High-throughput and ultra-high-throughput screening: solution- and cell-based approaches
The DOI matches its Crossref record; 58 of the 60 references it cites were found in a registry or an index.
Abstract
The trend towards assay miniaturization for high-throughput and ultra-high-throughput screening continues to spur development of homogeneous, fluorescence-based assays in higher density, smaller volume microplate formats. Recently, first-generation microfluidic devices have been designed for performing continuous-flow biochemical and cell-based assays. These devices provide orders-of-magnitude reduction in reagent consumption, and offer the potential for implementing high-throughput screening in formats that integrate up-front compound handling with unique assay functionality.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Rapid evaporation in microtiter plates is an acknowledged issue [41, 42].”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [41]
Citations
Cites
Fluorescence Energy Transfer as a Spectroscopic Ruler
Stryer, L. (1978) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.47.070178.004131 · Cited by 2,406
Transport, Manipulation, and Reaction of Biological Cells On-Chip Using Electrokinetic Effects
Li, P. C. H., & Harrison, D. J. (1997) · Analytical Chemistry · doi:10.1021/ac9606564 · Cited by 422
A dual-luciferase reporter system for studying recoding signals.
Grentzmann, G., Ingram, J. A., Kelly, P. J., Gesteland, R. F., & Atkins, J. F. (1998) · PubMed · Cited by 406
Chiem, N., & Harrison, D. J. (1997) · Analytical Chemistry · doi:10.1021/ac9606620 · Cited by 397
Microchip Device for Performing Enzyme Assays
Hadd, A. G., Raymond, D. E., Halliwell, J. W., Jacobson, S. C., & Ramsey, J. M. (1997) · Analytical Chemistry · doi:10.1021/ac970192p · Cited by 383
Mathis, G. (1995) · Clinical Chemistry · doi:10.1093/clinchem/41.9.1391 · Cited by 339
A review of recent trends in analytical applications of electrogenerated chemiluminescence
Knight, A. (1999) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(98)00086-7 · Cited by 329
Rapid screening of environmental chemicals for estrogen receptor binding capacity.
Bolger, R., Wiese, T. E., Ervin, K., Nestich, S., & Checovich, W. (1998) · Environmental Health Perspectives · doi:10.1289/ehp.98106551 · Cited by 316
Chiem, N. H., & Harrison, D. J. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.3.591 · Cited by 264
Fluorescence correlation spectroscopy: lead discovery by miniaturized HTS
Auer, M., Moore, K. J. M., Meyer‐Almes, F., Guenther, R., Pope, A. J., & Stoeckli, K. A. (1998) · Drug Discovery Today · doi:10.1016/s1359-6446(98)01240-9 · Cited by 241
Bosworth, N., & Towers, P. (1989) · Nature · doi:10.1038/341167a0 · Cited by 219
Microfluidic Assays of Acetylcholinesterase Inhibitors
Hadd, A. G., Jacobson, S. C., & Ramsey, J. M. (1999) · Analytical Chemistry · doi:10.1021/ac990591f · Cited by 193
Cell-based assays and instrumentation for screening ion-channel targets
González, J. (1999) · Drug Discovery Today · doi:10.1016/s1359-6446(99)01383-5 · Cited by 178
A Microchip-Based Enzyme Assay for Protein Kinase A
Cohen, C. B., Chin-Dixon, E., Jeong, S., & Nikiforov, T. T. (1999) · Analytical Biochemistry · doi:10.1006/abio.1999.4204 · Cited by 168
[12] Fluorescence anisotropy applied to biomolecular interactions
Jameson, D. M., & Sawyer, W. H. (1995) · Methods in Enzymology · doi:10.1016/0076-6879(95)46014-4 · Cited by 164
High-throughput screening: advances in assay technologies
Sittampalam, G. S., Kahl, S. D., & Janzen, W. P. (1997) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(97)80078-6 · Cited by 158
Koltermann, A., Kettling, U., Bieschke, J., Winkler, T., & Eigen, M. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.4.1421 · Cited by 155
Fluorescence Polarization: An Analytical Tool for Immunoassay and_ Drug Discovery
Nasir, M. S., & Jolley, M. E. (1999) · Combinatorial Chemistry & High Throughput Screening · doi:10.2174/1386207302666220204192916 · Cited by 145
Chemiluminescence and bioluminescence
Kricka, L. J. (1995) · Analytical Chemistry · doi:10.1021/ac00108a035 · Cited by 114
Miniaturized FRET assays and microfluidics: key components for ultra-high-throughput screening
Mere, L. (1999) · Drug Discovery Today · doi:10.1016/s1359-6446(99)01377-x · Cited by 114
Miniaturization technologies in HTS: how fast, how small, how soon?
