Periprocedural quantitative coronary angiography after Palmaz-Schatz stent implantation predicts the restenosis rate at six months
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
OBJECTIVES We aimed to identify periprocedural quantitative coronary angiographic (QCA) variables that have predictive value on long-term angiographic results and to construct multivariate models using these variables for postprocedural prognosis. BACKGROUND Coronary stent implantation has reduced the restenosis rate significantly as compared with balloon angioplasty in short de novo lesions in coronary arteries >3 mm in size. Although the postprocedural minimal luminal diameter (MLD) is known to have significant bearing on long-term angiographic results, no practically useful model exists for prediction of angiographic outcome based on the periprocedural QCA variables. METHODS The QCA data from patients who underwent Palmaz-Schatz stent implantation for short (<15 mm) de novo lesions in coronary arteries >3 mm and completed six months of angiographic follow-up in the four prospective clinical trials (BENESTENT I, BENESTENT II pilot, BENESTENT II and MUSIC) were pooled. Multiple models were constructed using multivariate analysis. The Hosmer-Lemeshow goodness-of-fit test was used to identify the model of best fit, and this model was used to construct a reference chart for prediction of angiographic outcome on the basis of periprocedural QCA variables. RESULTS Univariate analysis performed using QCA variables revealed that vessel size, MLD before and after the procedure, reference area before and after the procedure, minimal luminal cross-sectional area before and after the procedure, diameter stenosis after the procedure, area of plaque after the procedure and area stenosis after the procedure were significant predictors of angiographic outcome. Using multivariate analysis, the Hosmer-Lemeshow goodness-of-fit test showed that the model containing percent diameter stenosis after the procedure and vessel size best fit the data. A reference chart was then developed to calculate the expected restenosis rate. CONCLUSIONS Restenosis rate after stent implantation for short lesions can be predicted using the variables percent diameter stenosis after the procedure and vessel size. This meta-analysis indicates that the concept of "the bigger the better" holds true for coronary stent implantation. Applicability of the model beyond short lesions should be tested.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556 · cited 1×
“Four clinical trials (BENESTENT I [5], BENESTENT II pilot [12], BENESTENT II [13,14] and MUSIC [15]) that used the P-S intracoronary stent over a period of seven years were considered for this meta-analysis.”
MethodSelf-citationFischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310802 · Cited by 4,271
Intravascular Stents to Prevent Occlusion and Re-Stenosis after Transluminal Angioplasty
Sigwart, U., Puel, J., Mirkovitch, V., Joffre, F., & Kappenberger, L. (1987) · New England Journal of Medicine · doi:10.1056/nejm198703193161201 · Cited by 1,892
DOTTER, C. T., & JUDKINS, M. P. (1964) · Circulation · doi:10.1161/01.cir.30.5.654 · Cited by 1,763
Intracoronary Stenting Without Anticoagulation Accomplished With Intravascular Ultrasound Guidance
Colombo, A., Hall, P., Nakamura, S., Almagor, Y., Maiello, L., Martini, G., Gaglione, A., Goldberg, S. L., & Tobis, J. M. (1995) · Circulation · doi:10.1161/01.cir.91.6.1676 · Cited by 1,428
Serruys, P. W., van Hout, B., Bonnier, H., Legrand, V., Garcia, E., Macaya, C., Sousa, E., van der Giessen, W., Colombo, A., Seabra-Gomes, R., et al. (1998) · The Lancet · doi:10.1016/s0140-6736(97)11128-x · Cited by 650
Self-citationEndovascular Stent Design Dictates Experimental Restenosis and Thrombosis
Rogers, C., & Edelman, E. R. (1995) · Circulation · doi:10.1161/01.cir.91.12.2995 · Cited by 543
Variability in the analysis of coronary arteriograms.
DeRouen, T. A., Murray, J. A., & Owen, W. (1977) · Circulation · doi:10.1161/01.cir.55.2.324 · Cited by 485
Serruys, P. W., Emanuelsson, H., van der Giessen, W., Lunn, A. C., Kiemeney, F., Macaya, C., Rutsch, W., Heyndrickx, G., Suryapranata, H., Legrand, V., et al. (1996) · Circulation · doi:10.1161/01.cir.93.3.412 · Cited by 408
Self-citationIntracoronary ultrasound observations during stent implantation.
