Airborne infectious disease and the suppression of pulmonary bioaerosols
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Airborne pathogens generated from the lungs of an infected individual have three potential outcomes: pathogen aspiration, large droplets expelled, pathogen-infected droplet nuclei.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
AIRBORNE SPREAD OF MEASLES IN A SUBURBAN ELEMENTARY SCHOOL
RILEY, E. C., MURPHY, G., & RILEY, R. L. (1978) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a112560 · Cited by 932 · cited 1×
“Clear examples of the potential threat of airborne transmission include the dramatic spread of measles in the pre-vaccination era and the high death rate caused by airborne anthrax [1, 2] .”
The size and the duration of air-carriage of respiratory droplets and droplet-nuclei
Duguid, J. P. (1946) · Epidemiology and Infection · doi:10.1017/s0022172400019288 · Cited by 850
Transmission of the Severe Acute Respiratory Syndrome on Aircraft
Olsen, S. J., Chang, H.-L., Cheung, T. Y.-Y., Tang, A. F.-Y., Fisk, T. L., Ooi, S. P.-L., Kuo, H.-W., Jiang, D. D.-S., Chen, K.-T., Lando, J., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa031349 · Cited by 719
The size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690 · cited 2×
“More-recent experiments have utilized optical particle counting (OPC) to determine the size and concentration of droplets exhaled from all parts of the respiratory tract [17, 27, 28] .”
Marine aerosol, sea-salt, and the marine sulphur cycle: a short review
O'Dowd, C. D., Smith, M. H., Consterdine, I. E., & Lowe, J. A. (1997) · Atmospheric Environment · doi:10.1016/s1352-2310(96)00106-9 · Cited by 649 · cited 1×
“This momentum transfer results in wave-like disturbances that can lead to droplet creation -similar to aerosol formation from the surface of a wind-stirred sea [19] .”
(1994) · PsycEXTRA Dataset · doi:10.1037/e546872006-001 · Cited by 490
Intercomparison of experimental regional aerosol deposition data
STAHLHOFEN, W., RUDOLF, G., & JAMES, A. C. (1989) · Journal of Aerosol Medicine · doi:10.1089/jam.1989.2.285 · Cited by 423 · cited 1×
“Expired bioaerosols can also travel great distances and remain airborne for an extended period of time, particularly when droplet diameters are too large for diffusive deposition (>200 nm) or too small for gravitational deposition (<2 µm) [15, 16] .”
Dilution of Respiratory Solutes in Exhaled Condensates
EFFROS, R. M., HOAGLAND, K. W., BOSBOUS, M., CASTILLO, D., FOSS, B., DUNNING, M., GARE, M., LIN, W., & SUN, F. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.165.5.2101018 · Cited by 386 · cited 1×
“The passage of inhaled and exhaled air over the lung lining fluid entrains pathogens, resident in the lungs, in the form of droplets of airway lining fluid (ALF) that contain lung mucus and surfactant material [11] [12] [13] [14] .”
Inhaling to mitigate exhaled bioaerosols
Edwards, D. A., Man, J. C., Brand, P., Katstra, J. P., Sommerer, K., Stone, H. A., Nardell, E., & Scheuch, G. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0408159101 · Cited by 362 · cited 8×
“Two recent studies [17, 18] have shown that deposition of isotonic saline in humans and animals can significantly diminish the number of expired bioaerosol particles for several hours after deposition.”
InfluentialSelf-citationCough-generated Aerosols of Mycobacterium tuberculosis: A New Method to Study Infectiousness
Fennelly, K. P., Martyny, J. W., Fulton, K. E., Orme, I. M., Cave, D. M., & Heifets, L. B. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200308-1101oc · Cited by 327 · cited 1×
“[29] , they recently found that TB patients generated TB-laden bioaerosols <5 µm in diameter during coughing (with considerable patient-to-patient variability).”
BackgroundDroplet expulsion from the respiratory tract.
(1967) · PubMed · doi:10.1164/arrd.1967.95.3.435 · Cited by 240 · cited 2×
“Although Loudon and Roberts [26] found that coughing produced a droplet concentration that was an order of magnitude smaller than that reported by Duguid, they found a similar average droplet size (12 µm).”
