A universal algorithm for fast and automated charge state deconvolution of electrospray mass-to-charge ratio spectra
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
This article describes a new algorithm for charge state determination and deconvolution of electrospray ionization (ESI) mass-to-charge ratio spectra. The algorithm (ZSCORE) is based on a charge scoring scheme that incorporates all above-threshold members of a family of charge states or isotopic components, and deconvolves both low- and high-resolution mass-to-charge ratio spectra, with or without a peak list (stick plot). A scoring weight factor, log (I/I0), in which I is the signal magnitude at a calculated mass-to-charge ratio, and I0 is the signal threshold near that mass-to-charge ratio, was used in most cases. For high-resolution mass-to-charge ratio spectra in which all isotopic peaks are resolved, the algorithm can deconvolve overlapped isotopic multiplets of the same or different charge state. Compared to other deconvolution techniques, the algorithm is robust, rapid, and fully automated (i.e., no user input during the deconvolution process). It eliminates artifact peaks without introducing peak distortions. Its performance is demonstrated for experimental ESI Fourier transform ion cyclotron resonance mass-to-charge ratio spectra (both low and high resolution). Charge state deconvolution to yield a "zero-charge" mass spectrum should prove particularly useful for interpreting spectra of complex mixtures, identifying contaminants, noncovalent adducts, fragments (N-terminal, C-terminal, internal), and chemical modifications of electrosprayed biomacromolecules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
From ions in solution to ions in the gas phase - the mechanism of electrospray mass spectrometry
Kebarle, P., & Tang, L. (1993) · Analytical Chemistry · doi:10.1021/ac00070a001 · Cited by 781
Covey, T. R., Bonner, R. F., Shushan, B. I., Henion, J., & Boyd, R. K. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290021111 · Cited by 593
Interpreting mass spectra of multiply charged ions
Mann, M., Meng, C. K., & Fenn, J. B. (1989) · Analytical Chemistry · doi:10.1021/ac00190a023 · Cited by 588
Smith, R. D., Loo, J. A., Loo, R. R. O., Busman, M., & Udseth, H. R. (1991) · Mass Spectrometry Reviews · doi:10.1002/mas.1280100504 · Cited by 569
Disentangling electrospray spectra with maximum entropy
Ferrige, A. G., Seddon, M. J., Green, B. N., Jarvis, S. A., Skilling, J., & Staunton, J. (1992) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290061115 · Cited by 261
Senko, M. W., Canterbury, J. D., Guan, S., & Marshall, A. G. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(199611)10:14<1839::aid-rcm718>3.0.co;2-v · Cited by 259
Self-citationElectrospray: Its potential and limitations as an ionization method for biomolecules
Mann, M. (1990) · Organic Mass Spectrometry · doi:10.1002/oms.1210251104 · Cited by 225
Electrospray Ionization Fourier Transform Ion Cyclotron Resonance at 9.4 T
Senko, M. W., Hendrickson, C. L., Paša-Tolić, L., Marto, J. A., White, F. M., Guan, S., & Marshall, A. G. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(199611)10:14<1824::aid-rcm695>3.0.co;2-e · Cited by 212
Self-citationHigh-resolution tandem FT mass spectrometry above 10 kDa
McLafferty, F. W. (1994) · Accounts of Chemical Research · doi:10.1021/ar00047a009 · Cited by 194
Maximum entropy deconvolution in electrospray mass spectrometry
Ferrige, A. G., Seddon, M. J., Jarvis, S., Skilling, J., & Aplin, R. (1991) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290050810 · Cited by 154
Automated assignment of charge states from resolved isotopic peaks for multiply charged ions
Senko, M. W., Beu, S. C., & McLafferty, F. W. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)00091-d · Cited by 119
Henry, K. D., & McLafferty, F. W. (1990) · Organic Mass Spectrometry · doi:10.1002/oms.1210250912 · Cited by 115
Electrospray ionization mass spectrometry: Deconvolution by an Entropy-Based algorithm
Reinhold, B. B., & Reinhold, V. N. (1992) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(92)87004-i · Cited by 113
Wu, Q., Orden, S. L. V., Cheng, X., Bakhtiar, R., & Smith, R. D. (1995) · Analytical Chemistry · doi:10.1021/ac00110a027 · Cited by 87
Three‐dimensional deconvolution of multiply charged spectra
Labowsky, M. J., Whitehouse, C., & Fenn, J. B. (1993) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290070117 · Cited by 50
Method for Estimating Molecular Mass from Electrospray Spectra
Hagen, J. J., & Monnig, C. A. (1994) · Analytical Chemistry · doi:10.1021/ac00083a017 · Cited by 46
Cited by
Marty, M. T., Baldwin, A. J., Marklund, E. G., Hochberg, G. K. A., Benesch, J. L. P., & Robinson, C. V. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00140 · Cited by 1,000
Automated reduction and interpretation of
Horn, D. M., Zubarev, R. A., & McLafferty, F. W. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00157-9 · Cited by 507
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Kurppa, K. J., Liu, Y., To, C., Zhang, T., Fan, M., Vajdi, A., Knelson, E. H., Xie, Y., Lim, K., Cejas, P., et al. (2020) · Cancer Cell · doi:10.1016/j.ccell.2019.12.006 · Cited by 475
Proteomics by FTICR mass spectrometry: Top down and bottom up
Bogdanov, B., & Smith, R. D. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20015 · Cited by 447
Metadata
- Authors
- Zhang, Z., & Marshall, A. G.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-03-01
- Volume
- 9
- Issue
- 3
- Pages
- 225-233
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2073682446
- Cited by
- 509
- References
- 17
- FWCI
- 3.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.