Burbaum, J. J. (1998) · Drug Discovery Today · doi:10.1016/s1359-6446(98)01203-3 · Cited by 109
HTS approaches to voltage-gated ion channel drug discovery
Denyer, J. C., Worley, J. F., Cox, B. J., Allenby, G., & Banks, M. N. (1998) · Drug Discovery Today · doi:10.1016/s1359-6446(98)01199-4 · Cited by 103
A Fluorescence Polarization Competition Immunoassay for Tyrosine Kinases
Seethala, R., & Menzel, R. (1998) · Analytical Biochemistry · doi:10.1006/abio.1997.2455 · Cited by 91
Conway, B. R., Minor, L. K., Xu, J., Gunnet, J. W., DeBiasio, R. L., D’Andrea, M. R., Rubin, R., DeBiasio, R., Giuliano, K., Zhou, L., et al. (1999) · SLAS DISCOVERY · doi:10.1177/108705719900400207 · Cited by 80
Tyrosine kinase assays adapted to homogeneous time-resolved fluorescence
Kolb, A. J., Kaplita, P. V., Hayes, D. J., Park, Y.-W., Pernell, C., Major, J. S., & Mathis, G. (1998) · Drug Discovery Today · doi:10.1016/s1359-6446(98)01204-5 · Cited by 78
Oldenburg, K. R., Zhang, J.-H., Chen, T., Maffia, A., Blom, K. F., Combs, A. P., & Chung, T. D. Y. (1998) · SLAS Discovery · doi:10.1177/108705719800300108 · Cited by 74
Miraglia, S. J., Swartzman, E. E., Mellentin, J. D., Evangelista, L., Smith, C. J. S., Gunawan, I., Lohman, K. L., Goldberg, E. M., Manian, B. S., & Yuan, P.-M. (1999) · SLAS DISCOVERY · doi:10.1177/108705719900400407 · Cited by 66
Challenges and Opportunities in High Throughput Screening: Implications for New Technologies
Major, J. S. (1998) · SLAS DISCOVERY · doi:10.1177/108705719800300102 · Cited by 61
Maffia, A. M., Kariv, I., & Oldenburg, K. R. (1999) · SLAS DISCOVERY · doi:10.1177/108705719900400307 · Cited by 59
HOMOGENEOUS TIME-RESOLVED IL-2–IL-2Rα ASSAY USING FLUORESCENCE RESONANCE ENERGY TRANSFER
Stenroos, K., Hurskainen, P., Eriksson, S., Hemmilä, I. A., Blomberg, K. R., & Lindqvist, C. (1998) · Cytokine · doi:10.1006/cyto.1997.0321 · Cited by 58
Kariv, I., Stevens, M. E., Behrens, D. L., & Oldenburg, K. R. (1999) · SLAS DISCOVERY · doi:10.1177/108705719900400105 · Cited by 49
Chemiluminescence and Bioluminescence
Kricka, L. J. (1999) · Analytical Chemistry · doi:10.1021/a19999022 · Cited by 32
S′ subsite mapping of serine proteases based on fluorescence resonance energy transfer
Grahn, S., Kurth, T., Ullmann, D., & Jakubke, H. (1999) · Biochimica et Biophysica Acta (BBA) - Protein Structure and Molecular Enzymology · doi:10.1016/s0167-4838(99)00059-x · Cited by 31
Bedard, J., May, S., Barbeau, D. J., Yuen, L., Rando, R. F., & Bowlin, T. L. (1999) · Antiviral Research · doi:10.1016/s0166-3542(98)00061-8 · Cited by 31
Moore, K. J., Turconi, S., Miles-Williams, A., Djaballah, H., Hurskainen, P., Harrop, J., Murray, K. J., & Pope, A. J. (1999) · SLAS DISCOVERY · doi:10.1177/108705719900400408 · Cited by 30
A high throughput assay of the hepatitis C virus nonstructural protein 3 serine proteinase
Kakiuchi, N., Nishikawa, S., Hattori, M., & Shimotohno, K. (1999) · Journal of Virological Methods · doi:10.1016/s0166-0934(99)00034-8 · Cited by 29
Chemiluminescence imaging in bioanalysis
Pasini, P., Musiani, M., Russo, C., Valenti, P., Aicardi, G., Crabtree, J. E., Baraldini, M., & Roda, A. (1998) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/s0731-7085(98)00209-x · Cited by 27
High Throughput Scintillation Proximity Assay for the Identification of FKBP-12 Ligands
Graziani, F., Aldegheri, L., & Terstappen, G. C. (1999) · SLAS DISCOVERY · doi:10.1177/108705719900400102 · Cited by 22
Beyond the 96-Well Microplate: Instruments and Assay Methods for the 384-Well Format
Kolb, A. J., & Neumann, K. (1997) · SLAS DISCOVERY · doi:10.1177/108705719700200209 · Cited by 22
Abriola, L., Chin, M., Fuerst, P., Schweitzer, R. H., & Sills, M. A. (1999) · SLAS DISCOVERY · doi:10.1177/108705719900400305 · Cited by 21
Sharif, T. R., & Sharif, M. (1999) · International Journal of Oncology · doi:10.3892/ijo.14.2.327 · Cited by 21
What is the Future of High Throughput Screening?
