Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review
The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Biosensors: fundamentals and applications
Turner, A. P. F., Karube, I., Wilson, G. S., & Worsfold, P. J. (1987) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)85361-1 · Cited by 1,320
The effect of water on enzyme action in organic media.
Zaks, A., & Klibanov, A. M. (1988) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)68435-2 · Cited by 925
The avidin-biotin complex in bioanalytical applications
Wilchek, M., & Bayer, E. A. (1988) · Analytical Biochemistry · doi:10.1016/0003-2697(88)90120-0 · Cited by 894
Immobilization of glucose oxidase in ferrocene-modified pyrrole polymers
Foulds, N. C., & Lowe, C. R. (1988) · Analytical Chemistry · doi:10.1021/ac00173a008 · Cited by 613
Protein-modified electrodes. The glucose oxidase/polypyrrole system
Umana, M., & Waller, J. (1986) · Analytical Chemistry · doi:10.1021/ac00127a018 · Cited by 588
Malitesta, C., Palmisano, F., Torsi, L., & Zambonin, P. G. (1990) · Analytical Chemistry · doi:10.1021/ac00223a016 · Cited by 570
Foulds, N. C., & Lowe, C. R. (1986) · Journal of the Chemical Society, Faraday Transactions 1: Physical Chemistry in Condensed Phases · doi:10.1039/f19868201259 · Cited by 532
A review of the immobilization of enzymes in electropolymerized films
Barlett, P. N., & Cooper, J. M. (1993) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(93)80001-x · Cited by 472
Synthesis of polymeric microcapsule arrays and their use for enzyme immobilization
Parthasarathy, R. V., & Martin, C. R. (1994) · Nature · doi:10.1038/369298a0 · Cited by 326
Pihel, K., Walker, Q. D., & Wightman, R. M. (1996) · Analytical Chemistry · doi:10.1021/ac960153y · Cited by 251
Enzyme microsensor for glucose with an electrochemically synthesized enzyme-polyaniline film
Shinohara, H., Chiba, T., & Aizawa, M. (1988) · Sensors and Actuators · doi:10.1016/0250-6874(88)85031-5 · Cited by 249
Electrochemical immobilisation of enzymes
Bartlett, P. N., & Whitaker, R. G. (1987) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(87)85081-7 · Cited by 248
Regioselective oxidation of phenols catalyzed by polyphenol oxidase in chloroform
Kazandjian, R. Z., & Klibanov, A. M. (1985) · Journal of the American Chemical Society · doi:10.1021/ja00305a020 · Cited by 246
Electrochemistry of the polypyrrole glucose oxidase electrode
Bélanger, D., Nadreau, J., & Fortier, G. (1989) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/0022-0728(89)87036-6 · Cited by 239
Livache, T., Roget, A., Dejean, E., Barthet, C., Bidan, G., & Teoule, R. (1994) · Nucleic Acids Research · doi:10.1093/nar/22.15.2915 · Cited by 198
Lowry, J. P., McAteer, K., El Atrash, S. S., Duff, A., & O'Neill, R. D. (1994) · Analytical Chemistry · doi:10.1021/ac00082a025 · Cited by 183
Conducting polymer based amperometric enzyme electrodes
Schuhmann, W. (1995) · Mikrochimica Acta · doi:10.1007/bf01248237 · Cited by 179
Polypyrrole DNA Chip on a Silicon Device: Example of Hepatitis C Virus Genotyping
Livache, T., Fouque, B., Roget, A., Marchand, J., Bidan, G., Téoule, R., & Mathis, G. (1998) · Analytical Biochemistry · doi:10.1006/abio.1997.2462 · Cited by 162
The determination of p-cresol in chloroform with an enzyme electrode used in the organic phase
Hall, G. F., Best, D. J., & Turner, A. P. F. (1988) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)81345-8 · Cited by 156
Bioelectrochemical responses of the polyaniline glucose oxidase electrode
Mu, S., Xue, H., & Bidong, Q. (1991) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(91)85487-a · Cited by 151
Cosnier, S., & Innocent, C. (1992) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(92)80195-a · Cited by 149
Self-citationPeroxidase-incorporated polypyrrole membrane electrodes
Tatsuma, T., Gondaira, M., & Watanabe, T. (1992) · Analytical Chemistry · doi:10.1021/ac00034a019 · Cited by 143
