Novel particulate spin probe for targeted determination of oxygen in cells and tissues
The DOI matches its Crossref record; 43 of the 44 references it cites were found in a registry or an index.
Abstract
The synthesis and characterization of a new lithium octa-n-butoxy-substituted naphthalocyanine radical probe (LiNc-BuO) and its use in the determination of concentration of oxygen (oximetry) by electron paramagnetic resonance (EPR) spectroscopy are reported. The probe is synthesized as a needle-shaped microcrystalline particulate. The particulate shows a single-line EPR spectrum that is highly exchange-narrowed with a line-width of 210 mG. The EPR line-width is sensitive to molecular oxygen showing a linear relationship between the line-width and concentration of oxygen (pO(2)) with a sensitivity of 8.5 mG/mmHg. We studied a variety of physicochemical and biological properties of LiNc-BuO particulates to evaluate the suitability of the probe for in vivo oximetry. The probe is unaffected by biological oxidoreductants, stable in tissues for several months, and can be successfully internalized in cells. We used this probe to monitor changes in concentration of oxygen in the normal muscle and RIF-1 tumor tissue of mice as a function of tumor growth. The data showed a rapid decrease in the tumor pO(2) with increase of tumor volume. Human arterial smooth muscle cells, upon internalization of the LiNc-BuO probe, showed a marked oxygen gradient across the cell membrane. In summary, the newly synthesized octa-n-butoxy derivative of lithium naphthalocyanine has unique properties that are useful for determining oxygen concentration in chemical and biological systems by EPR spectroscopy and also for magnetic tagging of cells.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“One of the most important characteristics of this approach is that it does not interfere with oxygen metabolism within the biological system, therefore providing a basis for non-invasive oxygen measurements in biological systems [33], a critical requirement for measurement of oxygen within 3D models [29].”
From Direct Measurements of Oxygen Gradients in Spheroid Culture System Using Electron Parametric Resonance Oximetry (2016) · cites this paper as [33]
Citations
Cites
Wang, Y.-X. J., Hussain, S. M., & Krestin, G. P. (2001) · European Radiology · doi:10.1007/s003300100908 · Cited by 1,381
Vaupel, P. W., Schlenger, K., Knoop, C., & Höckel, M. (1991) · PubMed · Cited by 1,118
Noninvasive imaging of tumor redox status and its modification by tissue glutathione levels.
Kuppusamy, P., Li, H., Ilangovan, G., Cardounel, A. J., Zweier, J. L., Yamada, K., Krishna, M. C., & Mitchell, J. B. (2002) · PubMed · Cited by 832
Self-citationKooi, M. E., Cappendijk, V. C., Cleutjens, K. B. J. M., Kessels, A. G. H., Kitslaar, P. J. E. H. M., Borgers, M., Frederik, P. M., Daemen, M. J. A. P., & van Engelshoven, J. M. A. (2003) · Circulation · doi:10.1161/01.cir.0000068315.98705.cc · Cited by 798
Hinds, K. A., Hill, J. M., Shapiro, E. M., Laukkanen, M. O., Silva, A. C., Combs, C. A., Varney, T. R., Balaban, R. S., Koretsky, A. P., & Dunbar, C. E. (2003) · Blood · doi:10.1182/blood-2002-12-3669 · Cited by 401
Noninvasive Evaluation of Intrarenal Oxygenation With BOLD MRI
Prasad, P. V., Edelman, R. R., & Epstein, F. H. (1996) · Circulation · doi:10.1161/01.cir.94.12.3271 · Cited by 399
Bonnemain, B. (1998) · Journal of Drug Targeting · doi:10.3109/10611869808997890 · Cited by 371
Liu, K. J., Gast, P., Moussavi, M., Norby, S. W., Vahidi, N., Walczak, T., Wu, M., & Swartz, H. M. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.12.5438 · Cited by 318
Krishna, M. C., English, S., Yamada, K., Yoo, J., Murugesan, R., Devasahayam, N., Cook, J. A., Golman, K., Ardenkjaer-Larsen, J. H., Subramanian, S., et al. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.042671399 · Cited by 304
A new series of molecular semiconductors: phthalocyanine radicals
Turek, P., Petit, P., Andre, J. J., Simon, J., Even, R., Boudjema, B., Guillaud, G., & Maitrot, M. (1987) · Journal of the American Chemical Society · doi:10.1021/ja00251a012 · Cited by 262
The measurement of oxygen in vivo using EPR techniques
Swartz, H. M., & Clarkson, R. B. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/7/017 · Cited by 218
Frank, J. A., Zywicke, H., Jordan, E. K., Mitchell, J., Lewis, B. K., Miller, B., Bryant, L. H., & Bulte, J. W. M. (2002) · Academic Radiology · doi:10.1016/s1076-6332(03)80271-4 · Cited by 207
