OBJECTIVES The goal of this study was to compare T-wave alternans (TWA), signal-averaged electrocardiography (SAECG) and programmed ventricular stimulation (EPS) for arrhythmia risk stratification in patients undergoing electrophysiology study. BACKGROUND Accurate identification of patients at increased risk for sustained ventricular arrhythmias is critical to prevent sudden cardiac death. T-wave alternans is a heart rate dependent measure of repolarization that correlates with arrhythmia vulnerability in animal and human studies. Signal-averaged electrocardiography and EPS are more established tests used for risk stratification. METHODS This was a prospective, multicenter trial of 313 patients in sinus rhythm who were undergoing electrophysiologic study. T-wave alternans, assessed with bicycle ergometry, and SAECG were measured before EPS. The primary end point was sudden cardiac death, sustained ventricular tachycardia, ventricular fibrillation or appropriate implantable defibrillator (ICD) therapy, and the secondary end point was any of these arrhythmias or all-cause mortality. RESULTS Kaplan-Meier survival analysis of the primary end point showed that TWA predicted events with a relative risk of 10.9, EPS had a relative risk of 7.1 and SAECG had a relative risk of 4.5. The relative risks for the secondary end point were 13.9, 4.7 and 3.3, respectively (p < 0.05). Multivariate analysis of 11 clinical parameters identified only TWA and EPS as independent predictors of events. In the prespecified subgroup with known or suspected ventricular arrhythmias, TWA predicted primary end points with a relative risk of 6.1 and secondary end points with a relative risk of 8.0. CONCLUSIONS T-wave alternans is a strong independent predictor of spontaneous ventricular arrhythmias or death. It performed as well as programmed stimulation and better than SAECG in risk stratifying patients for life-threatening arrhythmias.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
Self-citationThe Cardiac Arrhythmia Suppression Trial (CAST) Investigators (1989) · New England Journal of Medicine · doi:10.1056/nejm198908103210629 · Cited by 3,300
A Randomized Study of the Prevention of Sudden Death in Patients with Coronary Artery Disease
Buxton, A. E., Lee, K. L., Fisher, J. D., Josephson, M. E., Prystowsky, E. N., & Hafley, G. (1999) · New England Journal of Medicine · doi:10.1056/nejm199912163412503 · Cited by 2,489 · cited 1×
“Recently, programmed ventricular stimulation during electrophysiology (EPS) testing (6,7), but not signal averaged electrocardiography (SAECG) (8), identified a cohort with left ventricular dysfunction who had improved survival with implantable cardioverter-defibrillator (ICD) placement.”
BackgroundWaldo, A. L., Camm, A. J., deRuyter, H., Friedman, P. L., MacNeil, D. J., Pauls, J. F., Pitt, B., Pratt, C. M., Schwartz, P. J., & Veltri, E. P. (1996) · The Lancet · doi:10.1016/s0140-6736(96)02149-6 · Cited by 1,371
Bigger, J. T., Fleiss, J. L., Kleiger, R., Miller, J. P., & Rolnitzky, L. M. (1984) · Circulation · doi:10.1161/01.cir.69.2.250 · Cited by 1,286
Electrical Alternans and Vulnerability to Ventricular Arrhythmias
Rosenbaum, D. S., Jackson, L. E., Smith, J. M., Garan, H., Ruskin, J. N., & Cohen, R. J. (1994) · New England Journal of Medicine · doi:10.1056/nejm199401273300402 · Cited by 1,143
Self-citationJulian, D., Camm, A., Frangin, G., Janse, M., Munoz, A., Schwartz, P., & Simon, P. (1997) · The Lancet · doi:10.1016/s0140-6736(96)09145-3 · Cited by 1,112
Simson, M. B. (1981) · Circulation · doi:10.1161/01.cir.64.2.235 · Cited by 1,107
Bigger, J. T. (1997) · New England Journal of Medicine · doi:10.1056/nejm199711273372201 · Cited by 1,020
Cairns, J. A., Connolly, S. J., Roberts, R., & Gent, M. (1997) · The Lancet · doi:10.1016/s0140-6736(96)08171-8 · Cited by 957
Cited by
Goldberger, J. J., Cain, M. E., Hohnloser, S. H., Kadish, A. H., Knight, B. P., Lauer, M. S., Maron, B. J., Page, R. L., Passman, R. S., Siscovick, D., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.189375 · Cited by 1,450
Guidelines on Management (diagnosis and treatment) of syncope ? update 2004
(2004) · Europace · doi:10.1016/j.eupc.2004.08.008 · Cited by 652
Goldberger, J. J., Cain, M. E., Hohnloser, S. H., Kadish, A. H., Knight, B. P., Lauer, M. S., Maron, B. J., Page, R. L., Passman, R. S., Siscovick, D., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.05.003 · Cited by 428
Verrier (2011) · doi:10.1016/j.jacc.2011.06.029 · Cited by 421
“An alternative explanation implicates withholding beta-adrenergic blocking agents to explain the inconsistent results (Fig.”
