Abstract
The synthesis and characterization of a new lithium octa-n-butoxy-substituted naphthalocyanine radical probe (LiNc-BuO) and its use in the determination of concentration of oxygen (oximetry) by electron paramagnetic resonance (EPR) spectroscopy are reported. The probe is synthesized as a needle-shaped microcrystalline particulate. The particulate shows a single-line EPR spectrum that is highly exchange-narrowed with a line-width of 210 mG. The EPR line-width is sensitive to molecular oxygen showing a linear relationship between the line-width and concentration of oxygen (pO(2)) with a sensitivity of 8.5 mG/mmHg. We studied a variety of physicochemical and biological properties of LiNc-BuO particulates to evaluate the suitability of the probe for in vivo oximetry. The probe is unaffected by biological oxidoreductants, stable in tissues for several months, and can be successfully internalized in cells. We used this probe to monitor changes in concentration of oxygen in the normal muscle and RIF-1 tumor tissue of mice as a function of tumor growth. The data showed a rapid decrease in the tumor pO(2) with increase of tumor volume. Human arterial smooth muscle cells, upon internalization of the LiNc-BuO probe, showed a marked oxygen gradient across the cell membrane. In summary, the newly synthesized octa-n-butoxy derivative of lithium naphthalocyanine has unique properties that are useful for determining oxygen concentration in chemical and biological systems by EPR spectroscopy and also for magnetic tagging of cells.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“One of the most important characteristics of this approach is that it does not interfere with oxygen metabolism within the biological system, therefore providing a basis for non-invasive oxygen measurements in biological systems [33], a critical requirement for measurement of oxygen within 3D models [29].”
From Direct Measurements of Oxygen Gradients in Spheroid Culture System Using Electron Parametric Resonance Oximetry (2016) · cites this paper as [33]
Citations
Cites
Wang, Y.-X. J., Hussain, S. M., & Krestin, G. P. (2001) · European Radiology · doi:10.1007/s003300100908 · Cited by 1,381
Vaupel, P. W., Schlenger, K., Knoop, C., & Höckel, M. (1991) · PubMed · Cited by 1,118
Noninvasive imaging of tumor redox status and its modification by tissue glutathione levels.
Kuppusamy, P., Li, H., Ilangovan, G., Cardounel, A. J., Zweier, J. L., Yamada, K., Krishna, M. C., & Mitchell, J. B. (2002) · PubMed · Cited by 832
Self-citationKooi, M. E., Cappendijk, V. C., Cleutjens, K. B. J. M., Kessels, A. G. H., Kitslaar, P. J. E. H. M., Borgers, M., Frederik, P. M., Daemen, M. J. A. P., & van Engelshoven, J. M. A. (2003) · Circulation · doi:10.1161/01.cir.0000068315.98705.cc · Cited by 798
Hinds, K. A., Hill, J. M., Shapiro, E. M., Laukkanen, M. O., Silva, A. C., Combs, C. A., Varney, T. R., Balaban, R. S., Koretsky, A. P., & Dunbar, C. E. (2003) · Blood · doi:10.1182/blood-2002-12-3669 · Cited by 401
Noninvasive Evaluation of Intrarenal Oxygenation With BOLD MRI
Prasad, P. V., Edelman, R. R., & Epstein, F. H. (1996) · Circulation · doi:10.1161/01.cir.94.12.3271 · Cited by 399
Bonnemain, B. (1998) · Journal of Drug Targeting · doi:10.3109/10611869808997890 · Cited by 371
Liu, K. J., Gast, P., Moussavi, M., Norby, S. W., Vahidi, N., Walczak, T., Wu, M., & Swartz, H. M. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.12.5438 · Cited by 318
Krishna, M. C., English, S., Yamada, K., Yoo, J., Murugesan, R., Devasahayam, N., Cook, J. A., Golman, K., Ardenkjaer-Larsen, J. H., Subramanian, S., et al. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.042671399 · Cited by 304
A new series of molecular semiconductors: phthalocyanine radicals
Turek, P., Petit, P., Andre, J. J., Simon, J., Even, R., Boudjema, B., Guillaud, G., & Maitrot, M. (1987) · Journal of the American Chemical Society · doi:10.1021/ja00251a012 · Cited by 262
Cited by
Items 101–149 of 149
Optimization of magnetic field sweep and field modulation amplitude for continuous-wave EPR oximetry
Palmer, J., Potter, L. C., & Ahmad, R. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.01.013 · Cited by 11
“A small single crystal of LiNc-BuO [13], under anoxic Palmer et al.”
