Novel particulate spin probe for targeted determination of oxygen in cells and tissues
The DOI matches its Crossref record; 43 of the 44 references it cites were found in a registry or an index.
Abstract
The synthesis and characterization of a new lithium octa-n-butoxy-substituted naphthalocyanine radical probe (LiNc-BuO) and its use in the determination of concentration of oxygen (oximetry) by electron paramagnetic resonance (EPR) spectroscopy are reported. The probe is synthesized as a needle-shaped microcrystalline particulate. The particulate shows a single-line EPR spectrum that is highly exchange-narrowed with a line-width of 210 mG. The EPR line-width is sensitive to molecular oxygen showing a linear relationship between the line-width and concentration of oxygen (pO(2)) with a sensitivity of 8.5 mG/mmHg. We studied a variety of physicochemical and biological properties of LiNc-BuO particulates to evaluate the suitability of the probe for in vivo oximetry. The probe is unaffected by biological oxidoreductants, stable in tissues for several months, and can be successfully internalized in cells. We used this probe to monitor changes in concentration of oxygen in the normal muscle and RIF-1 tumor tissue of mice as a function of tumor growth. The data showed a rapid decrease in the tumor pO(2) with increase of tumor volume. Human arterial smooth muscle cells, upon internalization of the LiNc-BuO probe, showed a marked oxygen gradient across the cell membrane. In summary, the newly synthesized octa-n-butoxy derivative of lithium naphthalocyanine has unique properties that are useful for determining oxygen concentration in chemical and biological systems by EPR spectroscopy and also for magnetic tagging of cells.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“One of the most important characteristics of this approach is that it does not interfere with oxygen metabolism within the biological system, therefore providing a basis for non-invasive oxygen measurements in biological systems [33], a critical requirement for measurement of oxygen within 3D models [29].”
From Direct Measurements of Oxygen Gradients in Spheroid Culture System Using Electron Parametric Resonance Oximetry (2016) · cites this paper as [33]
Citations
Cites
Wang, Y.-X. J., Hussain, S. M., & Krestin, G. P. (2001) · European Radiology · doi:10.1007/s003300100908 · Cited by 1,381
Vaupel, P. W., Schlenger, K., Knoop, C., & Höckel, M. (1991) · PubMed · Cited by 1,118
Noninvasive imaging of tumor redox status and its modification by tissue glutathione levels.
Kuppusamy, P., Li, H., Ilangovan, G., Cardounel, A. J., Zweier, J. L., Yamada, K., Krishna, M. C., & Mitchell, J. B. (2002) · PubMed · Cited by 832
Self-citationKooi, M. E., Cappendijk, V. C., Cleutjens, K. B. J. M., Kessels, A. G. H., Kitslaar, P. J. E. H. M., Borgers, M., Frederik, P. M., Daemen, M. J. A. P., & van Engelshoven, J. M. A. (2003) · Circulation · doi:10.1161/01.cir.0000068315.98705.cc · Cited by 798
Hinds, K. A., Hill, J. M., Shapiro, E. M., Laukkanen, M. O., Silva, A. C., Combs, C. A., Varney, T. R., Balaban, R. S., Koretsky, A. P., & Dunbar, C. E. (2003) · Blood · doi:10.1182/blood-2002-12-3669 · Cited by 401
Noninvasive Evaluation of Intrarenal Oxygenation With BOLD MRI
Prasad, P. V., Edelman, R. R., & Epstein, F. H. (1996) · Circulation · doi:10.1161/01.cir.94.12.3271 · Cited by 399
Bonnemain, B. (1998) · Journal of Drug Targeting · doi:10.3109/10611869808997890 · Cited by 371
Liu, K. J., Gast, P., Moussavi, M., Norby, S. W., Vahidi, N., Walczak, T., Wu, M., & Swartz, H. M. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.12.5438 · Cited by 318
Krishna, M. C., English, S., Yamada, K., Yoo, J., Murugesan, R., Devasahayam, N., Cook, J. A., Golman, K., Ardenkjaer-Larsen, J. H., Subramanian, S., et al. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.042671399 · Cited by 304
A new series of molecular semiconductors: phthalocyanine radicals
Turek, P., Petit, P., Andre, J. J., Simon, J., Even, R., Boudjema, B., Guillaud, G., & Maitrot, M. (1987) · Journal of the American Chemical Society · doi:10.1021/ja00251a012 · Cited by 262
Cited by
Yamamori, T., Yasui, H., Yamazumi, M., Wada, Y., Nakamura, Y., Nakamura, H., & Inanami, O. (2012) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2012.04.033 · Cited by 396
Keeley, T. P., & Mann, G. E. (2019) · Physiological Reviews · doi:10.1152/physrev.00041.2017 · Cited by 329
Selective Inhibition of Hypoxia-Inducible Factor 1α Ameliorates Adipose Tissue Dysfunction
Sun, K., Halberg, N., Khan, M., Magalang, U. J., & Scherer, P. E. (2013) · Molecular and Cellular Biology · doi:10.1128/mcb.00951-12 · Cited by 231
“probe to oxygen was calibrated as described previously (43).”
