Location of innervation zones of sternocleidomastoid and scalene muscles – a basis for clinical and research electromyography applications
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of recommendations for SEMG sensors and sensor placement procedures
Hermens, H. J., Freriks, B., Disselhorst-Klug, C., & Rau, G. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00027-4 · Cited by 7,213 · cited 1×
“In reviewing 144 papers on sEMG, Hermens et al. (2000) identified 352 descriptions of electrode location – most being generic terms such as ‘muscle belly’, ‘motor point’ or ‘midpoint of the muscle’.”
BackgroundMyoelectric manifestations of fatigue in voluntary and electrically elicited contractions
Merletti, R., Knaflitz, M., & De Luca, C. J. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.69.5.1810 · Cited by 610
Self-citationSurface Electromyography for Noninvasive Characterization of Muscle
Merletti, R., Rainoldi, A., & Farina, D. (2001) · Exercise and Sport Sciences Reviews · doi:10.1097/00003677-200101000-00005 · Cited by 325
Self-citationEffects of electrode location on myoelectric conduction velocity and median frequency estimates
Roy, S. H., De Luca, C. J., & Schneider, J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.61.4.1510 · Cited by 260
Deep Cervical Flexor Muscle Dysfunction in Whiplash
Jull, G. A. (2000) · Journal of Musculoskeletal Pain · doi:10.1300/j094v08n01_12 · Cited by 252
Self-citationUse of surface electromyography to estimate neck muscle activity
Sommerich, C. M., Joines, S. M. B., Hermans, V., & Moon, S. D. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00033-x · Cited by 243
Barton, P. M., & Hayes, K. C. (1996) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(96)90008-8 · Cited by 204
Geometrical factors in surface EMG of the vastus medialis and lateralis muscles
Rainoldi, A., Nazzaro, M., Merletti, R., Farina, D., Caruso, I., & Gaudenti, S. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00024-9 · Cited by 192 · cited 1×
“Research has demonstrated that positioning sEMG electrodes over the IZ and movement of muscle underneath sEMG electrodes can substantially alter sEMG amplitude variables (Masuda et al., 1985; Roy et al., 1986; Mathiassen and Hägg, 1997; Rainoldi et al., 2000).”
BackgroundSelf-citationThe Position of Innervation Zones in the Biceps Brachii Investigated by Surface Electromyography
Masuda, T., Miyano, H., & Sadoyama, T. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325614 · Cited by 178
Non-invasive assessment of motor unit properties with linear electrode arrays.
Merletti, R., Farina, D., & Granata, A. (1999) · PubMed · Cited by 118
Self-citation
Cited by
Falla, D. L., Jull, G. A., & Hodges, P. W. (2004) · Spine · doi:10.1097/01.brs.0000141170.89317.0e · Cited by 617
Self-citationA method for positioning electrodes during surface EMG recordings in lower limb muscles
Rainoldi, A., Melchiorri, G., & Caruso, I. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.014 · Cited by 610
Self-citationFalla, D., Bilenkij, G., & Jull, G. (2004) · Spine · doi:10.1097/01.brs.0000128759.02487.bf · Cited by 499
Self-citationImpairment in the cervical flexors: a comparison of whiplash and insidious onset neck pain patients
Jull, G., Kristjansson, E., & Dall’Alba, P. (2004) · Manual Therapy · doi:10.1016/s1356-689x(03)00086-9 · Cited by 452
Self-citationDevelopment of motor system dysfunction following whiplash injury
Sterling, M., Jull, G., Vicenzino, B., Kenardy, J., & Darnell, R. (2003) · Pain · doi:10.1016/s0304-3959(02)00420-7 · Cited by 365
Self-citationJull, G. A., Falla, D., Vicenzino, B., & Hodges, P. W. (2009) · Manual Therapy · doi:10.1016/j.math.2009.05.004 · Cited by 361
Self-citationFalla, D., Jull, G., & Hodges, P. W. (2004) · Experimental Brain Research · doi:10.1007/s00221-003-1814-9 · Cited by 326
Self-citationUnravelling the complexity of muscle impairment in chronic neck pain