Elas, M., Williams, B. B., Parasca, A., Mailer, C., Pelizzari, C. A., Lewis, M. A., River, J. N., Karczmar, G. S., Barth, E. D., & Halpern, H. J. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10408 · Cited by 194
Vaupel, P., & Höckel, M. (2000) · Medical Radiology · doi:10.1007/978-3-642-58813-6_6 · Cited by 188
Hexafluorobenzene: a Sensitive 19F NMR Indicator of Tumor Oxygenation
Mason, R. P., Rodbumrung, W., & Antich, P. P. (1996) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199605)9:3<125::aid-nbm405>3.0.co;2-f · Cited by 137
Preparation and study of a lithium phthalocyanine radical: optical and magnetic properties
Turek, P., Andre, J. J., Giraudeau, A., & Simon, J. (1987) · Chemical Physics Letters · doi:10.1016/0009-2614(87)87175-0 · Cited by 133
Changes in oxygenation of intracranial tumors with carbogen: A BOLD MRI and EPR oximetry study
Dunn, J. F., O’Hara, J. A., Wadghiri, Y. Z., Lei, H. C., Meyerand, M. E., Grinberg, O. Y., Hou, H. G., Hoopes, P. J., Demidenko, E., & Swartz, H. M. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10192 · Cited by 100
In Vivo and in vitro EPR oximetry with fusinite: A new coal‐derived, particulate EPR probe
Vahidi, N., Clarkson, R. B., Liu, K. J., Norby, S. W., Wu, M., & Swartz, H. M. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310207 · Cited by 93
In vivo Oximetry Using EPR and India Ink
Goda, F., Liu, K. J., Walczak, T., O'Hara, J. A., Jiang, J., & Swartz, H. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330214 · Cited by 79
Ilangovan, G., Zweier, J. L., & Kuppusamy, P. (2000) · The Journal of Physical Chemistry B · doi:10.1021/jp9935182 · Cited by 72
Self-citationWilliams, B. B., Al‐Hallaq, H., Chandramouli, G. V. R., Barth, E. D., Rivers, J. N., Lewis, M. Z., Galtsev, V. E., Karczmar, G. S., & Halpern, H. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10089 · Cited by 67
Development of a Highly Sensitive Probe for Measuring Oxygen in Biological Tissues
Zweier, J. L., Chzhan, M., Ewert, U., Schneider, G., & Kuppusamy, P. (1994) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1994.1099 · Cited by 67
Self-citationKim, J. G., Zhao, D., Song, Y., Constantinescu, A., Mason, R. P., & Liu, H. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1527049 · Cited by 66
A naphthalocyanine-based EPR probe for localized measurements of tissue oxygenation
Ilangovan, G., Manivannan, A., Li, H., Yanagi, H., Zweier, J. L., & Kuppusamy, P. (2002) · Free Radical Biology and Medicine · doi:10.1016/s0891-5849(01)00784-5 · Cited by 66
Self-citationTuretschek, K., Preda, A., Floyd, E., Shames, D. M., Novikov, V., Roberts, T. P. L., Wood, J. M., Fu, Y., Carter, W. O., & Brasch, R. C. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-1000-5 · Cited by 62
Effect of carbogen on tumor oxygenation: combined fluorine-19 and proton MRI measurements
Fan, X., River, J. N., Zamora, M. A., Al‐Hallaq, H., & Karczmar, G. S. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)03035-3 · Cited by 60
Bulte, J. W. M., Douglas, T., Witwer, B. P., Zhang, S., Lewis, B. K., van Gelderen, P., Zywicke, H. A., Duncan, I. D., & Frank, J. A. (2002) · Academic Radiology · doi:10.1016/s1076-6332(03)80221-0 · Cited by 56
James, P. E., Grinberg, O. Y., Goda, F., Panz, T., O’Hara, J. A., & Swartz, H. M. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380109 · Cited by 55
Preparation and EPR Studies of Lithium Phthalocyanine Radical as an Oxymetric Probe
Afeworki, M., Miller, N. R., Devasahayam, N., Cook, J. A., Mitchell, J. B., Subramanian, S., & Krishna, M. C. (1998) · Free Radical Biology and Medicine · doi:10.1016/s0891-5849(98)00039-2 · Cited by 53
Laukemper‐Ostendorf, S., Scholz, A., Bürger, K., Heußel, C. P., Schmittner, M. D., Weiler, N., Markstaller, K., Eberle, B., Kauczor, H., Quintel, M., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10008 · Cited by 52
Ilangovan, G., Li, H., Zweier, J. L., & Kuppusamy, P. (2001) · The Journal of Physical Chemistry B · doi:10.1021/jp010130+ · Cited by 51
Self-citationIlangovan, G., Zweier, J. L., & Kuppusamy, P. (2000) · The Journal of Physical Chemistry B · doi:10.1021/jp0013863 · Cited by 44
Self-citationRuehm, S. G., Corot, C., VOGT, P. R., Cristina, H., & Debatin, J. F. (2002) · Academic Radiology · doi:10.1016/s1076-6332(03)80422-1 · Cited by 42
Hemoglobin Solutions and Tissue Oxygenation
Muir, W. W., & Wellman, M. L. (2003) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.2003.tb02423.x · Cited by 42