MethodAssessment of tumor oxygenation by electron paramagnetic resonance: principles and applications
Gallez, B., Baudelet, C., & Jordan, B. F. (2004) · NMR in Biomedicine · doi:10.1002/nbm.900 · Cited by 222
“In several studies, measurements of tumor oxygenation using EPR have been carried out as a proof of principle in order to show that a specific method or a newly developed paramagnetic material was applicable for this purpose.(119,183,160,214,221,222) In other studies, EPR oximetry was compared with other methods that…”
Injectable, rapid gelling and highly flexible hydrogel composites as growth factor and cell carriers
Wang, F., Li, Z., Khan, M., Tamama, K., Kuppusamy, P., Wagner, W. R., Sen, C. K., & Guan, J. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.12.011 · Cited by 188
Self-citationTheory, Instrumentation, and Applications of Electron Paramagnetic Resonance Oximetry
Ahmad, R., & Kuppusamy, P. (2010) · Chemical Reviews · doi:10.1021/cr900396q · Cited by 166
Self-citationEubank, T. D., Roberts, R. D., Khan, M., Curry, J. M., Nuovo, G. J., Kuppusamy, P., & Marsh, C. B. (2009) · Cancer Research · doi:10.1158/0008-5472.can-08-1405 · Cited by 166
Self-citationEffects of static magnetic fields in biology: role of free radicals
Okano, H. (2008) · Frontiers in bioscience · doi:10.2741/3141 · Cited by 137
“In addition, electron paramagnetic resonance (EPR) or electron spin resonance (ESR) spectroscopy is an extremely powerful tool for direct detection and quantification of free radicals (171-172).”
BackgroundSelvendiran, K., Bratasz, A., Kuppusamy, M. L., Tazi, M., Rivera, B. K., & Kuppusamy, P. (2009) · International Journal of Cancer · doi:10.1002/ijc.24601 · Cited by 136
“When the tumors reached about 10–12 mm size in the largest dimension, tumor tissue oxygenation (pO2) was measured by electron paramagnetic resonance (EPR) oximetry using lithium octan-butoxy-naphthalocyanine (LiNc-BuO) microcrystals (10–30 lm size) as probe.(22) Mice were anesthetized with 1.”
BackgroundMethodSelf-citationZhao, X., He, G., Chen, Y.-R., Pandian, R. P., Kuppusamy, P., & Zweier, J. L. (2005) · Circulation · doi:10.1161/circulationaha.104.527226 · Cited by 118
Self-citationLangan, L. M., Dodd, N. J. F., Owen, S. F., Purcell, W. M., Jackson, S. K., & Jha, A. N. (2016) · PLOS ONE · doi:10.1371/journal.pone.0149492 · Cited by 104
“One of the most important characteristics of this approach is that it does not interfere with oxygen metabolism within the biological system, therefore providing a basis for non-invasive oxygen measurements in biological systems [33], a critical requirement for measurement of oxygen within 3D models [29].”
Hypoxic reperfusion of the ischemic heart and oxygen radical generation
Angelos, M. G., Kutala, V. K., Torres, C. A., He, G., Stoner, J. D., Mohammad, M., & Kuppusamy, P. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00223.2005 · Cited by 101
“This technique allows measurement of the absolute tissue PO2 values ranging from very low oxygen levels to supranormal physiological levels.”
MethodSelf-citationAbsolute oxygen tension (pO2) in murine fatty and muscle tissue as determined by EPR
Matsumoto, A., Matsumoto, S., Sowers, A. L., Koscielniak, J. W., Trigg, N. J., Kuppusamy, P., Mitchell, J. B., Subramanian, S., Krishna, M. C., & Matsumoto, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20714 · Cited by 92
Self-citationKempe, S., Metz, H., & Mäder, K. (2009) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2009.08.007 · Cited by 90
Swartz, H. M., Williams, B. B., Zaki, B. I., Hartford, A. C., Jarvis, L. A., Chen, E. Y., Comi, R. J., Ernstoff, M. S., Hou, H. G., Khan, N. I., et al. (2014) · Academic Radiology · doi:10.1016/j.acra.2013.10.011 · Cited by 101
“Although we have alternative probes, based on LiPc derivatives (33,47,66) that are much superior to India ink in terms”
Self-citationElas, M., Bell, R., Hleihel, D., Barth, E. D., McFaul, C. A., Haney, C. R., Bielańska, J., Pustelny, K., Ahn, K., Pelizzari, C. A., et al. (2008) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2008.02.022 · Cited by 87
Regulation of Cellular Gas Exchange, Oxygen Sensing, and Metabolic Control
Clanton, T. L., Hogan, M. C., & Gladden, L. B. (2013) · Comprehensive Physiology · doi:10.1002/cphy.c120030 · Cited by 80
Crowther, J. E., Kutala, V. K., Kuppusamy, P., Ferguson, J. S., Beharka, A. A., Zweier, J. L., McCormack, F. X., & Schlesinger, L. S. (2004) · The Journal of Immunology · doi:10.4049/jimmunol.172.11.6866 · Cited by 80
“Oxygen concentration in the reaction mixture over time was measured in sealed capillary tubes, with a minimum of two tubes per condition, by EPR oximetry using the oxygensensitive probe lithium 5,9,14,18,23,27,32,36-octa-n-butoxy-2,3-naphthalocyanine (LiNc-BuO), whose line width and shape in EPR correspond to the pO2…”
MethodSelf-citationTran, L. B. A., Bol, A., Labar, D., Jordan, B. F., Magat, J., Mignion, L., Grégoire, V., & Gallez, B. (2012) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2012.04.011 · Cited by 78
Khan, M., Meduru, S., Mostafa, M., Khan, S., Hideg, K., & Kuppusamy, P. (2010) · Journal of Pharmacology and Experimental Therapeutics · doi:10.1124/jpet.109.165175 · Cited by 68
“The peak-to-peak width of the EPR spectrum was used to calculate pO2 using a standard calibration curve (Pandian et al., 2003).”
