Sampling, noise-reduction and amplitude estimation issues in surface electromyography
The DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Numerical recipes in C: the art of scientific computing
(1993) · Choice Reviews Online · doi:10.5860/choice.30-5638 · Cited by 17,933
Random Data-Analysis and Measurement Procedures
Bendat, J. S., Piersol, A. G., & Saunders, H. (1989) · Journal of Vibration and Acoustics · doi:10.1115/1.3269865 · Cited by 6,375
Adaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939 · cited 4×
“Widrow et al. [73] decribed an adaptive interference cancellation method in which a reference input, which provides a signal correlated with the corrupting or interference signal, is adaptively filtered and subtracted from the corrupted signal, giving an estimate of the true signal.”
MethodInfluentialRandom data: Analysis and measurement procedures
Braun, S. (1987) · Mechanical Systems and Signal Processing · doi:10.1016/0888-3270(87)90088-4 · Cited by 2,359
Medical Instrumentation-Application and Design
Webster, J. G. (1978) · Journal of Clinical Engineering · doi:10.1097/00004669-197807000-00017 · Cited by 1,847
Muscles Alive—their functions revealed by electromyography
(1963) · Postgraduate Medical Journal · doi:10.1136/pgmj.39.449.162-b · Cited by 1,772
The relation between the surface electromyogram and muscular force.
Milner‐Brown, H. S., & Stein, R. B. (1975) · The Journal of Physiology · doi:10.1113/jphysiol.1975.sp010904 · Cited by 644
Kaplan, E. (1962) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-196244060-00031 · Cited by 589
Principles of Applied Biomedical Instrumentation.
(1975) · Annals of Internal Medicine · doi:10.7326/0003-4819-83-6-924_2 · Cited by 561
Relation of human electromyogram to muscular tension
Inman, V. T., Ralston, H. J., De C.M. Saunders, J. B., Bertram Feinstein, M. B., & Wright, E. W. (1952) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(52)90008-4 · Cited by 431
Bonato, P., D'Alessio, T., & Knaflitz, M. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.661154 · Cited by 375
Hogan, N., & Mann, R. W. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326652 · Cited by 241
Development of the Utah Artificial Arm
Jacobson, S. C., Knutti, D. F., Johnson, R. T., & Sears, H. H. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.325033 · Cited by 237
Minimizing Electrode Motion Artifact by Skin Abrasion
Tam, H., & Webster, J. G. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326117 · Cited by 220
High-pass filtering to remove electrocardiographic interference from torso EMG recordings
Redfern, M., Hughes, R., & Chaffin, D. (1993) · Clinical Biomechanics · doi:10.1016/s0268-0033(05)80009-9 · Cited by 209
Geometrical factors in surface EMG of the vastus medialis and lateralis muscles
Rainoldi, A., Nazzaro, M., Merletti, R., Farina, D., Caruso, I., & Gaudenti, S. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00024-9 · Cited by 192
Self-citationTrends in Ergonomics/Human Factors II
Mital, A., & Ergonomics, M.-C. (1985) · Medical Entomology and Zoology · Cited by 184
Ferdjallah, M., & Barr, R. E. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.293240 · Cited by 182
Reducing Motion Artifacts and Interference in Biopotential Recording
Webster, J. G. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325244 · Cited by 181
Probability density of the surface electromyogram and its relation to amplitude detectors
Clancy, E. A., & Hogan, N. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.764949 · Cited by 181
Self-citationReduction of Interference Due to Common Mode Voltage in Biopotential Amplifiers
Winter, B. B., & Webster, J. G. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325167 · Cited by 166
Physiology and Interpretation of the Electromyogram
Kamen, G., & Caldwell, G. E. (1996) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199609000-00002 · Cited by 160
Signal processing for the multistate myoelectric channel
Parker, P. A., Stuller, J. A., & Scott, R. N. (1977) · Proceedings of the IEEE · doi:10.1109/proc.1977.10545 · Cited by 147
Bilodeau, M., Cincera, M., Arsenault, B. A., & Gravel, D. (1997) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(96)00024-7 · Cited by 132
Reducing skin potential motion artefact by skin abrasion
Burbank, D. P., & Webster, J. G. (1978) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442929 · Cited by 130
Hogan, N., & Mann, R. W. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326653 · Cited by 126 · cited 9×
“Using four such electrodes, Hogan and Mann [37] [38] achieved an SNR performance improvement of approximately 91% compared to the single site rectify and low-pass filter estimator of Inman et al. [41].”
