Effect of porosity on the osteointegration and bone ingrowth of a weight-bearing nickel–titanium bone graft substitute
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Morbidity at Bone Graft Donor Sites
Younger, E. M., & Chapman, M. W. (1989) · Journal of Orthopaedic Trauma · doi:10.1097/00005131-198909000-00002 · Cited by 2,012
Bone graft materials. An overview of the basic science.
Bauer, T. W., & Muschler, G. F. (2000) · PubMed · Cited by 1,073
Potential of ceramic materials as permanently implantable skeletal prostheses
Hulbert, S. F., Young, F. A., Mathews, R. S., Klawitter, J. J., Talbert, C. D., & Stelling, F. H. (1970) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820040309 · Cited by 1,019
Bone Graft Materials: An Overview of the Basic Science
Bauer, T. W., & Muschler, G. F. (2000) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200002000-00003 · Cited by 998
Donor-Site Morbidity after Harvesting Rib and Iliac Bone
Laurie, S. W. S., Kaban, L. B., Mulliken, J. B., & Murray, J. E. (1984) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-198406000-00014 · Cited by 647
Osteoconduction at porous hydroxyapatite with various pore configurations
Chang, B.-S., Lee, >. K. >.-K., Hong, K.-S., Youn, H.-J., Ryu, H.-S., Chung, S.-S., & Park, K.-W. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00030-2 · Cited by 635
Pore diameter of more than 100 μm is not requisite for bone ingrowth in rabbits
Itälä, A. I., Ylänen, H. O., Ekholm, C., Karlsson, K. H., & Aro, H. T. (2001) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1069 · Cited by 379
Cytotoxic, allergic and genotoxic activity of a nickel-titanium alloy
Wever, D. J., Veldhuizen, A. G., Sanders, M. M., Schakenraad, J. M., & van Horn, J. R. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00041-0 · Cited by 373
SUBSTITUTES FOR AUTOLOGOUS BONE GRAFT IN ORTHOPAEDIC TRAUMA
Keating, J. F., & McQueen, M. M. (2001) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.83b1.0830003 · Cited by 273
Growth of bone marrow cells on porous ceramics in vitro
Uchida, A., Nade, S., McCartney, E., & Ching, W. (1987) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820210106 · Cited by 233
Cited by
Porosity of 3D biomaterial scaffolds and osteogenesis
Karageorgiou, V., & Kaplan, D. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.02.002 · Cited by 6,622
New Developments of Ti-Based Alloys for Biomedical Applications
Li, Y., Yang, C., Zhao, H., Qu, S., Li, X., & Li, Y. (2014) · Materials · doi:10.3390/ma7031709 · Cited by 1,048
Porous NiTi for bone implants: A review
Bansiddhi, A., Sargeant, T. D., Stupp, S. I., & Dunand, D. C. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.02.009 · Cited by 572
Metallic Scaffolds for Bone Regeneration
Alvarez, K., & Nakajima, H. (2009) · Materials · doi:10.3390/ma2030790 · Cited by 505
Role of pore size and morphology in musculo-skeletal tissue regeneration
Perez, R. A., & Mestres, G. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.12.087 · Cited by 468
Hannink, G., & Arts, J. J. C. (2011) · Injury · doi:10.1016/j.injury.2011.06.008 · Cited by 444
Mechanical behavior of regular open-cell porous biomaterials made of diamond lattice unit cells
Ahmadi, S. M., Campoli, G., Amin Yavari, S., Sajadi, B., Wauthle, R., Schrooten, J., Weinans, H., & Zadpoor, A. A. (2014) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2014.02.003 · Cited by 442
Assessing the biocompatibility of NiTi shape memory alloys used for medical applications
Es-Souni, M., Es-Souni, M., & Fischer-Brandies, H. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2888-3 · Cited by 403
Bone ingrowth in porous titanium implants produced by 3D fiber deposition
Li, J. P., Habibovic, P., van den Doel, M., Wilson, C. E., de Wijn, J. R., van Blitterswijk, C. A., & de Groot, K. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.02.020 · Cited by 393
Ataee, A., Li, Y., Brandt, M., & Wen, C. (2018) · Acta Materialia · doi:10.1016/j.actamat.2018.08.005 · Cited by 383
Kasten, P., Beyen, I., Niemeyer, P., Luginbühl, R., Bohner, M., & Richter, W. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.05.017 · Cited by 336
Iron–manganese: new class of metallic degradable biomaterials prepared by powder metallurgy
Hermawan, H., Alamdari, H., Mantovani, D., & Dubé, D. (2008) · Powder Metallurgy · doi:10.1179/174329008x284868 · Cited by 287
Li, G., Wang, L., Pan, W., Yang, F., Jiang, W., Wu, X., Kong, X., Dai, K., & Hao, Y. (2016) · Scientific Reports · doi:10.1038/srep34072 · Cited by 251
Singh, N., Hameed, P., Ummethala, R., Manivasagam, G., Prashanth, K. G., & Eckert, J. (2020) · Materials Today Advances · doi:10.1016/j.mtadv.2020.100097 · Cited by 229
Kumar, A., Mandal, S., Barui, S., Vasireddi, R., Gbureck, U., Gelinsky, M., & Basu, B. (2016) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2016.01.001 · Cited by 225
Chang, B., Song, W., Han, T., Yan, J., Li, F., Zhao, L., Kou, H., & Zhang, Y. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.01.022 · Cited by 208
Chuenjitkuntaworn, B., Inrung, W., Damrongsri, D., Mekaapiruk, K., Supaphol, P., & Pavasant, P. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32657 · Cited by 197
Metals for bone implants: safety, design, and efficacy
Shayesteh Moghaddam, N., Taheri Andani, M., Amerinatanzi, A., Haberland, C., Huff, S., Miller, M., Elahinia, M., & Dean, D. (2016) · Biomanufacturing Reviews · doi:10.1007/s40898-016-0001-2 · Cited by 184
“Table 1 Characteristics of porous NiTi and mean bone contact/integration after implantation in the distal metaphysis of a rat femur for 30 weeks [21]”
BackgroundMethodInfluentialWu, S., Li, Y., Zhang, Y., Li, X., Yuan, C., Hao, Y., Zhang, Z., & Guo, Z. (2013) · Artificial Organs · doi:10.1111/aor.12153 · Cited by 181
Dawson, J. I., & Oreffo, R. O. C. (2008) · Archives of Biochemistry and Biophysics · doi:10.1016/j.abb.2008.03.024 · Cited by 177
Chen, B., Lin, T., Yang, X., Li, Y., Xie, D., Zheng, W., Cui, H., Deng, W., & Tan, X. (2016) · International Journal of Molecular Medicine · doi:10.3892/ijmm.2016.2757 · Cited by 42
“Various approaches have been investigated to promote implant osseointegration, including modification of the implant surface and implant material (1,2), as well as the administration of medicines (3,4) and local growth factors (5).”
Metadata
- Authors
- Kujala, S., Ryhänen, J., Danilov, A., & Tuukkanen, J.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2003-11
- Volume
- 24
- Issue
- 25
- Pages
- 4691-4697
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2078724253
- Cited by
- 284
- References
- 21
- FWCI
- 5.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.