MethodSelf-citationRole of Oxygen in Postischemic Myocardial Injury
Kutala, V. K., Khan, M., Angelos, M. G., & Kuppusamy, P. (2007) · Antioxidants and Redox Signaling · doi:10.1089/ars.2007.1636 · Cited by 75
“During the last two decades, several new probes have become available for EPR oximetry (45, 59, 110).”
Self-citationJones, C. I., Han, Z., Presley, T. D., Varadharaj, S., Zweier, J. L., Ilangovan, G., & Alevriadou, B. R. (2008) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00549.2007 · Cited by 67
Self-citationIn vivo imaging of changes in tumor oxygenation during growth and after treatment
Bratasz, A., Pandian, R. P., Deng, Y., Petryakov, S. V., Grecula, J. C., Gupta, N., & Kuppusamy, P. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21212 · Cited by 63
“Lithium octa-n-butoxy-naphthalocyanine (LiNcBuO) was synthesized as previously reported (27,28).”
BackgroundMethodSelf-citationNoninvasive Monitoring of Small Intestinal Oxygen in a Rat Model of Chronic Mesenteric Ischemia
Fisher, E., Khan, M., Salisbury, R. L., & Kuppusamy, P. (2013) · Cell Biochemistry and Biophysics · doi:10.1007/s12013-013-9611-y · Cited by 66
“Sensitivity is calculated as the difference between room air O2 and tissue anoxia, divided by O2 at 1 ATM [12].”
BackgroundInfluentialSelf-citationHussain, S.-R. A., Lucas, D. M., Johnson, A. J., Lin, T. S., Bakaletz, A. P., Dang, V., Viatchenko‐Karpinski, S., Ruppert, A. S., Byrd, J. C., Kuppusamy, P., et al. (2008) · Blood · doi:10.1182/blood-2007-10-115733 · Cited by 61
Self-citationIntermittent Hypoxia Exacerbates Pancreatic β-Cell Dysfunction in A Mouse Model of Diabetes Mellitus
Sherwani, S. I., Aldana, C., Usmani, S., Adin, C., Kotha, S., Khan, M., Eubank, T., Scherer, P. E., Parinandi, N., & Magalang, U. J. (2013) · Sleep · doi:10.5665/sleep.3214 · Cited by 56
Self-citationKhan, M., Kutala, V. K., Vikram, D. S., Wisel, S., Chacko, S. M., Kuppusamy, M. L., Mohan, I. K., Zweier, J. L., Kwiatkowski, P. A., & Kuppusamy, P. (2007) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00677.2007 · Cited by 55
“The peak-to-peak width of the EPR spectrum was used to calculate PO2 using a standard calibration curve (27).”
BackgroundMethodSelf-citationMeenakshisundaram, G., Eteshola, E., Pandian, R. P., Bratasz, A., Selvendiran, K., Lee, S. C., Krishna, M. C., Swartz, H. M., & Kuppusamy, P. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9298-4 · Cited by 58
“…15.6±2.9 mmHg, which is within the range of mouse gastrocnemius muscle pO2 values reported previously, using unencapsulated LiNc-BuO (19.6±2.1 mmHg) (Pandian et al. 2003), LiNc (17.6± 2.5 mmHg) (Ilangovan et al. 2002a), LiPc (18±4 mmHg) (Ilangovan et al. 2004a), and TAF-coated LiPc (15.5± 1.5…”
BackgroundMethodSelf-citationChacko, S. M., Khan, M., Kuppusamy, M. L., Pandian, R. P., Varadharaj, S., Selvendiran, K., Bratasz, A., Rivera, B. K., & Kuppusamy, P. (2009) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01311.2008 · Cited by 53
“Microcrystalline particulates of lithium 5,9,14,18,23,27,32,36-octa-nbutoxy-2,3-naphthalocyanine (LiNc-BuO) were used as OxySpin (25).”
