Effects of solvent on the maximum charge state and charge state distribution of protein ions produced by electrospray ionization
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
The effects of solvent composition on both the maximum charge states and charge state distributions of analyte ions formed by electrospray ionization were investigated using a quadrupole mass spectrometer. The charge state distributions of cytochrome c and myoglobin, formed from 47%/50%/3% water/solvent/acetic acid solutions, shift to lower charge (higher m/z) when the 50% solvent fraction is changed from water to methanol, to acetonitrile, to isopropanol. This is also the order of increasing gas-phase basicities of these solvents, although other physical properties of these solvents may also play a role. The effect is relatively small for these solvents, possibly due to their limited concentration inside the electrospray interface. In contrast, the addition of even small amounts of diethylamine (<0.4%) results in dramatic shifts to lower charge, presumably due to preferential proton transfer from the higher charge state ions to diethylamine. These results clearly show that the maximum charge states and charge state distributions of ions formed by electrospray ionization are influenced by solvents that are more volatile than water. Addition of even small amounts of two solvents that are less volatile than water, ethylene glycol and 2-methoxyethanol, also results in preferential deprotonation of higher charge state ions of small peptides, but these solvents actually produce an enhancement in the higher charge state ions for both cytochrome c and myoglobin. For instruments that have capabilities that improve with lower m/z, this effect could be taken advantage of to improve the performance of an analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
(2014) · doi:10.1201/b17118 · Cited by 57,706
CRC Handbook of Chemistry and Physics
P, D. (1992) · Journal of Molecular Structure · doi:10.1016/0022-2860(92)85083-s · Cited by 9,329
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Nist chemistry webbook, nist standard reference database number 69
Linstorm, P. (1998) · Medical Entomology and Zoology · Cited by 4,606
Analytical Properties of the Nanoelectrospray Ion Source
Wilm, M., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac9509519 · Cited by 1,868
Dole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
On the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
Ion Mobility Measurements and their Applications to Clusters and Biomolecules
Clemmer, D. E., & Jarrold, M. F. (1997) · Journal of Mass Spectrometry · doi:10.1002/(sici)1096-9888(199706)32:6<577::aid-jms530>3.0.co;2-4 · Cited by 741
Probing conformational changes in proteins by mass spectrometry
Chowdhury, S. K., Katta, V., & Chait, B. T. (1990) · Journal of the American Chemical Society · doi:10.1021/ja00180a074 · Cited by 646
Covey, T. R., Bonner, R. F., Shushan, B. I., Henion, J., & Boyd, R. K. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290021111 · Cited by 593
Ion formation from charged droplets: Roles of geometry, energy, and time
Fenn, J. B. (1993) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(93)85014-o · Cited by 518
Loo, J. A., Loo, R. R. O., Udseth, H. R., Edmonds, C. G., & Smith, R. D. (1991) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290050303 · Cited by 291
Schnier, P. D., Gross, D. S., & Williams, E. R. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00532-3 · Cited by 258
Self-citationPopovych, O., & Tomkins, R. P. T. (1981) · Cited by 221
Van Berkel, G. J., Zhou, F., & Aronson, J. T. (1997) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(96)04476-x · Cited by 201
Proton Transfer Reactivity of Large Multiply Charged Ions
Williams, E. R. (1996) · Journal of Mass Spectrometry · doi:10.1002/(sici)1096-9888(199608)31:8<831::aid-jms392>3.0.co;2-7 · Cited by 195
Self-citationLee, S.-W., Freivogel, P., Schindler, T., & Beauchamp, J. L. (1998) · Journal of the American Chemical Society · doi:10.1021/ja982075x · Cited by 174
Conformations and folding of lysozyme ions in vacuo.
Gross, D. S., Schnier, P. D., Rodriguez‐Cruz, S. E., Fagerquist, C. K., & Williams, E. R. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.7.3143 · Cited by 156
Self-citationElectrospray ionization mass spectrometry in the study of biomolecular non-covalent interactions
Veenstra, T. D. (1999) · Biophysical Chemistry · doi:10.1016/s0301-4622(99)00037-x · Cited by 149
Unit resolution mass spectra of 112 kDa molecules with 3 Da accuracy
Kelleher, N. L., Senko, M. W., Siegel, M. M., & McLafferty, F. W. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00060-3 · Cited by 122
Thermal denaturation of some proteins and its effect on their electrospray mass spectrat
Blanc, J. C. Y. L., Beuchemin, D., Siu, K. W. M., Guevremont, R., & Berman, S. S. (1991) · Organic Mass Spectrometry · doi:10.1002/oms.1210261005 · Cited by 86
Winger, B. E., Light-Wahl, K. J., & Smith, R. D. (1992) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(92)85003-3 · Cited by 85
Rodriguez‐Cruz, S. E., Klassen, J. S., & Williams, E. R. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00020-2 · Cited by 85
Self-citationHydration of gas-phase ions formed by electrospray ionization
Rodriguez‐Cruz, S. E., Klassen, J. S., & Williams, E. R. (1999) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00068-9 · Cited by 81
Self-citationLoo, R. R. O., Winger, B. E., & Smith, R. D. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)85067-4 · Cited by 61
Carbeck, J. D., Severs, J. C., Gao, J., Wu, Q., Smith, R. D., & Whitesides, G. M. (1998) · The Journal of Physical Chemistry B · doi:10.1021/jp980768u · Cited by 49
Camara, E., Green, M. K., Penn, S. G., & Lebrilla, C. B. (1996) · Journal of the American Chemical Society · doi:10.1021/ja960686o · Cited by 40
Apparent proton affinities of highly charged peptide ions
Sterner, J. L., Johnston, M. V., Nicol, G. R., & Ridge, D. P. (1999) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00020-3 · Cited by 20
Cited by
Banerjee, S., & Mazumdar, S. (2012) · International Journal of Analytical Chemistry · doi:10.1155/2012/282574 · Cited by 662
Protein identification methods in proteomics
Gevaert, K., & Vandekerckhove, J. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000401)21:6<1145::aid-elps1145>3.0.co;2-z · Cited by 338
Mechanism of Charging and Supercharging Molecules in Electrospray Ionization
Iavarone, A. T., & Williams, E. R. (2003) · Journal of the American Chemical Society · doi:10.1021/ja021202t · Cited by 324
Self-citationEstimates of Protein Surface Areas in Solution by Electrospray Ionization Mass Spectrometry
Kaltashov, I. A., & Mohimen, A. (2005) · Analytical Chemistry · doi:10.1021/ac050511+ · Cited by 319
Sze, S. K., Ge, Y., Oh, H., & McLafferty, F. W. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.251691898 · Cited by 250
Metadata
- Authors
- Iavarone, A. T., Jurchen, J. C., & Williams, E. R.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-11-01
- Volume
- 11
- Issue
- 11
- Pages
- 976-985
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W1973163422
- Cited by
- 199
- References
- 28
- FWCI
- 3.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).