Yabuki, S., Shinohara, H., Ikariyama, Y., & Aizawa, M. (1990) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(90)85100-j · Cited by 137
A new conducting polymer-coated glucose sensor
Pandey, P. C. (1988) · Journal of the Chemical Society Faraday Transactions 1 Physical Chemistry in Condensed Phases · doi:10.1039/f19888402259 · Cited by 136
Schuhmann, W. W., Kranz, C., Huber, J., & Wohlschläger, H. (1993) · Synthetic Metals · doi:10.1016/0379-6779(93)91196-9 · Cited by 119
Cosnier, S., Innocent, C., & Jouanneau, Y. (1994) · Analytical Chemistry · doi:10.1021/ac00091a032 · Cited by 118
Self-citationSimultaneous immobilization of glucose oxidase and a mediator in conducting polymer films
Iwakura, C., Kajiya, Y., & Hiroshi Yoneyama, C. (1988) · Journal of the Chemical Society Chemical Communications · doi:10.1039/c39880001019 · Cited by 117
Hiller, M., Kranz, C., Huber, J., Bäuerle, P., & Schuhmann, W. W. (1996) · Advanced Materials · doi:10.1002/adma.19960080306 · Cited by 115
Bartlett, P., & Caruana, D. J. (1992) · The Analyst · doi:10.1039/an9921701287 · Cited by 109
Biosensors based on oxidases immobilized in various conducting polymers
Trojanowicz, M., Geschke, O., Krawczyk, T. K. V., & Cammann, K. (1995) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(95)01724-0 · Cited by 108
Electrochemical biosensors based on enzymes immobilized in electropolymerized films
Trojanowicz, M., & Krawczyk, T. K. V. (1995) · Microchimica Acta · doi:10.1007/bf01248249 · Cited by 100
Centonze, D., Guerrieri, A., Malitesta, C., Palmisano, F., & Zambonin, P. G. (1992) · Analytical and Bioanalytical Chemistry · doi:10.1007/bf00321865 · Cited by 97
Electro-conductive enzyme membrane
Yabuki, S., Shinohara, H., & Aizawa, M. (1989) · Journal of the Chemical Society Chemical Communications · doi:10.1039/c39890000945 · Cited by 88
Coche‐Guérente, L., Cosnier, S., Innocent, C., & Mailley, P. (1995) · Analytica Chimica Acta · doi:10.1016/0003-2670(95)00178-3 · Cited by 84
Self-citationKoopal, C. G. J., de Ruiter, B., & Nolte, R. J. M. (1991) · Journal of the Chemical Society Chemical Communications · doi:10.1039/c39910001691 · Cited by 80
Cosnier, S., Galland, B., & Innocent, C. (1997) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(97)00207-6 · Cited by 74
Self-citationCoche‐Guérente, L., Deronzier, A., Mailley, P., & Moutet, J. (1994) · Analytica Chimica Acta · doi:10.1016/0003-2670(94)80097-9 · Cited by 72
Poly(pyrrole–biotin): a new polymer for biomolecule grafting on electrode surfaces
Cosnier, S., & Lepellec, A. (1999) · Electrochimica Acta · doi:10.1016/s0013-4686(98)00294-1 · Cited by 71
Self-citationDeshpande, M. V., & Hall, E. A. H. (1990) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(90)80033-a · Cited by 69
Kranz, C., Wohlschläger, H., Schmidt, H., & Schuhmann, W. W. (1998) · Electroanalysis · doi:10.1002/(sici)1521-4109(199807)10:8<546::aid-elan546>3.0.co;2-# · Cited by 67
Cosnier, S., Lepellec, A., Guidetti, B., & Rico‐Lattes, I. (1998) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(98)00049-7 · Cited by 61
Self-citationRöckel, H., Huber, J., Gleiter, R., & Schuhmann, W. W. (1994) · Advanced Materials · doi:10.1002/adma.19940060708 · Cited by 60
Tatsuma, T., Watanabe, T., & Watanabe, T. (1993) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(93)80523-k · Cited by 58
An enzyme switch sensitive to NADH
Matsue, T., Nishizawa, M., Sawaguchi, T., & Uchida, I. (1991) · Journal of the Chemical Society Chemical Communications · doi:10.1039/c39910001029 · Cited by 57
Mesoporous TiO2 films: New catalytic electrode fabricating amperometric biosensors based on oxidases
Cosnier, S., Gondran, C., Senillou, A., Grätzel, M., & Vlachopoulos, N. (1997) · Electroanalysis · doi:10.1002/elan.1140091803 · Cited by 55
Self-citationPermselective lipidpoly(o-phenylenediamine) coatings for amperometric biosensing of glucose