BackgroundMethodInfluentialMethods to reduce the variability of EMG power spectrum estimates
Baratta, R. V., Solomonow, M., Zhou, B.-H., & Zhu, M. (1998) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(97)00031-x · Cited by 124
An Optimality Criterion for Processing Electromyographic (EMG) Signals Relating to Human Locomotion
HERSHLER, C., & Milner, M. (1978) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1978.326338 · Cited by 116
Clancy, E. A., & Hogan, N. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.634654 · Cited by 106
Self-citationAdaptive whitening of the electromyogram to improve amplitude estimation
Clancy, E., & Farry, K. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.844217 · Cited by 99
Self-citationSingle site electromyograph amplitude estimation
Clancy, E. A., & Hogan, N. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284927 · Cited by 91
Self-citationMultiple site electromyograph amplitude estimation
Clancy, E. A., & Hogan, N. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.341833 · Cited by 88
Self-citationYanik, E. G. (1994) · SIAM Review · doi:10.1137/1036047 · Cited by 84
The Control of Upper‐Extremity Prostheses and Orthoses
MAXWELL, C. M. (1975) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.1975.tb95195.x · Cited by 77
Noise characteristics of stainless-steel surface electrodes
Godin, D. T., Parker, P. A., & Scott, R. N. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446089 · Cited by 69
Signal Versus Noise Characteristics of Filtered EMG Used as a Control Source
Kreifeldt, J. G. (1971) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1971.4502784 · Cited by 69
Clinical application of an active electrode using an operational amplifier
Nishimura, S., Tomita, Y., & Horiuchi, T. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.161342 · Cited by 69
Influence of smoothing window length on electromyogram amplitude estimates
St-Amant, Y., Rancourt, D., & Clancy, E. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.678614 · Cited by 64
Self-citationAdaptive filtering of the electromyographic signal for prosthetic control and force estimation
Park, E., & Meek, S. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.464381 · Cited by 63
Electromyogram amplitude estimation with adaptive smoothing window length
Clancy, E. A. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.764948 · Cited by 62
Self-citationSignal Processing for Proportional Myoelectric Control
Evans, H. B., Pan, Z., Parker, P. A., & Scott, R. N. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325330 · Cited by 42
Optimizing the acquisition and processing of surface electromyographic signals
Harba, M. I. A., & Lynn, P. A. (1981) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(81)90002-9 · Cited by 41
Pasteless electrode for clinical use
Luca, C. J. D., Lefever, R. S., & Stulen, F. B. (1979) · Medical & Biological Engineering & Computing · doi:10.1007/bf02443828 · Cited by 41
The Control of upper-extremity prostheses and orthoses
Herberts, P. (1974) · Thomas eBooks · Cited by 32
Comparison of signal-to-noise ratio of myoelectric filters for prosthesis control
Meek, S. G., & Feterston, S. J. (1992) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.1992.10.0009 · Cited by 32
Triolo, R. J., Nash, D. H., & Moskowitz, G. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.4591 · Cited by 30
Adaptive Removal of Motion Artifact
Hamilton, P. S., & Curley, M. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1997.754531 · Cited by 30
Analysis of a Digital EMG Signal Processor in Dynamic Conditions
D’Alessio, T. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325635 · Cited by 29
Some Aspects of Nonstationary Myoelectric Signal Processing
Xiong, F., & Shwedyk, E. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326041 · Cited by 29
A practical electrode-array myoprocessor for surface electromyography
Thusneyapan, S., & Zahalak, G. I. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.16479 · Cited by 23
Some Theoretic Results on a Digital EMG Signal Processor
Filligoi, G. C., & Mandarini, P. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325343 · Cited by 23
Zhang, Y., Parker, P. A., & Scott, R. N. (1990) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442671 · Cited by 18
Aronson, S., & Geddes, L. A. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325650 · Cited by 16
An optimal real-time digital processor for the electric activity of muscle.
Murray, W. R., & Rolph, W. D. (1985) · PubMed · Cited by 7
EMG Amplitude Estimation From Temporally Whitened, Spatially Uncorrelated Multiple Channel EMG
Clancy, E. A., & Hogan, N. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1990.691160 · Cited by 4
Self-citation
Cited by
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Committee report: Guidelines for human startle eyeblink electromyographic studies
Blumenthal, T. D., Cuthbert, B. N., Filion, D. L., Hackley, S., Lipp, O. V., & Van Boxtel, A. (2005) · Psychophysiology · doi:10.1111/j.1469-8986.2005.00271.x · Cited by 1,169
Surface Electromyography Signal Processing and Classification Techniques
Chowdhury, R., Reaz, M., Ali, M., Bakar, A., Chellappan, K., & Chang, T. (2013) · Sensors · doi:10.3390/s130912431 · Cited by 1,000
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Surface EMG based muscle fatigue evaluation in biomechanics
Cifrek, M., Medved, V., Tonković, S., & Ostojić, S. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2009.01.010 · Cited by 954
Metadata
- Authors
- Clancy, E. A., Morin, E. L., & Merletti, R.
- Venue
- Journal of Electromyography and Kinesiology
- Publisher
- Elsevier BV
- Published
- 2002-02
- Volume
- 12
- Issue
- 1
- Pages
- 1-16
- ISSN
- 1050-6411 (ISSN-L)
- OpenAlex
- W2170613067
- Cited by
- 634
- References
- 55
- FWCI
- 10.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.