BackgroundInfluentialA molecular paramagnetic spin-doped biopolymeric oxygen sensor
Meenakshisundaram, G., Eteshola, E., Blank, A., Lee, S. C., & Kuppusamy, P. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.03.011 · Cited by 13
“The technique has been used for several in vitro studies to monitor intracellular and extracellular oxygen levels, cellular respiration, as well, as oxygen consumption (Kutala et al., 2004; Pandian et al., 2005, 2003a; Presley et al., 2006).”
BackgroundMethodSelf-citationFrank, J., Gündel, D., Drescher, S., Thews, O., & Mäder, K. (2015) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2015.10.401 · Cited by 11
Decroos, C., Balland, V., Boucher, J., Bertho, G., Li, Y., & Mansuy, D. (2013) · Chemical Research in Toxicology · doi:10.1021/tx400250a · Cited by 11
Magnetic Force Microscopy of an Oxygen‐Sensing Spin‐Probe
Savla, M., Pandian, R. P., Kuppusamy, P., & Agarwal, G. (2008) · Israel Journal of Chemistry · doi:10.1560/ijc.48.1.33 · Cited by 11
Self-citationPandian, R. P., Meenakshisundaram, G., Bratasz, A., Eteshola, E., Lee, S. C., & Kuppusamy, P. (2010) · Biomedical Microdevices · doi:10.1007/s10544-009-9394-5 · Cited by 12
“…(LiPc), lithium octa-nbutoxy-naphthalocyanine (LiNc-BuO), or lithium 1,8,15,22-tetraphenoxyphthalocyanine (LiPc-α-OPh) crystals, possess EPR linewidths that are highly sensitive to the local oxygen concentration (Ilangovan et al. 2004; Pandian et al. 2007; Pandian et al. 2006; Pandian et al. 2003).”
BackgroundSelf-citationEpel, B., Kotecha, M., & Halpern, H. J. (2017) · Wiley eBooks · doi:10.1002/9781119193272.ch7 · Cited by 13
Supplemental Oxygen Protects Heart Against Acute Myocardial Infarction
Prabhat, A. M., Kuppusamy, M. L., Naidu, S. K., Meduru, S., Reddy, P. T., Dominic, A., Khan, M., Rivera, B. K., & Kuppusamy, P. (2018) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2018.00114 · Cited by 11
“Microcrystals of LiNc-BuO were synthesized as previously reported (15).”
MethodSelf-citationKmieć, M. M., Hebert, K. A., Tse, D., Hodge, S., Williams, B. B., Schaner, P. E., & Kuppusamy, P. (2021) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29039 · Cited by 10
Self-citationHou, H. G., Khan, N. I., & Kuppusamy, P. (2017) · Advances in experimental medicine and biology · doi:10.1007/978-3-319-55231-6_41 · Cited by 10
Self-citationTseytlin, M., Stolin, A., Guggilapu, P., Bobko, A. A., Khramtsov, V. V., Tseytlin, O., & Raylman, R. R. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aabfa1 · Cited by 10
“The gradients were calibrated by imaging of point-like particles of lithium octa-nbutoxynaphthalocyanine (LiNC-Buo), which produce EPR signals, arrayed in a cubic grid separated by known distances along the x, y, and z axes (Pandian et al 2003).”