Wang, J., & Wu, H. (1993) · Analytica Chimica Acta · doi:10.1016/0003-2670(93)85282-o · Cited by 43
Enzyme Electrode Biosensors: Theory and Applications
Kauffmann, J., & Guilbault, G. G. (1992) · Methods of biochemical analysis · doi:10.1002/9780470110577.ch3 · Cited by 37
Chemical sensors based on ultrathin-film composite membranes - a new concept in sensor design
Ballarin, B., Brumlik, C. J., Lawson, D. R., Liang, W., Dyke, L. S. V., & Martin, C. R. (1992) · Analytical Chemistry · doi:10.1021/ac00045a032 · Cited by 37
Detection of Galactose and Lactose by a Poly(Amphiphilic Pyrrole)-Galactose Oxidase Electrode
Cosnier, S., & Innocent, C. (1994) · Analytical Letters · doi:10.1080/00032719408006380 · Cited by 36
Self-citationAn Integrated Needle-Type Biosensor for Intravascular Glucose and Lactate Monitoring
Yang, Q., Atanasov, P., & Wilkins, E. S. (1998) · Electroanalysis · doi:10.1002/(sici)1521-4109(199809)10:11<752::aid-elan752>3.0.co;2-t · Cited by 34
Microstructured Peptide‐Functionalised Surfaces by Electrochemical Polymerisation
Heiduschka, P., Göpel, W., Beck, W., Kraas, W., Kienle, S., & Jung, G. (1996) · Chemistry - A European Journal · doi:10.1002/chem.19960020610 · Cited by 33
Biotin-Modified Surfaces by Electrochemical Polymerizationof Biotinyl-Tyramide
Yang, S.-T., Witkowski, A., Hutchins, R. S., Scott, D. L., & Bachas, L. G. (1998) · Electroanalysis · doi:10.1002/(sici)1521-4109(199801)10:1 · Cited by 33
Investigation of viologen derivatives as electron-transfer mediators in amperometric glucose sensors
Hale, P. D., Boguslavsky, L. I., Karan, H. I., Lan, H. L., Lee, H. S., Okamoto, Y., & Skotheim, T. A. (1991) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)80879-x · Cited by 32
Recycling Systems Based on Screen-Printed Electrodes
Lisdat, F., Ho, W. O., Wollenberger, U., Scheller, F. W., Richter, T., & Bilitewski, U. (1998) · Electroanalysis · doi:10.1002/(sici)1521-4109(199809)10:12<808::aid-elan808>3.0.co;2-k · Cited by 29
A Poly(amphiphilic pyrrole)−Flavin Reductase Electrode for Amperometric Determination of Flavins
Cosnier, S., Fontecave, M., Lìmosin, D., & Nivière, V. (1997) · Analytical Chemistry · doi:10.1021/ac961041+ · Cited by 26
Self-citationCentonze, D., Guerrieri, A., Palmisano, F., Torsi, L., & Zambonin, P. G. (1994) · Analytical and Bioanalytical Chemistry · doi:10.1007/bf00323981 · Cited by 25
Poly (Amphiphilic Pyrr0Le)-PPO Electrodes for Organic-Phase Enzymatic Assay
Coche‐Guérente, L., Cosnier, S., & Innocent, C. (1995) · Analytical Letters · doi:10.1080/00032719508002675 · Cited by 20
Self-citation
Cited by
Conductive polymers: Towards a smart biomaterial for tissue engineering
Balint, R., Cassidy, N. J., & Cartmell, S. H. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.02.015 · Cited by 1,777
Application of conducting polymers to biosensors
Gerard, M. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00312-8 · Cited by 1,652
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
Biofuel cells and their development
Bullen, R. A., Arnot, T. C., Lakeman, J. B., & Walsh, F. C. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.01.030 · Cited by 1,011
Sensor and biosensor preparation, optimisation and applications of Prussian Blue modified electrodes
Ricci, F., & Palleschi, G. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.001 · Cited by 781
“…involve the loss of oneq f the i - s ic v ide t ar the e er, in d rted t the “ lity a sults i reserv the h hyp roof, i ible f that t ateria n ( h lkal here w olym also b B. ers h elopm ment a tec- tion of the protein and mediator molecules (Gerard et al., 2002; Cosnier, 1999; Lewis et al., 1999).”
Metadata
- Authors
- Cosnier, S.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 1999-05
- Volume
- 14
- Issue
- 5
- Pages
- 443-456
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2064175091
- Cited by
- 768
- References
- 58
- FWCI
- 7.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.