Falla, D. (2004) · Manual Therapy · doi:10.1016/j.math.2004.05.003 · Cited by 320
Self-citationClinical applications of high-density surface EMG: A systematic review
Drost, G., Stegeman, D. F., van Engelen, B. G. M., & Zwarts, M. J. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.09.005 · Cited by 311
Current state of digital signal processing in myoelectric interfaces and related applications
Hakonen, M., Piitulainen, H., & Visala, A. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.02.009 · Cited by 305
Multichannel surface EMG: Basic aspects and clinical utility
Zwarts, M. J., & Stegeman, D. F. (2003) · Muscle & Nerve · doi:10.1002/mus.10358 · Cited by 302
Jull, G., Amiri, M., Bullock-Saxton, J., Darnell, R., & Lander, C. (2007) · Cephalalgia · doi:10.1111/j.1468-2982.2007.01345.x · Cited by 256
Self-citationFalla, D., Jull, G., Dall'Alba, P., Rainoldi, A., & Merletti, R. (2003) · Physical Therapy · doi:10.1093/ptj/83.10.899 · Cited by 206
Self-citationSurface EMG: The issue of electrode location
Mesin, L., Merletti, R., & Rainoldi, A. (2009) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2008.07.006 · Cited by 200
“…of the surface EMG has been addressed in a number of methodological and clinical publications (Castroflorio et al., 2005; Cote and Mathieu, 2000; Falla et al., 2002; Fuglevand et al., 1992; Hogrel et al., 1998; Kiryu et al., 1996; Li and Sakamoto, 1996; Lynn et al., 1978; Mercer et al., 2006;…”
BackgroundSelf-citationNeck Movement and Muscle Activity Characteristics in Female Office Workers With Neck Pain
Johnston, V, Jull, G., Souvlis, T., & Jimmieson, N. L. (2008) · Spine · doi:10.1097/brs.0b013e3181657d0d · Cited by 195
Self-citationCharacterization of Acute Whiplash-Associated Disorders
Sterling, M., Jull, G., Vicenzino, B., & Kenardy, J. (2004) · Spine · doi:10.1097/01.brs.0000105535.12598.ae · Cited by 192
“Pairs of standard Ag-AgCl electrodes (Conmed, USA) were positioned along the lower one third of the muscle bellies of both sternocleidomastoid (SCM) muscles.(28) The EMG signals were passed through a 10-Hz high-pass filter and amplified to 20,000 U using an AMLAB data acquisition system (Associated Measurements Pty Lt…”
MethodSelf-citationFalla, D., Rainoldi, A., Merletti, R., & Jull, G. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00418-2 · Cited by 186
Self-citationA thin, flexible multielectrode grid for high-density surface EMG
Lapatki, B. G., van Dijk, J. P., Jonas, I. E., Zwarts, M. J., & Stegeman, D. F. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00521.2003 · Cited by 172
“Knowledge of the location of neuromuscular junctions and areas of high signal amplitude is indispensable in establishing guidelines for placement of conventional electrode configurations (9, 34).”
BackgroundFalla, D., Jull, G., Hodges, P., & Vicenzino, B. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.12.025 · Cited by 168
Self-citationPerformance of the Craniocervical Flexion Test in Subjects With and Without Chronic Neck Pain
Wing Chiu, T. T., Hung Law, E. Y., & Fai Chiu, T. H. (2005) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2005.35.9.567 · Cited by 163
Stepp, C. E. (2012) · Journal of Speech, Language, and Hearing Research · doi:10.1044/1092-4388(2011/11-0214 · Cited by 161
Chest wall volumes during inspiratory loaded breathing in COPD patients
Coutinho Myrrha, M. A., Vieira, D. S. R., Moraes, K. S., Lage, S. M., Parreira, V. F., & Britto, R. R. (2013) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2013.04.017 · Cited by 30
Wang, F., & Yiu, E. M. (2024) · Journal of Voice · doi:10.1016/j.jvoice.2021.10.006 · Cited by 13
Metadata
- Authors
- Falla, D., Dall'Alba, P., Rainoldi, A., Merletti, R., & Jull, G.
- Venue
- Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 2002-01
- Volume
- 113
- Issue
- 1
- Pages
- 57-63
- ISSN
- 1388-2457 (ISSN-L)
- OpenAlex
- W2042222781
- Cited by
- 277
- References
- 11
- FWCI
- 7.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.