Optical coherence tomography of the human skin
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
BACKGROUND Optical coherence tomography (OCT) is a new diagnostic method for tissue characterization. OBJECTIVE We investigated normal and pathologic structures in human skin in several locations to evaluate the potential application of this technique to dermatology. METHODS Based on the principle of low-coherence interferometry, cross-sectional images of the human skin can be obtained in vivo with a high spatial resolution of about 15 microns. Within a penetration depth of 0.5 to 1.5 mm, structures of the stratum corneum, the living epidermis, and the papillary dermis can be distinguished. RESULTS Different layers could be detected that were differentiated by induction of experimental blisters and by comparison with corresponding histologic sections. Furthermore, OCT images of several skin diseases and tumors were obtained. CONCLUSION OCT is a promising new imaging method for visualization of morphologic changes of superficial layers of the human skin. It may be useful for noninvasive diagnosis of bullous skin diseases, skin tumors, and in vivo investigation of pharmacologic effects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Optical Coherence Tomography of the Human Retina
Hee, M. R. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100030081025 · Cited by 1,634
Micrometer-Scale Resolution Imaging of the Anterior Eye In Vivo With Optical Coherence Tomography
Izatt, J. A. (1994) · Archives of Ophthalmology · doi:10.1001/archopht.1994.01090240090031 · Cited by 927
Optical biopsy and imaging using optical coherence tomography
Fujimoto, J. G., Brezinski, M. E., Tearney, G. J., Boppart, S. A., Bouma, B., Hee, M. R., Southern, J. F., & Swanson, E. A. (1995) · Nature Medicine · doi:10.1038/nm0995-970 · Cited by 887
Tearney, G. J., Brezinski, M. E., Bouma, B. E., Hee, M. R., Southern, J. F., & Fujimoto, J. G. (1995) · Optics Letters · doi:10.1364/ol.20.002258 · Cited by 562
Measurement of optical properties of biological tissues by low-coherence reflectometry
Schmitt, J. M., Knüttel, A., & Bonner, R. F. (1993) · Applied Optics · doi:10.1364/ao.32.006032 · Cited by 355
Subsurface Imaging of Living Skin with Optical Coherence Microscopy
Schmitt, J. M., Yadlowsky, M. J., & Bonner, R. F. (1995) · Dermatology · doi:10.1159/000246523 · Cited by 251
Optical Coherence Tomography of Central Serous Chorioretinopathy
HEE, M. R., PULIAFITO, C. A., WONG, C., REICHEL, E., DUKER, J. S., SCHUMAN, J. S., SWANSON, E. A., & FUJIMOTO, J. G. (1995) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)73760-2 · Cited by 205
Optical coherence tomography of central serous chorioretinopathy
Ju-fen, H. (2010) · Cited by 183
Low-coherence optical tomography in turbid tissue: theoretical analysis
Pan, Y., Birngruber, R., Rosperich, J., & Engelhardt, R. (1995) · Applied Optics · doi:10.1364/ao.34.006564 · Cited by 149
Self-citationHoffmann, K. K. P., & Happe, M. R. (1997) · PubMed · Cited by 137
Cited by
Optical coherence tomography: a review of clinical development from bench to bedside
Zysk, A. M., Nguyen, F. T., Oldenburg, A. L., Marks, D. L., & Boppart, S. A. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2793736 · Cited by 547
Optical coherence tomography based angiography [Invited]
Chen, C.-L., & Wang, R. K. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.001056 · Cited by 415
Ultrahigh-resolution full-field optical coherence tomography
Dubois, A., Grieve, K., Moneron, G., Lecaque, R., Vabre, L., & Boccara, C. (2004) · Applied Optics · doi:10.1364/ao.43.002874 · Cited by 394
Lasers in dermatology: Four decades of progress
Tanzi, E. L., Lupton, J. R., & Alster, T. S. (2003) · Journal of the American Academy of Dermatology · doi:10.1067/mjd.2003.582 · Cited by 350
Finger pad friction and its role in grip and touch
Adams, M. J., Johnson, S. A., Lefèvre, P., Lévesque, V., Hayward, V., André, T., & Thonnard, J.-L. (2013) · Journal of The Royal Society Interface · doi:10.1098/rsif.2012.0467 · Cited by 293
Metadata
- Authors
- Welzel, J., Lankenau, E., Birngruber, R., & Engelhardt, R.
- Venue
- Journal of the American Academy of Dermatology
- Publisher
- Elsevier BV
- Published
- 1997-12
- Volume
- 37
- Issue
- 6
- Pages
- 958-963
- ISSN
- 0190-9622 (ISSN-L)
- OpenAlex
- W2089018977
- Cited by
- 442
- References
- 11
- FWCI
- 6.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.