T-Wave Alternans and the Susceptibility to Ventricular Arrhythmias
Narayan, S. M. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.08.066 · Cited by 357
Noninvasive Risk Assessment Early After a Myocardial Infarction
Exner, D. V., Kavanagh, K. M., Slawnych, M. P., Mitchell, L. B., Ramadan, D., Aggarwal, S. G., Noullett, C., Van Schaik, A., Mitchell, R. T., Shibata, M. A., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.08.042 · Cited by 348
Nearing, B. D., & Verrier, R. L. (2002) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00592.2001 · Cited by 347
Bloomfield, D. M., Steinman, R. C., Namerow, P. B., Parides, M., Davidenko, J., Kaufman, E. S., Shinn, T., Curtis, A., Fontaine, J., Holmes, D., et al. (2004) · Circulation · doi:10.1161/01.cir.0000143160.14610.53 · Cited by 341
Self-citationImplantable Cardioverter-Defibrillators: Expanding Indications and Technologies
Goldberger, Z., & Lampert, R. (2006) · JAMA · doi:10.1001/jama.295.7.809 · Cited by 271
Bloomfield, D. M., Bigger, J. T., Steinman, R. C., Namerow, P. B., Parides, M. K., Curtis, A. B., Kaufman, E. S., Davidenko, J. M., Shinn, T. S., & Fontaine, J. M. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.11.026 · Cited by 271
Self-citationMicrovolt T-Wave Alternans for the Risk Stratification of Ventricular Tachyarrhythmic Events
Gehi, A. K., Stein, R. H., Metz, L. D., & Gomes, J. A. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.059 · Cited by 252
Haigney, M. C., Zareba, W., Gentlesk, P. J., Goldstein, R. E., Illovsky, M., McNitt, S., Andrews, M. L., & Moss, A. J. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.06.063 · Cited by 237
T-wave alternans as a predictor for sudden cardiac death after myocardial infarction
Ikeda, T., Saito, H., Tanno, K., Shimizu, H., Watanabe, J., Ohnishi, Y., Kasamaki, Y., & Ozawa, Y. (2002) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)02171-3 · Cited by 225
ACC/AHA Guidelines for the Management of Patients With ST-Elevation Myocardial Infarction
(2004) · Circulation · doi:10.1161/circ.110.9.e82 · Cited by 215
Ikeda, T., Yoshino, H., Sugi, K., Tanno, K., Shimizu, H., Watanabe, J., Kasamaki, Y., Yoshida, A., & Kato, T. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.06.075 · Cited by 212
Methodological Principles of T Wave Alternans Analysis: A Unified Framework
Martinez, J. P., & Olmos, S. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.844025 · Cited by 208
Effectiveness of implantable defibrillators for preventing arrhythmic events and death
Lee, D. S., Green, L. D., Liu, P. P., Dorian, P., Newman, D. M., Grant, F. C., Tu, J. V., & Alter, D. A. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00253-5 · Cited by 195
Gold, M. R., Ip, J. H., Costantini, O., Poole, J. E., McNulty, S., Mark, D. B., Lee, K. L., & Bardy, G. H. (2008) · Circulation · doi:10.1161/circulationaha.107.748962 · Cited by 193
Self-citationVerrier, R. L., Nearing, B. D., Rovere, M. T. L., Pinna, G. D., Mittleman, M. A., Bigger, J. T., Schwartz, P. J., & ATRAMI Investigators (2003) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2003.03118.x · Cited by 177
Dagres, N., & Hindricks, G. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht109 · Cited by 169
Risk of Ventricular Arrhythmia After Implantable Defibrillator Treatment in Anxious Type D Patients
van den Broek, K. C., Nyklíček, I., van der Voort, P. H., Alings, M., Meijer, A., & Denollet, J. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.04.043 · Cited by 110
Metadata
- Authors
- Gold, M. R., Bloomfield, D. M., Anderson, K. P., El-Sherif, N. E., Wilber, D. J., Groh, W. J., Estes, N. A. M., Kaufman, E. S., Greenberg, M. L., & Rosenbaum, D. S.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2000-12
- Volume
- 36
- Issue
- 7
- Pages
- 2247-2253
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2065246793
- Cited by
- 275
- References
- 23
- FWCI
- 13.16
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.