Monitoring Oxygenation During the Growth of A Transplanted Tumor
Bratasz, A., Pandian, R. P., Ilangovan, G., & Kuppusamy, P. (2006) · Springer eBooks · doi:10.1007/0-387-29540-2_58 · Cited by 10
Self-citationEstimation of mean and median pO2 values for a composite EPR spectrum
Ahmad, R., Vikram, D. S., Potter, L. C., & Kuppusamy, P. (2008) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2008.03.002 · Cited by 9
Self-citationMATSUMOTO, K.-I., Aoki, I., Nakanishi, I., Matsumoto, A., Nyui, M., Endo, K., & Anzai, K. (2010) · Magnetic Resonance in Medical Sciences · doi:10.2463/mrms.9.131 · Cited by 9
Amida, T., Nakaoka, R., Komarov, D. A., Yamamoto, K., Inanami, O., Matsumoto, S., & Hirata, H. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2743232 · Cited by 10
“be measured by electron paramagnetic resonance (EPR) using oxygen-sensitive free radical molecules called spin probes [4]–[7].”
Epel, B., & Halpern, H. J. (2017) · Wiley eBooks · doi:10.1002/9780470034590.emrstm1512 · Cited by 10
Characterization of a clinically used charcoal suspension for in vivo EPR oximetry
Desmet, C. M., Tran, L. B. A., Danhier, P., & Gallez, B. (2018) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-018-0704-x · Cited by 7
Oxygen-Sensing Paramagnetic Probes for Clinical Oximetry
Kmieć, M. M., Tse, D., & Kuppusamy, P. (2021) · Advances in experimental medicine and biology · doi:10.1007/978-3-030-48238-1_41 · Cited by 8
Self-citationYamamoto, K., Yasui, H., Bo, T., Yamamori, T., Hiraoka, W., Yamasaki, T., Yamada, K., & Inanami, O. (2018) · Applied Magnetic Resonance · doi:10.1007/s00723-018-1007-0 · Cited by 11
A Miniature Electron Spin Resonance Probehead for Transcutaneous Oxygen Monitoring
Wolfson, H., Ahmad, R., Twig, Y., Kuppusamy, P., & Blank, A. (2014) · Applied Magnetic Resonance · doi:10.1007/s00723-014-0593-8 · Cited by 7
Self-citationA hand-held EPR scanner for transcutaneous oximetry
Wolfson, H., Ahmad, R., Twig, Y., Blank, A., & Kuppusamy, P. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2083864 · Cited by 7
Self-citationMoldovan, N. I., Anghelina, M. I., Varadharaj, S., Butt, O. I., Wang, T., Yang, F., Moldovan, L., & Zweier, J. L. (2014) · Journal of the American Heart Association · doi:10.1161/jaha.113.000471 · Cited by 9
“The O2 response of LiPc showed good linearity from 0 to 114 mm Hg, with a sensitivity of 5.5 mGauss/mm Hg.27 The electron paramagnetic resonance (EPR) spectra of LiPc crystals were obtained with the use of home-built or commercial (Magnettech, Berlin, Germany) L-band spectrometers with a frequency of 1.1 GHz, microwav…”
Self-citationBiocompatibility of Oxygen-Sensing Paramagnetic Implants
Tse, D., & Kuppusamy, P. (2019) · Cell Biochemistry and Biophysics · doi:10.1007/s12013-019-00881-6 · Cited by 7
Self-citationHou, H. G., Baek, J. H., Zhang, H., Wood, F., Gao, Y. S., Flood, A. B., Swartz, H. M., & Buehler, P. W. (2019) · Blood transfusion · doi:10.2450/2019.0037-19 · Cited by 7
He, G., Dumitrescu, C., Petryakov, S. V., Deng, Y., Kesselring, E., & Zweier, J. L. (2007) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2007.03.020 · Cited by 7
Self-citationEvaluation of Lithium Naphthalocyanine (LiNc) Microcrystals for Biological EPR Oximetry
Pandian, R. P., Chacko, S. M., Kuppusamy, M. L., Rivera, B. K., & Kuppusamy, P. (2011) · Advances in experimental medicine and biology · doi:10.1007/978-1-4419-7756-4_5 · Cited by 7
“We have thus far made several variants of promising lithium phthalocyanine-based synthetic molecules for possible use as a suitable oximetry probe in a variety of biological applications [3-6].”
