Cited by 135Hydrogels: synthesis, properties, applicationsAdvanced Drug Delivery SystemsWound Healing and Treatments

Dexamethasone-Loaded Poly(Lactic-Co-Glycolic) Acid Microspheres/Poly(Vinyl Alcohol) Hydrogel Composite Coatings for Inflammation Control

Patil, Siddhesh D., Papadimitrakopoulos, Fotios, Burgess, Diane J.·2004·Diabetes Technology & Therapeutics

Abstract

BACKGROUND: Successful performance of implantable glucose biosensors for metabolic monitoring is dependent on tissue compatibility. Negative immunostimulatory tissue reactions that occur due to implantation-induced tissue injury and the prolonged presence of such sensors can lead to a loss of functionality and device failure. The use of novel poly(lactic-co-glycolic) acid (PLGA) microsphere/poly(vinyl alcohol) (PVA) hydrogel composite coatings for implantable biosensors to control localized inflammation and fibrosis at the sensor/tissue interface is reported. METHODS: Dexamethasone-loaded PLGA microspheres were prepared using a solvent evaporation technique. Composites were fabricated by dispersing microspheres in PVA solution and performing freeze-thaw cycling. Composites were implanted into subcutaneous tissue of rats. In vitro and in vivo drug release kinetics were studied. Immunostimulatory response was determined through histopathological evaluation of excised tissue. RESULTS: PLGA microsphere/PVA hydrogel composites achieved localized dexamethasone delivery with approximate zero-order release kinetics. A linear level A in vitro-in vivo correlation was observed (R2 = 0.97). Dexamethasone released at a steady rate of 0.17 microg/day was sufficient to control acute and chronic inflammation as well as fibrosis. Implantation of composites containing no drug led to significant infiltration of inflammation-mediating cells at the implant site characteristic of acute inflammation followed by proliferation of a fibrotic band surrounding the implant by week 3. CONCLUSIONS: PLGA microsphere/PVA hydrogel composites eluting dexamethasone were successful in controlling negative tissue reactions at the sensor-tissue interface by reducing the level of inflammation-mediation cells to those observed in normal tissue. These composites show promise as coatings for implantable biosensors to improve biocompatibility and prolong sensor lifetime.

Integrity signals

Registry

Crossref · 10.1089/dia.2004.6.887

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Dexamethasone-releasing composites still exhibited reduced inflammation and fibrosis compared to control hydrogels at about 3 weeks, demonstrating that local dexamethasone release can arrest fibrous encapsulation.

    “As chronic inflammation set in at ~3 weeks, the DX-releasing composites still exhibited reduced inflammation and fibrosis compared to control hydrogels, demonstrating the ability of local DX release to arrest fibrous encapsulation.188”
  • Dexamethasone release reduced the inflammatory response by about 50% at 3 and 7 days compared to control PLGA/PVA hydrogel composites.

    “The release of DX reduced the inflammatory response by ~50% at 3 and 7 d compared to control PLGA/PVA hydrogel composites.188”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Patil, S. D., Papadimitrakopoulos, F., & Burgess, D. J.
Affiliations
University of Connecticut (US)
Venue
Diabetes Technology & Therapeutics
Published
2004-12
Volume
6
Issue
6
Pages
887-897
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2094159150
Cited by
135
References
31
Citations by year
2026: 1 · 2025: 4 · 2024: 1 · 2023: 4 · 2022: 2 · 2021: 1 · 2020: 6 · 2019: 8 · 2018: 8 · 2017: 8 · 2016: 7 · 2015: 11 · 2014: 8 · 2013: 5 · 2012: 13
FWCI
2.57
Type
journal article
Language
en
Open access
closed
Locations
  • Diabetes Technology & Therapeutics (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Medicine › Hydrogels: synthesis, properties, applications
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advanced Drug Delivery Systems
  • Health Sciences › Medicine › Rehabilitation › Wound Healing and Treatments
Keywords
dexamethasone, PLGA microspheres, polyvinyl alcohol hydrogel, composite coatings, inflammation control, fibrosis, sustained drug release, biocompatibility, in vitro-in vivo correlation
MeSH terms
Polylactic Acid-Polyglycolic Acid Copolymer, Animals, Anti-Inflammatory Agents, Non-Steroidal, Dexamethasone, Microspheres, Polyglycolic Acid, Polymers, Polyvinyl Alcohol, United States, Drug Monitoring, Lactic Acid, Hydrogel, Polyethylene Glycol Dimethacrylate, Models, Animal, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review