Practical quantitative biomedical applications of MALDI-TOF mass spectrometry
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOFMS) is used to obtain fast and accurate determinations of molecular mass, but quantitative determinations are generally made by other techniques. In this study we illustrate the practical utility of automated MALDI-TOFMS as a tool for quantifying a diverse array of biomolecules covering an extensive molecular weight range, and present in biological extracts and fluids. Growth hormone was measured in rat pituitary tissue; insulin in human pancreatic tissue; homovanillic acid in human urine; and LVV-hemorphin-7, epinephrine and norepinephrine in human adrenal and pheochromocytoma tissues. Internal standards including compounds of similar molecular weight, structural analogs or isotopomers were incorporated into each analysis. We report on the current practical limitations of quantitative MALDI-TOFMS and highlight some of the potential benefits of this technique as a quantitative tool.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular Imaging of Biological Samples: Localization of Peptides and Proteins Using MALDI-TOF MS
Caprioli, R. M., Farmer, T. B., & Gile, J. (1997) · Analytical Chemistry · doi:10.1021/ac970888i · Cited by 2,234 · cited 1×
“Recently, applications of MALDI-TOFMS have been extended to include the direct analysis of biological tissues and single cell organisms with the aim of characterizing endogenous peptide and protein constituents [11–18].”
BackgroundStoeckli, M., Chaurand, P., Hallahan, D. E., & Caprioli, R. M. (2001) · Nature Medicine · doi:10.1038/86573 · Cited by 1,172 · cited 1×
“Recently, applications of MALDI-TOFMS have been extended to include the direct analysis of biological tissues and single cell organisms with the aim of characterizing endogenous peptide and protein constituents [11–18].”
BackgroundMatrix‐assisted laser desorption ionization mass spectrometry
Karas, M., Bahr, U., & Gießmann, U. (1991) · Mass Spectrometry Reviews · doi:10.1002/mas.1280100503 · Cited by 377
Mirgorodskaya, O. A., Kozmin, Y. P., Titov, M. I., K�rner, R., S�nksen, C. P., & Roepstorff, P. (2000) · Rapid Communications in Mass Spectrometry · doi:10.1002/1097-0231(20000730)14:14<1226::aid-rcm14>3.0.co;2-v · Cited by 368 · cited 1×
“Most of the studies to date have focused on the quantification of low mass analytes, in particular, alkaloids or active ingredients in agricultural or food products [40–45], whereas other studies have demonstrated the potential of MALDI-TOFMS for the quantification of biologically relevant analytes such as neuropeptid…”
BackgroundDirect Profiling of Proteins in Biological Tissue Sections by MALDI Mass Spectrometry
Chaurand, P., Stoeckli, M., & Caprioli, R. M. (1999) · Analytical Chemistry · doi:10.1021/ac990781q · Cited by 282 · cited 1×
“Recently, applications of MALDI-TOFMS have been extended to include the direct analysis of biological tissues and single cell organisms with the aim of characterizing endogenous peptide and protein constituents [11–18].”
BackgroundHarvey, D. J. (1993) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290070712 · Cited by 264 · cited 1×
“While there have been reports of quantitative MALDI-TOFMS applications, there are many problems inherent to the MALDI ionization process that have restricted its widespread use [19–39].”
BackgroundSingle-cell MALDI: a new tool for direct peptide profiling
Li, L., Garden, R. W., & Sweedler, J. V. (2000) · Trends in Biotechnology · doi:10.1016/s0167-7799(00)01427-x · Cited by 252 · cited 1×
“Recently, applications of MALDI-TOFMS have been extended to include the direct analysis of biological tissues and single cell organisms with the aim of characterizing endogenous peptide and protein constituents [11–18].”
BackgroundStoeckli, M., Farmer, T. B., & Caprioli, R. M. (1999) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(98)00126-3 · Cited by 201 · cited 1×
“Recently, applications of MALDI-TOFMS have been extended to include the direct analysis of biological tissues and single cell organisms with the aim of characterizing endogenous peptide and protein constituents [11–18].”
BackgroundNelson, R. W., McLean, M. A., & Hutchens, T. W. (1994) · Analytical Chemistry · doi:10.1021/ac00081a008 · Cited by 130 · cited 2×
“Most of the studies to date have focused on the quantification of low mass analytes, in particular, alkaloids or active ingredients in agricultural or food products [40–45], whereas other studies have demonstrated the potential of MALDI-TOFMS for the quantification of biologically relevant analytes such as neuropeptid…”
BackgroundDuncan, M. W., Matanovic, G., & Poljak, A. (1993) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290071207 · Cited by 126 · cited 3×
“Most of the studies to date have focused on the quantification of low mass analytes, in particular, alkaloids or active ingredients in agricultural or food products [40–45], whereas other studies have demonstrated the potential of MALDI-TOFMS for the quantification of biologically relevant analytes such as neuropeptid…”
BackgroundSelf-citation
Cited by
Wang, W., Zhou, H., Lin, H., Roy, S., Shaler, T. A., Hill, L. R., Norton, S., Kumar, P., Anderle, M., & Becker, C. H. (2003) · Analytical Chemistry · doi:10.1021/ac026468x · Cited by 653
de Souza, G. A., de Godoy, L. M., & Mann, M. (2006) · Genome Biology · doi:10.1186/gb-2006-7-8-r72 · Cited by 411
Applications of MALDI Mass Spectrometry in Clinical Chemistry
Duncan, M. W., Nedelkov, D., Walsh, R., & Hattan, S. J. (2016) · Clinical Chemistry · doi:10.1373/clinchem.2015.239491 · Cited by 96
Self-citation
Metadata
- Authors
- Bucknall, M., Fung, K. Y. C., & Duncan, M. W.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-09-01
- Volume
- 13
- Issue
- 9
- Pages
- 1015-1027
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2009364448
- Cited by
- 173
- References
- 24
- FWCI
- 6.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Practical quantitative biomedical applications of MALDI-TOF mass spectrometry. https://app.cochat.ai/papers/10.1016/s1044-0305(02)00426-9
- The paper
- Bucknall, M., Fung, K. Y. C., & Duncan, M. W. (2002). Practical quantitative biomedical applications of MALDI-TOF mass spectrometry. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/s1044-0305(02)00426-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.