Reagentless glucose biosensor based on direct electron transfer of glucose oxidase immobilized on colloidal gold modified carbon paste electrode
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laviron, E. (1979) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/s0022-0728(79)80075-3 · Cited by 7,234
Ferrocene-mediated enzyme electrode for amperometric determination of glucose
Cass, A. E. G., Davis, G., Francis, G. D., Hill, H. A. O., Aston, W. J., Higgins, I. J., Plotkin, E. V., Scott, L. D. L., & Turner, A. P. F. (1984) · Analytical Chemistry · doi:10.1021/ac00268a018 · Cited by 1,646
Physical Chemistry: Principles and Applications in Biological Sciences
Tinoco, I. (1978) · Cited by 461
Morphology-Dependent Electrochemistry of Cytochrome c at Au Colloid-Modified SnO2 Electrodes
Brown, K. R., Fox, A. P., & Natan, M. J. (1996) · Journal of the American Chemical Society · doi:10.1021/ja952951w · Cited by 374
Direct electron transfer at horseradish peroxidase—colloidal gold modified electrodes
Zhao, J., Henkens, R. W., Stonehuerner, J., O'Daly, J. P., & Crumbliss, A. L. (1992) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(92)80140-y · Cited by 293
Liu, S.-Q., & Ju, H.-X. (2002) · Analytical Biochemistry · doi:10.1016/s0003-2697(02)00014-3 · Cited by 273
Self-citationEnzyme microsensor for glucose with an electrochemically synthesized enzyme-polyaniline film
Shinohara, H., Chiba, T., & Aizawa, M. (1988) · Sensors and Actuators · doi:10.1016/0250-6874(88)85031-5 · Cited by 249
Highly Selective Membrane-Free, Mediator-Free Glucose Biosensor
Wang, J., Liu, J., Chen, L., & Lu, F. (1994) · Analytical Chemistry · doi:10.1021/ac00093a011 · Cited by 174
Garjonyte, R., & Malinauskas, A. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00101-9 · Cited by 165
Oxidation of glucose oxidase from Penicillium vitale by one- and two-electron acceptors
Kulys, J. J., & Čénas, N. K. (1983) · Biochimica et Biophysica Acta (BBA) - Protein Structure and Molecular Enzymology · doi:10.1016/0167-4838(83)90340-0 · Cited by 161
Cited by
Gold Nanoparticles in Chemical and Biological Sensing
Saha, K., Agasti, S. S., Kim, C., Li, X., & Rotello, V. M. (2012) · Chemical Reviews · doi:10.1021/cr2001178 · Cited by 4,620
Integrated Nanoparticle–Biomolecule Hybrid Systems: Synthesis, Properties, and Applications
Katz, E., & Willner, I. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200400651 · Cited by 2,450
Glucose Oxidase–graphene–chitosan modified electrode for direct electrochemistry and glucose sensing
Kang, X., Wang, J., Wu, H., Aksay, I. A., Liu, J., & Lin, Y. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.09.004 · Cited by 1,229
Gold nanoparticle-based electrochemical biosensors
Pingarrón, J. M., Yáñez-Sedeño, P., & González-Cortés, A. (2008) · Electrochimica Acta · doi:10.1016/j.electacta.2008.03.005 · Cited by 965
A Comprehensive Review of Glucose Biosensors Based on Nanostructured Metal-Oxides
Rahman, M. M., Ahammad, A. J. S., Jin, J.-H., Ahn, S. J., & Lee, J.-J. (2010) · Sensors · doi:10.3390/s100504855 · Cited by 762
“The improved sensing performance by the direct electron transfer has been realized by incorporating the enzyme with metal nanoparticles [64,65], and semiconductive nanomaterials [66,67].”
MethodThe use of nanoparticles in electroanalysis: a review
Welch, C. M., & Compton, R. G. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-0230-3 · Cited by 759
Synthesis and electrochemical applications of gold nanoparticles
Guo, S., & Wang, E. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.07.054 · Cited by 693
Charge Transport in Nanoparticle Assemblies
Zabet-Khosousi, A., & Dhirani, A.-A. (2008) · Chemical Reviews · doi:10.1021/cr0680134 · Cited by 503
Putzbach, W., & Ronkainen, N. (2013) · Sensors · doi:10.3390/s130404811 · Cited by 502
New Nanostructured TiO2 for Direct Electrochemistry and Glucose Sensor Applications
Bao, S., Li, C. M., Zang, J., Cui, X., Qiao, Y., & Guo, J. (2008) · Advanced Functional Materials · doi:10.1002/adfm.200700728 · Cited by 446
Razmi, H., & Mohammad-Rezaei, R. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.09.009 · Cited by 325
Kong, T., Chen, Y., Ye, Y., Zhang, K., Wang, Z., & Wang, X. (2009) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.01.002 · Cited by 319
Zhang, S., Wang, N., Yu, H., Niu, Y., & Sun, C. (2005) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2004.12.002 · Cited by 317
Development of a tyrosinase biosensor based on gold nanoparticles-modified glassy carbon electrodes
Carralero Sanz, V., Mena, M. L., González-Cortés, A., Yáñez-Sedeño, P., & Pingarrón, J. M. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.10.007 · Cited by 312
Nanostructured FeS as a Mimic Peroxidase for Biocatalysis and Biosensing
