Three-dimensional multi-scale line filter for segmentation and visualization of curvilinear structures in medical images
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Laplacian pyramid as a compact image code
Burt, P., & Adelson, E. (1983) · IEEE Transactions on Communications · doi:10.1109/tcom.1983.1095851 · Cited by 6,077 · cited 1×
“The sizes of the trimmed and intensity-converted images were reduced to half using the Laplacian pyramid (Burt and Adelson, 1983) to reduce a computational amount to a practical level.”
MethodDisplay of surfaces from volume data
Levoy, M. (1988) · IEEE Computer Graphics and Applications · doi:10.1109/38.511 · Cited by 2,446
The Visualization Toolkit: An Object-Oriented Approach to 3-D Graphics
Schroeder, W. J., & Lorenson, B. (1997) · Cited by 1,882
Edge Detection and Ridge Detection with Automatic Scale Selection
Lindeberg, T. (1998) · International Journal of Computer Vision · doi:10.1023/a:1008097225773 · Cited by 1,024
Fast volume rendering using a shear-warp factorization of the viewing transformation
Lacroute, P., & Levoy, M. (1994) · Proceedings of the 21st annual conference on Computer graphics and interactive techniques - SIGGRAPH '94 · doi:10.1145/192161.192283 · Cited by 1,013
Edge and Curve Detection for Visual Scene Analysis
Rosenfeld, A., & Thurston, M. (1971) · IEEE Transactions on Computers · doi:10.1109/t-c.1971.223290 · Cited by 781
Dynamic gadolinium‐enhanced three‐dimensional abdominal MR arteriography
Prince, M. R., Yucel, E. K., Kaufman, J. A., Harrison, D. C., & Geller, S. C. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030614 · Cited by 499
Three‐dimensional phase contrast angiography
Dumoulin, C. L., Souza, S. P., Walker, M. F., & Wagle, W. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910090117 · Cited by 432
Sato, Y., Nakajima, S., Atsumi, H., Koller, T., Gerig, G., Yoshida, S., & Kikinis, R. (1997) · Lecture Notes in Computer Science · doi:10.1007/bfb0029240 · Cited by 396
Self-citationFischler, M. A., Tenenbaum, J. M., & Wolf, H. C. (1981) · Computer Graphics and Image Processing · doi:10.1016/0146-664x(81)90056-3 · Cited by 354
Edge detection and ridge detection with automatic scale selection
Lindeberg, T. (1996) · Proceedings CVPR IEEE Computer Society Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.1996.517113 · Cited by 345
Tissue classification based on 3D local intensity structures for volume rendering
Sato, Y., Westin, C., Bhalerao, A., Nakajima, S., Shiraga, N., Tamura, S., & Kikinis, R. (2000) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/2945.856997 · Cited by 338
Self-citationMultiscale detection of curvilinear structures in 2-D and 3-D image data
Koller, T. M., Gerig, G., Szekely, G., & Dettwiler, D. (2002) · Proceedings of IEEE International Conference on Computer Vision · doi:10.1109/iccv.1995.466846 · Cited by 314
Self-citationLorenz, C., Carlsen, I. C., Buzug, T. M., Fassnacht, C., & Weese, J. (1997) · Lecture Notes in Computer Science · doi:10.1007/bfb0029242 · Cited by 283
Haralick, R. M., Watson, L. T., & Laffey, T. J. (1983) · The International Journal of Robotics Research · doi:10.1177/027836498300200105 · Cited by 280
Du, Y. P., Parker, D. L., Davis, W. L., & Cao, G. (1994) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880040517 · Cited by 216
Radiographic Applications of Receiver Operating Characteristic (ROC) Curves
Goodenough, D. J., Rossmann, K., & Lusted, L. B. (1974) · Radiology · doi:10.1148/110.1.89 · Cited by 203
Multiresolution analysis of ridges and valleys in grey-scale images
Gauch, J. M., & Pizer, S. M. (1993) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.216734 · Cited by 141
A Tensor Framework for Multidimensional Signal Processing
Westin, C. (1994) · DiVA (Linkoping University) · Cited by 112
Sato, Y., Chen, J., Zoroofi, R. A., Harada, N., Tamura, S., & Shiga, T. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.563292 · Cited by 66
Self-citation
Cited by
Design and validation of a tool for neurite tracing and analysis in fluorescence microscopy images
Meijering, E., Jacob, M., Sarria, J. ‐. F., Steiner, P., Hirling, H., & Unser, M. (2004) · Cytometry Part A · doi:10.1002/cyto.a.20022 · Cited by 1,608
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“That is why a number of task-tailored detectors have been devised [280]–[283].”
BackgroundA Computational Tool for Quantitative Analysis of Vascular Networks
Zudaire, E., Gambardella, L., Kurcz, C., & Vermeren, S. (2011) · PLoS ONE · doi:10.1371/journal.pone.0027385 · Cited by 1,085
Longair, M. H., Baker, D. A., & Armstrong, J. D. (2011) · Bioinformatics · doi:10.1093/bioinformatics/btr390 · Cited by 970
Wang, G., McCain, M. L., Yang, L., He, A., Pasqualini, F. S., Agarwal, A., Yuan, H., Jiang, D., Zhang, D., Zangi, L., et al. (2014) · Nature Medicine · doi:10.1038/nm.3545 · Cited by 837
Metadata
- Authors
- Sato, Y., Nakajima, S., Shiraga, N., Atsumi, H., Yoshida, S., Koller, T., Gerig, G., & Kikinis, R.
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 1998-06
- Volume
- 2
- Issue
- 2
- Pages
- 143-168
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W2096320880
- Cited by
- 1,163
- References
- 20
- FWCI
- 16.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.