and its derivatives
Li, H., Zhang, Q.-S., Pang, Z., Tian, M., Gao, P., & Wang, L. (2016) · Chinese Chemical Letters · doi:10.1016/j.cclet.2016.03.036 · Cited by 14
A comprehensive account of biomedical applications of CVD diamond coatings
Ali, M., Ali, F., Yang, B., & Abbas, A. (2021) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ac0ca2 · Cited by 13
“In order to address blindness caused by the degeneration of retina photoreceptors, prostheses consisting of Si-based micro-chips are implanted inside human eyes [79, 166].”
Ilic, E., Pardo, A., Hauert, R., Schmutz, P., & Mischler, S. (2019) · Journal of The Electrochemical Society · doi:10.1149/2.0241906jes · Cited by 12
Tien, H.-W., Lee, C., Lin, I., & Chen, Y. (2017) · Journal of Materials Chemistry B · doi:10.1039/c7tb00867h · Cited by 11
Nanobiomaterials for bionic eye
Ghaffari, M. S., Moztarzadeh, S., Rahmanian, F., Yazdanpanah, A., Ramedani, A., Mills, D. K., & Mozafari, M. (2016) · Elsevier eBooks · doi:10.1016/b978-0-323-41532-3.00008-7 · Cited by 17
Yang, K., Nguyen, A. K., Goering, P. L., Sumant, A. V., & Narayan, R. J. (2018) · Interface Focus · doi:10.1098/rsfs.2017.0063 · Cited by 11
Material–tissue interfaces in implantable systems
Stieglitz, T., & Schüettler, M. (2013) · Elsevier eBooks · doi:10.1533/9780857096289.1.39 · Cited by 12
Transient photoresponse of nitrogen-doped ultrananocrystalline diamond electrodes in saline solution
Ahnood, A., Simonov, A. N., Laird, J. S., Maturana, M. I., Ganesan, K., Stacey, A. D., Ibbotson, M. R., Spiccia, L., & Prawer, S. (2016) · Applied Physics Letters · doi:10.1063/1.4942976 · Cited by 11
Nanbakhsh, K., Gompel, M. V., Ritasalo, R., Gollhardt, A., Horváth, D., Tóth, K., Meszéna, D., Ulbert, I., Serdijn, W. A., & Giagka, V. (2025) · Small · doi:10.1002/smll.202410141 · Cited by 11
Minimally Invasive & Long‐lasting Neural Probes from a Materials Perspective
Veronica, A., Li, Y., & Hsing, I. (2019) · Electroanalysis · doi:10.1002/elan.201800719 · Cited by 12
Towards optical neuromodulation using nitrogen-doped ultrananocrystalline diamond photoelectrodes
Falahatdoost, S., Chambers, A., Stacey, A. D., Prawer, S., & Ahnood, A. (2022) · Surfaces and Interfaces · doi:10.1016/j.surfin.2022.101850 · Cited by 9
“Nevertheless, such devices have as yet limited spatial resolution, while questions remain about the biocompatibility and stability of silicon in solution [21,22].”
BackgroundWu, Y., Zhang, Q., Wang, H., & Wang, M. (2020) · Materials Chemistry Frontiers · doi:10.1039/d0qm00279h · Cited by 9
Unprotected sidewalls of implantable silicon-based neural probes and conformal coating as a solution
Ghelich, P., Nolta, N. F., & Han, M. (2021) · npj Materials Degradation · doi:10.1038/s41529-021-00154-9 · Cited by 9
Verma, N. K., Srivastava, S., Verma, M. L., & Tiwari, A. (2022) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2022.126945 · Cited by 8
Fluid Temperature Measurement in Aqueous Solution via Electrochemical Impedance
Baldwin, A., Yoon, E. J., Hudson, T. Q., & Meng, E. F. (2019) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2019.2939811 · Cited by 8
“However, semiconductors corrode and disintegrate during chronic soaking in aqueous solutions [14]–[16].”
BackgroundContinuously Operating Biosensor and Its Integration into a Hermetically Sealed Medical Implant
Birkholz, M., Glogener, P., Glös, F., Basmer, T., & Theuer, L. (2016) · Micromachines · doi:10.3390/mi7100183 · Cited by 10
“Sensor chips are being prepared by IHP’s proprietary 0.25-µm SGB25V technology [24] on 200-mm CZ-Si wafers and subsequently have to be thinned to 15 µm and chemically etched in order to release the TiN-made MEMS b ams from th surrounding isolating dielectric [25].”
BackgroundInfluential
Metadata
- Authors
- Hämmerle, H., Kobuch, K., Kohler, K., Nisch, W., Sachs, H., & Stelzle, M.
- Affiliations
- Natural and Medical Sciences Institute (DE)
- University Hospital Regensburg (DE)
- Corresponding author
- Stelzle, Martin
- ORCID
- Stelzle, Martin
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2002-02
- Volume
- 23
- Issue
- 3
- Pages
- 797-804
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2050430198
- Cited by
- 146
- References
- 15
- Citations by year
- 2025: 2 · 2024: 2 · 2023: 4 · 2022: 3 · 2021: 8 · 2020: 4 · 2019: 10 · 2018: 10 · 2017: 8 · 2016: 11 · 2015: 4 · 2014: 7 · 2013: 8 · 2012: 8
- FWCI
- 2.56
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- University of Regensburg Publication Server (University of Regensburg) (acceptedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
- Physical Sciences › Engineering › Electrical and Electronic Engineering › CCD and CMOS Imaging Sensors
- Keywords
- subretinal implant, biostability, titanium nitride electrodes, retinal prosthesis, implant encapsulation, saline immersion
- MeSH terms
- Animals, Electrodes, Implanted, Humans, Retina, Swine, Swine, Miniature, Vitreous Body, Eye Enucleation, Prostheses and Implants, Photoreceptor Cells, Vertebrate
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.