MethodSelf-citationKutala, V. K., Parinandi, N. L., Pandian, R. P., & Kuppusamy, P. (2004) · Antioxidants and Redox Signaling · doi:10.1089/152308604773934350 · Cited by 54
“In our recent study, we used the LiNc-BuO particulate probe and measured the rate of oxygen consumption in mouse aortic endothelial cells in the presence of various stimulants and inhibitors of respiration (21) and also measured the pO 2 in normal and tumor tissues (22).”
InfluentialSelf-citationKhramtsov, V. V. (2018) · Antioxidants and Redox Signaling · doi:10.1089/ars.2017.7329 · Cited by 59
“Alternative probes such as LiPc derivatives (76, 89, 91) have an advantage over India ink in oxygen sensitivity.”
Epel, B., & Halpern, H. J. (2015) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/bs.mie.2015.08.017 · Cited by 53
Pre-clinical evaluation of OxyChip for long-term EPR oximetry
Hou, H. G., Khan, N. I., Gohain, S., Kuppusamy, M. L., & Kuppusamy, P. (2018) · Biomedical Microdevices · doi:10.1007/s10544-018-0272-x · Cited by 48
“2002a, 2003, 2004) and derivatives (Ilangovan et al. 2002b; Pandian et al. 2003).”
BackgroundMethodSelf-citationMeenakshisundaram, G., Eteshola, E., Pandian, R. P., Bratasz, A., Lee, S. C., & Kuppusamy, P. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9292-x · Cited by 45
“These particulate EPR probes can all be used in their neat crystalline form to sense molecular oxygen (Ilangovan et al. 2002; Liu et al. 1993; Pandian et al. 2003b), but may have limitations associated with particle migration within the tissue, (diffusing and decreasing EPR signal over time) and,…”
BackgroundMethodSelf-citationKhan, M., Mohan, I. K., Kutala, V. K., Kotha, S. R., Parinandi, N. L., Hamlin, R. L., & Kuppusamy, P. (2009) · Antioxidants and Redox Signaling · doi:10.1089/ars.2008.2155 · Cited by 44
“Li-thium octa-n -butoxy-naphthalocyanine (LiNc-BuO) oximetry probe was synthesized as reported (47).”
InfluentialSelf-citationTranscutaneous oxygen measurement in humans using a paramagnetic skin adhesive film
Kmieć, M. M., Hou, H. G., Kuppusamy, M. L., Drews, T. M., Prabhat, A. M., Petryakov, S. V., Demidenko, E., Schaner, P. E., Buckey, J. C., Blank, A., et al. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27445 · Cited by 44
Self-citationAdvances in Probes and Methods for Clinical EPR Oximetry
Swartz, H. M., Hou, H. G., Khan, N. I., Jarvis, L. A., Chen, E. Y., Williams, B. B., & Kuppusamy, P. (2014) · Advances in experimental medicine and biology · doi:10.1007/978-1-4939-0620-8_10 · Cited by 51
Self-citationGogna, R., Madan, E., Kuppusamy, P., & Pati, U. (2012) · Cell Death & Disease · doi:10.1038/cddis.2012.15 · Cited by 40
“The peak-to-peak width of the EPR spectrum was used to calculate pO2 using a standard calibration curve, as reported.(22)”
MethodSelf-citationPost-cardiac arrest hyperoxia and mitochondrial function
Angelos, M. G., Yeh, S. T.-Y., & Aune, S. E. (2011) · Resuscitation · doi:10.1016/s0300-9572(11)70151-4 · Cited by 39
Pandian, R. P., Kim, Y., Woodward, P. M., Zweier, J. L., Manoharan, P. T., & Kuppusamy, P. (2006) · Journal of Materials Chemistry · doi:10.1039/b517976a · Cited by 40
Self-citationNagane, M., Yasui, H., Yamamori, T., Zhao, S., Kuge, Y., Tamaki, N., Kameya, H., Nakamura, H., Fujii, H. G., & Inanami, O. (2013) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2013.06.093 · Cited by 35
Presley, T., Kuppusamy, P., Zweier, J. L., & Ilangovan, G. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.090175 · Cited by 34
Self-citationThe Role of Imaging Biomarkers to Guide Pharmacological Interventions Targeting Tumor Hypoxia
Gallez, B. (2022) · Frontiers in Pharmacology · doi:10.3389/fphar.2022.853568 · Cited by 37
Xu, Y., Liu, B., Zweier, J. L., & He, G. (2008) · Journal of Pharmacology and Experimental Therapeutics · doi:10.1124/jpet.108.142372 · Cited by 37
“EPR oximetry, due to its noninvasive property, has emerged as a widely used method for measuring cellular, tissue, organ, and even whole-body tissue Po2 in different models (He et al., 1999; Pandian et al., 2003).”