Dai, Z., Liu, S., Bao, J., & Ju, H. (2009) · Chemistry – A European Journal · doi:10.1002/chem.200802158 · Cited by 312
Self-citationWang, Z., Liu, S., Wu, P., & Cai, C. (2009) · Analytical Chemistry · doi:10.1021/ac802421h · Cited by 307
Self-citationLim, S. H., Wei, J., Lin, J., Li, Q., & KuaYou, J. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.08.005 · Cited by 303
Feng, J.-J., Zhao, G., Xu, J.-J., & Chen, H.-Y. (2005) · Analytical Biochemistry · doi:10.1016/j.ab.2005.04.040 · Cited by 269
Nanotechnology in glucose monitoring: Advances and challenges in the last 10 years
Scognamiglio, V. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.02.043 · Cited by 266
Katz, E., & Willner, I. (2004) · Angewandte Chemie · doi:10.1002/ange.200400651 · Cited by 260
Deng, C., Chen, J., Chen, X., Xiao, C., Nie, L., & Yao, S. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.11.009 · Cited by 257
Deng, S., Jian, G., Lei, J., Hu, Z., & Ju, H. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.07.016 · Cited by 256
Self-citationWu, P., Shao, Q., Hu, Y., Jin, J., Yin, Y., Zhang, H., & Cai, C. (2010) · Electrochimica Acta · doi:10.1016/j.electacta.2010.07.079 · Cited by 254
Yu, Y., Chen, Z., He, S., Zhang, B., Li, X., & Yao, M. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.08.043 · Cited by 228
“The electrocatalytic process can be expressed as follows (Liu and Ju, 2003): GODðFADÞþ2e þ2Hþ⇋ GODðFADH2Þ ð2Þ GODðFADH2ÞþO2-GODðFADÞþH2O2 ð3Þ In this EC catalytic process (Bard and Faulkner, 2001), the oxidized form (FAD) was regenerated at the surface of the electrode and enhanced the reduction…”
Si, P., Ding, S., Yuan, J., Lou, X. W. (., & Kim, D.-H. (2011) · ACS Nano · doi:10.1021/nn202714c · Cited by 226
“4 V in the absence of glucose (Figure 7a), arising from the electrocatalytic reduction of the dissolved oxygen by the GOx/1DHS TiO2/Nafion-modified electrode.(29,70) However, the reductive current at the FAD redox potential gradually decreases with in-”
BackgroundWang, K., Liu, Q., Guan, Q.-M., Wu, J., Li, H.-N., & Yan, J.-J. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.09.043 · Cited by 216
Gold nanoparticle-based electrochemical biosensors
Yáñez-Sedeño, P., & Pingarrón, J. M. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-3221-5 · Cited by 211
Zhang, Q., Wu, S., Zhang, L., Lu, J., Verproot, F., Liu, Y., Xing, Z., Li, J., & Song, X.-M. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.11.024 · Cited by 208
Drug Delivery Nanoparticles Formulation and Characterization
(2016) · CRC Press eBooks · doi:10.3109/9781420078053 · Cited by 205
Tailoring Zinc Oxide Nanowires for High Performance Amperometric Glucose Sensor
Zang, J., Li, C. M., Cui, X., Wang, J., Sun, X., Dong, H., & Sun, C. Q. (2007) · Electroanalysis · doi:10.1002/elan.200603808 · Cited by 204
Wearable Biofuel Cells: A Review
Bandodkar, A. J., & Wang, J. (2016) · Electroanalysis · doi:10.1002/elan.201600019 · Cited by 193
Prospects of Nanomaterials in Biosensors
Pandey, P., Datta, M., & Malhotra, B. D. (2008) · Analytical Letters · doi:10.1080/00032710701792620 · Cited by 193
Immobilization technology: a sustainable solution for biofuel cell design
Yang, X.-Y., Tian, G., Jiang, N., & Su, B.-L. (2012) · Energy Environ. Sci. · doi:10.1039/c1ee02391h · Cited by 193
Xu, Q., Gu, S.-X., Jin, L., Zhou, Y.-E., Yang, Z., Wang, W., & Hu, X. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.09.049 · Cited by 193
Munje, R. D., Muthukumar, S., & Prasad, S. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.07.088 · Cited by 190
Wu, S., Ju, H. X., & Liu, Y. (2007) · Advanced Functional Materials · doi:10.1002/adfm.200600491 · Cited by 187
Self-citationMena, M. L., Yáñez-Sedeño, P., & Pingarrón, J. M. (2005) · Analytical Biochemistry · doi:10.1016/j.ab.2004.07.038 · Cited by 179
Wang, Y., Wang, X., Lu, W., Yuan, Q., Zheng, Y., & Yao, B. (2019) · Talanta · doi:10.1016/j.talanta.2019.01.104 · Cited by 166
Lin, J., He, C., Zhang, L., & Zhang, S. (2009) · Analytical Biochemistry · doi:10.1016/j.ab.2008.09.033 · Cited by 166
Yang, Y., Yang, H., Yang, M., liu, Y., Shen, G., & Yu, R. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.07.071 · Cited by 162
Patil, S. D., Papadimitrakopoulos, F., & Burgess, D. J. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.887 · Cited by 135
Dai, H., Zhong, Y., Wu, X., Hu, R., Wang, L., Zhang, Y., Fan, G., Hu, X., Li, J., & Yang, Z. (2018) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2017.12.077 · Cited by 44
Metadata
- Authors
- Liu, S., & Ju, H.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2003-11
- Volume
- 19
- Issue
- 3
- Pages
- 177-183
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2112503818
- Cited by
- 471
- References
- 14
- FWCI
- 15.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.