Gallez, B., Debuyst, R., Dejehet, F., Liu, K. J., Walczak, T., Goda, F., Demeure, R., Taper, H., & Swartz, H. M. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400120 · Cited by 41
Gallez, B., Jordan, B. F., & Baudelet, C. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199907)42:1<193::aid-mrm25>3.0.co;2-c · Cited by 34
Mechanism of Oxygen Response in Carbon-Based Sensors
Atsarkin, V. A., Demidov, V. V., Vasneva, G. A., Джепаров, Ф. С., Ceroke, P. J., Odintsov, B. M., & Clarkson, R. B. (2001) · Journal of Magnetic Resonance · doi:10.1006/jmre.2000.2274 · Cited by 33
Use of epr oximetry with india ink to measure the po2 in the liver in vivo in mice
Nakashima, T., Goda, F., Jiang, J., Shima, T., & Swartz, H. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340614 · Cited by 31
Aboagye, E. O., Maxwell, R. J., Horsman, M. R., Lewis, A., Workman, P., Tracy, M., & Griffiths, J. R. (1998) · British Journal of Cancer · doi:10.1038/bjc.1998.10 · Cited by 29
He, J., Beghein, N., Ceroke, P. J., Clarkson, R. B., Swartz, H. M., & Gallez, B. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1234 · Cited by 28
He, J., Beghein, N., Clarkson, R. B., Swartz, H. M., & Gallez, B. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/12/317 · Cited by 18
Manivannan, A., Yanagi, H., Ilangovan, G., & Kuppusamy, P. (2001) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(01)00310-9 · Cited by 18
Self-citationLiu, K. J., Miyake, M., James, P. E., & Swartz, H. M. (1998) · Journal of Magnetic Resonance · doi:10.1006/jmre.1998.1480 · Cited by 13
Cited by
Yamamori, T., Yasui, H., Yamazumi, M., Wada, Y., Nakamura, Y., Nakamura, H., & Inanami, O. (2012) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2012.04.033 · Cited by 396
Keeley, T. P., & Mann, G. E. (2019) · Physiological Reviews · doi:10.1152/physrev.00041.2017 · Cited by 329
Selective Inhibition of Hypoxia-Inducible Factor 1α Ameliorates Adipose Tissue Dysfunction
Sun, K., Halberg, N., Khan, M., Magalang, U. J., & Scherer, P. E. (2013) · Molecular and Cellular Biology · doi:10.1128/mcb.00951-12 · Cited by 231
“probe to oxygen was calibrated as described previously (43).”
MethodAssessment of tumor oxygenation by electron paramagnetic resonance: principles and applications
Gallez, B., Baudelet, C., & Jordan, B. F. (2004) · NMR in Biomedicine · doi:10.1002/nbm.900 · Cited by 222
“In several studies, measurements of tumor oxygenation using EPR have been carried out as a proof of principle in order to show that a specific method or a newly developed paramagnetic material was applicable for this purpose.(119,183,160,214,221,222) In other studies, EPR oximetry was compared with other methods that…”
Injectable, rapid gelling and highly flexible hydrogel composites as growth factor and cell carriers
Wang, F., Li, Z., Khan, M., Tamama, K., Kuppusamy, P., Wagner, W. R., Sen, C. K., & Guan, J. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.12.011 · Cited by 188
Self-citation
Metadata
- Authors
- Pandian, R. P., Parinandi, N. L., Ilangovan, G., Zweier, J. L., & Kuppusamy, P.
- Affiliations
- The Ohio State University (US)
- Corresponding author
- Kuppusamy, Periannan
- Venue
- Free Radical Biology and Medicine
- Publisher
- Elsevier BV
- Published
- 2003-11
- Volume
- 35
- Issue
- 9
- Pages
- 1138-1148
- ISSN
- 0891-5849 (ISSN-L)
- OpenAlex
- W1989313199
- Cited by
- 150
- References
- 44
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 6 · 2023: 2 · 2022: 1 · 2021: 5 · 2020: 3 · 2019: 9 · 2018: 11 · 2017: 8 · 2016: 6 · 2015: 5 · 2014: 5 · 2013: 8 · 2012: 7
- FWCI
- 4.16
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Free Radical Biology and Medicine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health
- National Cancer Institute (R01CA078886, CA78886)
- National Institute of Biomedical Imaging and Bioengineering (EB 00306, R01EB000306)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Electron Spin Resonance Studies
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Toxicology › Bioactive Compounds and Antitumor Agents
- Keywords
- oxygen sensing, oximetry, exchange narrowing, EPR linewidth, tumor hypoxia, arterial smooth muscle cells, cellular internalization
- MeSH terms
- Animals, Electron Spin Resonance Spectroscopy, Female, Fibrosarcoma, Gamma Rays, Humans, Hydrogen-Ion Concentration, Mice, Inbred C3H, Neoplasm Transplantation, Oxidation-Reduction, Oxygen, Porphyrins, Spin Labels, Temperature, Time Factors, Molecular Structure, Myocytes, Smooth Muscle, Cell Line, Tumor, Mice
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.