Self-citationSchaner, P. E., Williams, B. B., Chen, E. Y., Pettus, J. R., Schreiber, W. A., Kmieć, M. M., Jarvis, L. A., Pastel, D. A., Zuurbier, R. A., diFlorio‐Alexander, R. M., et al. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2021.743256 · Cited by 38
Self-citationDirect and Repeated Measurement of Heart and Brain Oxygenation Using In Vivo EPR Oximetry
Khan, N. I., Hou, H. G., Swartz, H. M., & Kuppusamy, P. (2015) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/bs.mie.2015.06.023 · Cited by 38
Self-citationESR Microscopy and Nanoscopy with “Induction” Detection
Blank, A., & Freed, J. H. (2006) · Israel Journal of Chemistry · doi:10.1560/ijc_46_4_423 · Cited by 34
Deng, Y., Pandian, R. P., Ahmad, R., Kuppusamy, P., & Zweier, J. L. (2006) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.05.010 · Cited by 32
“A recently developed particulate lithium octa-n-butoxy-substitued naphthalocyanine (LiNc-BuO) [9,22] was used for linewidth measurements.”
BackgroundMethodResultSelf-citationMohan, I. K., Khan, M., Wisel, S., Selvendiran, K., Sridhar, A., Carnes, C. A., Bognár, B., Kálai, T., Hideg, K., & Kuppusamy, P. (2008) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00687.2008 · Cited by 32
“The technology has been well-validated for measurements of pO2 from single cells to whole organs (35, 40, 50).”
MethodSelf-citationDevelopment of an L-band rapid scan EPR digital console
Sato‐Akaba, H., & Tseytlin, M. (2019) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2019.05.003 · Cited by 31
Oxygen and oxygenation in stem-cell therapy for myocardial infarction
Khan, M., Kwiatkowski, P. A., Rivera, B. K., & Kuppusamy, P. (2010) · Life Sciences · doi:10.1016/j.lfs.2010.06.013 · Cited by 31
“The crystalline form of lithium octa-n-butoxy-substituted naphthalocyanine radical (LiNc– BuO) is a particulate oximetry spin probe that we have recently synthesized and validated for in vivo oximetry (Chacko et al. 2009; Pandian et al. 2003; Wisel et al. 2007).”
BackgroundMethodSelf-citationElectron paramagnetic resonance oxygen imaging in vivo
Epel, B., & Halpern, H. J. (2012) · Royal Society of Chemistry eBooks · doi:10.1039/9781849734837-00180 · Cited by 32
Kmieć, M. M., Tse, D., Mast, J. M., Ahmad, R., & Kuppusamy, P. (2019) · Biomedical Microdevices · doi:10.1007/s10544-019-0421-x · Cited by 34
Self-citationButt, O. I., Carruth, R. W., Kutala, V. K., Kuppusamy, P., & Moldovan, N. I. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0225 · Cited by 29
“13 To this end, we took advantage of an L-band EPR spectrometer that we adapted for EPR measurements on mice and other small animals.”
Self-citationFujii, H. G., Sakata, K., Katsumata, Y., Rikiya, S., Kinouchi, M., Someya, M., Masunaga, S., Hareyama, M., Swartz, H. M., & Hirata, H. (2008) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2007.11.020 · Cited by 32
“LiNc-BuO was prepared according to the previously reported method [13] with slight modifications.”
MethodAdvanced surface resonators for electron spin resonance of single microcrystals
Dayan, N. A., Ishay, Y., Artzi, Y., Cristea, D., Reijerse, E. J., Kuppusamy, P., & Blank, A. (2018) · Review of Scientific Instruments · doi:10.1063/1.5063367 · Cited by 27
Self-citationPandian, R. P., Kutala, V. K., Liaugminas, A., Parinandi, N. L., & Kuppusamy, P. (2005) · Molecular and Cellular Biochemistry · doi:10.1007/s11010-005-6936-x · Cited by 30
“Microcrystalline particulates of lithium 5,9,14,18,23,27,32, 36-octa-n-butoxy-2,3-naphthalocyanine (LiNc-BuO) were used for measuring oxygen concentration by EPR spectroscopy [29].”
MethodSelf-citationCancer chemopreventive oltipraz generates superoxide anion radical
Velayutham, M., Villamena, F. A., Fishbein, J. C., & Zweier, J. L. (2004) · Archives of Biochemistry and Biophysics · doi:10.1016/j.abb.2004.11.028 · Cited by 30
Self-citationCharlier, N., Beghein, N., & Gallez, B. (2004) · NMR in Biomedicine · doi:10.1002/nbm.902 · Cited by 26
Hashimoto, M., Saito, N., Ohta, H., Yamamoto, K., Tashiro, A., Nakazawa, K., Inanami, O., & Kitamura, H. (2019) · Physiological Reports · doi:10.14814/phy2.14193 · Cited by 28
“36-octa-n-butoxy-2,3naphthalocyanine (LiNc-BuO) was synthesized according to the method previously described (Pandian et al., 2003).”