Nakamura, S., Colombo, A., Gaglione, A., Almagor, Y., Goldberg, S. L., Maiello, L., Finci, L., & Tobis, J. M. (1994) · Circulation · doi:10.1161/01.cir.89.5.2026 · Cited by 394
Kuntz, R. E., Safian, R. D., Carrozza, J. P., Fishman, R. F., Mansour, M., & Baim, D. S. (1992) · Circulation · doi:10.1161/01.cir.86.6.1827 · Cited by 359
Hall, P., Nakamura, S., Maiello, L., Itoh, A., Blengino, S., Martini, G., Ferraro, M., & Colombo, A. (1996) · Circulation · doi:10.1161/01.cir.93.2.215 · Cited by 281
Predictors of Restenosis After Coronary Stent Implantation
Bauters, C., Hubert, E., Prat, A., Bougrimi, K., Van Belle, E., McFadden, E. P., Amouyel, P., Lablanche, J.-M., & Bertrand, M. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00076-x · Cited by 275
Quantitative coronary arteriography
Rafflenbeul, W., Smith, L. R., Rogers, W. J., Mantle, J. A., Rackley, C. E., & Russell, R. O. (1979) · The American Journal of Cardiology · doi:10.1016/0002-9149(79)90066-3 · Cited by 239
Clinical experience with the Palmaz-Schatz coronary stent
Schatz, R. A., Goldberg, S., Leon, M. B., Baim, D. S., Hirshfeld, J. W., CLEMAN, M. W., Ellis, S. G., & Topol, E. J. (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90952-6 · Cited by 230
Haase, J., Escaned, J., van Swijndregt, E. M., Ozaki, Y., Gronenschild, E. H. B. M., Slager, C. J., & Serruys, P. W. J. C. (1993) · Catheterization and Cardiovascular Diagnosis · doi:10.1002/ccd.1810300205 · Cited by 149
Self-citationAn overview of coronary quantitation techniques as of 1989
Reiber, J. H. C. (1991) · Developments in cardiovascular medicine · doi:10.1007/978-94-011-3726-3_4 · Cited by 61
Ozaki, Y., Violaris, A. G., Kobayashi, T., Keane, D., Camenzind, E., Mario, C. D., de Feyter, P. J., Roelandt, J. R. T. C., & Serruys, P. W. J. C. (1997) · Circulation · doi:10.1161/01.cir.96.2.491 · Cited by 50
Self-citationDifferences in restenosis propensity of devices for transluminal coronary intervention
FOLEY, D. P., Melkert, R., Umans, V. A. W. M., de Jaegere, P. P. T., Strikwerda, S., de Feyter, P. J., & Serruys, P. W. J. C. (1995) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a060740 · Cited by 31
Self-citationEscaned, J., Foley, D. P., Haase, J., Mario, C. D., Hermans, W. R. M., de Feyter, P. J., & Serruys, P. W. J. C. (1993) · American Heart Journal · doi:10.1016/0002-8703(93)90530-m · Cited by 28
Self-citationDigital geometric measurements in comparison to cinefilm analysis of coronary artery dimensions
Haase, J., Nugteren, S. K., van Swijndregt, E. M., Slager, C. J., Mario, C. D., de Feyter, P. J., & Serruys, P. W. J. C. (1993) · Catheterization and Cardiovascular Diagnosis · doi:10.1002/ccd.1810280404 · Cited by 26
Self-citation
Cited by
A Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery Disease
Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O'Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032441 · Cited by 2,749
WRITING COMMITTEE MEMBERS, Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.170815 · Cited by 2,218
Stone, G. W., Ellis, S. G., Cannon, L., Mann, J. T., Greenberg, J. D., Spriggs, D., O'Shaughnessy, C. D., DeMaio, S., Hall, P., Popma, J. J., et al. (2005) · JAMA · doi:10.1001/jama.294.10.1215 · Cited by 765
Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O’Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., et al. (2004) · Circulation · doi:10.1161/01.cir.0000127110.49192.72 · Cited by 759
Smith, S. C., Dove, J. T., Jacobs, A. K., Kennedy, J. W., Kereiakes, D., Kern, M. J., Kuntz, R. E., Popma, J. J., Schaff, H. V., Williams, D. O., et al. (2001) · Circulation · doi:10.1161/01.cir.103.24.3019 · Cited by 608
Metadata
- Authors
- Serruys, P. W., Kay, I. P., Disco, C., Deshpande, N. V., & de Feyter, P. J.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 1999-10
- Volume
- 34
- Issue
- 4
- Pages
- 1067-1074
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W1485035715
- Cited by
- 170
- References
- 21
- FWCI
- 9.08
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.