BackgroundSelf-citationSense and Sensibility of Oxygen in Pathophysiology Using EPR Oximetry
Kuppusamy, P. (2020) · Biological magnetic resonance · doi:10.1007/978-3-030-47318-1_9 · Cited by 11
Self-citationVikram, D. S., Ahmad, R., Pandian, R. P., Petryakov, S. V., & Kuppusamy, P. (2008) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2008.04.034 · Cited by 6
Self-citationPetryakov, S. V., Kmieć, M. M., O’Connell, R. C., Ubert, C. S., Kassey, V. B., Schaner, P. E., & Kuppusamy, P. (2024) · Applied Magnetic Resonance · doi:10.1007/s00723-024-01747-8 · Cited by 7
Self-citationMultisite EPR oximetry from multiple quadrature harmonics
Ahmad, R., Som, S., Johnson, D. H., Zweier, J. L., Kuppusamy, P., & Potter, L. C. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.10.016 · Cited by 5
“The phantom consisted of four capillary tubes, each carrying 50 to 80 µg of LiNc-BuO.”
MethodSelf-citationNanofiber-based paramagnetic probes for rapid, real-time biomedical oximetry
Bhallamudi, V. P., Xue, R., Purser, C. M., Presley, K. F., Banasavadi‐Siddegowda, Y., Hwang, J., Kaur, B., Hammel, P. C., Poirier, M. G., Lannutti, J. J., et al. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0063-1 · Cited by 7
Self-citationMizugaki, H., Nagane, M., Sato‐Akaba, H., Kmieć, M. M., Kuppusamy, P., Yasui, H., Inanami, O., Murakami, H., Aihara, N., Kamiie, J., et al. (2024) · FEBS Journal · doi:10.1111/febs.17379 · Cited by 4
“The OxyChip is an FDA-approved minimally invasive oxygen-sensitive probe consisting of an oxygen-sensitive paramagnetic molecule, lithium 5, 9, 14, 18, 23, 27, 32, 36- octa-n -butoxy-2,3-naphthalocyanine (LiNc-BuO), encapsulated in polydimethylsiloxane (PDMS) [50,51].”
Self-citationUniform spinning sampling gradient electron paramagnetic resonance imaging
Johnson, D. H., Ahmad, R., Liu, Y., Chen, Z., Samouilov, A., & Zweier, J. L. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24712 · Cited by 4
“The EPR probe solution used consisted of paramagnetic nanoparticles which were prepared by adding a solution of lithium octa-nbutoxynaphthalocyanine (LiNc-BuO, 20 mg) (19) and lecithin (140 mg) in THF (1 mL) into 10 mL of a fast stirred PBS, followed by removal of the organic solvent under vacuo.”
MethodSelf-citationHand‐held electron spin resonance scanner for subcutaneous oximetry using OxyChip
Almog, N., Zgadzai, O., Kuppusamy, P., Zur, Y., Baruch, L., Machluf, M., & Blank, A. (2024) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30066 · Cited by 3
Self-citation50 Years of EPR Oximetry: from Capillary to Clinic
O’Connell, R. C., Ubert, C. S., Kmieć, M. M., Petryakov, S. V., Kassey, V. B., Schaner, P. E., & Kuppusamy, P. (2024) · Applied Magnetic Resonance · doi:10.1007/s00723-024-01745-w · Cited by 6
Self-citationEnomoto, A., Qian, C., Devasahayam, N., Kishimoto, S., Oshima, N., Blackman, B. N., Swenson, R. E., Mitchell, J. B., Koretsky, A. P., & Krishna, M. C. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27185 · Cited by 3
Dual-scan acquisition for accelerated continuous-wave EPR oximetry
Palmer, J., Potter, L. C., Johnson, D. H., Zweier, J. L., & Ahmad, R. (2012) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2012.05.021 · Cited by 2
“564 G, corresponding to the range 0–30 mm Hg pO2 when using a LiNcBuO probe [19].”
MethodSelf-citationStatistical reconstruction algorithms for continuous wave electron spin resonance imaging
Kissos, I., Levit, M., Arie Feuer, B., & Blank, A. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2013.04.003 · Cited by 2
“The experimental results of a test sample with 2 crystals of lithium phthalocyanine (LiPc) and one crystal of LiNc–BuO free radicals, described in [57] (see also Section 6.2 below), were collected with uniform sampling of 256  256 [angular samples  radial samples].”