A Simple Method for Estimating Respiratory Solute Dilution in Exhaled Breath Condensates
Effros, R. M., Biller, J., Foss, B., Hoagland, K., Dunning, M. B., Castillo, D., Bosbous, M., Sun, F., & Shaker, R. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200307-920oc · Cited by 221 · cited 1×
“The passage of inhaled and exhaled air over the lung lining fluid entrains pathogens, resident in the lungs, in the form of droplets of airway lining fluid (ALF) that contain lung mucus and surfactant material [11] [12] [13] [14] .”
Clearing the Air: The Theory and Application of Ultraviolet Air Disinfection
Riley, R. L., & Nardell, E. A. (1989) · American Review of Respiratory Disease · doi:10.1164/ajrccm/139.5.1286 · Cited by 204
Li, Y., Duan, S., Yu, I. T. S., & Wong, T. W. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00318.x · Cited by 194
Calculated deposition of inhaled particles in the airway generations of normal subjects
Gerrity, T. R., Lee, P. S., Hass, F. J., Marinelli, A., Werner, P., & Lourenco, R. V. (1979) · Journal of Applied Physiology · doi:10.1152/jappl.1979.47.4.867 · Cited by 180 · cited 1×
“Expired bioaerosols can also travel great distances and remain airborne for an extended period of time, particularly when droplet diameters are too large for diffusive deposition (>200 nm) or too small for gravitational deposition (<2 µm) [15, 16] .”
Particle Concentration in Exhaled Breath
FAIRCHILD, C. I., & STAMPFER, J. F. (1987) · American Industrial Hygiene Association Journal · doi:10.1080/15298668791385868 · Cited by 175 · cited 1×
“More-recent experiments have utilized optical particle counting (OPC) to determine the size and concentration of droplets exhaled from all parts of the respiratory tract [17, 27, 28] .”
MethodXu, P., Peccia, J., Fabian, P., Martyny, J. W., Fennelly, K. P., Hernandez, M., & Miller, S. L. (2003) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00825-7 · Cited by 169 · cited 1×
“Effectiveness depends on the irradiation level and the irradiation duration, lamp placement and age, room configuration, airflow patterns, ventilation rate and relative humidity [36, 37] .”
Brickner, P. W., Vincent, R. L., First, M., Nardell, E., Murray, M., & Kaufman, W. (2003) · Public Health Reports · doi:10.1016/s0033-3549(04)50225-x · Cited by 161 · cited 1×
“Despite their potential efficiency, filters require www.drugdiscoverytoday.com more-powerful fans for adequate ventilation (because they create resistance to air flow), must be changed periodically and require routine maintenance [34] .”
Physical Dynamics of the Cough Mechanism
Ross, B. B., Gramiak, R., & Rahn, H. (1955) · Journal of Applied Physiology · doi:10.1152/jappl.1955.8.3.264 · Cited by 160 · cited 1×
“During a forceful cough airspeeds as high as 200 m/s can be attained [21] .”
Respiratory protection against bioaerosols: Literature review and research needs
Rengasamy, A., Zhuang, Z., & BerryAnn, R. (2004) · American Journal of Infection Control · doi:10.1016/j.ajic.2004.04.199 · Cited by 138 · cited 1×
“However, studies have shown that a 'fit test' is crucial before the performance of all face masks can be guaranteed and personal compliance is also an obvious limitation [38, 39] .”
THE ENVIRONMENTAL CONTROL OF EPIDEMIC CONTAGION
WELLS, W. F., WELLS, M. W., & WILDER, T. S. (1942) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a118789 · Cited by 121 · cited 1×
“Air disinfection has proved effective in high-risk areas, for example, reducing the spread of measles in day schools [33] .”
BackgroundTemporal-Spatial Analysis of Severe Acute Respiratory Syndrome among Hospital Inpatients
Yu, I. T. S., Wong, T. W., Chiu, Y. L., Lee, N., & Li, Y. (2005) · Clinical Infectious Diseases · doi:10.1086/428735 · Cited by 117
Jones, A. M., Govan, J. R. W., Doherty, C. J., Dodd, M. E., Isalska, B. J., Stanbridge, T. N., & Webb, A. K. (2003) · Thorax · doi:10.1136/thorax.58.6.525 · Cited by 114 · cited 1×
“Pseudomonas aeruginosa is of particular concern in cystic fibrosis wards and its dissemination by the airborne route has been clearly demonstrated [10] .”
