CoChat

Channel interactions with high-rate biphasic electrical stimulation in cochlear implant subjects

Open access
de Balthasar, C., Boëx, C., Cosendai, G., Valentini, G., Sigrist, A., Pelizzone, M. · 2003 · Hearing Research
Cited by 74

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Channel interactions were assessed using high-rate stimulation in cochlear implant subjects using the Ineraid electrode array. Stimulation currents were applied on one intracochlear electrode and their effects on psychophysical detection thresholds on an adjacent electrode were measured. Stimuli were trains of brief, biphasic, 50-micros/phase pulses presented at a rate of 2000 pulses per second per channel. In experiment I, we studied how the detection of a probe signal was influenced by a sub-threshold perturbation signal presented either simultaneously or non-simultaneously (with no overlap) on an adjacent electrode. Results showed that simultaneous activation led to strong channel interactions, producing threshold changes consistent with instantaneous electric field summation. Non-simultaneous activation revealed much weaker interactions, producing threshold changes of opposite sign. In experiment II, we studied how the temporal delay between perturbation and probe pulses, as well as how the level of the perturbation signal influenced non-simultaneous channel interactions. First, threshold changes when reversing the polarity of the perturbation did progressively vanish when increasing the delay between pulses. This suggested that non-overlapping stimulation of adjacent electrodes produced channel interactions that were in part due to residual polarization of the nerve membrane. Second, increasing the perturbation to supra-threshold levels produced threshold elevations that were independent of the interpulse interval. This suggested channel interactions due to neural masking. These results provide insights into the different concurrently active mechanisms of channel interactions in cochlear implant systems using this type of stimuli.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0378-5955(03)00174-6

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 74

Metadata

Authors
de Balthasar, C., Boëx, C., Cosendai, G., Valentini, G., Sigrist, A., & Pelizzone, M.
Venue
Hearing Research
Publisher
Elsevier BV
Published
2003-08
Volume
182
Issue
1-2
Pages
77-87
ISSN
0378-5955 (ISSN-L)
OpenAlex
W2032857329
Cited by
74
References
1
FWCI
1.78
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Channel interactions with high-rate biphasic electrical stimulation in cochlear implant subjects. https://app.cochat.ai/papers/10.1016/s0378-5955(03)00174-6
The paper
de Balthasar, C., Boëx, C., Cosendai, G., Valentini, G., Sigrist, A., & Pelizzone, M. (2003). Channel interactions with high-rate biphasic electrical stimulation in cochlear implant subjects. Hearing Research. https://doi.org/10.1016/s0378-5955(03)00174-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.