BackgroundInfluentialMeasurement of Tissue Oxygen as a Novel Approach to Optimizing Red Blood Cell Quality Assessment
Buehler, P. W., Flood, A. B., & Swartz, H. M. (2021) · Advances in experimental medicine and biology · doi:10.1007/978-3-030-48238-1_60 · Cited by 2
Kmieć, M. M., Petryakov, S. V., Kheirollah, A., Ubert, C. S., O'Connell, R. C., & Kuppusamy, P. (2026) · Magnetic Resonance in Medicine · doi:10.1002/mrm.70444 · Cited by 1
Self-citationContribution of Harold M. Swartz toIn VivoEPR and EPR Dosimetry
Gallez, B. (2016) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncw157 · Cited by 1
Oxygen-releasing manganese clay hybrid complex triggers p53-mediated cancer cell death in hypoxia
Deepa, Mittal, A., Taxak, S., Tandon, V., & Pati, U. (2020) · Biochemical Pharmacology · doi:10.1016/j.bcp.2020.114054 · Cited by 1
Multifrequency EPR Microscopy: Experimental and Theoretical Aspects
Blank, A. (2011) · doi:10.1002/9783527633531.ch19 · Cited by 1
Longitudinal oxygen imaging in 3D (bio)printed models
O’Connell, R. C. (2023) · The Research Repository @ WVU (West Virginia University) · doi:10.33915/etd.12172 · Cited by 1
Free-radical probes for functional in vivo EPR imaging
Subramanian, S., & Krishna, M. C. (2007) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.700872
Vikram, D. S. (2008) · OhioLink ETD Center (Ohio Library and Information Network)
4D EPR Oximetry Imaging for 4D Bioprinting and Tissue Engineering
Sarvari, S. (2024) · The Research Repository @ WVU (West Virginia University) · doi:10.33915/etd.12500
Lithium phthalocyanine (γ-structure) as a molecular oxygen sensor
Tomšík, E., Černochová, Z., Scheibe, M., & Tadyszak, K. (2025) · RSC Advances · doi:10.1039/d4ra08335k · Cited by 1
Challenges to Intestinal pO2 Measurement Using EPR
Fisher, E., Khan, M., Steiner, R. P., & Kuppusamy, P. (2011) · Advances in experimental medicine and biology · doi:10.1007/978-1-4419-7756-4_6
Self-citation
Metadata
- Authors
- Pandian, R. P., Parinandi, N. L., Ilangovan, G., Zweier, J. L., & Kuppusamy, P.
- Affiliations
- The Ohio State University (US)
- Corresponding author
- Kuppusamy, Periannan
- Venue
- Free Radical Biology and Medicine
- Publisher
- Elsevier BV
- Published
- 2003-11
- Volume
- 35
- Issue
- 9
- Pages
- 1138-1148
- ISSN
- 0891-5849 (ISSN-L)
- OpenAlex
- W1989313199
- Cited by
- 150
- References
- 44
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 6 · 2023: 2 · 2022: 1 · 2021: 5 · 2020: 3 · 2019: 9 · 2018: 11 · 2017: 8 · 2016: 6 · 2015: 5 · 2014: 5 · 2013: 8 · 2012: 7
- FWCI
- 4.16
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Free Radical Biology and Medicine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health
- National Cancer Institute (R01CA078886, CA78886)
- National Institute of Biomedical Imaging and Bioengineering (EB 00306, R01EB000306)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Electron Spin Resonance Studies
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Toxicology › Bioactive Compounds and Antitumor Agents
- Keywords
- oxygen sensing, oximetry, exchange narrowing, EPR linewidth, tumor hypoxia, arterial smooth muscle cells, cellular internalization
- MeSH terms
- Animals, Electron Spin Resonance Spectroscopy, Female, Fibrosarcoma, Gamma Rays, Humans, Hydrogen-Ion Concentration, Mice, Inbred C3H, Neoplasm Transplantation, Oxidation-Reduction, Oxygen, Porphyrins, Spin Labels, Temperature, Time Factors, Molecular Structure, Myocytes, Smooth Muscle, Cell Line, Tumor, Mice
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.