BackgroundThe numbers and the sites of origin of the droplets expelled during expiratory activities.
Jp, D. (1945) · PubMed Central · Cited by 106
Evanoff, B., Kim, L. E., Mutha, S., Jeffe, D. B., Haase, C., Andereck, D., & Fraser, V. J. (1999) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(99)70389-6 · Cited by 90 · cited 1×
“However, studies have shown that a 'fit test' is crucial before the performance of all face masks can be guaranteed and personal compliance is also an obvious limitation [38, 39] .”
Edwards, D. A., Brenner, H., & Wasan, D. T. (1991) · Elsevier eBooks · doi:10.1016/b978-0-7506-9185-7.50018-0 · Cited by 88
Self-citationEvaluation and Determinants of Airborne Bacterial Concentrations in School Classrooms
Bartlett, K. H., Kennedy, S., Brauer, M. D., van Netten, C., & Dill, B. (2004) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620490497744 · Cited by 86 · cited 1×
“With an adequate air exchange rate, ventilation can significantly decrease, although not completely eliminate, the number of pathogenic bioaerosols in the air [32] .”
Kim, T., Silva, J. L., & CHEN, T. C. (2002) · Journal of Food Protection · doi:10.4315/0362-028x-65.7.1142 · Cited by 82 · cited 1×
“UVGI systems provide either upper-room-air or ventilation-duct irradiation to inactivate pathogens and doses of UV irradiation vary significantly for different microorganisms [35] .”
Flow-induced instabilities of a mucus–serous bilayer
MORIARTY, J. A., & Grotberg, J. B. (1999) · Journal of Fluid Mechanics · doi:10.1017/s0022112099005704 · Cited by 62
ON THE MECHANICS OF DROPLET NUCLEI INFECTION
Wells, W. F. (1948) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a119176 · Cited by 43
Exposure to airborne Gram-negative bacteria, dust and endotoxin in paper factories.
Prazmo, Z., Dutkiewicz, J. K., Skórska, C., Sitkowska, J., & Cholewa, G. (2003) · PubMed · Cited by 40
Reservoirs of nosocomial pathogens in neonatal intensive care unit.
Chandrashekar, M., Rathish, K. C., & Nagesha, C. N. (1997) · PubMed · Cited by 36
Clarke, R. W., Katstra, J. P., Man, J. C., DeHaan, W. H., Edwards, D. A., & Griel, L. C. (2005) · American Journal of Infection Control · doi:10.1016/j.ajic.2005.04.101 · Cited by 9 · cited 6×
“Two recent studies [17, 18] have shown that deposition of isotonic saline in humans and animals can significantly diminish the number of expired bioaerosol particles for several hours after deposition.”
InfluentialSelf-citation
Cited by
The role of particle size in aerosolised pathogen transmission: a review
Gralton, J., Tovey, E., McLaws, M.-L., & Rawlinson, W. D. (2011) · Journal of Infection · doi:10.1016/j.jinf.2010.11.010 · Cited by 665
Aerosol transmission of influenza A virus: a review of new studies
Tellier, R. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0302.focus · Cited by 589
Airborne spread of infectious agents in the indoor environment
Wei, J., & Li, Y. (2016) · American Journal of Infection Control · doi:10.1016/j.ajic.2016.06.003 · Cited by 519
Mittal, R., Ni, R., & Seo, J.-H. (2020) · Journal of Fluid Mechanics · doi:10.1017/jfm.2020.330 · Cited by 494
Characterizations of particle size distribution of the droplets exhaled by sneeze
Han, Z. Y., Weng, W. G., & Huang, Q. Y. (2013) · Journal of The Royal Society Interface · doi:10.1098/rsif.2013.0560 · Cited by 383
Metadata
- Authors
- Fiegel, J., Clarke, R., & Edwards, D. A.
- Venue
- Drug Discovery Today
- Publisher
- Elsevier BV
- Published
- 2006-01
- Volume
- 11
- Issue
- 1-2
- Pages
- 51-57
- ISSN
- 1359-6446 (ISSN-L)
- OpenAlex
- W2070405622
- Cited by
- 184
- References
- 34
- FWCI
- 4.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.