MethodInfluentialElectron spin resonance microscopic imaging of oxygen concentration in cancer spheroids
Hashem, M., Weiler-Sagie, M., Kuppusamy, P., Neufeld, G., Neeman, M., & Blank, A. (2015) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2015.04.012 · Cited by 25
Self-citationNano-emulsions of fluorinated trityl radicals as sensors for EPR oximetry
Charlier, N., Driesschaert, B., Wauthoz, N., Beghein, N., Véronique Préat, A., Amighi, K., Marchand‐Brynaert, J., & Gallez, B. (2008) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2008.12.013 · Cited by 26
“The particulate probes include lithium phthalocyanine [4] and naphthalocyanine crystals [5], natural charcoals [6,7], analytical charcoals [8,9], India inks [10,11], and carbon blacks [12].”
BackgroundA Highly Sensitive Biocompatible Spin Probe for Imaging of Oxygen Concentration in Tissues
Bratasz, A., Kulkarni, A. C., & Kuppusamy, P. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.099135 · Cited by 30
“This value is also higher when compared to the sensitivity of particulate probes such as lithium phthalocyanine (38,39) and lithium butoxynaphthalocyanine (40).”
ResultSelf-citationPandian, R. P., Dolgos, M., Marginean, C., Woodward, P. M., Hammel, P. C., Manoharan, P. T., & Kuppusamy, P. (2009) · Journal of Materials Chemistry · doi:10.1039/b901886g · Cited by 25
Self-citationA three-dimensional electron spin resonance microscope
Blank, A., Dunnam, C. R., Borbat, P. P., & Freed, J. H. (2004) · Review of Scientific Instruments · doi:10.1063/1.1786353 · Cited by 23
Pandian, R. P., Raju, N. P., Gallucci, J. C., Woodward, P. M., Epstein, A. J., & Kuppusamy, P. (2010) · Chemistry of Materials · doi:10.1021/cm101733h · Cited by 25
Self-citationEPR oximetry in three spatial dimensions using sparse spin distribution
Som, S., Potter, L. C., Ahmad, R., Vikram, D. S., & Kuppusamy, P. (2008) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2008.05.004 · Cited by 26
Self-citationKhan, M., Kutala, V. K., Wisel, S., Chacko, S. M., Kuppusamy, M. L., Kwiatkowski, P. A., & Kuppusamy, P. (2008) · Advances in experimental medicine and biology · doi:10.1007/978-0-387-74911-2_6 · Cited by 22
Self-citationFull cycle rapid scan EPR deconvolution algorithm
Tseytlin, M. (2017) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2017.06.008 · Cited by 21
“Locally synthesized Lithium octa-n-butoxy 2,3-naphthalocyanine (LiNc-BuO) microcrystals were used to compare the half-cycle and full-cycle deconvolution algorithms [29, 30].”
MethodThe evolution of biomedical EPR (ESR)
Berliner, L. J. (2016) · Biomedical Spectroscopy and Imaging · doi:10.3233/bsi-150128 · Cited by 28
“that reported oxygen tension via the same type of Heisenberg exchange line broadening of its single narrow linewidth line [20,68,75,76,98].”
Gallez, B. (2021) · Applied Magnetic Resonance · doi:10.1007/s00723-021-01358-7 · Cited by 22
Rivera, B. K., Naidu, S. K., Subramanian, K., Joseph, M., Hou, H. G., Khan, N. I., Swartz, H. M., & Kuppusamy, P. (2014) · Advances in experimental medicine and biology · doi:10.1007/978-1-4939-0620-8_11 · Cited by 20
“The sensory element of the tip was created by mixing LiNc-BuO (lithium octa-nbutoxynaphthalocyanine) oxygen-sensing crystals [5] in uncured polydimethylsiloxane (PDMS; 1 part cure accelerant: 10 parts base, w/w; Factor II, Inc.”
MethodSelf-citationMeenakshisundaram, G., Pandian, R. P., Eteshola, E., Lee, S. C., & Kuppusamy, P. (2009) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2009.11.016 · Cited by 22
“Lithium naphthalocyanine (LiNc) is a particulate EPR oximetry probe that possesses significantly higher oxygen sensitivity (of the order of 30 mG/mmHg) [8] than other crystalline probes, such as lithium phthalocyanine (~ 6–7 mG/mmHg) [9;10] and lithium octa-n-butoxynaphthalocyanine (~8–9 mG/mmHg) [11].”