Divers, M. (1999) · SLAS DISCOVERY · doi:10.1177/108705719900400403 · Cited by 21
Zysk, J. R., & Baumbach, W. R. (1997) · Combinatorial Chemistry & High Throughput Screening · doi:10.2174/1386207301666220125212451 · Cited by 21
Hill, D. C., Wrigley, S. K., & Nisbet, L. J. (2007) · Springer eBooks · doi:10.1007/bfb0102297 · Cited by 19
Calcium imaging with chemiluminescence
Créton, R., Kreiling, J. A., & Jaffe, L. F. (1999) · Microscopy Research and Technique · doi:10.1002/(sici)1097-0029(19990915)46:6<390::aid-jemt7>3.0.co;2-s · Cited by 19
A Melanophore-Based Screening Assay for Erythropoietin Receptors
Carrithers, M. D., Marotti, L. A., Yoshimura, A., & Lerner, M. R. (1999) · SLAS DISCOVERY · doi:10.1177/108705719900400103 · Cited by 17
Bossé, R., Garlick, R. K., Brown, B. A., & Ménard, L. (1998) · SLAS DISCOVERY · doi:10.1177/108705719800300407 · Cited by 17
A 384-HTS for Human Factor VIIa: Comparison With 96- and 864-Well Formats
Comley, J. C. W., Binnie, A. J., Bonk, C., & Houston, J. G. (1997) · SLAS DISCOVERY · doi:10.1177/108705719700200307 · Cited by 16
What is the Future of High Throughput Screening?
Stahl, W. (1999) · SLAS DISCOVERY · doi:10.1177/108705719900400303 · Cited by 15
High Throughput, Mechanism-Based Screening Techniques for Discovering Novel Agrochemicals
Walsh, J. C. (1998) · SLAS DISCOVERY · doi:10.1177/108705719800300303 · Cited by 14
Sharif, T. R., & Sharif, M. (1998) · International Journal of Oncology · doi:10.3892/ijo.13.4.685 · Cited by 13
Genetic Recombination as a Reporter for Screening Steroid Receptor Agonists and Antagonists
Dias, J., Go, N. F., Hart, C. P., & Mattheakis, L. C. (1998) · Analytical Biochemistry · doi:10.1006/abio.1998.2583 · Cited by 12
Zysk, & Baumbach, W. R. (1998) · PubMed · Cited by 11
What is the Future of High Throughput Screening?
Major, J. S. (1999) · SLAS DISCOVERY · doi:10.1177/108705719900400304 · Cited by 10
Biological cell assays on an electrokinetic microchip
Andersson, P. E., Li, P., Smith, R., Szarka, R. J., & Harrison, D. J. (2002) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.1997.635477 · Cited by 9
Screening for oligonucleotide binding affinity by a convenient fluorescence competition assay
Harrison, J. G., Liu, X., & Balasubramanian, S. (1999) · Nucleic Acids Research · doi:10.1093/nar/27.17.e14-i · Cited by 4
Screening for oligonucleotide binding affinity by a convenient fluorescence competition assay
Harrison, J. A. (1999) · Nucleic Acids Research · doi:10.1093/nar/27.17.e14 · Cited by 4
Synthesis Coupled to Scintillation Proximity Affinity Screening
Parandoosh, Z., Knowles, S. K., Xiao, X.-Y., Zhao, C., David, G. S., & Nova, M. P. (1998) · SLAS DISCOVERY · doi:10.1177/108705719800300408 · Cited by 3
Cited by
Lab-on-a-chip: microfluidics in drug discovery
Dittrich, P. S., & Manz, A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd1985 · Cited by 1,844
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Outlook for cellulase improvement: Screening and selection strategies
Percival Zhang, Y.-H., Himmel, M. E., & Mielenz, J. R. (2006) · Biotechnology Advances · doi:10.1016/j.biotechadv.2006.03.003 · Cited by 1,349
Target identification and mechanism of action in chemical biology and drug discovery
Schenone, M., Dančík, V., Wagner, B. K., & Clemons, P. A. (2013) · Nature Chemical Biology · doi:10.1038/nchembio.1199 · Cited by 1,096
Metadata
- Authors
- Sundberg, S.
- Corresponding author
- Sundberg, S
- Venue
- Current Opinion in Biotechnology
- Publisher
- Elsevier BV
- Published
- 2000-02-01
- Volume
- 11
- Issue
- 1
- Pages
- 47-53
- ISSN
- 0958-1669 (ISSN-L)
- OpenAlex
- W2097654801
- Cited by
- 455
- References
- 60
- Citations by year
- 2026: 4 · 2025: 6 · 2024: 6 · 2023: 14 · 2022: 10 · 2021: 6 · 2020: 11 · 2019: 8 · 2018: 16 · 2017: 23 · 2016: 16 · 2015: 19 · 2014: 15 · 2013: 24 · 2012: 25
- FWCI
- 3.83
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Current Opinion in Biotechnology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced Biosensing Techniques and Applications
- Keywords
- high-throughput screening, ultra-high-throughput screening, assay miniaturization, microfluidics, cell-based assays, reagent consumption reduction
- MeSH terms
- Animals, Biotechnology, Cells, Drug Evaluation, Preclinical, Enzymes, Fluorescence, Humans, Ligands, Microchemistry, Protein Binding, Solutions
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.