A real-time gyroscopic system for three-dimensional measurement of lumbar spine motion
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This paper describes a new method of measuring the three-dimensional movements of the lumbar spine in real time. The measurement system consisted of solid-state gyroscopes which were attached to the trunk. They measured the angular rates of rotations in three dimensions, which were then integrated to obtain the orientation. The sensors contained gravitometers and magnetometers which provided additional information for eliminating any drift of the gyroscopes. The reliability of the data provided by the gyroscopic system was examined in a group of 19 young healthy subjects. The similarity of the movement-time curves obtained in three repeated measurements was assessed by the coefficient of multiple correlation. The coefficients were found to be high, ranging from 0.972 to 0.991. The reliability of the data was slightly lower for measuring axial rotation. The device did not only quantify the kinematic patterns in the primary plane of movements, but also the accompanying movements in the other planes. Flexion and extension was found to be mainly confined to the sagittal plane, whereas lateral bending and axial rotation always accompanied each other. It was concluded that the inertial tracking device would be a useful tool for clinical measurement as well as biomechanical investigations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216
A practical gait analysis system using gyroscopes
Tong, K., & Granat, M. H. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00030-2 · Cited by 460 · cited 2×
“The use of gyroscopes was primarily used for the measurement of human movements in one plane [17– 19,22].”
MethodDetecting absolute human knee angle and angular velocity using accelerometers and rate gyroscopes
Williamson, R., & Andrews, B. J. (2001) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345283 · Cited by 185
Cited by
The use of inertial sensors system for human motion analysis
Cuesta-Vargas, A. I., Galán-Mercant, A., & Williams, J. M. (2010) · Physical Therapy Reviews · doi:10.1179/1743288x11y.0000000006 · Cited by 369
Clinical Applications of Sensors for Human Posture and Movement Analysis: A Review
Wong, W. Y., Wong, M. S., & Lo, K. H. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640600983949 · Cited by 193
“Lee et al. (2003) described a method of using an inertial tracking device to measure three-dimensional movement patterns of the lumbar spine in real time, which consisted of gyroscopes, and also with gravitometers and magnetometers.”
BackgroundMethodEvaluation of a hybrid system for three-dimensional measurement of trunk posture in motion
Plamondon, A., Delisle, A., Larue, C., Brouillette, D., McFadden, D., Desjardins, P., & Larivière, C. (2007) · Applied Ergonomics · doi:10.1016/j.apergo.2006.12.006 · Cited by 102
Schall, M. C., Fethke, N. B., Chen, H., Oyama, S., & Douphrate, D. I. (2016) · Ergonomics · doi:10.1080/00140139.2015.1079335 · Cited by 96
Metadata
- Authors
- Lee, R. Y. W., Laprade, J., & Fung, E. H. K.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2003-08-12
- Volume
- 25
- Issue
- 10
- Pages
- 817-824
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2015777801
- Cited by
- 99
- References
- 3
- FWCI
- 5.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A real-time gyroscopic system for three-dimensional measurement of lumbar spine motion. https://app.cochat.ai/papers/10.1016/s1350-4533(03)00115-2
- The paper
- Lee, R. Y. W., Laprade, J., & Fung, E. H. K. (2003). A real-time gyroscopic system for three-dimensional measurement of lumbar spine motion. Medical Engineering & Physics. https://doi.org/10.1016/s1350-4533(03)00115-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.