BackgroundSelf-citationWisel, S., Chacko, S. M., Kuppusamy, M. L., Pandian, R. P., Khan, M., Kutala, V. K., Burry, R. W., Sun, B., Kwiatkowski, P. A., & Kuppusamy, P. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01058.2006 · Cited by 20
Self-citationBobko, A. A., Eubank, T. D., Driesschaert, B., & Khramtsov, V. V. (2018) · Journal of Visualized Experiments · doi:10.3791/56624 · Cited by 23
Polymer coating of paramagnetic particulates for in vivo oxygen-sensing applications
Eteshola, E., Pandian, R. P., Lee, S. C., & Kuppusamy, P. (2008) · Biomedical Microdevices · doi:10.1007/s10544-008-9244-x · Cited by 19
“Particulate probes show a single-line EPR spectrum that is highly exchangenarrowed (Ilangovan et al. 2004a, b; Ilangovan et al. 2002a; Liu et al. 1993; Pandian et al. 2003b).”
BackgroundMethodSelf-citationElectron spin resonance microscopy applied to the study of controlled drug release
Blank, A., Freed, J. H., Naraharisetti, P. K., & Wang, C. (2006) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.11.019 · Cited by 21
“In the future, one may use different radicals, possibly solid LiPc-type radicals [39,40] as the reference signal source.”
BackgroundHou, H. G., Khan, N. I., Nagane, M., Gohain, S., Chen, E. Y., Jarvis, L. A., Schaner, P. E., Williams, B. B., Flood, A. B., Swartz, H. M., et al. (2016) · Advances in experimental medicine and biology · doi:10.1007/978-3-319-38810-6_46 · Cited by 19
Self-citationA Comparative Evaluation of EPR and OxyLite Oximetry Using a Random Sampling ofpO2in a Murine Tumor
Vikram, D. S., Bratasz, A., Ahmad, R., & Kuppusamy, P. (2007) · Radiation Research · doi:10.1667/rr0854.1 · Cited by 19
Self-citationCristea, D., Krishtul, S., Kuppusamy, P., Baruch, L., Machluf, M., & Blank, A. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.10.032 · Cited by 20
Self-citationESR micro-imaging of LiNc-BuO crystals in PDMS: Spatial and spectral grain distribution
Blank, A., Halevy, R., Shklyar, M., Shtirberg, L., & Kuppusamy, P. (2009) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2009.12.011 · Cited by 18
“trityl [6], lithium phthalocyanine (LiPc) [7], or lithium octa-n-butoxynaphthalocyanine (LiNc-BuO) [8]).”
BackgroundMethodSelf-citationPandian, R. P., Dang, V., Manoharan, P. T., Zweier, J. L., & Kuppusamy, P. (2006) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.04.004 · Cited by 17
Self-citationSostaric, J. Z., Pandian, R. P., Weavers, L. K., & Kuppusamy, P. (2006) · Chemistry of Materials · doi:10.1021/cm060751l · Cited by 17
Self-citationUeno, M., Matsumoto, S., Matsumoto, A., Manda, S., Nakanishi, I., Matsumoto, K., Mitchell, J. B., Krishna, M. C., & Anzai, K. (2017) · Journal of Clinical Biochemistry and Nutrition · doi:10.3164/jcbn.15-130 · Cited by 16
Pandian, R. P., Dolgos, M., Dang, V., Sostaric, J. Z., Woodward, P. M., & Kuppusamy, P. (2007) · Chemistry of Materials · doi:10.1021/cm070622k · Cited by 18
Self-citationMeasuring Brain Tissue Oxygenation under Oxidative Stress by ESR/MR Dual Imaging System
Fujii, H. G., Itoh, K., Pandian, R. P., Sakata, M., Kuppusamy, P., & Hirata, H. (2007) · Magnetic Resonance in Medical Sciences · doi:10.2463/mrms.6.83 · Cited by 15
“Because paramagnetic LiNc-BuO microcrystals are very inert in biological systems and can be made in sub-micron-sized particles or smaller, internalization of LiNc-BuO particles into a wide variety of cells is feasible.(13) Cells labeled with LiNc-BuO can be tracked indirectly by high-ˆeld MR imaging based on the eŠect…”
BackgroundMethodSelf-citationSostaric, J. Z., Pandian, R. P., Bratasz, A., & Kuppusamy, P. (2007) · The Journal of Physical Chemistry B · doi:10.1021/jp0682356 · Cited by 18
Self-citationIn vivo multisite oximetry using EPR–NMR coimaging
Ahmad, R., Caia, G., Potter, L. C., Petryakov, S. V., Kuppusamy, P., & Zweier, J. L. (2010) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2010.08.011 · Cited by 14
“In fact, particulate EPR probes can stay in a biological sample for months [10] without losing their oxygen sensitivity.”
BackgroundSelf-citationKubota, H., Komarov, D. A., Yasui, H., Matsumoto, S., Inanami, O., Kirilyuk, I. A., Khramtsov, V. V., & Hirata, H. (2017) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-016-0606-8 · Cited by 13
Measuring Flap Oxygen Using Electron Paramagnetic Resonance Oximetry
Polacco, M. A., Hou, H. G., Kuppusamy, P., & Chen, E. Y. (2019) · The Laryngoscope · doi:10.1002/lary.28043 · Cited by 13
Self-citationFlood, A. B., Schaner, P. E., Vaupel, P. W., Williams, B. B., Gallez, B., Chen, E. Y., Ali, A. N., Liu, T., Lawson, V. H., Schreiber, W., et al. (2020) · Advances in experimental medicine and biology · doi:10.1007/978-3-030-34461-0_20 · Cited by 14
Effect of Oxygenation on Stem-Cell Therapy for Myocardial Infarction
Khan, M., Meduru, S., Pandian, R. P., Rivera, B. K., & Kuppusamy, P. (2011) · Advances in experimental medicine and biology · doi:10.1007/978-1-4419-7756-4_24 · Cited by 13
Self-citationZdybel, M., Pilawa, B., Buszman, E., & Wrześniok, D. M. (2012) · Chemical Physics Letters · doi:10.1016/j.cplett.2012.12.004 · Cited by 13
Yamamoto, K., Ikenaka, Y., Ichise, T., Bo, T., Ishizuka, M., Yasui, H., Hiraoka, W., Yamamori, T., & Inanami, O. (2018) · Free Radical Research · doi:10.1080/10715762.2018.1460472 · Cited by 15
Bobko, A. A., Evans, J. V., Denko, N. C., & Khramtsov, V. V. (2016) · Cell Biochemistry and Biophysics · doi:10.1007/s12013-016-0733-x · Cited by 12
“LiNc-BuO microcrystals were synthesized and prepared as described in [15, 25].”
MethodSarvari, S., McGee, D. S., O’Connell, R. C., Tseytlin, O., Bobko, A. A., & Tseytlin, M. (2023) · Molecular Imaging and Biology · doi:10.1007/s11307-023-01871-0 · Cited by 12
“The linewidth maps were converted into oxygen images using a known linear calibration function [66].”
MethodDevelopment of a fast‐scan EPR imaging system for highly accelerated free radical imaging
Samouilov, A., Ahmad, R., Boslett, J. J., Liu, X., Petryakov, S. V., & Zweier, J. L. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27759 · Cited by 12
Self-citationCompact electron spin resonance skin oximeter: Properties and initial clinical results
Cristea, D., Wolfson, H., Ahmad, R., Twig, Y., Kuppusamy, P., & Blank, A. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28595 · Cited by 11
Self-citationSurface dielectric resonator for in vivo EPR measurements
Petryakov, S. V., Kmieć, M. M., Ubert, C. S., Kassey, V. B., Schaner, P. E., & Kuppusamy, P. (2024) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2024.107690 · Cited by 11
Self-citationDancing with the Electrons: Time-Domain and CW In Vivo EPR Imaging
Subramanian, S., & Krishna, M. C. (2008) · Magnetic Resonance Insights · doi:10.4137/mri.s1131 · Cited by 18
Metadata
- Authors
- Pandian, R. P., Parinandi, N. L., Ilangovan, G., Zweier, J. L., & Kuppusamy, P.
- Affiliations
- The Ohio State University (US)
- Corresponding author
- Kuppusamy, Periannan
- Venue
- Free Radical Biology and Medicine
- Publisher
- Elsevier BV
- Published
- 2003-11
- Volume
- 35
- Issue
- 9
- Pages
- 1138-1148
- ISSN
- 0891-5849 (ISSN-L)
- OpenAlex
- W1989313199
- Semantic Scholar
- 1da5a57ca95c7e7c600c41ec1f62f0aa7f006841
- Cited by
- 150
- References
- 44
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 6 · 2023: 2 · 2022: 1 · 2021: 5 · 2020: 3 · 2019: 9 · 2018: 11 · 2017: 8 · 2016: 6 · 2015: 5 · 2014: 5 · 2013: 8 · 2012: 7
- FWCI
- 4.16
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Free Radical Biology and Medicine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health
- National Cancer Institute (R01CA078886, CA78886)
- National Institute of Biomedical Imaging and Bioengineering (EB 00306, R01EB000306)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Electron Spin Resonance Studies
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Toxicology › Bioactive Compounds and Antitumor Agents
- Keywords
- oxygen sensing, oximetry, exchange narrowing, EPR linewidth, tumor hypoxia, arterial smooth muscle cells, cellular internalization
- MeSH terms
- Animals, Electron Spin Resonance Spectroscopy, Female, Fibrosarcoma, Gamma Rays, Humans, Hydrogen-Ion Concentration, Mice, Inbred C3H, Neoplasm Transplantation, Oxidation-Reduction, Oxygen, Porphyrins, Spin Labels, Temperature, Time Factors, Molecular Structure, Myocytes, Smooth Muscle, Cell Line, Tumor, Mice
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.